Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC T C NO 26 1461 1 SL ELECTRICAL WORKS S L TOWER UR 43 UPPALAM ROAD STATUE UPPALAM ROAD THIRUVANANTHAPURAM KERALA 695001 | THIRUVANANTHAPURAM | KERALA | 695001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.6 L+₹20,855 (2.23%)Rejected-Finance ERNAKULAM | KERALA | 680667 | L2 | Rejected-Finance L2 |
Tender Value
₹10.6 L
EMD Value
₹26,500
Closing Date
21 Mar 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AEE, Fort Zonal Office, Tvpm Corporation
AEE, Fort Zonal Office, Tvpm Corporation
proj no 1818 Kumarichantha electrification in Ambalathara ward
2022_LSGD_481524_1
4/AEE/1818/Fort/21-22
Open Tender
Electrical Works
Item Rate
90 days
Fort Zonal Office
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,150
Yes
₹26,500
Yes
23 Apr 2022
14 Mar 2022
23 Mar 2022
14 Mar 2022
21 Mar 2022
14 Mar 2022
60 days
Amount
90.2.1.1. Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single Control light point with 6A, 3 plate ceiling rose -
90.2.1.3. Single control light point with out ceiling rose
90.2.1.17. Single control light point with out ceiling rose
90.2.1.4. Single controll seleing fan point with 6 A, 3 plate ceiling rose and with socket typped electronic regulator.
90.2.1.18. Single controll seleing fan point with 6 A, 3 plate ceiling rose and with socket typped electronic regulator. (long point)
90.2.1.6. Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
90.2.1.21. Independent Plug (long point)
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture
Supply and fixing angle / straight brass lined skirt type, bakelite batten holder without shade and giving connection etc as required with 10 W LED bulb.
90.4.1. Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.4.5.2..Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
Supply, and providing every additional length of down rod of suitable size heavy gauge GI/WI pipe with 16/0.20 mm 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting and giving as required.
MR 1194 150 mm sweep light duty exhuast fan in plastic body with self opening lowers working on 230 V single phase A/C supply.
1.27.4. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200 x 75 mm)
1.24.5. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 socket outlet
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
(90.6.4.2) Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 1.00 sq mm 2 run
90.6.4.14 1.50 sqmm 4 run
90.6.4.22 2.50 sqmm 2 run
(90.6.4.32) 4.00 sq mm 2 run
90.6.4.34 4.00 sqmm 4 run
90.6.4.42 6.00 sqmm 4 run
(90.6.4.42) 6.00 sq mm 4 run
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 6 way Double door)
2.3.4. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 16 way, Double door
2.4.4. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 4 way, (4+12) Double door
2.13.2. Supplying and fixing following rating, 4 pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.12.1 Supplying and fixing following rating,double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.2. Supplying and fixing 5 A to 32 A rating, 240/415 volts, "C" curve, MCB for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.15.3 Supplying and fixing following rating four pole 415 V RCCB having asensityvity current upto 300 mA in the existing MCB DB complete with connections testing and commissioning etc as required 63 Amps
2.14.2. Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
or Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc. as required (14 SWG)
or Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc. as required (10 SWG)
5.4 Earthing with G.I. earth plate 600 x 600 x6 mm thick including accessories and providing masonry enclose with cover plate having locking arrangement and watering pipe of 2.7 mm llong etc. with charcol/coke and salt as required.
or Supply and laying supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level excavating trench of suitable size and refilling etc. as required. (in ordinary soil) 3.15 mm copper conductor (10 SWG)
90.15.4.3. Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18.2 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
90.15.4.4 Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
S & F switch disconnector unit (isolator) complete with handle assmebly, door inter lock and padlocking arrangement of the following ratings
32 A DP SDF
or Supply and fixing the following accessories in the existing meter board and giving connection etc.
32A, 415V, DIN type fuse base
32A, 415V, Backelite fuse fitting
32A, 415V, 2 way neutral link mounted on DMC/SMC base
Amount remitted to KSEB for obtaining power supply
B SASIKUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_691865.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .