Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance JALALIYA BUILDING 1ST FLOOR MASJID ROAD ALUVA ERNAKULAM 683101 | ALUVA | ERNAKULAM | KERALA | 683101 | Admitted-Finance |
| 2 | Admitted-Finance 38 1067 NEAR POORNATHRAYEESA TEMPLE TRIPUNITHURA P O ERNAKULAM 682301 ERNAKULAM ERNAKULAM KERALA 682301 | ERNAKULAM | KERALA | 682301 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹33.5 L
EMD Value
₹67,014
Closing Date
17 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer(E), BSNL Elect Div, Trivandrum
O/o Executive Engineer(E), Electrical Division, BSNL Central Telephone Exchange, Trivandrum. 695001
Maintenance of EA sets in various BSNL Telephone Exchanges in Trivandrum BA for a period of one year
2022_BSNL_104277_1
12/EDT/2021-2022
Open Tender
Electrical Works
Item Rate
365 days
Trivandrum BA
As per Tender Doc
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer(Cash), BSNL, Trivandrum BA
₹67,014
Yes
11 Mar 2022
4 Feb 2022
21 Feb 2022
4 Feb 2022
17 Feb 2022
4 Feb 2022
90 days
Amount
PART A ( Preventive Maintenance) Providing preventive service maintenance of E/A sets of following capacities as per the BSNL standard maintenance scope & conditions attached. The work includes checking of all physical/functional parameters of EA set, control panel and associated accessories, dedusting the EA set, checking oil ,checking and topping up of coolant/battery water, attending faults of minor nature like minor fuel/oil/water leakages, starting failures, air locks, loose connections, servicing of starting motor/stop solenoid/ charging alternator and attending other minor electrical / mechanical complaints, checking insulation values of Alternators checking of radiator hoses and replacement if required, replacement of faulty safety fuses, overall cleaning of DG set including canopy etc. ( where ever suitable spare items are not available, the spares from shut down/ scrapped DG sets of BSNL can be reutilised as per technical feasibility, availability and with the permission of site in charge without any extra cost)
Note-1. Periodic preventive maintenance site visit shall be done once in three months.However, breakdown maintenance during this period shall be promptly attended as per the terms and conditions of the agreement and cost of spares not covered in the above item No.1 will be paid extra
Note-2. Items not included under the scope of the preventive maintenance are included as per Part B and C of this schedule.
Note-3. For any unforeseen major works/service /accessories for which rates are not stipulated in this agreement that may arise during the period of this contract, for such works,BSNL will make necessary arrangement as per prevailing norms
Note-4. This item is for DG sets working in Manual condition and for sets which are brought to manual working condition by executing this item. The DG sets which needs to run in manual condition will be continued in this item. Other sets to be made in to auto condition at the earliest possible by utilising the items available in items A, B &C. of this schedule. The preventive maintenance of a particular EA set commences when it is in working condition / made in to working condition and first service shall be recorded as first measurement. once executed, the interval for the next service shall be after 3 months.
Above 10 KVA and up to 15 KVA (per site once in three months)
Above 15 KVA and up to 30 KVA (per site once in three months)
Above 30 KVA and up to 40 KVA ((per site once in three months))
Above 40 KVA and up to 63 KVA ((per site once in three months))
Above 63 KVA and up to 100 KVA ((per site once in three months))
Above 100 KVA and up to 160 KVA ((per site once in three months))
Above 160 KVA and up to 250 KVA ((per site once in three months))
Above 250 KVA and up to 350 KVA ((per site once in three months))
Above 350 KVA and up to 500 KVA ((per site once in three months))
Providing periodical preventive maintenance of E/A sets withAMF panel of following capacities as per the BSNL standard maintenance scope & conditions attached. The work includes checking of all physical/functional parameters of EA set, AMF control panel and associated accessories, and dedusting the EA set, checking of oil ,checking and topping up of coolant/battery water, attending faults of minor nature like minor fuel/oil/water leakages, starting failure, air locks, loose connections, servicing of starting motor/stop solenoid/charging alternator and other minor electrical / mechanical complaints, checking insulation values of Alternators checking of radiator hoses and replacement if required, replacement of faulty safety fuses, overall cleaning of DG set including canopy etc. ( where ever suitable spare items are not available, the spares from shut down/ scrapped DG sets can be utilised as per technical feasibility, availability and with the permission of site in charge without any extra cost)
Note-1. Periodic preventive maintenance site visit shall be done once in three months.However, breakdown maintenance during this period shall be promptly attended as per the terms and conditions of the agreement and cost of spares not covered in the above item No.1 will be paid extra
Note-2. Items not included under the scope of the preventive maintenance are included as per Part B and C of this schedule.
Note-3. For any unforeseen major works/service /accessories for which rates are not stipulated in this agreement that may arise during the period of this contract, for such works,BSNL will make necessary arrangement as per prevailing norms
Note-4. This item is for DG sets which are in Auto mode and sets which were made in auto mode by migrating from item No.Part A.1 or after getting repaired using items available in this agreement. The preventive maintenance of a particular EA set commences when it is in working condition / made in to working condition and first service shall be recorded as first measurement. Once executed, the interval for the next service shall be after 3 months.
Above 10 KVA and up to 15 KVA ((per site once in three months))
Above 15 KVA and up to 30 KVA ((per site once in three months))
Above 30 KVA and up to 40 KVA ((per site once in three months))
Above 40 KVA and up to 63 KVA ((per site once in three months))
Above 63 KVA and up to 100 KVA ((per site once in three months))
Above 100 KVA and up to 160 KVA ((per site once in three months))
Total for Part A
Part A (Total 98 DG sets taken ( Non AMF DG 65+ AMF DG 33) at an average 4 visits/ DG in an Year). (One no 15 KVA EA set, considered for manual in Ist Phase and in AMF in later stage).
Part B: Consumables (Oil Servicing and Batterries )
This item to be executed only where ever required and as per the instructions of engineer in charge
Carrying out oil servicing of following capacity EA set i/c draining the existing lub oil and supplying and filling of superior quality and suitable grade for the engine lub oil ( 15 W 40 grade ), replacing of fuel filters, lub oil filters etc complete as per the maintenance schedule, terms and conditions and specifications attached.
Above 10 KVA and up to 15 KVA
Above 15 KVA and up to 30 KVA
Above 30 KVA and up to 40 KVA
Above 40 KVA and up to 63 KVA
Above 63 KVA and up to 100 KVA
Above 100 KVA and up to 160 KVA
Above 160 KVA and up to 250 KVA
Above 250 KVA and up to 350 KVA
Above 350 KVA and up to 500 KVA
Note :The oil servicing of the EA sets has to be done once in a year or at 250-500 hours or as reccomended by the OEM as per direction of Engineer in charge. ( In case of oil change required before the said period like idleness of EA set or any other fault, the same may be done with the approval of Engineer in charge of the station). The date of changing of oil and hours may be recorded in Log Book.
Providing 12Volts Lead acid batteries of following capacities of automotive duty with Minimum 36 months Warrantee suitable for BSNL EA sets in fully charged condition for replacing of faulty batteries which are life expired/ damaged. (Make :BSNL approved makes). The date of installing battery and site name to be written with permanent marker on battery without erasing bar code. Also details to be entered in DG log book also, Interchanging batteries to be avoided and if any reqd to be noted in log book. The warrantee card with dated seal and site name to be submitted to Engineer In charge ( No buy back and dismantled battery shall be handed over to site in charge)
NOTE: Faulty Batteries whose life has exceeded 3 years /in damaged condition/ not in good condition due to prolonged non usage are included in the scope of this item. For batteries less than 3 years and in good condition at the time of taking over, the date of previous installation of battery shall be noted by the agency, countersigned by Engineer in charge of the station and note the same in DG Log book. The site code and date shall be noted with permanent marker on battery during taking over and during new installation. In such sites, the agency shall arrange spare service battery, free of cost till expiry of above 3 years or contract period whichever is earlier.
Total for Part B
PART C : Supply and fixing of Spares
Note:1: This item to be executed only where ever required and as per the instructions of engineer in charge. As far as possible the DG sets to be made in to working condition utilising items in Part A & B.
Replacement of faulty Microprocessor based AMF Controller with new one suitable for the required capacity single/ three phase EA sets compatible for Water/Air cooled Engine in the existing AMF control panel including disconnecting and dismantling the faulty one, including providing and fixing all accessories , making necessary wiring arrangements, providing necessary support with hylum sheet./ metallic sheet so as to avoid water entry, including functional testing and commissioning with 1 year warrantee and as per site conditions and specifications attached. (Make:SIAS /Deep sea/Bernini/C&S)
Replacement of faulty 4 Pole Power contactor of following ratings, of suitable voltage i/c dismantling the item, giving connection , testing and commissioning as reqd. AC-1 Rating (Make:L&T MCX type / Schneider Electric/ Siemens/Telemecanique), Add block to be provided where ever reqd. ( Irrespective of EA set KVAs shown ; in sites where existing contactor of same rating only is fesaible, higher ratings can be permitted, to avoid replacing both EB and DG contactors )
50 A contactor ( up to 30 KVA EA sets)
63A contactor ( > 30KVA up to 50 KVA)
100A contactor (>50KVA-63KVA)
130A Contactor ( >63 KVA-125 KVA)
Replacement of faulty contactor kit/ coil of suitable voltage for the existing Contactor of up to 63A i/c dismantling the item, giving connection , including testing and commissioning as reqd. (Make:M/s L& T / Schneider Electric/ Siemens/ Telemecanique/ Similar superior makes)
L&T MCX 11/ SS make contactor kit
L&T MCX 12/ SS make contactor kit
L&T MCX22 / SS make contactor kit
L&T MCX23 / SS make contactor kit
L&T MCX 11/ SS make contactor coil
L&T MCX 12/ SS make contactor coil
L&T MCX22 / SS make contactor coil
L&T MCX23 / SS make contactor coil
Rewinding of faulty starting motor with copper conductor including baking / heating varnishing etc as reqd,of EA sets upto 63 KVA etc as reqd
For EA sets upto 30 KVA
For EA sets>30 KVA upto 63 KVA
For EA sets>63 KVA upto 125 KVA
For EA sets >125 KVA upto 250 KVA
For EA sets>250 KVA upto 500 KVA
Replacement of faulty Battery charger unit with new one, SMPS based ,Horizontal mounting type, input voltage 170-260 V AC,50 Hz ,Output 12 V DC, 10 A suitable for Battery including mounting, making connections ,testing and commissioning as required. (One Year warranty)
Replacement of faulty Battery charger unit with new one, SMPS based ,Horizontal mounting type, input voltage 170-260 V AC,50 Hz ,Output 24 V DC ,20 A suitable for Battery including mounting, making connections , testing and commissioning as required. (One Year warranty)
S/F of the following spares for the E/A set and panels for the smooth functioning of the system i/c checking the items and replacing the faulty one. giving necessary connections testing and commissioning etc as reqd.
LVM relay
START/STOP push button
START/STOP relay
Electronic hour meter
Analogue hour meter
Analogue RPM Meter
Rpm cum hour meter
Fuel gauge
V belt suitable for DG up to 63 KVA
V belt suitable for DG >63 KVA
12V ,Stop solenoid suitable for TE DG sets with various capacities and having one Batterry ( one year warranty)
24V ,Stop solenoid suitable for TE DG sets with various capacities and having two Batterry ( one year warranty)
32 Amps ," c " series ,TP , MCB
32 Amps ," c " series ,4P , MCB
32 Amps ," c " series , DP , MCB
10 Amps ," c " series , DP , MCB
63A ,4P ,2way + off,Changeover switch
Add on block (2NO+ 2NC)
Diesel Metalic braided flexible pipe lenth up 1Mtr
Diesel Metalic braided flexible pipe lenth above 1 Mtr and up to 2Mtr
Copper batterry cable ( one pair)
Copper sockets of battey cable (one pair)
LLOP sensor
HCT/HWT sensor
12 V /24 V OEN/Pla relay plug in type
Electronic AVR suitable for EA set up to 63 KVA ( one year warranty)
Electronic AVR suitable for EA set above 63 KVA to 250 KVA ( one year warranty)
Electronic AVR suitable for EA set above 250 KVA to 500 KVA ( one year warranty)
Mechanical interlock kit for contactors up to 80A (L&T MCX 11 to 13 / similar makes)
Mechanical interlock kit for contactors from 100A to 255A (L&T MCX 22 to 34/ similar makes)
63A ,4P,MCCB ,30KA breaking capacity .(Make L&T/SS)
415 Volts 4 Pole 63A Onload change Over Switch without enclosure i/c replacing the faulty (HPL / SS make)
415 Volts 4 Pole 125A Onload change Over Switch without enclosure (HPL / SS make
415 Volts 4 Pole 63A Onload change Over Switch with enclosure i/c replacing the faulty (HPL / SS make)
415 Volts 4 Pole 125A Onload change Over Switch with enclosure (HPL / SS make )
415 Volts 4 Pole 63A SDF with 50A HRC Fuse without enclosure i/c replacing the faulty one etc as reqd. (HPL / L&T/ SS make)
415 Volts 4 Pole 125A SDF with 100A HRC Fuse without enclosure (HPL / L&T/ SS make)
415 Volts 4 Pole 63A SDF with 50A HRC Fuse with enclosure i/c replacing the faulty one etc as reqd. (HPL / L&T/ SS make)
415 Volts 4 Pole 125A SDF with 100A HRC Fuse with enclosure (HPL / L&T/ SS make)
S/F of Generator Protection unit suitable for DG sets up to 40 KVA (SIAS- SUN/ C&S/SS make)
S/F of Generator Protection unit suitable for DG sets > 40 KVA up to 125 KVA (SIAS- SUN/ C&S/SS make)
Supplying and fixing rubber type AVM pad suitable up to 30 KVA EA set , by lifting /raising the engine from base , dismatling the faulty one ,fixing ,testing,comissioning etc complete as required.(Make : Polybond/s.s make ) (rate per piece)
Supplying and fixing horse shoe type AVM pad suitable for Dg set > 30 KVA and up to 63 KVA EA set , by lifting /raising the engine from base , dismatling the faulty one ,fixing ,testing,comissioning etc complete as required.(Make : Polybond/s.s make ) (rate per piece)
Reparing of existing AMF controller with help of respective OEM ,to and fro transportation ,giving connection ,testing etc as required
Repairing of existing 12/24 Vollt battery charger as required .
Repairing of fuel injector of fuel injection pump as required(Rate is for servicing of each injector )
Dismantling of existing 88/100/130/150/180 AH lead acid battery ,re-charging the battery by replacing the acid ,to and fro transportation ,re-fixing the same as required .
Supplying and Fixing 380mm sweep heavy duty fresh air fan in the existing KVA DG set canopy i/c providing necessary clamping arrangement ,nuts ,bolts ,giving connection etc complete as required .(Make : Almonard /s.s make )
Rewinding of 250/380mm sweep heavy duty fresh air fan /exhaust fan in the existing up to 30 KVA DG set canopy i/c to and fro transportation ,fixing etc as required
Replacing Blower fan bearing afrer removing existing one
Supplying and laying 4x25 Sq: mm aluminum conductor armoured cable 1.1 KV rating in surface /pipe /loose in panel for connecting between DG and panels with gland, lugs etc where ever reqd as required .
Supplying and laying 3 1/2 x 50 Sqmm aluminum conductor armoured cable 1.1 KV rating in surface /pipe /loose in panel for connecting between DG and panels with gland, lugs etc where ever required .
Laying and fixing of one number PVC sheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required. Above 35 up to 95 Sq mm Cable ( Cable will be supplied from BSNL Stores)
Supplying and filling 15 W40 engine oil suitable for various capacity engine as required.( for using in sites where only top up is reqd during first visit )
Providing hinges for the canopy door/ rapairing the same so as to close the door of canopy, painting the repaired portion with anticorrosive paint etc as reqd ( Per hinges)
Attending to roof leak of DG canopy by fixing tar sheet on roof, after cleaning the surface and applying one coat of anti corrocive paint etc as reqd.
Arranging of accoustic DG sets on daily rental; basis of different capacities as per the loads required in sites in trolley mounted/ platform mounted sets with required safety and technical requiremets, including connecting the cable to control panel inside BSNL sites for using in times of Dg failures/ contigencies up to minimum 1 day and maximum of 5 days in a site ( specific approval of competant authority needed for further extension and diesel will be supplied by BSNL) The operating procedure shall be trained to the person deputed by BSNL for opearting the DG set. The capacity will be initmated by BSNL and shall be minimum and sufficient to meet the load requirement of site.
up to 30 KVA EA set
> 30 KVA to 63 KVA EA set
> 63 KVA to 125 KVA EA set
> 125 KVA to 300 KVA EA set
Total for Part C
Total for Part A + Part B +Part C
ELECTROTEK ENGINEERS PVT LTD
REGI ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .