EMD Value
₹35,000
Closing Date
27 Apr 2026, 5:05 pmClosed
Executive Engineer Jal Shakti Division Ghumarwin
Executive Engineer Jal Shakti Division Ghumarwin
Providing and Installation of Real Time Online Monitoring System for sewerage treatment plant 1 20 MLD Ghumarwin in Tehsil Ghumarwin Distt Bilaspur HP SH Providing and installation various fitting accessories
2026_HPIPH_134748_1
GMR-BLP02-737(713-50)Real
Open Tender
Civil Works
Item Rate
60 days
Ghumarwin
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
₹35,000
16 May 2026
20 Apr 2026
28 Apr 2026
20 Apr 2026
27 Apr 2026
20 Apr 2026
20 Apr 2026 - 27 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Providing and Fixing of Online Continuous Effluent Quality Monitoring System (OCEMS) for measuring BOD, COD, TSS, pH and DO at the outlet of STP with the following technical specifications:-
* Measuring Range of pH:- 2–12 at least considering the wastewater environment (sensor designed for wastewater application)
* Accuracy of pH: ±0.2 pH
* Calibration of pH:- Calibration with 4 and 7 buffer accuracy ( 2-point calibration) and Buffer should be technical buffer
* MOC of pH probe: Stainless Steel or better (Electrode Should have protection for the electrode)
* Measuring Range:-TSS, COD, BOD:- COD: 0–800 mg/l OD: 0–500mg/l TSS: 0–900 mg/l
* Measurement Principle:-Measurement of full-wave length spectra (UV-VIS Spectrometry) from 200–720 nm, as per CPCB Guidelines.Note:-UV-VIS spectrophotometer with singe beam or using a single beam or using a single wavelength (I.e 254 mm),dual wavelength, eight wavelength or few wavelength bands to estimate COD/BOD values will not be acceptable as per the CPCB Guidelines *Accuracy of TSS ,COD ,BOD : Accuracy in Standard Solutions +/- 5% of the measured value lab results
* Calibration TSS ,COD,BOD: Multipoint Calibration (24 points calibration as per latest CPCB SOP Version 1.0,page no.4)
* MOC of TSS,COD, BOD probe: The MOC of Sensor Probe must be of Titanium Material with window of Sapphire Glass to Sustain the sensor in highly corrosive wastewater Environment
* Measurement :Must be direct in-situ measurement in outlet of waste water treatment plant
* Inbuilt Cleaning:- The sebsor must be preferably with efficient integated ultrsonic facility or any other chemical free cleaning. all leads and lifts to the entire satisfaction of Engineer-in-Charge | 1 | Each | - | - |
| - | Providing and fixing of SMPS 24VDC @ 5A at the outlet of STP in all leads and lifts to the entire satisfaction of Engineer-in-Charge. | 1 | Each | - | - |
| - | Providing and fixing of Data logger 8×Analog Input, 1×RS485 of Make NEVCO in all leads and lifts to the entire satisfaction of Engineer-in-Charge. | 1 | Each | - | - |
| - | Data transmission of BOD, COD, TSS, pH, Temperature and Flow to PCB & SPCB for 1 year in all leads and lifts to the entire satisfaction of Engineer-in-Charge. | 1 | Each | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Form6.pdf
Tender Documents • 0.46 MB
BOQ_199419.xls
BOQ • 0.29 MB
Condi.pdf
Additional Documents • 0.33 MB
Form8.pdf
Tender Documents • 0.90 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .