| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.3 L+₹54,664 (3.47%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹17.2 L+₹1.5 L (9.30%)Rejected-Finance 20F MOTOLAL BASAK LANE KANKURGACHI KOLKATA 700054 | KOLKATA | KOLKATA | WEST BENGAL | 700054 | L3 | Rejected-Finance L3 | |
| 4 | L4₹17.7 L+₹1.9 L (12.0%)Rejected-Finance DL 221 3 SALT LAKE SECTOR II KOLKATA 700091 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L4 | Rejected-Finance L4 | |
| 5 | L5₹17.9 L+₹2.2 L (13.8%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹21.0 L
EMD Value
₹42,028
Closing Date
6 Sept 2021, 5:00 pmClosed
EXECUTIVE ENGINEER NORTH 24 PARGANAS ELEC DIVN
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION PUBLIC WORKS DIRECTORATE TOP FLOOR, MECHANICAL COMPLEX, BAGUIATI, KOLKATA 700 059
Renovation and Upgradation work of E.I with ancillary works in Dr.B.R.Ambedkar Sports School,Banipur,North 24 Parganas
2021_WBPWD_341014_1
WBPWD/EE/N24PRG/ELEC/66/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Dr.B.R.Ambedkar Sports School, Banipur, North 24 Pgs
Please refer Tender documents.
6 documents required · 6 mandatory
₹42,028
29 Sept 2021
19 Aug 2021
8 Sept 2021
20 Aug 2021
6 Sept 2021
24 Aug 2021
Amount
A. High Mast Light Installation & Compound & llumination-Supply and fixing of 16 M height high mast shaft in two sections suitable for wind speed 50m/s made up from HTS conforming to BSEN100025 with head frame , luminaries carriage suitable to install 8 nos luminaries in symmetrical arrangement, lightning arrester terminal -1 no with accessories required such as winch, 8 mm dia SS wire rope two continious rope, with integral power tool motor, manual handle,junction box, foundation bolt etc as required.high mast shall be hot dip galvanised by single dipping method as per BSEN ISO 1461 (Make-Bajaj/Transrail/Utkarsh/Jindal)
Erection with foundation of the high mast with suitable tools and tackles as directed by EIC.
S and F of 215-225 W LED flood light fittings.(Make-Philips/Crompton/Wipro)as directed by EIC.
Supply of 7 Mtr. height dip galvanised octagonal pole made of HT steel of grade S355 of BSEN 10025 with 130mm bottom A/F & 70mm top A/F made up of 3mm thick G.I. sheet along with base plate of size 200x200x12mm thick with in built terminal box for cable connection as required (BOP-7030). Including foundation accessories & 1.5 mtr single arm bracket. Also Bakelite sheet with two 6A SP MCB and 16sqmm stub type connector is considered (Make-Bajaj/Transrail/Utkarsh/Jindal)
Supplying & Fixing GI waterproof type looping cable box size200x150x100 mm deep having 4 mm thick comprising of one 250V 15 A kit-kat fuse unit, one NL on porcelain insulator, onecompression type brass cable gland for upto 2- core 16 sqmmPVC/A cable and having lined with rubber gasketted GI top coverwith brass machine screws etc., earthing terminal with lug, onsteel tubular pole near base, including S&F 40x6 mm thick, MSclamps with bolts, nuts etc. including painting with anticorrosive paint.
S & F of 70-74 W LED Street light fittings.(Make-Philips/Crompton/Wipro) as directed by EIC.
Erection of M.S. octagonal poles 7M including Making R.C.C. foundation including earth work in excavation of foundation pit making R.C.C foundation and also including supply of all materials e.g cable entry pipes,anchoring bolts and nuts,washers,sand,cement,coars aggregate,reinforcement rods etc and refilling of pit duly rammed and finished complete as per direction of and up to satisfaction.
Supply &delivery of 1.1 KV Gr. XLPE/A. Al. Cable of undermentioned size. (Make-KEI/Gloster/Polycab/RR/Havells)-i) 4core 10 sq mm (For High Mast from Existing feeder Pillar & Street Light Pole)
Laying of one No. cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed-i) 4core 10 sq mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables and finishing the end with socket and jointing materials-i) 4core 10 sq mm
SITC of 250V Timer in special DB is size double door sheet metal enclosure with neutral bar DIN rail with 1no. 20/25 A DPMCB, 1 No. 24 hrs programmable timer switch with minimum switching time of 15mins and 1 no 18/25 AQ contractor single phase motor starter (compact 25A min) complete with internal wiring with suitable size of copper wire incl. 1no auto manual bypass change over switch and provision for e/a. incl. LED indicating light with locking arrangement as per direction of EIC(Make-Legrand/L&T)
Earthing with 50 mm dia By ISI-Medium GI pipe of 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level with excavation of soil for installation of Earth Electrode and filling & ramming.
B. Hostel Renovation-Supply and fixing of 32 A, 240V DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall.(Make-Havells) (For Hostel)
S&F 415 V, (2+10) way double-door SPN MCB Distribution Board Enclosure with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.: (Make- L&T/Legrand) Incomer: 40 A DP Isolator Outgoing: 10nos 6-16A SPMCB
Supply &delivery of 1.1 KV Gr. XLPE/A. Al. Cable of undermentioned size. (Make-KEI/Gloster/Polycab/RR/Havells)-i) 2 core 16 sq mm (From Overhead pole to Main Switch)
ii) 2 core 6sq mm (For compound light)
Laying of one No. cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed-i) 2 core 16 sq mm (From Overhead pole to Main Switch)
ii) 2 core 6sq mm (For compound light)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables and finishing the end with socket and jointing materials as -i) 2 core 16 sq mm
ii) 2 core 6sq mm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-RR/Havells/KEI/Polycab) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make-Legrand Arteor/ Crabtree Amare/Panasonic Vision) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] (Average run 8 mtr)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-RR/Havells/KEI/Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish (On Board)
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works-19 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make-RR/Havells/KEI/Polycab) of the following sizes in the prelaid Polythene pipe and by the prelaid GI fish wire and making necy. connection as required-2x6 sqmm + 1x4 sqmm as ECC (For SPNDB )
Distribution wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-RR/Havells/KEI/Polycab) partly in 20mm size PVC rigid conduit 'FR' (Precision make) incl necy fitting as required.-i) 3 x 1.5 sq mm
S & Fixing 18-20W double poly carbonate LED Tube light fitting with 2 nos 18-20 W LED tube lamp suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos.fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.(Make-Philips/Crompton/Havells/Wipro/Magik/Panasonic)
S & Fixing 18-20W single LED poly carbonate Tube light fitting with 1 no LED tube lamp suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos.fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.(Make-Philips/Crompton/Havells/Wipro/Magik/Panasonic)
Supply & Fixing of 1200mm, 240V AC ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. (Make- Usha Striker Galaxy / Crompton Aura Prime/Orient Quasar Ornamental)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing Socket type fan regulator (Step type) (Make-Legrand Arteor/ Crabtree Amare/Panasonic Vision) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supply & fixing 11 W LED on batten point as per direction of EIC(Make-Philips).
S & F 12” sweep 1420 RPM AC Exhaust fan incl. making hole on wall with nuts & bolts as required with louver shutter as per GS (Make-EPC Heavy duty)
Supply of outdoor flood LED luminaries 50-55 W outdoor fittings (Make-Philips/Crompton/Wipro) complete with all accessories as required for Compound Illumination from the parapet.
Supplying and Fixing (200x150x100)mm GI water proof looping cable box havinghinged GI Top Cover having 4 mm thick with rubber gasketlining, railway type mechanical locking arrangement, earthingterminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL onporcelain insulator etc.
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required.
Supplying & fixing medium gauge 40 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Earthing with 50 mm dia By ISI-Medium GI pipe of 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level with excavation of soil for installation of Earth Electrode and filling & ramming.
C.Electrical installation work in Toilet Block (5 Nos)-Supply & Fixing only 240V ,16 A DP Sheet Steel Main Switch (Rewirwable type) on flat iron Frame on wall (Make-Havells)
Supplying and fixing 2 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole16A MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment.(Make-Legrand/L&T)
Supply &delivery of 1.1 KV Gr. XLPE/A. 2core 6 sq mm A/Al. Cable of under mentioned size. (Make-KEI/Gloster/Polycab/RR/Havells).
Laying of one No. 2core 6 sq mm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of cable 2core 6 sq mm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing of 2core 6 sq mm compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables and finishing the end with socket and jointing materials
Supplying & fixing medium gauge 25 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-RR/Havells/KEI/Polycab) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make-Legrand Arteor/ Crabtree Amare/Panasonic Vision) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed](Average run 5 mtr)
S & Fixing 18-20W double poly carbonate LED Tube light fitting with 2 nos 18-20 W LED tube lamp suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos.fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.(Make-Philips/Crompton/Havells/Wipro/Magik/Panasonic)
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supply & fixing 9W LED on batten point as per direction of EIC(Make-Philips).
Supply of outdoor flood LED luminaries 50-55 W outdoor fittings (Make-Philips/Crompton/Wipro) complete with all accessories as required for Compound Illumination from the parapet.
Supplying and Fixing (200x150x100)mm GI water proof looping cable box havinghinged GI Top Cover having 4 mm thick with rubber gasketlining, railway type mechanical locking arrangement, earthingterminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL onporcelain insulator etc.
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required.
Earthing with 50 mm dia By ISI-Medium GI pipe of 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level with excavation of soil for installation of Earth Electrode and filling & ramming.
D. Staff Quarter-Supply and fixing of 32 A, 240V DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall.(Make-Havells)
S&F 415 V, (2+8) way double-door SPN MCB Distribution Board Enclosure with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.: (Make- L&T/Legrand) Incomer: 40 A DP Isolator Outgoing: 8nos 6-16A SPMCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-RR/Havells/KEI/Polycab) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Make-Legrand Arteor/ Crabtree Amare/Panasonic Vision) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed](Average run 8 mtr)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-RR/Havells/KEI/Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish (On Board)
S & Fixing 18-20W double poly carbonate LED Tube light fitting with 2 nos 18-20 W LED tube lamp suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos.fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.(Make-Philips/Crompton/Havells/Wipro/Magik/Panasonic)
S & Fixing 18-20W single LED poly carbonate Tube light fitting with 1 no LED tube lamp suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos.fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.(Make-Philips/Crompton/Havells/Wipro/Magik/Panasonic)
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Supply & fixing 9W LED on batten point as per direction of EIC(Make-Philips).
Supply &delivery of 1.1 KV Gr. XLPE/A. 2core 6 sq mm A/Al. Cable of under mentioned size. (Make-KEI/Gloster/Polycab/RR/Havells).
Laying of one No. 2core 6 sq mm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of cable 2core 6 sq mm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing of 2core 6 sq mm compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables and finishing the end with socket and jointing materials
Supply & Fixing of 1200mm, 240V AC ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. (Make- Usha Striker Galaxy / Crompton Aura Prime/Orient Quasar Ornamental)
Supply & Fixing Socket type fan regulator (Step type) (Make-Legrand Arteor/ Crabtree Amare/Panasonic Vision) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
S & F 12” sweep 1420 RPM AC Exhaust fan incl. making hole on wall with nuts & bolts as required with louver shutter as per GS (Make-EPC Heavy duty)
Supplying & fixing medium gauge 25 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Earthing with 50 mm dia By ISI-Medium GI pipe of 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level with excavation of soil for installation of Earth Electrode and filling & ramming.
SATABDI ENGINEERING COMPANY
EASTER CONSTRUCTION COMPANY
SILICON SOFTWARE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .