| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.4 LAccepted-AOC DOOR NO 65 4 64 1A KOTHA NAKKAVANIPALEM MALKAPURAM POST VISAKHAPATNAM 530011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹61.4 L Quoted ₹61.7 L | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹62.3 L+₹60,767 (0.98%)Rejected-Finance | ₹62.3 L+₹60,767 (0.98%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹62.4 L+₹72,452.57 (1.17%)Rejected-Finance | ₹62.4 L+₹72,452.57 (1.17%) | L3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | L4₹63.9 L+₹2.2 L (3.58%)Rejected-Finance | ₹63.9 L+₹2.2 L (3.58%) | L4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | L5₹65.9 L+₹4.2 L (6.83%)Rejected-Finance | ₹65.9 L+₹4.2 L (6.83%) | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹68 L
EMD Value
₹1.3 L
Closing Date
17 Mar 2022, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs to Building No. P 28 MO V Visakhapatnam
2022_MES_508427_1
82236 / E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class C
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Depot
₹1.3 L
Yes
30 Mar 2022
17 Feb 2022
22 Mar 2022
17 Feb 2022
17 Mar 2022
3 Mar 2022
17 Feb 2022 - 24 Feb 2022
Amount
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Stairs [Framed] including Stringers, Treads, Landing, Balusters, Hand Rails etc including cleats, brackets, etc complete all as specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165, as in framed work such as Grills, Gratings, Ladders etc with ends of bars shouldered and/or riveted, or forged into spikes, framed Guard Bars, Barred Iron Doors, Ladders, framed Balusters, Walk Ways, Railings, framework of Water Tanks and similar work complete all as specified and as directed.
M & L for cutting holes into or through RCC Slabs, Chajjas, Beams, Columns etc. for superficial area exceeding 100 Sq.cm and not exceeding 250 Sq.cm complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for Plain cement concrete Type C1 1:3:6 using 20mm graded stone aggregate cast in situ in lintels up to 1.5m span, Cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator frames, Partitions with one or more rebates including jointing cleat for fixing, glazing clips, rubber beading etc complete all as specified and as directed. Note: The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I.
S & F Aluminium Powder Coated [Minimum 50 Micron thick] Sections as in Doors, Window and Ventilator Shutters, Sidehung type, without sash bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Aluminium Powder Coated Snap Beading, Screws, Aluminium Powder Coated Fittings such as Peg Stays 150mm Long [1 No], Hinges, Type B-21 100mm Long [2 Nos], Suitable Handle [1 No] per Shutter complete all as specified and as directed. Note: [a] Supply only panel inserts of Glass shall be measured and paid separately. [b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless steel Friction Hinges and fixing only of panel inserts of glass etc.
Supply only 5mm thick sheet Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
M & L for Preparing surfaces of wood and wood based materials, steel and iron work new or old, of any description and treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of Chowkats etc. area tarred exceeding 0.1 Sq.m but not exceeding 0.5 Sq.m each with tar or coal tar black paint complete all as specified and as directed.
S & F Factory made, 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165 as in Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes, including Bolts, if required, Hooks [Stay], heavy, for Large Gates, Hook and Pintle Hinges, large Hasps and Staples, Chains, hand made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
S & F 75mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed.
S & F 100mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
S & F Solid PVC door frame of size 100mmX45mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
S & F in repairs Steel rolling shutters, thickness of laths of 1.00 mm, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position, Push and Pull Type complete all as specified and as directed.
S & F in repairs Collapsible Steel Gates, Top Hung, consisting of Channel Pickets, Pivoted Flat Bars, Top and Bottom Runners, Brass Handles etc. as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
Making good under cills [or over arches, lintels and bressummers] including all pinning as necessary complete built in Cement Mortar 1:4 complete all as specified and directed.
S & F in repairs Stainless steel curtain rod, 25 mm dia with fixing brackets, end caps etc complete all as specified and as directed.
M & L for 50 mm thick PCC 1:2:4, Type B-1, using 20mm graded aggregate as in Flooring, surface finished even and smooth without using extra cement complete all as specified and as directed.
M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Sub base for flooring complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring using 20 to 25mm thick slabs, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for machine cut Kota stone slab as in riser of steps, skirting, dado etc. using 20 to 25mm thick slabs laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including borders, margins in two or more shades of slabs over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for Chequered Cement Concrete Tiles of size 200 X 200 mm, 25mm thick, Hydraulically pressed as in Floors, set jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Supply only Liquid Water Proofing Compound [ISI marked] of approved make.
M & L for preparing newly plastered Wall surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on Wall surfaces complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparation of old decorated surfaces including brooming down or steel wire brushing and applying one coat of white wash on ceilings complete all as specified and as directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for washing, rubbing down and stopping of distempered and painted surfaces of walls and applying one coat of Acrylic Washable Distemper on wall surfaces complete all as specified and as directed.
S & F 15mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing, taking down or up unserviceable steel tubing and connections of any description complete all as specified and as directed.
S & F 20mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing, taking down or up unserviceable steel tubing and connections of any description complete all as specified and as directed.
Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
S & F in repairs PP-R Gate Valves [Brass Insert] suitable for 20mm outer dia complete all as specified and as directed.
S & F Making connection of PP-R distribution branch with PP-R main of size 15 / 20mm by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
S & F in repairs Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed.
S & F in repairs Stop Valves, 15 mm dia, cast copper alloy, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and as directed.
S & F in repairs Ball Brass Valve, 20 mm dia, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S & F in repairs Stainless Steel, Tubular Towel Rail, D Type, 600 mm long complete all as specified and as directed.
S & F in repairs 125mm size Stainless Steel grating for Floor Traps complete all as specified and as directed.
S & F in repairs Glass Shelf with Bracket, 600mm Long complete all as specified and as directed.
Taking down CI pipes of any dia (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed .
S & F 160mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 160 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 75mm bore outlet PVC [SWR] Floor Trap with grating including jointing with solvent cement complete all as specified and as directed.
S & F in repairs white Vitreous China Squatting Pan "Orissa Pattern" of size 580 mm X 440 mm with integral foot rests and 'P' or 'S' Trap including provision of lime concrete bedding and 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe complete all as specified and as directed.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
S & F Calcium Silicate False Ceiling at all heights in true horizontal level made out of Calcium Silicate Tiles of size 595 X 595 mm, having Integral densified reinforced edges of 15mm thickness all around with a collar of width 24mm and 10mm thickness at the centre of siliceous and calcareous material reinforced with cellulose fibre of approved texture, design and patterns, suspended on the Exposed Metal Frame Ceiling Grid of 600mm x 600mm size and applying one coat of Acrylic Washable Distemper and including suspended Exposed Inter-locking Metal Frame Work using GI Main "T" Runner of size 24x38mm, 0.33mm thick, spaced 1200mm centre to centre, Cross "T" of size 24X32mm, 0.33mm thick, 1200 mm long spaced between Main "T" at 600 mm centre to centre to form a grid of 1200X600 mm and secondary Cross "T" of 600mm long and of size 24X32mm, 0.33mm thick of the 1200x600mm panel to form grid of size 600x600mm, resting on periphery walls / partitions on GI Perimeter Wall Angle of size 24X24X3000 mm, 0.40 mm thick with the help of rawl plugs at 230mm centre to centre with 40mm long dry wall SS Screws including cutting/making opening for services like diffusers, grills, light fittings, smoke detectors etc., wherever required. Main "T" Runners shall be suspended from ceiling using galvanised mild steel [Galvanizing @ 80 Grams per Sq.m] 50 mm long, 8 mm outer diameter M-6 Dash Fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-Shape level adjuster of size 85x25x25x2 mm, spaced at 1200mm centre to centre along Main "T". Bottom exposed width of 25 mm of all sections shall be pre-painted with polyester baked paint at all heights including dismantling of existing ceiling board with frames complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point / switch including taking down carefully existing point wiring of any description and cutting chasing for concealed wiring as required and making good the disturbed surfaces all as per existing complete all as specified and as directed.
All as per Serial Item No. 76 above but One Light point controlled by 02 Nos. of two way Switch complete all as specified and as directed.
All as per Serial Item No. 76 above but One 3 Pin Socket Outlet 5 Amps on independent Board complete all as specified.
All as per Serial Item No. 76 above but One 3 Pin Socket Outlet 5 Amps on same Board complete all as specified.
All as per Serial Item No. 76 above but one AC / Water Cooler / Geyser point on independent board, with 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Switch, Modular Type, One Module, Single Pole, 6 Amps, 230 Volts, one way complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 2/3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps cum 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 4 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 6 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
S & F in repairs TP & N Enclosure with 3 Pole and Earth Metal Plug & Socket for incorporating TP MCB complete including One MCB, TP, 63 Amps, 415 Volts complete all as specified and as directed.
S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs including making good disturbed surfaces complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 4 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs including making good disturbed surfaces complete all as specified and as directed.
S & F in repairs MCB DB, VTPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs/MCCBs cincluding making good disturbed surfaces complete all as specified and as directed.
S & F MCB, SPN, 40 to 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCCB, FP, 100 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCCB, FP, 63 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCB, FP, 63 Amps, 10 KA, B Curve, AC, 415 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, FP, 100 Amps, 10 KA, B Curve, AC, 230 Volts/400 Volts, 50 Hz complete all as specified and as directed.
S & F in repairs Integral LED Aviation Light of Make & Cat No. BGAV 302 LED of M/s. Bajaj or equivalent approved makes, comprising of aluminium housing with polycarbonate enclosure including standard fixing arrangements and connecting up complete all as specified and as approved. Note: Light fitting shall be of PF>0.95
S & F Recess mounted Energy efficient LED Ceiling Light fitting, 40 W capacity, 230 Volts, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser, of size 600mm X 600mm, suitable for fixing in 2 X 2 Grid False Ceiling including necessary cutting to existing false ceiling and making good disturbed surfaces and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down of existing light fittings complete all as specified and as directed. Note: Light fitting shall be of PF>0.90
Taking down Light Fittings of any description, any type and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including cleaning and minor repairs complete all as specified and as directed.
M & L for Taking down Ceiling Fan/ Air circulator/ Pedestal Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, replacement of Spares such as Capacitor 2.5 Mfd, Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
Taking down Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 Mfd, Bearings, Shaft Bushes, Condenser, Rubber Bushes, Nuts & Bolts etc. and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
Supply and fixing Rigid non-metallic PVC conduit of 20mm dia including junction boxes, all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking down of existing unserviceable PVC pipe complete all as specified and as directed.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
S & F in repairs Aluminium Strip of size 25 X 3.15 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed.
S & F in repairs Earth continuity conductor or main earthing lead made of 4 mm GI Wire [Earth Lead] , fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
Supplying and laying GI pipe, 40mm dia, light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps including taking down of existing unserviceable GI pipe complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
RAMESH ASSOCIATES
ESWAR ENTERPRISES
TECHNO SOFT SOLUTIONS
Ruchira Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .