| 1 | L1₹28.9 LAccepted-AOC | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹37.3 L+₹8.4 L (28.9%)Rejected-AOC 63 MANDIR LANE BALLUPUR CHOWK DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC R | |
| 3 | L3₹37.5 L+₹8.5 L (29.5%)Rejected-AOC | L3 | Rejected-AOC R | |
| 4 | L4₹37.6 L+₹8.7 L (30.1%)Rejected-AOC INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L4 | Rejected-AOC R | |
| 5 | L5₹38.0 L+₹9.1 L (31.3%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L5 | Rejected-AOC R |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
24 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
PROVN OF CERTAIN REVENUE AND MINOR WORKS UNDER AGE EM AT IMA DEHRADUN
2022_MES_571562_1
GE/IMA/T-84 2022-23 9276/E8
Open Tender
Support/Maintenance Service
Item Rate
90 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹96,400
Yes
2 Mar 2023
27 Dec 2022
26 Jan 2023
28 Dec 2022
24 Jan 2023
10 Jan 2023
Amount
S & F sub main wiring 2 x 4Sqmm + 1 x 4 Sqmm with PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in and including rigid PVC conduit in concealed / surface as required at site including PVC insulated unsheathed cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as specified and directed. Note :Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. Make:- M/S Bonton cables/Finolex/Polycab/GEMSCAB/ Havells.
S & F sub main wiring 2 x 6Sqmm + 1 x6 sqmm with PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in and including rigid PVC conduit in concealed / surface as required at site including PVC insulated unsheathed cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as specified and directed. Note :Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. Make:- M/S Bonton cables/Finolex/Polycab/GEMSCAB/ Havells
S & F sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20 Amps, , complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. Make:- C&S/Havells/Legrand/ABB
Supply and fix Electric water heater ,storage type steel body with copper inner tank and heating element upto 2 kw capacity 25 ltr BEE 5 star rating complete with all acessories such safety valve ,thermostate,NRV ,connection pipe including fastener for fixing and including taking down old unsv switch, complete all as specified and directed. Make:- Havells/Crompton /Jaquar
S & F MCB SP 6 to 32 Amp.240 volts complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. Make: Legrand, L&T, ABB, Schneider
S & F MCB SPN 6 to 32 Amp.240 volts complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. Make: Legrand, L&T, ABB, Schneider
M & L for Drilling and Tapping water mains ( in position) for branch connectionby inseting tee as per site requirement including saddle piece and nuts and bolts, complete all as directed.
Supply and Fix Tube medium gradega vanised 15mm dia with all fitting and fixed complete to wall and ceiling of laid under floors complete all as specified.
Supply and fix Hot water pipe duly insulated with glass wool and alluminium clading 15mm bore complete all as specified.
Supply and Fix Self closing tap cast copper alloy,chromium plated 15mm dia, complete all as specified.Make- Cera/Prayag/Jaquar(Essako).
Supply and Fix angle cock cast copper alloy,chromium plated 15mm dia, complete all as specified.Make- Cera/Prayag/Jaquar(Essako).
S & F Distribution boards epoxy powder coated TP & N 8 Way VTPN DB (FP MCCB +24 MCB,s) fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with 250 Amps fully insulated copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 DB,S protection,415 volt ,suitable for fixing FP MCCB 100/125 Amps as incomer and 24 SP MCBs or 4/8/ 12 TP MCBs (or any combination of SP/TP MCBs) outgoings capacity & making good the distrubed surface complete all as directed. Note: Suitable MCCB and outgoing MCBs will be measured separately under relavant items of this schedule) Make:- Legrand,L&T,ABB, Schneider
S & F MCCB ,100 Amps ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 18 KA with thermal-magnetic release and adjustable overload setting . The MCCB shall have a Mechanical life = 40000 operations & Electrical life = 8000 operations of following capacity complete all as directed. Make: Legrand, L&T, ABB, Schneider
Supply and laying XLPE insulated armoured heavy duty electric cable of size 25 Sqmm x 3 1/2 Core with aluminium conductor ,1100 volts grade as specified and directed. Make: POLYCAB/Finolex/GEMSCAB/Gloster/Bonton cables/Havells
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, or for shafts, wells, cesspits, manholes, pier holes, etc. and not exceeding 10 Sqm on plan and getting out in soft /loose soil complete all as specified and as directed
Returning filling including spreading leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed.
M&L for sand cushioning to UG cables (8 Cm deep before laying of cable and 15Cm deep over the cable) Note : Punned thickness will be measured.
Suppy and laying un-reinforced precast cement cable cover ,cass LV,type -I flat size 250x150x40mm complete all as specified. Make:- Tulip/NTC/Mahtab
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
S & F MCB SPN DB 8 way complying with IEC 61439 -1 & 3., sheet metal enclosures double door .The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed. Make: Legrand, L&T, ABB, Schneider
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm thick GI wire by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to main switch board,including all necessary excavation & earth work in hard dense soill including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternate layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed.(one earthing for each main Panel ).
Material and labour for point wiring for One exhaust fan point controlled by one, one way switch with PVC insulated and unsheathed electric able 1100 volts grade single core FRLS having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in and including Concealed /on surface non mettalic rigid PVC conduit not less than 20 mm dia with all fitting and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & sunken steel boxes zinc oxide plated of suitable size, for mounting modular switch, sockets, regulators and modular inner and outer cover plate etc. ISI marked. Make of wire: Finolex, Polycab, Grandlay,Bonton cables. Make of conduit: Finolex, Ess Ess Kay, ICL, AKG Note: (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
S&F switch piano, flush type, single pole one way 6 Amp complete all as directed.
Supply and fix ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed.
Supply and fix exhaust Fan ,steel body complete with louvers ,voltage 230 volts ,50HZ,RPM 1400,copper winding of sweep 300mm including cutting holes on wall and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface complete all as specified. Make:- Crompton/Bajaj/Havells/Usha
Supply and fix exhaust Fan ,made of Engineer Plastic complete louvers shutter ,voltage 230 volts ,50HZ,RPM 1200,copper winding of sweep 300mm including cutting holes on wall and making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface, complete all as specified. Make:- Crompton/Havells/Bajaj/Usha
S & F MCB SPN 40 to 63 Amp.240 volts complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. Make: Legrand, L&T, ABB, Schneider
S & F MCB DB SPN 4 way complying with IEC 61439 -1 & 3., sheet metal enclosures double door .The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed. Make: Legrand, L&T, ABB, Schneider
Supply, installation, testing and commissioning including transportation at site Hi wall split type Air Conditioner (Hot and cooled) 5 star rated of cap 1.5 TR working on AC singles phase 230 volts, 50 Hz, complete with indoor and out door units along with all accessories as supplied by manufacturer including making necessary arrangement for fixing of indoor & out door units by using the bracket are recommended by manufacturer with proper bolits, nuts & washer etc complete inlcuding necessary civil work & electrical cable connection with 3 core PVC insulated copper conducter as supplied by manufacturer and making necessary refrigerant pipe connection duly insulated properly and initial charging of gas all as specified by manufacturer etc complete all as directed at site Make:- Voltas/Samsung/LG Note:- The contractor has to make good of the surface as per existing which has been distured during installation of Air Conditioner units and allied services.
Supply and install voltage stabilizer having following features i.e High power efficiency, intelligent Time delay system (3mnts+/-20 sec ITDS), inrush current capablity etc. For automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 volts to 300 volts with output voltage stabilized at 230 volts with accuracy of +/-2.5% and capacity 20 Amps complete model No. VWR DX 500 of V-Guard or equivalent in Bluestar/V-Guard/Servo
Meher enterprises
M/s Anamika Enterprises
KRISHANA ELECTRIC WORKS
BK CONSTRUCTION
JAIN BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .