Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹21.3 L+₹6.4 L (43.5%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance Being not L1 | |
| 3 | Rejected-Technical 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | - | Rejected-Technical Not enlisted in appropriate category i.e a (ii) |
Tender Value
₹26.3 L
EMD Value
₹52,540
Closing Date
10 May 2024, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIR, MAINTENANCE OF ARBORICULTURE PIPE LINES, SAFETY RELATED WORKS, REPLACEMENT OF UNSV SAFETY DISPLAY BOARDS, DISTRIBUTION DIAGRAMS, RATING PLATES, FIRE FIGHTING ITEMS AND ALLIED WORKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE(I) DM VISAKHAPATNAM
2024_MES_649960_1
8017/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹52,540
Yes
6 Jul 2024
12 Apr 2024
13 May 2024
12 Apr 2024
10 May 2024
26 Apr 2024
Amount
Dismantling taking out GI pipe 25mm bore from PCC support/trenches for repair/ replacement/ relaying complete all as specified and directed.
Supply, fixing and testing of 25 mm bore medium grade including complete GI specials on PCC support or on trenches complete all as specified and directed.
Laying only GI pipe 25mm bore obtained from item No. 1.00 above, after proper cleaning, descalling and fixing to original position including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
Dismantling taking out GI pipe 40mm bore from PCC support/trenches for repair/ replacement/ relaying complete all as specified and directed.
Supply, fixing and testing of 40 mm bore medium grade GI pipe including complete GI specials on PCC support or on trenches complete all as specified and directed.
Laying only GI pipe 40mm bore obtained from item No. 4.00 above, after proper cleaning, descalling and fixing to original position including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
Dismantling taking out GI pipe 50mm bore from PCC support/trenches for repair/ replacement/ relaying complete all as specified and directed.
Supply, fixing and testing of 50 mm bore medium grade including complete GI specials on PCC support or on trenches complete all as specified and directed.
Laying only GI pipe 50mm bore obtained from item No. 7.00 above, after proper cleaning, descalling and fixing to original position including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
Excavation in trenches not exceeding 1.5M in depth and not exceeding 1.5M wide for pipe and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5M in depth and not exceeding 1.5M wide for cable/pipe and getting out in hard rock/Road/PCC hard standing and making the disturbed surfaces good same as existing before excavation complete all as specified and directed.
Returning, filling in(soil), including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated materials(soil) not exceeding 50M, depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
Labour only for attending break down of pipe line bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes etc as per site requirement, testing for leakages of testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed for the bore of GI pipe upto 25mm. Note:- (i)The quoted rate is deemed to be include the following:- (a) Arrangement of suitable pump sets for dewatering at the time of breakdown. (b) Necessary labour/trade men for attending break down . (c) labour element required for fixing CI/DI/MS pipes, specials fittings (ii) CI/DI/MS Pipes and specials will be measured and paid seperately under relevant items.Items which are not available as supply only are deemed to be included to make the unit completely functional
Labour only for attending break down of pipe line bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes etc as per site requirement, testing for leakages of testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed for the bore of GI pipe upto 40/50mm. Note :- (i) The quoted rate is deemed to be include the following:- (a) arrangement of suitable pump sets for dewatering at the time of breakdown. (b) Necessary labour/trade men for attending break down . (c) labour element required for fixing CI/DI/MS pipes, specials fittings. (ii) CI/DI/MS Pipes and specials will be measured and paid seperately under relevant items.Items which are not available as supply only are deemed to be included to make the unit completely functional
Supply only Gun metal gate valve of size 50mm dia including taking out old unserviceable one complete all as specified and directed.
Supply only Gun metal gate valve of size 40mm dia including taking out old unserviceable one complete all as specified and directed.
Supply only Ball valve of size 25mm including taking out old unserviceable one complete all as specified and directed.
Surface dressing of areas of above pipelines by clearing away all grass, wild vegetation, saplings, shrubs, brushwood, undergrowth, roots and tress not exceeding 30cm girth and removing rubbish upto a distance of 50M outside the periphery of the area under clearance complete all as specified and as directed.
M&L preparation of valve chambers smooth as existing and applying three coats white wash and applying synthetic enamel black paint after cleaning debris and vegetation etc per month complete all as specified and directed by Engr-in-Charge
Supply and fix acryllic LED name board as designed with radium glow lettering along with frame,base and structure support and internally wired for lighting waterproof for fixing at outdoor including plug in the remotereceiver and power adaptor and as per site complete all as specified and directed. Note:- The letters/design to be displayed will be approved by engineer in charge and prior approval to be taken.
Supply and fix distribution diagrams of water supply along with frame,base and structure support and as per site complete all as specified and directed. Note:- The letters/design to be displayed will be approved by engineer in charge and prior approval to be taken
M&L for dismatling of foundation PCC, taking out from pump house, carrying to dumping yard inside ND (V) and necessary cleaning of work site all as specified and directed.
M&L for cement concrete type B1, (1:2:4) with 20mm graded agreegate in foundation, filling in and mass concrete all as specified and directed.
GVR CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .