Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical KOCHUVEETIL TOWERS MODEL SCHOOL JUNCTION THAMPANOOR THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | Accepted-Technical L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
2 Jun 2026, 11:00 amClosed
Registrar, Kannur University
Kannur University, Thavakkara Campus, 670 002
Retender for the work of renovation of Auditorium at Dr. Janaki Ammal Campus, Palayad
2026_KnrU_850985_1
PLD/E5/ 17686/2025
Open Tender
Civil Works - Others
Item Rate
Dr. Janaki Ammal Campus, Palayad, Kannur Universit
Please refer Tender documents and NIT
10 documents required · 10 mandatory
₹5,900
Yes
₹50,000
Yes
6 Aug 2026
15 May 2026
3 Jun 2026
15 May 2026
2 Jun 2026
15 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1CIVIL WORK | |||||
| 1.01 | 12.45.2 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) | 0.6 | Sqm | - | - |
| 1.02 | 12.45.4 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. | 1 | Sqm | - | - |
| 1.03 | 12.57 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-inCharge | - | Sqm | - | - |
| 1.04 | OD167710/2025-2026 Supply and fixing of Accoustic wall panelling using G.I Metal stud panelling using 48mm G.I.Studs placed at 595 centre to centre in 50mm floor channel and ceiling channel fixed with top and bottom and laying 50mm glass wool for insulation and accoustical purpose and then fixed 12.5mm thick Gyp.tone tile, size is 595mm x 595mm and fixing fibre tape with jointing compound for full finish on joints including applying one coat of putty and one coat of primer, two coats of Emulsion paint with fully finished for false ceiling/panelling | - | Sqm | - | - |
| 1.05 | OD151853/2025-2026 Preparation of wood surface for melamine polish. | - | Sqm | - | - |
| 1.06 | 13.114 Melamine polishing on wood work (one or more coat). | - | Sqm | - | - |
| 1.07 | 15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | - | cum | - | - |
| 1.08 | 15.12.1 Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below | - | each | - | - |
| 1.09 | 15.40.2 Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead:Thickness above 40 mm upto 75 mm | - | Sqm | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.55 MB
BondTermiteproof.pdf
Tender Documents • 0.24 MB
FormofTender.pdf
Tender Documents • 0.15 MB
Preliminaryagreement1.pdf
Tender Documents • 0.28 MB
Requisitionforepayment.pdf
Tender Documents • 0.24 MB
DeclarationnotBlacklisted.pdf
Tender Documents • 0.14 MB
sbdcompositetenderGO.pdf
Tender Documents • 2.53 MB
Formofaffidavit.pdf
Tender Documents • 0.25 MB
IntegritypactCertificate.pdf
Tender Documents • 0.23 MB
BOQ_1438022.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .