| 1 | Admitted-Fee/PreQual/Technical/Finance KEETHADATH HOUSE INKKUR P O 670503 | INKKUR | KANNUR | KERALA | 670503 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance PUTHIYA VEETTIL HOUSE PERUMPAZHASSI ARALAM KANNUR | ARALAM | KANNUR | KERALA | 670141 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.9 L
EMD Value
₹7,257
Closing Date
22 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ATHUL ARAVIND
Office of the Assistant Engineer, LID EW Section, Panoor Municipality
GENERAL-Panoor Municipality-INSTALLATION OF MOTOR AND PIPELINE AND RELATED WORKS AT ATHIYOOR KULAM Pro no S0343/26-Project No-S0248/25-General Electrical Work
2025_LSGD_809337_35
AE/LSGD/PNR/11/2025
Open Tender
Electrical Works
Item Rate
180 days
Office of Assistant Engineer, Panoor Municipality
Please refer Tender documents.
7 documents required · 7 mandatory
₹645
Yes
₹7,257
Yes
24 Oct 2025
15 Oct 2025
24 Oct 2025
15 Oct 2025
22 Oct 2025
15 Oct 2025
Amount
wiring
OD148485/2025-2026:Supply conveyance installation testing and commissioning of 5 HP Vertical/Horizontal multistage,3 phase submersible pump motor,50/50 mm suction /Delivery pipe, up to 90 meters head 6-15 lts LPS delivery(Kirlosker/cromption/equlent make) in the existing open well, giving mechanical and electrical connection and trial run etc.as required.
OD148121/2025-2026:Dismantling the existing 1 to 3/ HP,1/3 phase submersible pump motor from the well, and lifting the pump up to the ground level dismantling the pipe attached with the pump and conveyance to o the Section store
OD148484/2025-2026:Supply conveyance installation 40/50 mm HDPE flexible Pipe(6 to 10 Kg /cm
OD148533/2025-2026:Supply installation testing and commissioning of MS/CI 50/63/75 mm cast iron Non Return Valve
OD148534/2025-2026:Supply conveyance and providing 50/63 mm Stainless clip
OD148535/2025-2026:Supply conveyance and providing 50/65 mm GI hose coller
90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
OD148507/2025-2026:Supplying and fixing of following sizes of PVC pipe 50 mm dia 10 kgf/cm2- 6-10 kg along with accessories in surface including jointing of pipes& fittings with one step PVC solvent cement and testing of joints clamping 1.00 m spacing/recess including cutting the wall and making good the same in case of recessed conduit as required.
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
OD148129/2025-2026:Supply conveyance and providing 12 mm nylon rope.
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD148128/2025-2026:Supply and providing the 25 x 3mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD148123/2025-2026:Supply and providing the 12 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD148127/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required
OD148122/2025-2026:Supply and providing test joint for the earthing system using 2 x 25 x 3 mm GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD148126/2025-2026:Supply and fixing the following accessories in the existing meter board and giving connections etc.32 A fuse holder with fuse link
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
OD148125/2025-2026:Fabrication of fully partitioned, dust and vermin proof enclosure for as per form 4 of IS 8623 (with latest amendments) using1.6 mm CRCA sheet as per approved design and requirement, with front access facility, hinged doors for switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs, powder coating the assembly after subjecting to 7 tank process etc as required.The measurements will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD148130/2025-2026:Supply and providing 7/5 Watts LED Bulb in the existing fittings as required
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
OD151704/2025-2026:SITC of Decorative Pole 3 metre height above the ground level made out of GI,tubular pole ‘T’ washed and primered (ASTM A123) with dia of 76mm. The pole shall be with inbuilt junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out and with MS base plate.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design comply EN40 standard and basic wind speed 169kmph. Pole should be hot dip galvanized to 65 microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats of epoxy primer and above that it should be given with polyurethane UV resistant coating (painted with avg. DFT of 70μm). The complete system should be hot dipped Galvanised. (3M pole Kesclec make ECO POLE/3 m Bajaj Eco pole/equivalent)
OD151819/2025-2026:SITC of LED Decorative Classic luminaire of system wattage 30W, BIS certified with a body and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06) fixed on to the optical unit, separate optical and control gear compartment accessed by opening four screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as required. The luminaire shall have ingress protection of IP66. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of 110lm/W at correlated colour temperature (CCT) 3000K, colour endering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, ated voltage 240Vac,Power Factor ≥ 0.95, with BIS certified potted driver having nternal surge protection of 4 kV and an additional surge protection device (SPD) of 10 V. ( KESSLEC RILA 30W WW LED/equivalent)
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
90.16.1.9:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.64 mm GI conductor (12 SWG)
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD151858/2025-2026:Supply and fixing Analog timer of Havells(Cat No.DHTED30016) or similar make of Theben,OBO, L&T etc.
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
OD151862/2025-2026:Supply and installation of 3/4 pole contactor suitable for controlling High /Low mast light as required.
SUNIL KUMAR P V (BID ID -2405323)
Bidder Name
MANSOOR KEETHADATH
SUNIL KUMAR P V
finance_1351301.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 0.25 MB
Tendernotice_3.pdf
PDF • 0.25 MB
FOT.pdf
Tender Documents • 0.25 MB
AFF.pdf
Tender Documents • 0.24 MB
NIT.pdf
Tender Documents • 0.34 MB
BOQ_1351301.xls
BOQ • 0.35 MB
viewsbd.pdf
Tender Documents • 1.63 MB
PA.pdf
Tender Documents • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .