Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64,203Accepted-AOC | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | Nidheesh P L1 |
|---|---|---|---|---|
| 1.00ELETRIFICATION | ||||
| 1.00 | OD160757/2024-2025:Supply installation of ISO certified pure sine wave Inverter with the following specifications, a. Capacity: 2 KVA b. Input voltage range 140-280 Volts AC Single phase c.Out put voltage : 230V/50Hz AC Voltage regulation +/-1% d. Wave form: True sine wave e. Indicators: Mains on, Inverter on,Battery on charger,Over load f. Battery:C Tubular C10 series 100AH- 2 no with painted angle iron non corrossive rack for keeping the battery. g. Warranty : 2 Year on site warranty for inverter and 3 year Warraty for tubular battery. | 1 | each | 43,570.63 ₹43,570.63 Lowest |
| 1.00 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | 22 | metre | 219.07 ₹4,819.54 Lowest |
| 1.00 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 50 | metre | 101.21 ₹5,060.5 Lowest |
| 1.00 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | 5 | metre | 192.17 ₹960.85 Lowest |
| 1.00 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 51 | metre | 136.51 ₹6,962.01 Lowest |
| 1.01 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door | 1 | each | 2,462.52 ₹2,462.52 Lowest |
| 1.01 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 462.5 ₹462.5 Lowest |
| 1.01 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 7 | each | 272.25 ₹1,905.75 Lowest |
| 1.01 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) | 1 | each | 365.24 ₹365.24 Lowest |
Tender Value
₹68,258
EMD Value
₹1,706
Closing Date
28 Oct 2025, 6:00 pmClosed
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
GENERAL-Govt. Ayurveda Hospital Mattool SITC of Inverter- SITC of Inverter at Govt. Ayurveda Hospital Mattool--General Electrical Work
2025_PWD_796612_2
PWD/BLDG/TR/18001/2024_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
₹1,706
19 Aug 2026
21 Oct 2025
31 Oct 2025
21 Oct 2025
28 Oct 2025
21 Oct 2025
Amount
ELETRIFICATION
OD160757/2024-2025:Supply installation of ISO certified pure sine wave Inverter with the following specifications, a. Capacity: 2 KVA b. Input voltage range 140-280 Volts AC Single phase c.Out put voltage : 230V/50Hz AC Voltage regulation +/-1% d. Wave form: True sine wave e. Indicators: Mains on, Inverter on,Battery on charger,Over load f. Battery:C Tubular C10 series 100AH- 2 no with painted angle iron non corrossive rack for keeping the battery. g. Warranty : 2 Year on site warranty for inverter and 3 year Warraty for tubular battery.
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
Bidder Name
Nidheesh P
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1358566.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
MOM.pdf
Tender Documents • 0.20 MB
BOQ_1358566.xls
BOQ • 0.31 MB
viewnit.pdf
Tender Documents • 0.02 MB
viewsbd.pdf
Tender Documents • 2.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .