Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹22.6 L+₹1.9 L (9.19%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹23.7 L+₹3.0 L (14.5%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Sept 2023, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIRS / REPLACEMENT OF INTERNAL WIRING, SUBMAIN WIRING, DBs AT MD ACCN AT MAKARPURA AT AFS BARODA
2023_MES_612299_1
8822/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹50,000
Yes
8 Nov 2023
5 Aug 2023
11 Sept 2023
5 Aug 2023
4 Sept 2023
21 Aug 2023
7 Aug 2023 - 14 Aug 2023
Amount
Taking down carefully copper / Aluminium point wiring of light, fan, socket or power points complete including fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical, fan regulators, light or power sockets etc and removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
Material and labour for point wiring with using 2x 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated(FRLSH) & unsheathed cable, 1100 volts grade as per IS 694 for Phase and Neutral, 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated (In Green colour)& unsheathed cable as in earth wire connected to common earth dolly in existing concealed PVC conduit any type as per site requirement of suitable size all as specified and directed with and including providing new SS sunken box and Moduler cover plate for fixing of switch socket, fan regulators etc and incl all accessories complete all as specified and directed for the following :-
Note for item No 2.00 : (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
One light or fan point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet on same board with other switches.
One 3 pin 5 Amps socket outlet on independent board.
One bell point controlled by one bell push
One light point controlled by two, two way switches
Description all as per item No. 2.00 here-in-before but using 2.5 Sqmm PVC insulated, unsheathed copper conductor cable and earth conductor of 2.5 sqmm copper cable for one 3 pin socket outlet 15 Amps on independent board. Note:- (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
Material and labour for concealed point wiring with using 2 x 1.5 Sqmm (nominal area) stranded copper conductor single core, PVC insulated (FRLSH) & unsheathed cable, 1100 volts grade as per IS 694 for Phase and Neutral, 1x 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated (In Green colour)& unsheathed cable as in earth wire connected to common earth dolly in concealed rigid PVC conduitsize not less then 20mm dia as per site requirement of suitable size all as specified and directed with and including providing new SS sunken box and Moduler cover plate for fixing of switch socket, fan regulators etc and incl all accessories complete all as specified and directed for the following :-
Note for item No 4.00 : (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
One light or fan point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board.
One light point controlled by two, two way switches
One bell point controlled by one bell push
Description all as per item No.4.00 here-in-before but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board. Note (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
Note: (for item 01 to 05): Being maintenance work Contractor shall carry out even single point wiring or associated work as per the direction of concerned JE(E/M)/AGE E/M. In case contractor fails to execute the allocated work within 3 days from the date of allocation a recovery at the dauble of quoted rate shall be levied upon contractor and no claim whatsover on this account shall be entertained by the Government.
M&L for point wiring with using 1.5 Sqmm (nominal area) stranded copper conductor single core PVC insulated & unsheathed cable 1100 volts grade in and incl PVC casing and caping of suitable size fixed on surface all as directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for the following:-
Note for item No 6.00 : (i) The quoted rates shall deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
One light or fan point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board.
One light point controlled by two, two way switches
One bell point controlled by one bell push
Description all as per item No.6.00 here-in-before but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board. Note (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
M & L for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 6 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 6 sqmm and one run of 6 sqmm earth wire and one run of PVC conduit casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the quoted rate.
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping / PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 4 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm earth wire and one run of PVC conduit casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
M & L for sub main wiring using two single core 2.5 Sqmm ZHFR PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 2.5 Sqmm earth wire, ZHFR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 2.5 sqmm and one run of 2.5 sqmm cable and one run of PVC conduit casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
S & F switch piano Modular type single pole one way 6 Amp 240 Volts complete all as specified and directed.
S & F switch piano Modular type single pole one way 16 Amp 240 Volts complete all as specified and directed.
S & F switch piano Modular type single pole two way 6 Amp 240 Volts complete all as specified and directed.
S & F socket outlet 6 Amps 2 in 1 with Shutter Modular type 240 Volt complete all as specified and directed.
S & F socket outlet 6/16 Amps Twin Socket Modular type 240 Volt complete all as specified and directed.
S & F Bell push switch Modular type single pole one way 10 Amp 240 Volts complete all as specified and directed.
S & F Fan Regulator 1/2 Module FSC Modular type 240 Volts complete all as specified and directed.
S&F piano switch flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified & directed.
S&F piano switch flush type 15 Amps single pole, one way 230 volts AC circuit complete all as specified and directed
S&F bell push, 6 Amps, flush type, 230/250 Volts, 50 Hz supply complete all as specified and directed.
S&F socket out let 2 in 1, 3 pin 5 Amps flush type, 230 volts Ac circuit complete all as specified and directed.
Supply and fixing stepped type fan regulator flush type 01/02 Module both on the existing phenolic laminated sheet etc complete all as specified and directed
S&F ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed.
Supply and fixing wall mounted light fittings suitable for retrofit LED lamp upto 14 watt B22 champagne gold finish fixture with plastic body, Opal white PC diffuser for glare free light complete all as specified and directed.
S&F door bell ding dong, multi tune, Chime and Buzzer complete all as specified and directed.
Supply and fixing new indoor decorative channel housing fitting slim LED batten 20 Watt with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with suitable size copper conductor flexible cable from ceiling rose to connector of the light, fixing the same with two Nos PVC square box complete all as specified and directed.
Attending the complaints lodged by the occupants/users including Identifying and rectifying of electrification nature & rectification of the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs in respect of main fixture /breakdown for light/fan/bell/light or power socket and LT line etc complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/ Exhaust fans and other type of complaints to connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and respect of item if required to be paid under respective item as required complete all as specified and directed
Attending the complaints lodged by the occupants/users including Identifying and rectifying of electrification nature & rectification of the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs like taking out old unserviceable item and fixing of Switches, sockets, regulators, Ceiling rose, Bell push, lamp holder, laying of wire all any type complete all specified and directed
Attending the complaints lodged by the occupants/users including Identifying and rectifying of electrification nature & rectification of the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs like fixing of LED Batten any size, T-08 Fittings, LED 2X2 Recess mounting lights, PVC Conduit fixing any size etc complete all as specified and directed
Attending the complaints lodged by the occupants/users including Identifying and rectifying of electrification nature & rectification of the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs like fixing of MCBs, Ceiling fans, Wall Fans, Exhaust Fans, and DBs etc complete all as specified and directed
Attending the complaints lodged by the occupants/users including Identifying and rectifying of electrification nature & rectification of the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs No light complaint, loose wire, sparking etc in LT panel at AFS Makrpura and all HT LT fault emergency complaint and any type of complaint regarding electricity complete all as specified and directed
NOTE FOR ITEM NO 27.00 to 31.00:- (a) All T & P/Stationeries and labour team required comprising of sufficient trained technician (Electrician / helper ) will be provided by the contractor daily for two location ie harni camp and harni airfield Baroda area as directed. During MES mela or any other occason the contractor will require to be arrage additional menpower to rectify the complaint within justified time. b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 17.30 Hrs the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor.
NOTE FOR ITEM NO 27.00 to 31.00:- (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size, lubricating oil/grease etc shall be deemed to be included in the above quoted rate. However, major items such as switches, sockets, bell push, fan regulator, capacitor, wires etc shall be measured and paid separately under appropriate items of BOQ. (d) Complaints pertains to complete replacement of circuit/point wiring shall be measured under relevent item. (e) If contractor fails to rectify the complaint with in 24 hours after receiving, Rs 500/- per complaint will be penalised.
Load balancing on three phase DBs of buildings including checking of load by using amp meter/tong tester rearranging the connections within the DBs and providing copper lugs with wires tightening of all connection and testing and verify the load current on each phase in persence of JE E/M/ Engr-in-charge complete all as specified and directed
Checking/testing of Earth resistance value of earthing pits Installed inside harni camp and Makarpura Area as per requirement basis as directed by Engr in Charge or as scheduled and making the damaged earthing serviceable by pouring salted water into earthing or making continuity by GI strips and bringing down the resistance value within specified limits including maintenance of existing earthing by cleaning the earth chamber funnel and cleaning of vagetation surrouding earthing pit up to 2 mtr complete all as specified and directed
Note for item No 33.00 (i) The entire station will be divided into two zones as per earthing location and the contrcator will deploy separate team for each zone to test the resistance value of earthings in each zone to complete the process within one month. The entire process will be repeated after every six months (half yearly) upto completion of the contract. (ii) one earth testing in one season shall be measured as one job. (iii) Digital Earth tester will be arrange by the contractor. (iv) Date of testing and due date of testing is to be written on a register with sign of user rep & Engr-in-Charge and will be submitted to GE. (iv) Testing and correction action is to be done within one month from date of commencement i.e. approx 120 earthings is to be completed within one month. Thereafter on half yearly basis or as directed by Engr-in-charge and same is to be completed within one month. The contractor has to deploy electrician with helper and testing equipment and all the resources to complete the task within one month. (v) If any material required for improvement of resistence value where value is more than their permissible limit will be measured and paid seperately.
Supply only switch piano Modular type single pole one way 10 Amp 240 Volts complete all as specified and directed
Supply only switch piano Modular type single pole one way 16 Amp 240 Volts. complete all as specified and directed
Supply only switch piano Modular type single pole two way 10 Amp 240 Volts complete all as specified and directed
Supply only socket outlet 10 Amps 2 in 1 Socket with Shutter Modular type 240 Volt complete all as specified and directed
Supply only socket outlet 6/16 Amps Twin Socket Modular type 240 Volt complete all as specified and directed
Supply only Bell push switch Modular type single pole one way 10 Amp 240 Volts.complete all as specified and directed
Supply only Fan Regulator 1/2M FSC Modular type 240 Volts. complete all as specified and directed
Supply only piano switch flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified and directed
Supply only bell push, 6 Amps, flush type, 230/250 Volts, 50 Hz complete all as specified and directed
Supply only piano switch flush type 15 Amps single pole, one way 230 volts AC circuit complete all as specified and directed
Supply only socket out let 2 in 1, 3 pin 5 Amps flush type, 230 volts Ac circuit complete all as specified and directed
Supply only socket out let 2 in 1 multi purpose three pin, 15 Amps & three pin 5 Amps controlled by one switch, flush type 230 volts AC circuit complete all as specified and directed
Supply only Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed
Supply only Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and directed
Supply only stepped type fan regulator flush type 01/02 Module both on the existing phenolic laminated sheet etc complete all as specified and directed
Supply only ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed
Supply only lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed
Supply only door bell ding dong, multi tune, Chime and Buzzer complete all as specified and directed
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 3 module with white cement concealed and making good the disturbed surface as per existing complete all as specified and directed Note:- Cost of labour paid separatly.
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 4 module with white cement concealed and making good the disturbed surface as per existing complete all as specified and directed Note:- Cost of labour paid separatly.
Supply only Concealed Galvanised (GI) metal flush Boxes Modular 6 module with white cement concealed and making good the disturbed surface as per existing complete all as specified and directed Note:- Cost of labour paid separatly.
Supply only white cover plates with frame (white) Modular type 2 way complete all as specified and directed
Supply only white cover plates with frame (white) Modular type 3 way complete all as specified and directed
Supply only white cover plates with frame (white) Modular type 4 way complete all as specified and directed
Supply only white cover plates with frame (white) Modular type 6 way complete all as specified and directed
Supply only white cover plates with frame (white) Modular type 8 way complete all as specified and directed
Supply only sheet metal enclosure SP with two pin and socket with one single pole MCB 25 Amps, 'B Curve 240 Volts complete all as specified and directed
Supply only metal clad plug top and socket of any description of 25 Amp 3 pole 230 volts complete all as specified and directed.
Supply only LED security light luminaire 30 watt freedom , pressure die cast aluminum housing, heat resistant glass, IP66 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and directed
Supply only LED batten 10 Watt (Mirror Light) 2 Feet with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same complete all as specified and directed
Supply only LED batten 20 Watt with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same complete all as specified and directed
Supply only LED light fitting recess mounted/pendent mounting ultraslim LED flat panel 2x2 down light aluminium extruded housing with full opal diffuser IP 20 suitable for perfect lighting condition 36 watt 240 volt, 50 Hz AC supply complete all as specified and directed
Supply only MCCB four pole 63 amps 25 KA 415 Volts complete all as specified and directed
Supply only MCB four pole 63 amps 10 KA 415 Volts C series complete all as specified and directed
Supply only MCB, single pole 240 volts 6 to 32 Amps capacity C series fixed in DB's. complete all as specified and directed
Supply only MCB, single pole and neutral link 240 volts 6 to 32 Amps capacity C series fixed in DB's. complete all as specified and directed
Supply only MCB, single pole 240 volts 40 to 63 Amps capacity C series fixed in DB's. complete all as specified and directed
Supply only MCB, single pole and neutral link 240 volts 40 to 63 Amps capacity C series fixed in DB's. complete all as specified and directed
Supply only of PVC conduit size 25mm Rigid non-metallic PVC conduit exclusive of boxes (junction /terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth, tube ends and fixing accessories, including chase cutting, such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed
Supply only LED bulb 09 Watt 5 star rating complete all as specified and directed
Supply only FR-LSH PVC insulated, unsheathed, single core, flexible copper conductor wire suitable upto voltage grade 110 volt of different colours and following sizes complete all as specified and directed
Supply only 2.5mfd capacitor suitable for ceiling fan complete all as specified and directed
Supply only ceiling fan 1200 mm 5 star rating metallic white, dust resistant with remote control complete all as specified and directed Make- Havells CAT PART NO.- Efficiencia (BLDC) 32 Watt or equivalent in Crompton
Supply only wall mounted fan 400 mm 5 star rating Hi-Speed metallic white, dust resistant with remote control complete all as specified and directed Make- Havells CAT PART NO.-Aindrila Premium or equivalent in Crompton
Supply only exhaust fan, steel body heavy duty turboforce, AC single Phase. 230 V of size 300mm sweep, 1400 RPM air delivery 1950 CM with, 4 blades, and frame and louvers gray colour, dust resistant. complete all as specified and directed Note: all necessary arrangement such as wodden frame/cut in existing window frame/or making hole and making good the disturbed surfaces of wall as per existing is included in quoted rates.
Supply only exhaust fan, steel body heavy duty turboforce, AC single Phase. 230 V of size 450mm sweep, 1400 RPM air delivery 1950 CM with, 4 blades, and frame and louvers gray colour, dust resistant. complete all as specified and directed Note: all necessary arrangement such as wodden frame/cut in existing window frame/or making hole and making good the disturbed surfaces of wall included in quoted rates.
Supply only exhaust fan 300mm sweep, made of sturdy engineering plastic, excellent impact and abrasion resistance, Rated Speed 1000 revolution per minute, blade design Aerodynamically designed & Balanced Blade;Operating Voltage: 230 volts, Speed: 1350 RPM ; Number of blades: 5. Noise level:42 dB complete all as specified and directed
Supply only exhaust fan 150mm sweep, made of sturdy engineering plastic, excellent impact and abrasion resistance, Rated Speed 1350 revolution per minute, blade design Aerodynamically designed & Balanced Blade Operating Voltage: 230 volts, Speed: 1350 RPM ; Number of blades: 5. Noise level:42 dB complete all as specified and directed
M & L for Making hole in wall for Exhaust fan of dia 300mm and providing hume pipe and making good the disturbed surface to match with existing complete all as specified and directed.
S&F Exhaust fan louvers steel body for 300 mm sweep in replacement complete all as specified and directed.
Supply and fix in repairs MCB DB 4 way (VTPN) vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified and directed Note : (i) Copper thimble shall be used for connection of cable . (ii) MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule.
S & F in repairs MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directed Note : Copper thimble shall be used for connection of cable.
Description all as per item No 85.00 here-in-before but 8 way.
Description all as per item No 85.00 here-in-before but 12 way.
S & F of PVC conduit size 25mm Rigid non-metaLlic PVC conduit exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mount tube ends and fixing accessories including chase cutting such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
M & L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and aking good, cutting exceeding 20cm girth complete all as specified and directed
M & L for rewinding of ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leatherite sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed Note:- Contractor shall make the suitable arrangement at Darjipura (MES) premises to replacing of accessories, testing upto the satisfactory level in front of concerned E/M in charge without fail.
M&L for changing of fan bearing 6201/6202 of ceiling fan of any capacity any size complete all as specified and directed Note: Replacement of bearing to be carried out at power house at AFS Darjipura only exceptional case where lathe work is required then only fan to be taken at workshop.
M & L for rewinding of Exhaust fan 300 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
M & L for rewinding Exhaust fan 450 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
ARTI CONSTRUCTION
Badri Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .