| Sl No | Description | Qty | Unit | Anup Kumar Paul Choudhury L1 | MS AFTAB LASKAR L2 | M/S MANIK LAL GUPTA L4 | SHRI YOUNUS KHAN L3 |
|---|---|---|---|---|---|---|---|
| 1.00B/R WORKS | |||||||
| 2.00 | Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame) and disposing off | 15 | Each | 300 ₹4,500 | 320 ₹4,800 | 290 ₹4,350 Lowest | 320 ₹4,800 |
| 3.00 | Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4sqm each but with shutters (without taking off shutters from the frame) and disposing off | 10 | Each | 300 ₹3,000 | 320 ₹3,200 | 295 ₹2,950 Lowest | 300 ₹3,000 |
| 4.00 | Taking down wooden shutters of size not exceeding 1.0sqm and disposing off complete all as specified and directed | 2 | Each Leaf | 60 ₹120 Lowest | 66 ₹132 | 65 ₹130 | 60 ₹120 Lowest |
| 5.00 | Taking down wooden shutters of size exceeding 1.0sqm but not exceeding 2.0sqm and disposing off complete all as specified and directed | 5 | Each Leaf | 100 ₹500 Lowest | 100 ₹500 Lowest | 110 ₹550 | 100 ₹500 Lowest |
| 6.00 | Taking down wooden shutters of size not exceeding 1.0sqm and refixing in same opening after minor repairs, easing out, etc. complete all as specified and directed | 2 | Each Leaf | 150 ₹300 Lowest | 155 ₹310 | 160 ₹320 | 200 ₹400 |
| 7.00 | Taking down wooden shutters of size exceeding 1.0sqm but not exceeding 2.0sqm and refixing in same opening after minor repairs, easing out, etc. complete all as specified and directed | 2 | Each Leaf | 200 ₹400 Lowest | 200 ₹400 Lowest | 205 ₹410 | 200 ₹400 Lowest |
| 8.00 | Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed | 0.3 | Cum | 700 ₹210 Lowest | 720 ₹216 | 800 ₹240 | 700 ₹210 Lowest |
| 9.00 | Dismantling boarding any description fixed in any position with nails complete all as specified and directed. | 5 | Sqm | 40 ₹200 | 44 ₹220 | 39 ₹195 Lowest | 45 ₹225 |
| 10.00 | Dismantling of timber fillets rails, posts, rafters, purlins, etc. under 40sqcm in section, in any position in unframed works complete all as specified and as directed | 20 | Rm | 20 ₹400 Lowest | 20 ₹400 Lowest | 20 ₹400 Lowest | 20 ₹400 Lowest |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
17 Jul 2025, 6:00 pmClosed
GE
GE SILCHAR MASIMPUR
WELCOME MAINTENANCE PERIODICAL SERVICES AND COMPREHENSIVE MAINTENANCE B R AND E M OF CHANDPUR ENCLAVE DACCA COLONY AND SILCHAR OFFICERS QUARTERS AT MASIMPUR UNDER GE SILCHAR
2025_MES_715265_1
8968/E8
Open Tender
Civil Works
Item Rate
270 days
Masimpur
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE Silchar
₹89,000
Yes
25 Sept 2025
18 Jun 2025
19 Jul 2025
18 Jun 2025
17 Jul 2025
3 Jul 2025
22 Jun 2025 - 30 Jun 2025
Amount
B/R WORKS
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame) and disposing off
Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4sqm each but with shutters (without taking off shutters from the frame) and disposing off
Taking down wooden shutters of size not exceeding 1.0sqm and disposing off complete all as specified and directed
Taking down wooden shutters of size exceeding 1.0sqm but not exceeding 2.0sqm and disposing off complete all as specified and directed
Taking down wooden shutters of size not exceeding 1.0sqm and refixing in same opening after minor repairs, easing out, etc. complete all as specified and directed
Taking down wooden shutters of size exceeding 1.0sqm but not exceeding 2.0sqm and refixing in same opening after minor repairs, easing out, etc. complete all as specified and directed
Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed
Dismantling boarding any description fixed in any position with nails complete all as specified and directed.
Dismantling of timber fillets rails, posts, rafters, purlins, etc. under 40sqcm in section, in any position in unframed works complete all as specified and as directed
Dismantling of wall and ceiling boards (fibre,pulp, insulation, etc. or insulation boards/slabs/blankets, any thickness including cover fillets, frameworks, etc. and disposing off complete all as specified and as directed
Dismantling mild steel work or wraught iron of any description and in any position complete all as specified and as directed
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
Taking down cement or cement/lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed
Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
Taking up or down 20mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed
Dismantling rain water pipe and sewage line pipe of any type and any size including fitting complete all as specified and as directed
Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm in girth complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed
M&L for rendering 5mm thick plaster, in cement mortar (1:3) on fair faces of concrete surfaces of soffits of slabs, ceilings, etc. finished even and fair without using extra cement complete all as specified and as directed
M&L rendering 10mm thick, in cement mortar (1:3) mixed with integral water proofing compound @3% by weight of cement, finished even and fair without using extra cement on roof slabs complete all as specified and as directed
M&L for for 10mm thick rendering in cement mortar (1:6) on other than fair faces of brick wall masonry/concrete surfaces, surface finished even and smooth without using extra cement complete all as specified and as directed
M&L rendering 15mm thick, in cement mortar (1:4) on other than fair faces of brick wall masonry/concrete surfaces in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and fair without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein
Supply only integral water proofing compound all as specified
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed
M&L for plain cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregates) as in roof kerbs, levelling courses, etc. complete all as specified and as directed
M&L for 40mm thick plain cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregates) as in levelling courses over roof and similar works, finished fair and even complete all as specified and as directed
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed
M&L for PCC 1:3:6, type C-1, using 20mm graded aggregates as in surface channels, finished even & fair without using extra cement complete all as specified and as directed
M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed
M&L for 100mm thick PCC 1:3:6, type C-2, using 40mm graded aggregates as in bases for floors, etc. finished fair and even complete all as specified and as directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed Note: Inner girth shall only be measured
Add or deduct for each 25mm girth or part thereof over or under 30cm (for adjustment in girth in item No. 48 hreinabove)
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles, laid over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed
M&L for glazed ceramic tiles, coloured, of size 450x300x7mm thick of superior quality as in skirting, dado, etc. laid over 10mm thick backing coat in CM (1:4) (rate shall be included) pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
M&L for vitrified tiles, coloured, 10mm thick, joint free, edge cut, area of each tile exceeding 0.18sqm but not exceeding 0.36sqm, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed
M&L for vitrified tiles, coloured, 10mm thick, joint free, edge cut, area of each tile exceeding 0.18sqm but not exceeding 0.36sqm, of superior quality as in skirting, dado, etc. laid against and including 10mm thick screed bed in CM (1:4) (rate shall be included) pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
M&L in repairs for 18-20mm thick granite stone slab, of any type, table rubbed and polished, in steps, jambs, pillars, window cills, cooking platforms and the like in laid over and including 15mm thick screed in cement mortar (1:4) (rate shall be included) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab and taking off old damaged slab and disposing off complete all as specified and as directed
M&L for pre-polished chequered coloured paver tiles 25mm thick, area of each tile exceeding 0.06sqm but not exceeding 0.11sqm, in floors, set, jointed & pointed with neat white cement slurry mixed with pigment to match colour of tile, laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) (rate shall be included) complete all as specified and as directed
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain / printed coloured PVC sheet (as approved) reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width, stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed
S&F factory made wire gauzed PVC moulded door shutter 30mm thick (style) panel will be of wire gauzed in lieu of single side prelaminated sheet panel, wire gauze wrapped in an additional square 8mm MS solid tube and this tube shall be welded to MS tubes the the wire gauze stretched and tightened firmly consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain coloured PVC ‘C’ channel having a PVC sheet strip of 20mm wide, stuck inside with solvent cement for stiles and prelaminated coloured PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain coloured PVC sheetfitted in the MS frame welded/sealed to the stiles & at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed
S&F factory made 28 to 30mm thick single/double leaf solid PVC moulded door shutter with particle board core, stiles, with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2mm plain coloured termite proof, water proof and fire resisitant PVC sheet on back face, supplying & fixing in frame at site as per requirement complete all as specified and as directed
M&L 35mm thick factory made plain framed paneled door shutter (any number of panels) 2nd class HW rail and style with lock rail and panels of 12mm thick ISI marked veeneered particle board with commercial veeneering on both faces, with size of rail and style shall be as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and as directed
S&F 35mm thick 2nd class hard wood glazed and skeleton door shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, prepared to receive glass, gauge, etc. edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., and sizes of members of shutters as specified in section 8, clause 8.24(b) of SSR Part-I, supplied and fitted to chowkats complete all as specified and as directed
S&F 30mm thick 2nd class hard wood glazed and skeleton window / ventilator shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, prepared to receive glass, gauge, etc. edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., and sizes of members of shutters as specified in section 8, clause 8.24(b) of SSR Part-I, supplied and fitted to chowkats complete all as specified and as directed
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with 6/8mm thick lipping of polished teak wood allround complete all as specified and as directed
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed
S&F pressed steel frames of size 125x60mm, fabricated out of 1.25mm thick MS sheet of profile 125x60mm, for doors / windows, with one or more rebates including necessary fixing lugs, stainless steel hinges (100/50mm), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed
S&F pressed steel frames of size 105x60mm, fabricated out of 1.25mm thick MS sheet of profile 125x60mm, for doors / windows, with one or more rebates including necessary fixing lugs, stainless steel hinges (100/50mm), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed
M&L for 2nd class hard wood timber scantling wrought in section, timber framed & fixed complete all as specified and as directed
M&L for 2nd class hard wood timber scantlingclean swan in section, timber framed & fixed complete all as specified and as directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty, square not exceeding 0.5sqm in each pane complete all as specified and as directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty, including hacking out old broken glass (any thickness, size quality or description) from wooden frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads square not exceeding 0.5sqm in each pane complete all as specified and as directed
S&F 300mm aluminium anodised sliding door bolt, bright finish, with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed
S&F 150mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed
S&F 100mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed
S&F 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed
S&F 125mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed
S&F 100mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed
S&F 75mm MS butt hinges, medium weight, cold rolled complete all as specified and as directed
S&F 100mm MS butt hinges, medium weight, cold rolled complete all as specified and as directed
S&F double action floor spring hinges,MS with steel wire spring,stove enamelled, black, size 150mm, complete all as specified and as directed
S&F 150mm floor door stopper aluminium alloy body and tongue, anodized with hard drawn steel spring fixed on floor complete all as specified and as directed
S&F in repairs 25mm dia fancy type MS chromium plated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of brackets,knobs, holders with funnel at ends complete all as specified and as directed
M&L for 18/19mm thick block boards, grade 2 quality, interior grade, commercial type fixed with screws to timber frame work as in cupboard shelves, doors, etc. including taking off old unserviceable boards and disposing off complete all as specified and as directed
M&L for 2nd class hardwood fillets square, rectangular or tringular in section clean sawn screwed with nails exceeding 6sqcm and not exceeding 13sqcm in section complete all as specified and as directed
M&L for 2nd class hardwood fillets square, rectangular or tringular in section clean sawn screwed with nails exceeding 13sqcm and not exceeding 25sqcm in section complete all as specified and as directed
M&L for 2nd class hardwood fillets square, rectangular or tringular in section wrought screwed with nails exceeding 6sqcm and not exceeding 13sqcm in section complete all as specified and as directed
M&L for 2nd class hardwood fillets square, rectangular or tringular in section wrought screwed with nails exceeding 13sqcm and not exceeding 25sqcm in section complete all as specified and as directed
M&L for 2nd class hardwood plain fillets, square, rectangular and triangular in section, wrought, bull nosed, splayed, chamfered or rounded on one edge or face, sectional area exceeding 6sqcm but not exceeding 13sqcm complete all as specified and as directed
S&F 4mm thick asbestos cement plain building boards, fixed to timber framework with screws complete all as specified and as directed
S&F steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast including suitable locking arrangements complete all as specified and as directed
S&F steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including suitable locking arrangements complete all as specified and as directed
S&F steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete without glazing bars, dovetailed or welded, including suitable locking arrangements complete all as specified and as directed
M&L for suspended false ceiling using E-grid 2430, 180GSM (exposed ceiling suspension system) as per IS-14862, of grid size 600x600mm with main runner 38x24mm and wall angle 24x24mm using 4mm thick high pressure stean crude non-asbestos fiber cement plain board in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning vents, diffuser and ducts, sprinkler, smoke detectors, etc., main runners secured to structural soffits by hanger @1220mm maximum c/c and the last hanger at the end of each main runner placed at more than 450mm from the adjucent wall, flush fitting 1220mm cross tee interlocked between main runners @610mm c/c forming 600x600mm grid and painting with two coats of acrylic emulsion paint (of approved shade) over a coat of cement primer before installing it on the grid complete all as specified and as directed
M&L for preparation of masonry / concrete wall surfaces and applying 1mm thick wall care putty rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for preparing of old steel / metal surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing of new wooden surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of pink primer complete all as specified and as directed
M&L for preparing of new wooden surfaces of any description not exc.10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of pink primer complete all as specified and as directed
M&L for preparing of old wood / wood based surfaces of any description not exceeding 10cm in width or girth and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing of old wood / wood based surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing of old wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) complete all as specified and as directed
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil complete all as specified and as directed
M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on walls, etc. complete all as specified and as directed
M&L preparation of newly plastered / unplastered surfaces and applying three coats of white wash on ceiling, etc. complete all as specified and as directed
M&L for preparation of new masonry / concrete wall surfaces and applying two coats of oil bound distemper over a coat of wall primer including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying one coat of white wash including all necessary staging, scaffolding, etc. complete all as specified and as directed
M&L for complete removal and preparation of old decorated surfaces of ceilings, soffits, etc. by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying one coat of white wash including all necessary staging, scaffolding, etc. complete all as specified and as directed
M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying one coat of oil emulsion distemper including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying two coats of oil bound distemper over a coat of wall primer including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed
M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm over new surfaces of brickwork, concrete, etc. using roller including all necessary staging, scaffolding, etc. as required complete all as specified as as directed
M&L for or complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm using roller including all necessary staging, scaffolding, etc. as required complete all as specified as as directed
Fixing only steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed for the following bores: Note: Serviceable tubings obtained from dismantling herein before will be reused under this item
15mm bore
20mm bore
S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed of the following bores:
15mm bore
20mm bore
S&F in repairs 15mm dia bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F in repairs 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT'/'COLD', with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed
S&F in repairs 15mm dia stop cocks / angle valves, cast copper alloy, chromium plated, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
S&F in repairs 125mm dia CP shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange CP complete all as specified and as directed
S&F in repairs toilet paper holder recessed type vitreous China of approved design complete all as specified and as directed
S&F stainless steel CP soap dish, 110mm size, of approved design, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed
S&F in repairs tubular towel rail 20mm dia ‘D’ type 60cm long between flanges of aluminium anodised, including brackets complete all as specified and as directed
S&F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed
S&F in repairs for 15mm bore brass CP basin mixer, 2 in 1, of approved design, for mixing hot & cold water screwed down for iron pipe complete all as specified and as directed
S&F in repairs for 15mm bore brass CP wall mixer, 2 in 1, of approved design, for mixing hot & cold water screwed down for iron pipe complete all as specified and as directed
S&F in repairs 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed
S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing, 60cm long fixed in position with CP screws complete all as specified and as directed
S&F 12mm thick glass corner shelf, 250mm radius bewteen flanges fixed with brass chromium plated D clamps including brackets complete all as specified and as directed
S&F in repairs 32mm dia & 800mm long PVC flexible corrugated waste pipe for basin/sink, complete all as specified and as directed
S&F in repairs vitreous China squatting pan, Orissa pattern of size 580x440mm, white, with integral foot rests and 'P' or 'S' trap, connecting to flushing pipe and trap and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing complete all as specified and as directed
S&F in repairs vitreous China wash down water closet pan (Pedestal pattern), white with seat cover, closed pattern with flat bottom & cover and chromium plated mild steel or aluminum anodized hinge device and jointing and connecting up complete all as specified and as directed
S&F in repairs vitreous China wash down water closet pan fancy type, one piece, white, with seat cover, closed pattern with cover and chromium plated mild steel or aluminum anodized hinge device and jointing and connecting up complete all as specified and as directed Make: Cat No. S-220 Elegance of Hindware or equivalent of Roca, Plumber, Kohler, Jaquar
S&F in repairs wash hand basin, vitreous China, white, counter top type, of size 560x461mm, oval shaped, of approved design, with waste coupling and including PVC connection 60cm key with brass union complete all as specified and as directed
S&F in repairs wash hand basin, vitreous China, coloured, flat back type, of size 550x400mm, including CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union complete all as specified and as directed
S&F in repair plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed
S&F 10litres capacity PVC flushing tank, white / coloured, syphonic action type, low level, valveless, with PVC inlet ball valve, PVC flush pipe, float and suitable sized brackets including cutting of floor / wall and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing and taking down of old PVC flush tank and disposing off complete all as specified and as directed
S&F in repairs kitchen sink with drainage board overall size 915x460mm and bowl size 410x330x160mm, made of stainless steel 1mm thick for kitchen with plugs, washer and waste pipe including duly fixing to cantilever brackets and connection union to pipe, filling joints with wall in white cement complete all as specified and as directed
S&F in repairs stainless steel plate rack made out of 0.8mm thick stainless steel (Salem steel) of size 31''x24''x10'' with shelves, hooks, railings to keep utensil / plates both vertically and horizontaly, of approved design and type, each weighing not less than 9.25kg duly fixed with CP screws at loactions including taking down and disposing off old rusted / damaged plate rack from any position complete all as specified and as directed Note: Weight of plate racks shall be ascertained through a BOO ordered by the GE
M&L for disconnecting existing tanks of capacity exceeding 500litres to 1000litres, suitably plugging, stopping both supply and delivery connections, setting aside (or lowering if required) for other repairs, cleaning, etc. and hoisting if required and reconnecting and re-fixing in position and connecting up complete all as specified and as directed
Supplying, hoisting, fixing and connecting up 1000litres capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed
Supplying, hoisting, fixing and connecting up 500litres capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed
S&F in repairs 20mm dia ball PTMT valves, weighing minimum 455gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F in repairs 25mm dia ball PTMT valves, weighing minimum 455gm, high pressure, with high density plastic / polythene float / ball, epoxy coated aluminium rod and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed
S&F in repairs gun metal globe or gate valve, 20mm dia, with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs 110mm bore PVC (SWR) junction, single (single T) equal or unequal with or without access door complete all as specified and as directed
S&F in repairs PVC (SWR) reducers 75-110mm equal or unequal complete all as specified and as directed
S&F in repairs 110mm dia PVC (SWR) vent cowl complete all as specified and as directed
S&F in repairs 75mm dia PVC (SWR) vent cowl complete all as specified and as directed
S&F in repairs 75mm dia PVC (SWR) floor trap with chromium plated grating jointed with solvent cement complete all as specified and as directed
S&F in repair 110mm bore PVC (SWR) bend of any radius ,complete all as specified and as directed
S&F in repairs 75mm bore PVC (SWR) bend of any radius ,complete all as specified and as directed
S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
S&F PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
Supply and laying APP based polymeric membrane 3mm thick (minimum), weighting not less than 3.5 kg/sqm reinforced with polyester non woven fabric (weighting not less than 160gms/sqm) applied over primed surfaces by torching application as per manufacturer's instructions with overlaps minium 100mm on the transverse directions and 75mm in longitudinal directions complete all as specified and as directed
M&L for applying two coats of aluminium paint @0.11kg/sqm over APP membrane all as per manufacturer's instructions complete all as specified and as directed
E/M WORKS
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic PVC conduit including accessories surface on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly and making good to the surface to match the existing complete all as specified and as directed for the following:
One light point controlled by one 5A one way switch
One ceiling fan / exhaust fan point controlled by one 5A one way switch
One bell point controlled by one 5A bell push
One switch socket outlet 3 pin 5A controlled by one switch on independent board
One switch socket outlet 3 pin 5A controlled by one switch on same board
M&L for point wiring with 2.5sqmm, two single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including non-metallic PVC conduit including accessories surface on walls, ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 2.5sqmm for earth continuity conductor and connected to common earth dolly for one switch socket combination outlet 3 pin 15A multipurpose complete all as specified and as directed
M&L for point wiring with 4sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit including accessories surface on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for AC / equipment controlled by one SP/SPN MCB independent, wiring from DB to swicth socket running independently with 3 wires for each point without tapping complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 6A, 1 module, 230V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 16A, 1 module, 230V complete all as specified and as directed
S&F bell push modular type, single pole, ISI marked, one way 6A, 1 module, 230V complete all as specified and as directed
S&F socket outlet, 2/3 pin, 6A modular type, ISI marked, combined 2 module, 230V complete all as specified and as directed
S&F socket combination outlet, 2/3 pin, 6/16A modular type, ISI marked, 2 module, 230V complete all as specified and as directed
S&F electronic fan regulator, modular type, stepped type (5 steps), 120W, 230V, ISI marked duly connected up complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed
S&F bell push flush button type, 5A, 240V complete all as specified and as directed
S&F switch socket outlet, 2 in 1, 5A flush type, 3/5 pin, ISI marked, 240V complete all as specified and as directed
S&F switch socket combination outlet, 3 pin, 5 in 1, 15A flush type, universal, ISI marked, 240V complete all as specified and as directed
S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed
S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F bell buzzer, ding dong type, 230V, single pole complete all as specified and as directed
S&F in repairs the following items without disturbing existing wiring / fittings including making good the disturbed surfaces of wall/ceiling complete all as specified and as directed
Switch piano flush button type, single pole, ISI marked, one way 5A, 240V
PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V
Socket outlet, 2 in 1, 3 pin, 5A flush type, ISI marked, 240V
Switch socket combination outlet, 2 in 1, 3 pin, 5/15A flush type, ISI marked, 240V
Bell buzzer, ding dong type, 230V, single pole
LED bulb 9A
LED tube rod 20A both side connection
LED batten 20watt
LED batten mirror light 10watt
Switch piano flush modular type, single pole, ISI marked, one way 6A, 1 module, 230V
Switch piano flush modular type, single pole, ISI marked, one way 16A, 1 module, 230V
Bell push modular type, single pole, ISI marked, one way 6A, 1 module, 230V
Socket outlet, 2/3 pin, 6A modular type, ISI marked, combined 2 module, 230V
Socket combination outlet, 2/3 pin, 6/16A modular type, ISI marked, 2 module, 230V
Electronic fan regulator, modular type, stepped type (5 steps), 120W, 230V, ISI marked
S&F PVC rectangular block for mounting switches, sockets, regulators, etc. with 3mm thick plastic laminated sheet cover complete all as specified and directed of following sizes:
100x100mm and 50mm deep
175x100mm and 50mm deep
200x150mm and 50mm deep
S&F non-metallic rigid PVC casing capping 25mm wide with accessories complete all as specified and as directed
S&F heavy duty, PVC body with PVC blades, legs, AC, single phase, ISI marked energy efficient, 240V exhaust fan, 300mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts including taking down old / unserviceable fan any type and disposing off complete all as specified and as directed
S&F heavy duty, PVC body with PVC blades, legs, AC, single phase, ISI marked energy efficient, 240V exhaust fan, 250mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts including taking down old / unserviceable fan any type and disposing off complete all as specified and as directed
S&F wall mounting fan 400mm sweep, operating on single phase,230V,AC,50Hz having speed of 1400RPM, air delivery 115CNM,power ouput of 100W,5 star rated along with blade, canopy, mounting brackets, rubber insulator, complete all as specified and as directed
S&F sheet metal enclosures for 8 way MCB DB, 240V, SP, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed
S&F sheet metal enclosures for 4 way MCB DB, 240V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed
S&F sheet metal enclosures for 4 way MCB DB, 240V, SP, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed
S&F metal plug socket with MCB SP 20A, 240V enclosure for AC/equipment with neutral and earth point complete all as specified and as directed
S&F modular type 3/5 pin socket with one single pole MCB 20Amp 230V conclealed in wall suitable for geyser,AC and domestic appliances, complete all as specified and as directed.
S&F MCB TPN, 240V, 40 to 100A, 4 pole, 10kA, 'C' curve complete all as specified and as directed
S&F MCB SPN, 240V, 32A, 10kA, 'C' curve complete all as specified and as directed
S&F MCB SP, 240V, 5 to 32A, 10kA, 'C' curve complete all as specified and as directed
S&F wall mounted compact 22W LED batten type fitting, both side connection, duly connected with 3 core flexible copper conductor cable of suitable size from ceiling rose including taking down old fitting and disposing off complete all as specified and as directed
S&F wall mounted compact 20W LED batten type fitting, both side connection, duly connected with 3 core flexible copper conductor cable of suitable size from ceiling rose including taking down old fitting and disposing off complete all as specified and as directed
S&F bulk head fitting LED, 9W, IP-66 with pressure die cast housing, acrylic diffuser with frame and connecting accessories and connecting up including taking down and disposing off old fitting complete all as specified and as directed
S&F garden light, 10W, die cast aluminium housing, frosted PC diffuser, IP-65 protection calss, with inbuilt LED of aproved design with 10W LED lamp and connecting up with three core flexible copper conductor cable of suitable size including taking down and disposing off old fitting complete all as specified and as directed
S&F LED street / building security light luminaire 25W, IP-66, with driver, etc. with all accessories prewired and 25W LED lamp including service bracket complete all as specified and as directed
S&F CITY 3 decorative wall light fixtures made up of polycarbonate suitable 10watt LED (spiral B-22 base) including 1x10 watt LED lamp and all fixing arrangemen, connection, complete all as specified and as directed.
S&F 600x600mm LED type down lighter 36W with drivers connecting accessories and provision of fixing arrangements in false ceiling and connecting up including taking down and disposing off old fitting complete all as specified and as directed
S&F round shape 12/15 watt 220V, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,holders,LE lamp suitable for roof ceiling including connecting up with three core flexible copper conductor of suitable size, complete all as specified and as directed.
S&F 25W post-top lantern, opal light fitting, IP-65, new generation, energy saving, environmental friendly, 360˚ indirect light, long life aesthetically designed with symmetrical light distribution, spun aluminium luminaire with high power SMD including taking down old / unserviceable fitting and disposing off complete all as specified and as directed
S&F shock proof, rust proof pole mounting junction box, 100A rated, heavy duty of size 140x140x90mm for street lighting system with all accessories and including 1No. MCB SP 6A & 1No. MCB SP 100A heavy duty connectors, 4 terminals, with necessary mounting arrangements to pole with clamp, nut bolts, cable gland with cable entry, suitable lugs, etc. complete all as specified and as directed
S&F electric water heaters (geysers), stainless steel body, 25litres capacity, storage type, vertical mounting, with glass lined inner tank, energy efficient 5 star rated of approved design and colour, including 2kW heating element, all necessary clamps, grouting duly with holding bolts & nuts and all necessary connections at locations including taking down old unserviceable geysers of any capacity after disconnecting electric & water connections and depositing in MES store yard including all loading, unloading, carting, etc. complete all as specified and as directed
Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making god the disturbed surfaces, etc. complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing caping 20mm wide, heavy duty, ISI marked surface on wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 2 runs of 6sqmm main cable, 1 run of 4sqmm earth conductors and 1 run of PVC casing caping as per item shall be measured as one length (ii) Separate casing caping shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of casing caping shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit / casing as per requirement at site
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing caping 20mm wide, heavy duty, ISI marked surface on wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 2 runs of 4sqmm main cable, 1 run of 2.5sqmm earth conductors and 1 run of PVC casing caping as per item shall be measured as one length (ii) Separate casing caping shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of casing caping shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit / casing as per requirement at site
S&F 1100V grade heavy duty cable PVC insulated aluminium multi-stranded conductor of size 10Sqmm, served with inner sheating of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspension wire, two twin core cable flat or circular including taking down old unserviceable service connections and disposing off complete all as specified and directed.
M&L for earthing using GI earthing strip with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 25x4mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x 600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications and taking down old earthing complete all as specified and as directed
Notes for serial item No. 221: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
MS AFTAB LASKAR (BID ID -3362595)
SHRI YOUNUS KHAN (BID ID -3361861)
M/S MANIK LAL GUPTA (BID ID -3362493)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .