| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAdmitted-Finance | ₹3.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.8 Cr+₹62,755.39 (0.16%)Admitted-Finance BANKERS VILLA VAZHOTTUKONAM VATTIYOORKKAVU P O TRIVANDRUM 695 013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | ₹3.8 Cr+₹62,755.39 (0.16%) | L2 | Admitted-Finance |
| 3 | L3₹3.8 Cr+₹1.3 L (0.33%)Admitted-Finance | ₹3.8 Cr+₹1.3 L (0.33%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Peter And Company L3 | Bankers Construction L2 | CUBIX INFRASTRUCTURES L1 |
|---|---|---|---|---|---|---|
| 1.00CIVIL WORKS | ||||||
| 1.00 | 15.7.4 Demolishing brick work manually / by mechanical means including stacking of
serviceable material and disposal of unserviceable material within 50 metres lead as
per direction of Engineer-in-Charge.In cement mortar | 77.53 | cum | 2,122.19 ₹1,64,533.39 | 2,121.19 ₹1,64,455.86 | 2,120.19 ₹1,64,378.33 Lowest |
| 1.00 | 15.3 Demolishing R.C.C. work manually / by mechanical means including stacking of
steel bars and disposal of unserviceable material with in 50 metres lead as per
direction of Engineer -in-Charge. | 2.49 | cum | 3,656.53 ₹9,112.07 | 3,655.53 ₹9,109.58 | 3,654.53 ₹9,107.09 Lowest |
| 1.00 | 15.12.1 Dismantling doors, windows and clerestory windows (steel or wood ) shutter
including chowkhats, architrave, holdfasts etc. complete and stacking within 50
metres lead:Of area 3 sq. metres and below | 51 | each | 380.66 ₹19,413.66 | 379.66 ₹19,362.66 | 378.66 ₹19,311.66 Lowest |
| 1.00 | 15.57 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false
ceiling including disposal of unserviceable material and stacking of serviceable
material with in 50 metres lead as directed by Engineer - in-Charge | 18.26 | sqm | 61.05 ₹1,114.77 | 60.05 ₹1,096.51 | 59.05 ₹1,078.25 Lowest |
| 1.00 | 15.2.2 Demolishing cement concrete manually / by mechanical means including disposal of
material within 50 metres lead as per direction of Engineer - in-Charge.Nominal
concrete 1:4:8 or leaner mix ( including equivalent design mix) | 11.47 | cum | 1,549.66 ₹17,782.35 | 1,548.66 ₹17,770.87 | 1,547.66 ₹17,759.4 Lowest |
| 1.01 | 14.4.1 Making the opening in brick masonry including dismantling in floor or wallsFor door
/ window / clerestory window | 17.08 | sqm | 1,309.33 ₹22,363.36 | 1,308.33 ₹22,346.28 | 1,307.33 ₹22,329.2 Lowest |
| 1.01 | 15.17.2 Dismantling steel work in single sections including dismembering and stacking
within 50 metes lead in:Channels, angles, tees and flats | 6,012.4 | kg | 4.36 ₹26,214.06 | 3.36 ₹20,201.66 | 2.36 ₹14,189.26 Lowest |
| 1.01 | 15.28.2 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the
material within 50 metres lead of :Asbestos cement Sheet | 249.2 | sqm | 82.57 ₹20,576.11 | 81.57 ₹20,326.92 | 80.57 ₹20,077.72 Lowest |
| 1.01 | 15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking
material within 50 metres lead.For thickness of tiles 10 mm to 25 mm | 481.33 | sqm | 78.49 ₹37,779.91 | 77.49 ₹37,298.57 | 76.49 ₹36,817.24 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
3 Feb 2026, 4:00 pmClosed
ENGINEER (PROJECTS)
KEL MAMALA KOCHI
GENERAL-Department of Tourism-Renovation of Palakkad Guest House, Palakkad District General Civil Work
2026_KEL_830885_1
KRO/BDC/2289/2026
Open Tender
Civil Works - Buildings
Item Rate
KEL MAMALA KOCHI
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,850
₹1 L
Yes
5 Feb 2026
27 Jan 2026
4 Feb 2026
27 Jan 2026
3 Feb 2026
27 Jan 2026
27 Jan 2026 - 3 Feb 2026
CIVIL WORKS
15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.3 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.12.1 Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
15.57 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
15.2.2 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix)
14.4.1 Making the opening in brick masonry including dismantling in floor or wallsFor door / window / clerestory window
15.17.2 Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:Channels, angles, tees and flats
15.28.2 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet
15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
OD280922/2025-2026 Dismantling of sanitary fittings such as Water closet, wash basin,Heater etc. complete as per the direction of the Engineer-in-charge.
OD280926/2025-2026 Dismantling of bathroom fittings such as Health faucet,bibcock,Towel rod,shower etc. complete as per the direction of the Engineer-in-charge.
OD280929/2025-2026 Dismantling of existing pvc pipes and fittings up to 110mm dia. complete as per the direction of the Engineer-in-charge
OD281054/2025-2026 Taking out and removing all loose filling materials like brick bats, broken tiles, brick pieces, sand, aggregates etc. from sunken floor/toilet area disposing of all debris within 50 m lead, complete as directed by EngineerinCharge. complete as per the direction of the Engineer-in-charge
14.1.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
13.88 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
26.30.1 Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.Upto and including 12mm dia.
OD281055/2025-2026 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge.
OD281056/2025-2026 Hiring for general labour for carrying out extra work and patch works etc complete as per the direction of engineer in charge
OD281057/2025-2026 Providing labour for cement plaster work in patches,jambs,soffits and edges around door, windows etc complete as per the direction of engineer in charge
OD281058/2025-2026 Hiring for Carpenter for repair of existing wooden door shutter work etc complete as per the direction of engineer in charge
OD281059/2025-2026 Dismantling existing wall / ceiling panelling (wooden / Gypsum / PVC / metal / composite, etc.) including framing members, fasteners and backing boards, c disposing unserviceable materials within 50 m lead, complete as directed by Engineer?in?Charge.
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
OD281060/2025-2026 Providing and filling M sand in sunken portion of toilets including carriage, labour etc complete
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum
5.33.2.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
50.6.2.1 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
6.47 Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 150mm/230mm/300 mm thick with Grade- I AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
9.147D.4 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
9.147D.3 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm)
9.147A.1 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)
21.8.1 Filling the gap in between aluminium frame & adjacent RCC/ Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawing and direction of Engineer-in -Charge complete.Upto 5 mm depth and 5 mm width
21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
11.49.3 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 800x800 mm
11.48.3 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 800x800mm
8.3.2 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
OD281061/2025-2026 " Providing and laying 50 mm thick, natural stones of size 60x30 cm laid in required colour and pattern over and including 50 mm thick compacted bed of 5 mm thick 6mm aggregates, filling the joints with cement concrete 1.2.4 etc. all complete as per the direction of Engineer in-charge"
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.52.1Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
14.72 Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
OD281073/2025-2026 "Providing and laying approved damp proofing compound as per manufacturer?s .Finished surface should be smooth and even, as per direction of Engineer-in-Charge. Providing and laying High performance two component elastomeric cementitious damp-proof coating., by applying in 2 coats to achieve 1mm thickness. The 1st coat should be allowed to dry for 4-6 hours @ 27oC before applying the 2nd coat.The coated surface should be air cured for a period of 4-5 days."
22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
OD281112/2025-2026 Handrail (Stair area) - Using 12mm toughened glass(Saint gobain) and 38mm round knob( Black PVD finish) and Wooden top rail (Teak wood) 55X55mm . Including installation and polish work etc. as per approval of Engineer-in-charge,
9.81.1 Providing and fixing bright finished brass handles with screws etc. complete:125 mm
OD281117/2025-2026 Providing and fixing dorset dead lock 21mm nickel wit doorset cylinder lock BSK 60mm of approved quality with necessary screw etc.complete
9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
9.82 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
9.74.1 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm
12.45.3 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
OD281185/2025-2026 Providing and fixing factory made single extruded Wood Polymer Composite (WPC) solid plain white color or colored panels of approved make and brand, c, securely fixed with stainless steel screws and accessories, all as per the directions of the Engineer-in-charge. The thickness of panels shall be 6 mm to 12mm and measured in square meters.
OD281203/2025-2026 Providing and fixing factory made Wood Polymer Composite (WPC) cornices of approved make and brand
OD281214/2025-2026 Supply and fixing terracotta jalli with type-3 adhesive including labour as per architectural drawing etc complete
8.32 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
25.1 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminum extruded section shall be taken for purpose of payment
25.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to ? 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr? 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.? 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml? 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm? 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test? Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml?
OD282447/2025-2026 Providing and fixing pre hung doors with hardwood/UPVC/WPC frame and solid core flush doors of decorative laminate finish on both faces of shutters with edge lipping
9.121 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
9.122.1 Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames
9.77 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete
8.5 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
OD281217/2025-2026 Providing and fixing 18mm thick ferro cement slab for kitchen platforms,vanity counters,windows sills,of required size etc.complete all levels
OD281225/2025-2026 Providing and fixing curtain for window of required size etc.with neccessories and screw,Stitching & Fitting Chargesetc. Complete
21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)
OD281233/2025-2026 Providing and fixing Main Door Handle 22mm x 150mm of approved quality with necessary screws etc.complete
10.16.2 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
OD281250/2025-2026 Providing and fixing precoated PUF sandwich roofing panels 50 mm thick, density 40 kg/m³, with 0.5 mm top and 0.4 mm bottom CR sheet coating, including corner flashings, ridges, and fixtures complete as per specification
12.26.1 Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).6 mm thick cement fiber board as per IS: 14862
OD281291/2025-2026 Supply and installation of Mirror of superior make glass 61x195 cm,19mm mirror cap and holes as per Engineer in charge.
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
9.7.4.1 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Ply wood 7 ply, 9 mm thickDecorative plywood one side decorative veneer and commercial veneer on other face (Type I) conforming to IS 1328 BWR Type
OD281333/2025-2026 Supplying and fixing neccessary writings and emplems with LED lighting,using ACP material cost and conveyance and fixing charge etc as per the direction from the engineer in charge.
OD281393/2025-2026 Making circular holes by core cutting method in Reinforced Cement Concrete (RCC) slab, beam, or wall of specified diameter as per drawing and instructions of Engineerin-Charge, including furnishing and fixing of templates for accuracy, use of approved mechanical core cutting machine, cleaning of core cutting surface and removal of excess debris from site. The concrete should be adequately cured and attained sufficient strength before core cutting
Water Supply and Sanitary Works
OD281404/2025-2026 Providing and fixing wall hung toilet with quiet clore UF-Seat in white type water closet (K757081N-SS-O/K757081N-2SS-O). flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.
OD281419/2025-2026 "Supplying and fixing ELATE-97258IN-CP_KOHLER_HEALTH FAUCET Description-ELATEHealthFaucet WithHose &Bracke complete as per the direction of site Engineer-in-charge."
OD281420/2025-2026 "Providing and fixing RAIN MAX-26856IN-CP_KOHLER_OVERHEAD SHOWER,Description-RAINMAXSquare305mm single-functionrainhead,22lpm
OD281421/2025-2026 "Providing and fixing ALEO+-72337IN-4ND-CP_KOHLER_BASIN MIX Description-ALEO+Singlecontrol tall basin faucet without drain in polished chrome"
OD281424/2025-2026 "Providing and fixing AUTOSENSE 235+-20740IN-A-NA_KOHLER_THERMOST ATICVALVE Description-AUTOSENSE235+Thermostatic recessedbathandshower2-wayva
OD281426/2025-2026 "Providing and fixing AUTOSENSE 235+-20742IN-9FP-CP_KOHLER_SHOWER MIXER Description-AUTOSENSE235+Geometric thermostaticrecessedbathandshowersquare triminpolishedchrome
OD281439/2025-2026 "Providing and fixingVIVE-32485IN-NA_KOHLER_WASTE COUPLING Description-VIVEWasteCouplingwithout overflowholeforSinkDrain"
OD281440/2025-2026 "Providing and fixing EVO FIT+-33931IN-M-0_KOHLER_CONCEALED CISTERN Description-In-wall tankwithframe"
OD281441/2025-2026 "Providing and fixing COMPLEMENTARY-16089IN-NA_KOHLER _STOPCOCK Description-COMPLEMENTARYIn-linestop valveG3/
OD281442/2025-2026 "Providing and fixing 1355356_KOHLER_CONNECTOR Description-DrainconnectorassyOW including waste coupling"
OD281443/2025-2026 "Providing and fixing NOTE-75891IN-M-CP_KOHLER_CONTROL PLATE Description-FacePlateForInwallTank"
OD281444/2025-2026 "Providing and fixing 75423IN-CP_KOHLER_FLOORDRAINER Description-ColourFinish:Chrome Large-volumeHiddenFloorDrai
OD281445/2025-2026 "Providing and fixing COMPLEMENTARY-25074IN-CP_KOHLER _TUMBLERHOLDER Description-COMPLEMENTARYSquare tumblerholder inpolishedchrome"
OD281446/2025-2026 " Supplying and fixing COMPLEMENTARY-5636IN-CP_KOHLER_ GLASS SHELF Description-COMPLEMENTARY Glass shelf in polished chrome
OD281456/2025-2026 "Providing and fixing wash basin with VIVE-28783IN-0_KOHLER_COUNTER BASIN including bottletrap Description-547mmovalvesselbathroom sink,nooverflow
OD281458/2025-2026 "roviding and fixing 1355356_KOHLER_CONNECTOR Description-DrainconnectorassyOW including waste coupling"
OD281463/2025-2026 "Providing and fixing JULY-80154IN-4-CP_KOHLER_ANGLE COCK Description-AnglevalveG13mminpolished chrome "
OD281486/2025-2026 "Providing and fixing floor trap 75422IN-CP_KOHLER_FLOORDRAINER Description-ColourFinish:Chrome Hidden Floor Drain-Square inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer-in-Charge at all levels"
OD281487/2025-2026 "Supplying and fixing COMPLEMENTARY-5634IN-CP_KOHLER_ SOAPDISH Description-COMPLEMENTARYSoapdishin polishedchrome including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge."
OD281490/2025-2026 Supplying and fixing COMPLEMENTARY-25066IN-CP_KOHLER _TOWELSHELF Description-COMPLEMENTARYTowel shelf in polished chrome including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
OD281495/2025-2026 "Supplying and fixing CRUZ-10712D-CP_KOHLER_SOAP DISPENSER Description-CRUZSoapdispenserandholder withfrostedglassbottleinpolishedchrome including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge."
OD281499/2025-2026 "Supplying and fixing COMPLEMENTARY-25065IN-CP_KOHLER _TOWEL ROD Description-COMPLEMENTARYSquare 610mmsingletowelbar inpolishedchrome including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge."
OD281504/2025-2026 "Supplying and fixing 33979IN-4-CPINLINESTOPVALVETRIM APT_KOHLER_STOPCOCK Description-APTSTOPVALVETRIMIN POLISHEDCHROME including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge."
OD281505/2025-2026 " Supplying and fixing COMPLEMENTARY-75823IN-CP_KOHLER _BOTTLETRAP Description-COMPLEMENTARYBottleTrap 350mm including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge."
18.49.1 Providing and fixing C.P brass bib cock of approved quality conforming to IS: 8931.15 mm nominal bore
18.21.2.1 Providing and fixing uplasticised PVC connection pipe with brass unions: 45 cm length15 mm nominal bore
17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
17.7.2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
18.50.1 Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
50.17.1.1 Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge
50.17.1.3 Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-incharge.
50.17.1.4 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
17.28.2.1 Flexible pipe32 mm dia
18.8.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal dia pipes
18.8.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes
18.8.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes
18.8.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal dia pipes
18.9.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal dia pipes
18.9.5 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal dia pipes
50.18.8.8.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
50.18.8.9.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.8.8.2 Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2
50.18.9.9.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
50.18.9.7.1 Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
50.18.9.6.2 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2
50.18.9.17.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.16.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
50.18.9.18.1 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall
50.18.9.19.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
18.18.2 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore
18.19.4.2 Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreVertical
50.18.9.20.7 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl
50.18.9.21 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
50.18.9.21.3 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow
50.18.9.22.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.3 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
18.19.5.2 Providing and fixing gun metal non-return valve of approved quality (screwed end): 65 mm nominal boreVertical
18.18.3 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore
19.7.1.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
18.77 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof
Electrical Works
1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.55.2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
OD281515/2025-2026 Supplying and fixing extra conduit down rod of 75 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required.
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.24.8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
90.10.3.15 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.1.2 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.1.3 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.5 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.28.1 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD281517/2025-2026 OD: Supplying, fabricating, painting, fixing and commissioning of 2-pole metal distribution enclosure suitable for housing 2-pole MCCBs/Isolators/MCBs for Incoming/outgoing circuits. Suitable for indoor/outdoor installation.
90.14.28.1 S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.4.2 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way (4+18), Double door
2.4.3 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way(4+24), Double door
2.5.2 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 Way(4+24), Double door
90.11.1.19 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.14.10.3 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.10.3 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD281520/2025-2026 Supplying and fixing 40 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD281521/2025-2026 Supplying and fixing 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.14.3 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
OD281523/2025-2026 OD: Supply and installation of earth bunch having 12 nos of poles with cu bounded etc with complete as required.
5.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
90.12.7.30 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.7.43 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
90.12.7.42 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
90.12.7.40 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.6.6.3 Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
9.1.23 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.35 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
OD281528/2025-2026 OD: Supplying, conveying, fixing, testing and commissioning of LED strip light, 12V/24V DC, flexible type, minimum 14?18 W per metre, delivering minimum 1000 lumen per metre, with high-brightness SMD LEDs (minimum 120 LEDs per metre), colour temperature 3000K/4000K/6000K as required, CRI > 80, complete with suitable LED driver (SMPS type), aluminium channel profile with opal diffuser, end caps, clamps, connectors, fixing accessories, including cutting, soldering, mounting, concealed/ surface wiring with suitable size copper flexible wire, making good the damages to surface, testing and commissioning etc. complete as required at site.
OD281536/2025-2026 Supplying and fixing surface mounting 20W LED batten fitting (integrated type) with aluminium/plastic body, opal diffuser suitable for use on 230–250 V AC supply, including necessary hardware and electrical connections using copper flexible wire, complete as required.
OD281566/2025-2026 Supplying and fixing recessed mounted LED downlight/ceiling light fitting of 6Wcapacity, cool white (5700K), minimum system efficacy of 100 lumens/Watt, CRI 80, PF 0.90, THD < 10%,with BIS-certified inbuilt driver, suitable for operation on 140–270V AC, including necessary wiring, connections, and fixing on false/surface ceiling using approved materials as required, complete as per the direction of site engineer-in-charge.
OD281568/2025-2026 Supplying and fixing recessed mounted LED downlight/ceiling light fitting of 12Wcapacity, cool white (5700K), minimum system efficacy of 100 lumens/Watt, CRI 80, PF 0.90, THD < 10%,with BIS-certified inbuilt driver, suitable for operation on 140–270V AC, including necessary wiring, connections, and fixing on false/surface ceiling using approved materials as required, complete as per the direction of site engineer-in-charge.
OD281627/2025-2026 OD: Supply, conveyance, installation, testing and commissioning of Surface mounted LED bulkhead having efficacy not less than 66 lumen/watt and power consumption of not less than 9W with high pressure die cast aluminium polycarbonate diffuser with all accessories as required. with IP 65 protection.
OD281632/2025-2026 Supply, installation, testing, and commissioning of wall-mounted LED bed head lights, each of 7W power rating, delivering a minimum of 500 lumens with a warm white color temperature (2700K–3000K), suitable for reading and ambient lighting. The LED lights shall operate at 220V AC ±10%, 50Hz, have a power factor 0.9, CRI 80, and be compliant with IS 10322 (Part 5/Sec 11), BIS, CE, and RoHS standards
OD281637/2025-2026 Supply of Mirror Light, high efficiency with a nominal system lumen output of 760 lumens. Luminaire wattage should not exceed 9W. The luminaire should have a CRI > 80. Driver of the luminaire shall have THD < 10% and PF > 0.9. Slim LED batten in aluminium housing and decorative end caps. Robust driver with wide voltage range 100-240 volts and inbuilt protection. Aesthetically designed mirror LED light fixture of 4000 K, of surface mounting which provides soft-light and glare free symmetrical illumination.
OD281701/2025-2026 Supply, installation, testing and commissioning of decorative chandelier type LED light fitting of suitable design and size, having a total power rating of 40 W to 60 W (as per room size and illumination requirement), operating on 230 V AC, 50 Hz single phase supply, complete with decorative glass or acrylic shade, metal body, suspension chain/rod, integrated electronic driver, all necessary accessories, connection materials, and fixing arrangements as per the direction of the Engineer-inCharge.
OD281759/2025-2026 OD: Supplying, installing, testing and commissioning of 1200 mm sweep Premium BLDC ceiling fan, ultra-silent operation, with designer aerodynamic blades, metallic premium finish, integrated modern aesthetic motor housing, 5-star energy rated BLDC motor, high air delivery not less than 210 CMM, service value minimum 6.0, RPM approx. 350 (as per IS 374:2019), THD < 10%, PF 0.90, with remotecontrolled smooth speed regulation, sleep mode, timer function, complete with 30 cm decorated downrod, twin canopies, shackle kit, safety rope, copper winding, required fixing accessories, earthing, testing and commissioning, including making good the damages, etc. complete as required.
OD281814/2025-2026 OD: Supplying, conveying, installation, testing and commissioning of 400 mm exhaust fan, heavy-duty type, with metallic blades, metallic front and rear safety guards, powder-coated metallic body, suitable wall mounting bracket with oscillation mechanism, operating on 230V, 50 Hz, single phase AC supply,3-speed control, including connection with suitable size copper flexible wire, required mounting hardware, making good the damages, colour washing etc. complete as required at site
OD281893/2025-2026 Supply, installation, testing and commissioning of 15 litre capacity storage type electric water heater (geyser) suitable for wall mounting, with ISI-marked 2 kW heating element, thermostat control, thermal cut-out, pressure and safety valve, indicator lamps, inlet and outlet connections, and all necessary accessories, complete with electrical connections using suitable size copper conductor cable, etc as required and as directed by the Engineer-in-Charge.
OD281924/2025-2026 "OD: Supply installation testing and commissioning of Air conditioner of the following specification and complete the work as required Air Conditioner- : 1.5 Ton, Inverter type 1. Star rating : 5 Star 2. Ton : 1.5 3. Technology : Split Air conditioner 4. Condenser coil & pipe : Copper 5. Refrigerant : R410A/R32 6. Compressor Type : High EER Rotary 7. Control : Microprocessor controlled codeless lcd remote 8. Power Source (V/Hz/Ø) : 230/50/1 9. Warranty : As per government orders 10. Make : Bluestar/Voltas/Lloyd/Mitsubuzhi Voltage Stabilizer ? 1 No 1. Voltage Stabilizer Wall mount type with Time delay,High& low voltage& Thermal overload Protection. 2.Capacity :Suitable size for 1.5 ton 3.Warranty :1 years 4. Input voltage : 300 V 5. OutputVoltage : 200-240 V 6. High Voltage Cut Off: 240 7. Efficiency : >95% 8. Frequency : 50Hz 9.Make : V guard or Equivalent. 10. 3 Pin top :1 Nos Equipment shall be supplied along with : 1. 3 mtr copper piping with superlon insulation for suction line 2. 3 mtr copper piping with superlon insulation for Discharge line 3. 3mtr PVC piping for drain "
OD281931/2025-2026 "OD: Supply installation testing and commissioning of Air conditioner of the following specification and complete the work as required Air Conditioner- : 2 Ton, Inverter type 1. Star rating : 5 Star 2. Ton : 2 3. Technology : Split Air conditioner 4. Condenser coil & pipe : Copper 5. Refrigerant : R410A/R32 6. Compressor Type : High EER Rotary 7. Control : Microprocessor controlled codeless lcd remote 8. Power Source (V/Hz/Ø) : 230/50/1 9. Warranty : As per government orders 10. Make : Bluestar/Voltas/Lloyd/Mitsubuzhi Voltage Stabilizer – 1 No 1. Voltage Stabilizer Wall mount type with Time delay,High& low voltage& Thermal overload Protection. 2.Capacity :Suitable size for 2 ton 3.Warranty :1 years 4. Input voltage : 500 V 5. OutputVoltage : 200-240 V 6. High Voltage Cut Off: 240 7. Efficiency : >95% 8. Frequency : 50Hz 9.Make : V guard or Equivalent. 10. 3 Pin top :1 Nos Equipment shall be supplied along with : 1. 3 mtr copper piping with superlon insulation for suction line 2. 3 mtr copper piping with superlon insulation for Discharge line 3. 3mtr PVC piping for drain "
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD282007/2025-2026 OD: Supply & Providing 9 W LED Bulb with B22 base, working on 230 V AC supply
OD282016/2025-2026 Supply, installation testing & commissioning of 250 mm sweep Light Duty Exhaust fan in non metal frame working on 230 V A/C complete the work as required
90.15.4.6 Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.3 Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD282031/2025-2026 "Fabrication and supply of 62.5kva DG set supported AMF panel cubicle type dust and vermin proof, Wall mounted front operated panel as per given specification and electrical inspectorate standard, made out of 16 SWG CRCA sheet with IP 54 protection, fully compartmentalized doors with concealed hinges, Rubber beedings, earthed doors, The board shall be provided with earth bus for the full length, Entire sheet work will be treated under seven tank processes and then powder coated with siemens gray mat finish. 125A 4P Contactor -2NOS,125A MCCB -2NOS,AMF Relay-C&S-1NOS,MFM ,Emergency PB, Start Stop Push Button, Contactor On Off Push Button ,Multi Function Relay ,Volte Meter, RYB Indications- 2set,Sigle Phase Preventer.Etc) "
OD282064/2025-2026 "OUTDOOR METERING CUBICLE:-Supply, fabrication, erection, testing and commissioning of cubicle type fullycompartmentalised, dust tight, vermin proof, water proof Metering Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as perstandards with double earth,Glass windows connection to all switches, internal rigid connection etc. including suitable chambers, front open, with water proof shrouding pane (All switches shall confirm to conforming to IEC 60947-2 standards) Incomer - 160 A TPN Isolator Metering Provisions- Provisions suiting to 3 Phase Metering, kwh class I Digital type Energy Meter-1 Nos. ELR with CBCT and control MCB-1 Nos "
90.12.9.6 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench110/94 mm or nearest size
OD282063/2025-2026 Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
OD282066/2025-2026 Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
OD282614/2025-2026 Preparation of design and drawings showing site plan, schematic diagram etc, as per the requirements of Electrical Inspectorate and getting approval from Electrical Inspectorate for the scheme. Submission of completion report, arranging Inpsection and obtaining Sanction Order from Electrical Inspectorate.(*All Statutory fees should be remitted by the Consumer/Client or it should be reimbursed on the submission of supporting documents).
OD282620/2025-2026 Co-ordination with KSEB in getting supply from kseb. It will include charge for extra OH ABC line, electric osts etc for getting the electric supply.(*All Statutory fees should be remitted by the Consumer/Client or it should be reimbursed on the submission of supporting documents).
CCTV AND ITS ALLIED WORKS
OD282927/2025-2026 Supply,Installation,testing and commissioning of NVR Up to 32 channel IP camera input Instastream, H.265, H.264 , H.264, MJPEG Decoding Max. decoding capability: 8 × 1080p@30 fps or 2 × 8 MP@30 fps Max. 160/128/60 Mbps Incoming/ Recording/ Outgoing Bandwidth Support 2 SATA HDDs up to 20TB Each, 2 USB Ports HDMI / VGA simultaneous video output AI by Camera: Face detection and recognition, Perimeter protection, SMD Plus, People counting, Stereo analysis and heat map Support Multi-brand network cameras
OD282932/2025-2026 Supply,Installation,testing and commissioning of NVR Up to 8 Channel IP Camera input instastream, H.265, H.264, MJPEG Up to 12 MP resolution preview and playback AI disabled: 160 Mbps incoming, AI enabled: 80 Mbps incoming Support 2 SATA HDDs up to 20TB each, 2 USB ports(2.0) HDMI / VGA simultaneous video output
OD282944/2025-2026 Supply,Installation,testing and commiddioning of 4MP Network IR Dome Camera - 30Mtr. 1/2.9” 4MP PS CMOS Image Sensor (0.8758 centimeters) Max. 4MP (2688 × 1520)@1-25/30fps/ (2560 × 1440)@1-25/30 Instastream, H.265, H.264, H.264H, H.264B, MJPEG Support Triple stream WDR (120dB), Day/Night(ICR), 3D NR, AWB, AGC, BLC, HLC, Digital watermarking 3.6mm fixed Lens IR Range of 30 Mtr., IP67, PoE
OD282950/2025-2026 Supply and installation of 8 TB Surveillance HDD Form factor : 3.5-inch Interface SATA 6 Gbit/s Number of cameras supported : 64, RoHS compatible : Yes, Halogen Free : Yes, Rotational speed : 7200 rpm, Buffer size 512 MB, 24/7 operation : Yes for video recording inside the existing NVR. The drive should have 24X7 reliabilty, Reduced power consumption, Compatible, Advanced format technology(AF), Long Term reliability etc.
OD282962/2025-2026 Supply and Drawing HDMI Cable for connecting the output from NVR to the LED TVs
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
OD282966/2025-2026 Supply, installation, testing and commissioning of 1 kVA online UPS using INBUILT SMF batterY, providing stabilized sine wave output with inbuilt protection for overload, short-circuit, and surge, complete with all accessories and connections as per IS 16242 and IEC 62040 standards and the direction of the Engineer-inCharge.
DISMANTLING
OD284853/2025-2026 Dismantling of 1.5-ton split type air conditioner, including indoor unit, outdoor unit, interconnecting refrigerant copper piping, drain pipe, electrical control wiring, conduit, mounting brackets, and all associated accessories, by safely recovering refrigerant gas into the system (where possible), disconnecting power supply, removing bolts, supports, clamps, making the wall good after removing pipes and brackets, clearing debris, and stacking all dismantled materials at the site as directed by the Engineer-in-Charge, complete.
OD284870/2025-2026 Dismantling and removing the existing electrical fittings such as LED/tube light fittings, ceiling/wall light fittings, CFL/fluorescent fittings, bulkhead fittings, fan regulators, plug points, sockets, switches, switchboards, plates, and associated accessories, including disconnection from the electrical supply, removing screws, clamps, hardware etc., lowering carefully without damage, segregating reusable and non-reusable items, stacking the serviceable materials at site as directed, disposing unserviceable items to a place approved by the Engineer-in-Charge, and making good the damages to walls/ceilings, colour washing/patching where required, complete.
EXCLUSIVE OF GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
9. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
10.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
11. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
12.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
13. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
14.VITRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
15.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
BOQ_1396001.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .