Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.9 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹20.5 L+₹1.3 L (6.61%)Rejected-AOC D 47 MANORATH SOCIETY NEAR AMAR COMPLEX SAMA ROAD VADODARA 390024 | VADODARA | GUJARAT | 390024 | 2 | Rejected-AOC NOT L1 | |
| 3 | 3₹21.3 L+₹2.1 L (10.7%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | 3 | Rejected-AOC NOT L1 | |
| 4 | 4₹21.8 L+₹2.6 L (13.7%)Rejected-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | 4 | Rejected-AOC NOT L1 | |
| 5 | 5₹22.5 L+₹3.3 L (17.0%)Rejected-AOC | 5 | Rejected-AOC NOT L1 |
Tender Value
₹23.3 L
EMD Value
₹46,500
Closing Date
8 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AHMEDABAD
CWE AHMEDABAD
SPL RRPAIR TO BLDG NO P 193/01 TO 04 OF EME SCHOOL UNDER GE ARMY BARODA
2021_MES_439768_1
86982
Open Tender
Civil Works
Item Rate
180 days
BARODA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
₹46,500
Yes
19 Nov 2021
3 May 2021
10 Jun 2021
3 May 2021
8 Jun 2021
27 May 2021
60 days
Amount
Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar.
M&L for non skid colour ceramic tile 7 to 8 mm thick area of each tile joint free exceeding exceeding 0.11 sqm but not exceeding 0.18sqm , as in floors etc set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6 (Tile pattern and decoration may be as suggested by Engineer-in-charge)
M&L for non skid colour ceramic tile 7 to 8 mm thick area of each tile joint free exceeding exceeding 0.11 sqm but not exceeding 0.18sqm , as in skirting/dado etc set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6 (Tile pattern and decoration may be as suggested by Engineer-in-charge)
M & L for Glazed ceramic coloured walls tiles in vertical surfaces 300x450x 6mm to 7 mm thick set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including rendering for screed bed on vertical surface of wall or concrete surfaces in CM 1:4 to receive wall tiles (Tile pattern and decoration may be as suggested by Engineer-in-charge).
Demolition of reinforced cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, chullah hood and similar suspended work
Cement concrete type B1 1:2:4 (20 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges.
Taking down cement plaster on brick/concrete surface including racking out joints hacking for key scrubbing down with water etc.
Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc,
Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6
M & L brickwork with sub class ‘B’ bricks straight or curved to any radius in half brick thick walls built in CM 1:4
Rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement)
M&L Rendering in two layer on fair faces of brick work or concrete sur-faces of wall 5 mm thick in CM 1:4 mixed with WPC @ 3% by wt of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately).
Rendering 10 mm thick on fair faces of brick work or concrete sur-faces of ceiling in cement mortar 1:4 for finished even and smooth (without using extra cement)
Supply only Internal water proofing compound all as specified and directed.
M & L for preparing new plastered surfaces of wall and applying two coats of oil bound distamper over and including a coat of 1 to 1.5mm average thick birla/ equivalent wall care putty and one coat of primer. (Note : Putty shall be measured and paid separately under relevant Item)
M & L for complete removal of old existing treatment completely by scrapping and or rubbing of wall and applying two coats of oil bound distamper over a coat of 1 to 2mm average thick birla/ equivalent wall care putty and one coat of primer. (Note : Putty shall be measured and paid separately under relevant Item)
M&L preparing new/old plastered surfaces of wall and applying 1 to 2 mm thick layer of Birla/J K Wall care Putty all as specified and directed. .
M & L for preparing new plastered surfaces of wall and applying two coats cement base paint over a coat of primer on external wall.
M & L for preparing old decorated surfaces of wall applying one coat of cement base paint on external wall
M & L for preparing new plastered surfaces of ceiling and applying three coats of white wash.
M & L for preparing old plastered surfaces of ceiling and applying two coats of white wash on ceiling to match the existing surfaces.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each
Taking down chowkats or frame with shutter (without taking off shutter from the frame) Exc 1.5 Sq m but n.exc 4.00 Sq m each
M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved by EIC/GE.
S & F 35mm thick 2nd class Hard wood Glazed and Skelton shutters, open rebated and prepared to receive glass, gauze etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut ,mitered and moulded beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(a) and fitted to chowkats.
S&F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F of Powder coated aluminium window/ventilator shutters, side hung/sliding type aluminium sections including necessary joining cleats, sash bars, glazing clips rubber neoprene packing, anodised aluminium snap beading, screws and grill etc as per manufactures instruction & trade pactee.
S&F 4.00mm thick figured glass, pin head type and glazing with rubber beading or with glazing clips, all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.
M&L for 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/PVC door frame with screw complete all as specified and directed.
S & F 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed
S & F 150 mm size extruded aluminium alloy handles, febricated type anodised
S & F 300 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters
S & F solid PVC door frame of size 50mmx47mm made out of 5mm prelam PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing and matching with door shutter shade. The door frame shall be tied to the wall using 75/100mm long MS screw as directed .
S & F 30mm thick factory made both sides prelam panel PVC door shutter consisting of frame made out of MS tube of 19 gauges thickness and size 19mm x 19mm for stiles, top and bottom rails, MS frame shall have a coat of steel primer of approved make and manufacture. MS frame shall be covered with 5mm thick heat moulded prelam PVC C channel size 30mm thickness, 70mm width, out of which 50mm should be flat and 20mm shall be tappered in 45 degree < on either sides forming stiles and 5mm, 95mm wide prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide. prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tappered on both sides to form lock rail. Top rail, bottom rail and lock rail shall be provided either sides of the panel 10mm (5mm x2) thick 20mm wide cross PVC sheet shall be provided as gap insert for top rail, and bottom rail paneling of 5mm thick both side prelam PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with 7mm (5mm+2mm) thick 15mm wide. PVC sheet beading on inner side and jointed together with solvant cement adhesive, an additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of C channel using PVC solvant adhesive etc. complete all as specified and directed.
S & F 125 mm aluminium alloy handles, cast type anodised all as specified.
S & F 150mm aluminium anodised barrel tower bolts of extruded section and fixed.
S & F in repairs 25mm dia stainless steel 202 grade tubular curtain rod as directed
S & F in repairs stainless steel socket fancy type with bracket for 25mm dia stainless steel tubular curtain rod (design of socket shall be approved by GE/AGE at the time of execution) as directed
S & F in repairs 20mm dia brass chrom plated tubular towel rail complete.
Providing and fixing factory made 18(+0.7mm) thick PVC sheet one sided pre laminated sheet cabinet shutter. 18 mm(+0.7mm) thk sheet shutter of density 600 kg/m3 bent at 90o and finished all edges at all level for making edges, Lipping/bending or 0.5 mm thk PVC sheet lipping at all four edges using bonding tape etc complete all as per directions of enginer in Charge, Manufacturers's speciifcations.
S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M & L for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate to fix hold fast complete all as specified and directed.
M & L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
M & L for preparing new wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
S & F 16 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S & F 15mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
Refixing of old galvanised mild steel medium grade of dia 20mm bore tubing and connections in new or old position with all new fittings and fixed complete to walls and ceilings or laid in floors all as directed.
S & F 20mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
S & F 25mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
Dismantling cast iron pipes, jointed in cement mortar for 100 mm bore
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall all as specified and as directed.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) bends any radius all as specified and as directed.
Dismantling cast iron pipes, jointed in cement mortar for 75 mm bore
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall all as specified and as directed.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) bends any radius all as specified and as directed.
S & F 110mm PVC (SWR) vent cowl all as specified and as directed
S & F 75mm PVC (SWR) vent cowl all as specified and as directed
S&F in repairs vitreous China squatting pan of Orissa pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including P or S trap etc and provision of lime concrete bedding complete all as specified and as directed.
S & F 110mm PVC (SWR) WC connector with lip ring all as specified and as directed.
S & F 110mm PVC (SWR) WC connector bent type to fit WC outlet all as specified and as directed.
S & F 110mm PVC (SWR) junction single, (Single T, 'Y' type) equal or unequal all as specified and as directed.
S & F 75mm PVC (SWR) junction single, (Single, 'Y' type T) equal or unequal all as specified and as directed.
S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 110mm bore pipe all as specified and as directed
S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 75mm bore pipe all as specified and as directed
S & F in repair 75mm PVC (SWR) floor trap, plain with CP grating including jointing with solvent all as specified and as directed.
S & F in repairs 15mm bore chromium plated fancy type bib tap long body, screwed down, high pressure for iron pipe or for brass ferrule
S & F in repair CP wall mixer three in one system for mixing hot and cold wather screwed down for iron pipe 15 mm bore and fixed complete all as specified and directed. Make : Cera/Prayag/Jaquar or equivelent make.
S & F in repairs stop valves/Angle valve15mm bore fancy type chromium plated screwed both ends for iron pipe or for unions and fixed
S & F in repairs 25mm dia bore gun-metal,globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed
S & F 125mm dia chromium plated shower rose with swivel joints including fixing to GI union complete
S&F 32 mm bore low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2 as in waste pipe
Dismantling of water storage tank of 500 ltrs capacity.
S & F 1000 Ltrs Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
Disconnecting existing tanks of 500 ltrs to 1000 ltrs capacity, setting aside (or lowering if required) for repairs cleaning etc and hoisting if required reconnecting and re fixing in position. Cleaning and removing of all scale and dirt etc from tanks and from mouths of circulating pipes etc. including all necessary fittings if required complete all as specified and as direct
S & F in repairs Ball brass valves, for 25 mm bore of pipe high pressure, with polythene float and fly- nut complate, screwed for iron pipe or brass ferrule and fixed
S&F in repair vitreous china Wash hand basin, white , flat back size 550x400 mm except taps, CP waste coupling but incl brackets all as specified. Make cera/Hindware
Supply and fixing CP Centre hole Wash Basin mixer three in One 15 mm bore pipe complet all as specified. Make : Cera/Prayag/Jaquar or equivelent make.
S & F 32 mm dia stainless steel waste coupling for wash hand basin all as specified and directed. Make : Prayag or equivalant.
S & F PVC connections 15mm size with PTMT nuts of length 450mm
S & F Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm including suitable waste coupling and waste pipe. (Make : Nirali (Elegance), blue star, Jayana, Prayag or equivalent
Supply & Fix of stainless steel wall mounted plate rack of size 900x1200X 300 mm and thickness of sheet not less than 0.50mm with provn for keeping plates and other crockery fixed with screw and rawal plug etc on wall complete all as specified and as directed
M & L for complete removal of loose / cracked concrete incl reinforcement if required, from RCC roof projection,chajja,fins,facia, roof bands etc and making good with PCC (1:11/2; :3) type A0 (using 12.5 mm graded stone aggregate) in any slab and in any position finished the surface even and smooth with out using extra cement including necessary form work and welding/binding of reinforcement (including reinforcement) if required complete and applying three coat of white wash/two coat of cement base pint to match with the existing surface as directed by the Engr- in -Charge . (Reiforcement will be measured and paid saperately under respective item.
M&L for Providing precast cement concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to matchcomplete all as specified and directed. (reinforcement shall be measured and paid separately)
M&L for Providing reinforced cement concrete (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note. (reinforcement shall be measured and paid separately)
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specifed and as directed.
M & L for 16 to 18 mm thick machine cut green marbel stone in single piece in riser of steps, skirting, dado, window (Jambs/Cills), and pillar laid over cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10 mm thick plastering with cement mortar 1 : 4 complete all as specified
M & L for 16 to 18 mm thick machine cut green marbel stone as in flooring, in steps in single piece over cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15 mm thick plastering with cement mortar 1 : 6 complete all as specified
M & L for machine cut kota stone slab flooring 20 - 25mm thick set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6
M & L for machine cut kota stone slab 20 - 25mm thick in skirting, riser etc set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including rendering for screed bed on vertical surface of wall or concrete surfaces in CM 1:4 to receive wall tiles.
M&L for complete removal of existing water proofing treatment including plaster and concrete padding, roughening of concrete surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
M&L for 75 mm avg thick PCC padding in cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggr with water proofing compound @2% by weight of cement finished surface even and smooth without using extra cement for laying of WPT all as specified and directed.
M&L for 10 mm thick plaster on roof surface with CM 1:3 mixed with water proofing compound @3% by weight of cement plaster surface should be even and smooth without using extra cement all as directed. Note . (WPC will be measured and paid separately).
M&L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying actetic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minium 3.50 Kg/Sqm 3 mm thick (minium) with minium 75 mm side overlaps and minium 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete all as specified and directed by Engr-In-Charge
M & L for brushing with neat cement slurry @ 3Kg/Sqm
M & L for Cement concrete tiles 25cm x 25cm x 22-25mm thick, m a c h i n e pressed; laid over 15mm thick cement screed in CM 1:6, set, jointed and pointed in neat cement slurry with WPC @ 3% by wt of cement in floors/roof top complete all as specified and directed (WPC will be measured and paid separately).
M & L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed
M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed
M&L for sunken treatment of WC/Bath with polymeric membrance (APP based) with non woven polyster mat as reinforcement including water tightness test with filling of water for continuous 48 hours with following :-
Demolition of existing PCC /lean concrete including floor tiles and removing rubbish off the premises.
M&L for 15 mm thick plaster in sunken portion with CM 1:3 mixed with water proofing compound @3% by weight of cement plaster surface should be even and smooth without using extra cement all as directed. Note . (WPC will be measured and paid separately).
M&L for providing & laying APP based polymeric membrance of weight of 3 kg/sqm with non woven polyster fibre as reinforcement over a coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm by torch application with side over laps & longitudinal joints over laps etc as per manufacturer instructions complete all as specified and as directed..
M&L for sunken portion filled with lean concrete 1:5:10 using brick/lime aggregate and finish the surfaces rough to receive sub base complete all as specified and as directed.
M & L for 25 mm thick cement concrete in flooring type Bo, 1:2:4 (12.5mm graded aggregate) with water proofing compound @3% by weight of cement for laying floor tiles. Note (WPC will be measured and paid separately).
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thickness (below or above ground level)
M & L for 75 mm thick PCC 1:3:6 mix type C2 as in plinth protection and paving finishing cone surface even and smooth without using extra cement
M & L for Forming 65mm deep x 10mm thick contraction (dummy joints), filled with sealing compound grade "A".
Taking down shutter exc 1 Sqm but n.exc 2 Sqm each
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Dismantling and taking out submain wiring 2/3/4/6 wire of any size and taking out from site all as directed by Engineer-in-Charge.
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade, conforming IS 694 & color code in conduit system of wiring, drawn in including medium grade PCV conduit not less than 20 mm dia concealed, including cutting chases, finising of slote by means of cement mortor making good to the existing surface of the wall & touching with the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.2mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet6 fixed with brass screw and washer with all accessories including single core solid conductor copper 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified.
(a) One light/fan/bell point controlled by one switch 6 amp one way
(b) One 3 pin switch socket combination 6 amp on the independent board.
(c) One 3 pin switch socket combination on same board with other switches.
(d) All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
(e) One light point controlled by two 2 - way switches, with cables 1.5 sq. mm size ®
S&F MCB DB SPN 8 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed.Make: Legrand/Schneider/C&S
S & F MCBs DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V complete all as directed by Engr-incharge. Make: Legrand/Schneider/C&S
S&F MCBs 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB Make: Legrand/Schneider/C&S (DB will be measured and paid separately under respective items of sch A):-
(a) MCB SPN 6 to 40 Amps.
(b) MCB SP 6 to 40 Amps
Supply and Fix MCB TPN,63 Amps 4-Pole, 415 volts, breaking capacity10 KA complete all as specified,Make: Legrand/Schneider/C&S
M&L switch piano flush type single pole, one way 6amp .
M&L switch piano flush type single pole, two way 6amp .
M&L switch socket combination 5 pin 6 amp.
M&L switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type.
S/fix fan regulator electronic type equivalent code No 38660 of Anchor make
S/fix ceiling rose 65x17mm three terminals .
S& F lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting with 9watt LED bulb
M&L switch flush type bell push button 6 amp.
M&L Electronic ding dong bell AC 230V single pole .make anchor/ Bajaj/philps
Sub main wiring with two single core PVC insulated and unsheathed FR multi stranded copper conductor cable 1100 volt grade IS-694,marked of 6.0 sqmm size drawn through and including 20mm dia PVC conduit medium grade ISI marked and conduit junction boxes,terminal boxes and accessories such as tees, bends, elbows, reducers,bell mouth tube ends fixed to the surface of wall/ ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FR multi stranded copper conductor cable for earth wire continuity conductor.
NOTE : Two runs of single core cable 6.0 sqmm respectively and one run of 6.0 sqmm copper FR cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
Supply, Fixing, Testing and commissioning of 4' LED not less than 1X18W LED Batten with LED tube not less than 18 watt. Similar to Batten cat Part No.REGALBATTEN8UPTO1X22wSSBSWH and LED tube light cat part No.CRYSTAL1213T8DSTL18WLED865SGLASS of Make- Havells or equivalent in Make: Philips/Wipro/CG
M&L earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 5 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipw,15mm dia,medium grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
Supply, Fixing, Testing & Commsioning of IP65 integral LED Bulk Head luminaire. Power Consumption should not exceed 10W (Including Driver Loss). Similar to cat Part No. RUGBYNEONFT10WLED760SSYMBOPC of Make- Havells or equivalent in Make: Philips/Wipro/CG
Supply, Fixing, Testing & Commisioning of 2' not less than 10W Mirror LED Batten .Mounting on two PVC square boxes of size not less than 75mm X 75mm complete including connecting fitting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose complete all as specified & directed. Make- Havells, Model-ENDURALINEARNEOBS10W LED 830SPCWH or equivalent in Wipro/Philips/CG
S & F wall security light LED type not less than 20W . The Luminaire connecting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose complete with GI pipe suitable bend 1.2 mtr long and fixing on wall/pole with clamp, nut & bolt complete all as directed and specified by Engr-In-Charge. Make- Havells, Model-ENDURACITYLITEPLATSL20W LED 757SASYBOPC or equivalent in Phillips/Wipro/CG.
Supply and fixing ceiling fan 1200 mm sweep BEE 5 star rated including fixing of down rod and connection complete with & including provision of flexible three core PVC insulated multi-stranded copper conductor cable of size 0.50 sq mm from ceiling rose/connector to fan complete all as specified and directed. Make : Crompton Greaves or equivalent in Bajaj/Orient/Usha Note: Old UNSV ceiling fans will be deposited to AGE E/M office
Supply and fix AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 1P LCD Meter 5-30A with Optical port + BOX. Similar to Model EM101+ Class 1 Base mounting and cat part No.WM101BC5DDHBOX of make L&T or in equivalent model of Capital/Cyantech/HPL. Note: Old UNSV ceiling fans will be deposited to AGE E/M office
Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for LAN and TV Socket
M&L for PVC Junction boxes (1 to 4 way)
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on plan and getting out in soft/loose soil.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point
Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in soil completed all as specified and directed
M&L for sand cushoning, to cable with river sand and punning to provide required cover for UG cables all as directed at site.
M&L brick protection cover to electric cable with class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm.
Supply and laying or fixing or passing through pipe,XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 25 sq. mm 3.5 Core .
M&L for galvanized steel tubing light Grade of 40 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Shree Vaishno Enterprises
Dagli Engineers
Badri Electricals
CENTAUR ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .