Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | ₹23.6 L Quoted ₹23.9 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹28.0 L+₹4.1 L (17.2%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | ₹28.0 L+₹4.1 L (17.2%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹30.1 L+₹6.2 L (26.0%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | ₹30.1 L+₹6.2 L (26.0%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹30.2 L+₹6.3 L (26.4%)Rejected-Finance | ₹30.2 L+₹6.3 L (26.4%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹31.1 L+₹7.2 L (30.2%)Rejected-Finance | ₹31.1 L+₹7.2 L (30.2%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
30 Aug 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
REPAIR / ROUTINE MAINTENANCE OF FIRE FIGHTING SYSTEM / FIRE ALARM SYSTEM, EOT CRANE, DG SET AND ALLIED WORKS AT INS SARDAR PATEL, NAUSENA BAGH AND NOFRA UNDER GE NAVY PORBANDAR
2022_MES_542049_1
9138/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹54,000
Yes
16 Sept 2022
30 Jul 2022
31 Aug 2022
30 Jul 2022
30 Aug 2022
13 Aug 2022
30 Jul 2022 - 12 Aug 2022
Amount
Labour for Repair/Servicing /Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 250 KVA, Model :- 6SL8800TA (Make - Kirloskar) . Checking throughly the Generator and finding out its faulty/defective parts and complete servicing /replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule - 02 Nos at Nausena Bagh.
KOEL CARE Super Genuine Oil 13 Liters CAN
SPINON LUBE OIL FILTER
FUEL FILTER,1.1 LIT,TWIN BOWL
KOEL CARE GENUINE COOLANT PREMIX 5 LITRE CAN
16"AIR CLEANER PRIMARY ELEMT
ROFAN AUTOMOTIVE V-BELT (AVX 13 X 1562 LENGTH) Part no. F6.019.16.0.00
ANTIVIBRATION MOUNT RR400 HEIGHT 72MM PART NO F6.126.02.0.00
BATTERY CABLE ASSEMBLY 21 SQ.MM
FUEL PIPE ( RETURN ) M12 X 1.5 MALE PLUG X M14 X 1.5 BANJO ( 700 MM )
RUBBER HOSES (TGL 13880 40LG)
PIPE (FROM THERMOSTAT COVER TO RADIATOR)
HOSE FOR THERMOSTAT TO WATER TANK.
STICKER KIRLOSKAR GREEN POWER IDEAS 420X450MM.
KIRLOSKAR GREEN BRAND STICKER 5M LENGTH.
LEFT HAND LOCK WITH CATCHER ( 100 TO 600 KVA)
VENT CONNECTION HOSE.
HOSE FOR AIR CLEANER.
AMARAON BATTERY 12 V/130AH
M & L for FIP Calibration Suitable for Engine of Model 6 SL 8800TA
M & L for FIP Overhaul Suitable for Engine of Model 6 SL 8800TA
M & L for Injector Calibration & Pressure Testing Suitable for Engine of Model 6 SL 8800TA
M & L for Injector Overhaul Suitable for Engine of Model 6 SL 8800TA
M & L for Starter Servicing Suitable for Engine of Model 6 SL 8800TA
M & L for Charging Alternater Servicing Suitable for Engine of Model 6 SL 8800TA
M & L for Radiator Servicing Suitable for Engine of Model 6 SL 8800TA
Labour for Repair/Servicing /Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 125 KVA, Model :- 4K1080TA1 (Make - Kirloskar) . Checking throughly the Generator and finding out its faulty/defective parts and complete servicing /replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule.- 03 Nos DG sets at Nofra, TS & COMCEN Sardar Patel
SPIN ON FILTER FOR LUBRICATING OIL 15 W 40 CF4
POLY V BELT
LUB OIL SUMP
FUEL PIPE FEED PUMP TO FILTER)
SPIN ON FUEL FILTER (TWIN BOWL, 0.6 LIT.)
FUEL FILTER ELEMENT PRIMARY
FUEL FILTER SECONDARY ELEMENT
KOEL CARE Super Genuine Oil 13 Liters CAN Part Number :- 82.050.10.0.13
KOEL CARE GENUINE COOLANT PREMIX 5 LITRE CAN Part Number :- 82.020.35.1.05
ASSEMBLY OF AIR CLEANER (AIR CLEANER + STRAP + RAIN CAP) Part no. 4H.412.03.0.PR
PRIMARY AIR CLEANER ELEMENT
FUEL PIPE M14 X M14 B, PARALLEL,750 L , 9.0 I.D.,SAE 100 R6
FAN SPACER (40 MM) RADIATOR
BATTERY CABLE ASSEMBLY 21 SQ.MM Part Number :- 02.950.10.0.00
M & L for FIP Calibration Suitable for Engine of Model 4K1080TA1
M & L for FIP Overhaul Suitable for Engine of Model 4K1080TA1
M & L for Injector Calibration & Pressure Testing Suitable for Engine of Model 4K1080TA1
M & L for Injector Overhaul Suitable for Engine of Model 4K1080TA1
M & L for Starter Servicing Suitable for Engine of Model 4K1080TA1
M & L for Charging Alternater Servicing Suitable for Engine of Model 4K1080TA1
M & L for Radiator Servicing Suitable for Engine of Model 4K1080TA1
Labour for Repair/Servicing /Overhauling to carry out maintenanace of diesel engine driving generating set of capacity 75 KVA (Make - Kirloskar and Mahindra). Checking throughly the Generator and finding out its faulty/defective parts and complete servicing /replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule. : 02 Nos DG sets at Pump House Sardar Patel & Ward room.
SPIN ON FILTER FOR LUBRICATING OIL
FUEL PIPE ( FUEL FILTER TO FUEL PUMP )
FUEL PIPE FEED PUMP TO FILTER)
SPIN ON FUEL FILTER (TWIN BOWL, 0.6 LIT.)
FUEL FILTER ELEMENT PRIMARY
FUEL FILTER SECONDARY ELEMENT
KOEL CARE Super Genuine Oil 13 Liters CAN
KOEL CARE GENUINE COOLANT PREMIX 5 LITRE CAN
PRIMARY AIR CLEANER ELEMENT
FUEL PIPE M14 X M14 B, PARALLEL,750 L , 9.0 I.D.,SAE 100 R6
FUEL PIPE ( RETURN ) M12 X 1.5 MALE PLUG X M14 X 1.5 BANJO ( 700 MM )
BATTERY CABLE ASSEMBLY 21 SQ.MM Part Number :- 02.950.10.0.00
M & L for Injector Calibration & Pressure Testing Suitable for Engine of Make : Kirloskar & Mahindra
M & L for Injector Overhaul Suitable for Engine of Make : Kirloskar & Mahindra
M & L for Starter Servicing Suitable for Engine of Make : Kirloskar & Mahindra
Labour for Repair/Servicing /Overhauling to carry out maintenanace of diesel engine driving generating set of capacity upto 30 KVA (Make - Mahindra) . Checking throughly the Generator and finding out its faulty/defective parts and complete servicing /replacing following spares of the DG set including labour for replacement of defective spares as required to make the DG set 100% functional condition. Testing the DG set after repair to the entire satisfaction of Engr-in-charge. Note:- 1) Spare will be measured separately under relevant item of the schedule - 01 Nos at Navy House Nofra
SPIN ON FILTER FOR LUBRICATING OIL
FUEL PIPE ( FUEL FILTER TO FUEL PUMP )
FUEL PIPE FEED PUMP TO FILTER)
SPIN ON FUEL FILTER (TWIN BOWL, 0.6 LIT.)
FUEL FILTER ELEMENT PRIMARY
FUEL FILTER SECONDARY ELEMENT
Super Genuine Engine Oil 08 Liters CAN
COOLANT PREMIX 5 LITRE CAN
ASSEMBLY OF AIR CLEANER (AIR CLEANER + STRAP + RAIN CAP)
PRIMARY AIR CLEANER ELEMENT
M & L for Injector Overhaul Suitable for Engine of Model 5H.3022/1000462
M & L for Starter Servicing Suitable for Engine of Model 5H.3022/1000462
M & L for Charging Alternater Servicing Suitable for Engine of Model 5H.3022/1000462
M & L for Radiator Servicing Suitable for Engine of Model 5H.3022/1000462
Note for Servicing items of the Schedule ITEM NO 1.00, 2.00 , 3.00 & 4.00 Note:- 1) The above Item Includes following a) Labour Charges tools/gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints related to Genset for a period of one year c) Preventive Maintenanace 4 visit in a year (qtrly based ) to carry out Inspection of 61 Check points of DG sets As per Annexure 'A' attached & submission of Test Report duly signed by Engr-In-Charge, Authorised Kirloskar Care Service Partner & Contractor for every qtrly Visit Note:- 2) The above Item excludes following a) Cost of consumables and spares parts require for preventive or breakdown Visits b) Charges for external job works like FIP-Starter-Charging alternator repairing, AC Alternator Repairing, Machining required for any part of Genset. Note :-3) The Spare Parts, engine Oil & Premix Coolant used for work under contract must be 'Kirloskar Care' genuine / recommended by OEM Purchased from Authorised Kirloskar Care Service/ Mahindra & Spare Dealership.
Note:-4) All works under contract must be carried out by Kirloskar/ Mahindra Trained Service Engineers from Local Autorised Kirloskar Care Service & Spare Dealership to have a quick /urgent hastle free service to restore the system in minimum time frame. Note:-5) The Minor Brakdown Complaints will be attended within 4 Hrs & should be rectified 24 Hrs by Kirloskar Trained Service Engineers from Local Autorised Kirloskar Care Service & Mahindra service Spare Dealership. Note:-6) Contractor has to collabrate with "Kirloskar Bandhan" 1 Year Service Package (4 Visits qtrly based ) from KOEL CARE after acceptance of contract and Mahindra DG service package.
Routine maintenance of fire fighting system including fire pump and Hydrant system complete by attending fault testing of system, Monthly checking of system etc, including replacement of unserviceable component including preventive Maintanence by replacing parts other than mentioned in relevent item of this sch also for fire fighting system installed at Senior Sailor Block ( S1-S7 Building total 07 Nos) serving of each floor of G+6 ie 07 Floors bldgs comprising following: (a) All cable connectors from main control panel to Zonal fire panel. (b) Pumpset Connection checking and 3 phase connection including minor maintainace in connections. (c) Complete oiling/ Greasing in bearing, couplers, fans. (d) Checking of all inlet outlet valves including routine serviceaing of valves and gland packing changing. (e) Making pumpset on and run pumpset for full capacity for at least 15 min. and checking hydrant system at each floor. all Minor maintainace part deemed to be included in rate. The Parts of higher cost measured and paid seperately. Note :All Routine maintenance/testing shall be done through Specialist Fire fighting agency approval of fire fighting agancy from Engr-in-charge is mandatary.
Routine maintenance of fire fighting system including fire pump and Hydrant system complete by attending fault testing of system, Monthly checking of system etc, including replacement of unserviceable component including preventive Maintanence by replacing parts other than mentioned in relevent item of this sch also for fire fighting system installed at Junior Sailor Block ( J1-J5 Building total 05 Nos) serving of each floor of G+8 ie 09 Floors bldgs comprising following: (a) All cable connectors from main control panel to Zonal fire panel. (b) Pumpset Connection checking and 3 phase connection including minor maintainace in connections. (c) Complete oiling/ Greasing in bearing, couplers, fans. (d) Checking of all inlet outlet valves including routine serviceaing of valves and gland packing changing. (e) Making pumpset on and run pumpset for full capacity for at least 15 min. and checking hydrant system at each floor. all Minor maintainace part deemed to be included in rate. The Parts of higher cost measured and paid seperately. Note :All Routine maintenance/testing shall be done through Specialist Fire fighting agency.
Routine maintenance of fire fighting system including fire pump and Hydrant system complete by attending fault testing of system, Monthly checking of system etc, including replacement of unserviceable component including preventive Maintanence by replacing parts other than mentioned in relevent item of this sch also for fire fighting system installed at NOFRA (P-120 to P-122, total 03 Nos Building ) serving of each floor of G+6 bldgs comprising following: (a) All cable connectors from main control panel to Zonal fire panel. (b) Pumpset Connection checking and 3 phase connection including minor maintainace in connections. (c) Complete oiling/ Greasing in bearing, couplers, fans. (d) Checking of all inlet outlet valves including routine serviceaing of valves and gland packing changing. (e) Making pumpset on and run pumpset for full capacity for at least 15 min. and checking hydrant system at each floor. all Minor maintainace part deemed to be included in rate. The Parts of higher cost measured and paid seperately. Note :All Routine maintenance/testing shall be done through Specialist Fire fighting agency.
Routine maintenance of fire fighting system including fire pump and Hydrant system complete by attending fault testing of system, Monthly checking of system etc, including replacement of unserviceable component including preventive Maintanence by replacing parts other than mentioned in relevent item of this sch also for fire fighting system installed at Sardar patel adm office comprising following: (a) All cable connectors from main control panel to Zonal fire panel. (b) Pumpset Connection checking and 3 phse connection including minor maintainace in connections. (c) Complete oiling/ Greasing in bearing, couplers, fans. (d) Checking of all inlet outlet valves including routine serviceaing of valves and gland packing changing. (e) Making pumpset on and run pumpset for full capacity for at least 15 min. and checking hydrant system at each floor. all Minor maintainace part deemed to be included in rate. The Parts of higher cost measured and paid seperately. Note :All Routine maintenance/testing shall be done through Specialist Fire fighting agency.
Routine maintenance and Testing and commissioning “FIRE ALARM CONTROL PANEL” system complete in repairs including wiring and programming in high rise building Senior Sailor Block ( S1-S7 Building total 07 Nos) upto G + 06 stories complete with the following: (a) Complete checking of Manual call point with electronic hooter (one in each floor) (b) Complete checking of Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator for each zone complete. Note: Complete system shall be Tested through specialist Fire fighting agency.
Routine maintenance and Testing and commissioning “FIRE ALARM CONTROL PANEL” system complete in repairs including wiring and programming in high rise building Junior Sailor Block ( J1-J5 Building total 05 Nos) upto G + 08 stories complete with the following: (a) Manual call point with electronic hooter (one in each floor) (b) Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator, Fire Smoke detector for each zone complete. Note: Complete system shall be Tested through specialist Fire fighting agency.
Routine maintenance and Testing and commissioning “FIRE ALARM CONTROL PANEL” system complete in repairs including wiring and programming in high rise building at NOFRA Area (P-120 to P-122, total 03 Nos Building ) upto G + 06 stories complete with the following: (a) Manual call point with electronic hooter (one in each floor) (b) Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator for each zone complete. Note: Complete system shall be Tested through specialist Fire fighting agency.
Servicing of Fire fighting pumpsets including disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out te pump set from base after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gaskets, assembling the pump with replacement of pulley key, gland packing rope, greasing, transporting back to site and fixing on the existing foundation, connecting the electric connection of motor and testing complete to entire satisfaction of Engr-in-charge for the following capacity. (Note :- Major spare parts shall be measured and paid separately, minor spares deemed to in rate quoted, spares like pump shaft, impeller and bearing only will be measured and paid separately under relevant items.
a) Fire pump set of capacity 80 HP
b) Jocky pump set of capacity 15 HP
c) Mono block pump set of 10 HP
Servicing of Fire fighting tarrace pump control panel indoor type 2.00 mm thick CRCA sheet having 40 Amps incoming MCCB and 10 HP starter with MCB TP 32 Amps as outgoing aceesories. including disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out after opening nuts/bolts, transporting from site to workshop, serviceacing transporting back to site and fixing on the existing position connecting the electric connection of motor and testing complete to entire satisfaction of Engr-in-charge for the following capacity. Note :- Major spare parts shall be measured and paid separately, minor spares deemed to in rate quoted, spares like pump shaft, impeller and bearing only will be measured and paid separately under relevant items.
Supply and fix in replacement of manual call point duly painted in red colour paint fitted with front glass (to be broken in case of fire) complete with hammer and test key to check the response with out breaking the glass with LED indicator complete all as specified and directed.
Supply and fix in repair replacement electronic hooters dynamically balanced siren of range 1 KM, 100/440 Volts , RPM 800 to deliver upto 120 DB noise level complete all as specified and as directed by Engineer-in-Charge.
Supply,fixing,in replacement testing & commissioning of combining Smoke Detector & Heat Detector ionization type, automatic reset type approved by loss prevention corporation bureau complete suitable for addressable fire alarm system complete all as specified and directed.
S&F in repair canvas fire hose pipe 63mm dia 30 mtr long instantaneous inlet, made threaded outlet coupling on other end complete all as specified and directed by Engr-in-charge.
Supply and fix in repair canvas fire hose 63 mm dia bore 15 mtr long confirming to IS having male / female brass coupling both ends complete all as specified and directed.
Sypply and fix rubber hose reel of 20 mm size of 30 mtr length complete all as specified and directed at site by Engineer-in-Charge.
Supply and fix in replacement Zone cards suitable for fire alarm system complete all as specified and directed at site by Engineer-in-Charge.
Supply and fix in repair of power card suitable for fire alarm system complete all as specified and directed at site by Engineer-in-Charge.
Repair/replacement of “FIRE ALARM CONTROL PANEL” system complete in repairs including wiring in high rise building upto G + 08 stories complete with the following: (a) Manual call point with electronic hooter (one in each floor) (b) Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator for each zone complete all as specified and directed.
Supply & fix twin out let hydrant with gun metal body having double 65mm dia out let with central valves and instataneous type female coupling with cap on each out let suitable for fixing on 80/100/150 mm flange including taking down the old item complete all as specified and directed by Engineer-in-Charge.
Supply & fix for single out let fire hydrant with gun metal body having 65mm dia out let with valve and instantanious type female coupling with cap on outlet suitable for fixing on 80/100/150mm flange including taking down of the old fire hydrant complete all as specified and directed by Engineer-in-Charge.
Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed by Engineer-in-Charge.
Supply & fix fire hydrant operating GI wheel suitable for operating 65/80 mm dia outlet valve all as specified and directed by Engineer-in-Charge.
Supply & fix brass blank cap and hose lock with 15 cm MS chain suitable for single/double fire hydrant including taking down the old cap & lock complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair steel lock pin (lugs) for 65/80 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair hydrant valve brass spindle complete all as specified and directed by Engineer-in-Charge.
Supply and fix blank MS flange of size 100 mm made out of MS 12 mm thick including flange joint complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair brass nozzle suitable for 20 mm dia rubber hose pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs brass hydrant valve nut as per existing size complete all as specified and directed by Engineer-in-Charge.
Supply and fix PVC blank cap of hydrants with GI chain complete all as specified and directed by Engineer-in-Charge.
Servicing complete to hose reel drum by applying greasing, oiling etc for making free rotation complete and painting two coats of synthetic enamel red paint over a coat of metalic primer complete all as specified and directed.
Servicing complete to twin out let/single out let hydrant by applying greasing, oiling etc for making free rotation complete and painting two coats of synthetic enamel red paint over a coat of metalic primer complete all as specified and directed.
Servicing complete to Sluice valve of size 80/100/150 mm dia (in position) in existing position at site by applying greasing, oiling , packing , Checking threaded rod, etc for making free rotation complete and painting two coats of synthetic enamel black paint over a coat of metalic primer complete all as specified and directed.
Material and labour in replacement of cast iron sluice valve with flanged end class PN 1.6 including all joints with rubber gasket, bolts, and nuts washer complete all as specified of following sizes :-
(a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Supply & fix in replacement of cast iron Strainer for suction heavy duty 150 mm dia with all accessories complete all as specified and directed.
Supply & fix in replacement of cast iron foot valve heavy duty 100 mm dia with all accessories complete all as specified and directed.
Material and Labour for painting of fire hydrant/fire hose box of any size with one coat of red oxide and two coats of synthetic enamelled paint of FIRE RED colour complete with all fittings etc complete all as specified and directed by Engineer-in-charge.
Taking down old GI tubing 80 mm/ 100 mm bore heavy class fixed on wall etc including making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and laying GI tubing 80 mm bore heavy Class complete with fittings like; Tee, bends, flanged etc to be fixed on wall or laid in trenches complete with drilling, welding, bending shaping etc complete all as specified and directed by Engineer-in-Chage.
Supply and laying GI tubing 100 mm bore heavy Class complete with flange type fittings like; Tee, bends, flanged etc to be fixed on wall or laid in trenches complete with drilling, welding, bending shaping etc complete all as specified and directed by Engineer-in-charge.
Material and labour for painting in existing position at site of GI/ MS pipe of size 80/100/150 mm dia, not exceeding 60 cm girth (in position), with one coat of red oxide and two coats of synthetic enamelled paint of FIRE RED colour complete with all fittings etc complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5M in depth for foundation/laying of pipe etc and getting out in hard dense soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil to a distance not exceeding 50 m and depositted where directed complete all as specified.
Material & Labour for PCC 100 mm thick type B1, (1:2:4) using 20 mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
Contactor for starter for 10 HP pumpset tarrece fire fighting fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
Single phase preventor 240 V for starter of 10 HP at fire fighting panel fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
urrent convertor of range 8-20 Amps for starter of 10 HP at fire fighting panel fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
Current transformer of type R, ratio 50/5 , VA 5 , Class-I , ILV 3KV fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
Indicating Lamp (Red,Green,orange or blue) for indicating ON, OFF, TRIP fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
Digital voltmeter for fire fighting pumpset panel fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
Supply and fix digital Ammeter for fire fighting pumpset panel complete all as specified and directed by Engineer-in-Charge.
Srapping and Paining, filling cavities of rusted parts and two coat exposed body surface with synthetic/Oil paint over one coat of red oxide paint 10 HP Pumpsets of any capacity. Colour of pumpset shall be Blue complete all as specified and directed by Engineer-in-Charge.
PVC insulated, heavy duty electric cable with copper /Aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core from fire fighting panel to Pump set fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
PVC insulated PVC sheathed cable galvanized steel strip or wire armored, electronic control cables (Heavy Duty) with stranded Copper conductor of size 2.5 sq mm 4 core 1100 Volts grade fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
Change over switch of capacity 400 Amps manually operated for 250 KVA DG Set with enclosure SS of 1.6 Guage thickness fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
CI Non return valve of 100 mm size fixed in repair / replacement complete all as specified and directed by Engineer-in-Charge.
RAJ ENTERPRISE
shree chamunda enterprise
SHREEJI ENTERPRISE
M/S Rajendra Constructions
RUDRAAY CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .