| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST BIDDER | |
| 2 | L2₹11.3 L+₹33,170 (3.03%)Rejected-Finance 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹11.7 L+₹69,689 (6.36%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹12.3 L+₹1.3 L (11.8%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹13.1 L+₹2.2 L (19.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
20 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (CG) Vizag
AGE (I) (CG) Vizag, Military Engineer Services, CGWO Building, C/o Fleet Mail Office, Visakhapatnam, PIN-530011
REPAIR/MAINTENANCE OF EXTERNAL E/M SERVICES STREET/SECURITY LIGHTS AND ALLIED WORKS AT ICGS KAKINADA UNDER AGE(I)(CG) VIZAG
2024_MES_656022_1
AGE(I)CG/VIZ/TOKEN 11 OF 2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
VISAKHAPATNAM
DETAILS AS PER NIT OF THE TENDER
9 documents required · 9 mandatory
₹29,000
AGE (I) (CG) Vizag
₹29,000
Yes
16 Jul 2024
27 May 2024
22 Jun 2024
27 May 2024
20 Jun 2024
7 Jun 2024
Amount
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10 sqm on plan and not exceeding 1.5mtr in depth and getting out complete all as directed.
Returning, filling including spreading leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
Supply and lay cable cover for LT Cable Class LV,type 1 , flat size 250mmx150mm x 40 mm.
M&L for XLPE insulated, LT armoured electric cable with aluminium standared conductor 1100 volts grade, cross-sectional area 10 sqmm, 2.00 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers etc. and testing complete all as specified and directed. Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
All as per Srl Item No. 6 here-in-before but cross-sectional area 10 Sqmm x 4 core
All as per Srl Item No. 6 here-in-before but cross-sectional area 16 Sqmm x 4 core
All as per Srl Item No. 6 here-in-before but cross-sectional area 25 Sqmm x 3.5 core
All as per Srl Item No. 6 here-in-before but cross-sectional area 35 Sqmm x 3.5 core
All as per Srl Item No. 6 here-in-before but cross-sectional area 50 Sqmm x 3.5 core
Filtration & Dehydration of transformers oil at ICGS Kakinada Substation to achieve di-electric strength not less than 60 KV at 4mm gap as per relevant IS with portable filteration plant, testing of the oil for the di-electric strength before and after filteration complete all as specified and directed by Engr-in-Charge.
Supply only transformer oil conforming to IS 395-1983 (Make : 'Savita', 'Power Oil', APAR or equivalent as approved by the AGE) having die electric strength minimum 60 KV/4mm gap, complete all as specified and directed.
Overhauling of step down outdoor/indoor transformer 250 KVA, 11/0.433 KV by disconnecting HT/LT terminals, descalinnning transformer oil, removing sludge, cleaning of HT /LT bushings to remove dust particles /dirt etc, cleaning the core and winding with compressed air and reassembling complete including replacement of copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet suitable for transformer top cover, terminal boxes, refilling the transformer oil after filteration and dehydration and toping up with new transformer oil, painting with two coats of synthetic enamel paint and testing and recommissioning on load etc, complete for the transformers of following rating:- Note:-(Filterationand dehydration of transformer oil and supply only transformer oil for topping up supply only of HT & LT bushings shall be measured and paid separately under respective items)
Suppling and laying in repair Synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 Kv for electrical purpose as per IS 15652-2006, (Superseding IS 5424) suitable for electrical shock safety of sizes 2 m x 1m complete all as specified and directed.
Shifting of Transformer of 100KVA capacity from Kakinada sub station to workshop located in visakhapatna within 200 KM and shifting back to substation kakinada substation after repair incl lifting of transformers from the substation for loading/ unloading into transporting vehicle with the help of crane at workshop & Substation, including disconnecting & connecting HT/ LT and earthhing connection transformer and restoration of power supply including all T&P required complete all as specified and as directed. Note:- The unit rate qouted against this items shall be deemed to include cost of transportation of transformer and T&P required for both sides.
M&L for Disconnecting HT/LT connections of burnt / defective copper wound transformer of capacity 100KVA, taking down from site of installation, opening up the top cover, draining out transformer oil from transformer in suitable containers (containers to be provided by the contractor) inspection/assess the defective / bumt parts, core assembly of transformer in the presence of Engr-in-Charge and then shifting the transformer to trade / contractor's workshop for repair, cleaning and making good surface for rewinding and rewinding the same with existing size of new copper conductor, strip wound coils, limb for HT/LT, fixing of class 'E' insulation in core assembly etc. including internal cleaning, removing sludge, washing and spray painting with one coat of synthetic enameled paint (existing colour) on outer side after cleaning and removing oil spot from the body and re- assembling, re-installing, commissioning the transformer to its original place and testing at site on full load after connecting the HT/LT connections complete all as directed by Engineer-in-charge. Notes:- (i) HT/LT copper coil, transformer oil and other required parts shall be measured and paid separately under respective item of this Sch in supply and fixing. (ii) Unit rate quoted against this item shall be deemed to include cost for T&P / minor parts / nut bolts etc. cutting/chipping of RCC/PCC/ plastering of foundation/platform and other necessary minor work.
M&L for rewinding of distribution transformers of any capacity / size / type by strip opening & rewinding the HV coils (i.e. primary coils) from core assembly safely. removing old defective insulation paper, re-winding the coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed.
All as per Sl item No. 18.00 here-in-before but but for LV Coils
M&L for replacement of silica gel breather assembly complete suitable for 100 to 250 KVA transformer as per existing with breather unit and silica gel including connecting with proper necessary gaskets if necessary & removing the unserviceable breather assembly complete all as specified and as directed.
S & F of porcelain HT bushing vitreous, brown colour, 11 KV grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing HT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for primary side (HT side) of outdoor type 11 KV for 63 KVA upto and including 500 kVA distribution transformer of any make complete all as specified and directed by Engr-in-charge.
S & F of porcelain LT bushing vitreous, brown colour, 440 V grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing LT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for Secondary side (LT side) of outdoor type 440V for 63 kVA upto and including 500 kVA distribution transformer of any make complete all as specified and directed by Engr-in-charge.
M & L for replacement of gasket including arresting leakage of transformer oil by after draining out of transformer oil and refilling after replacement including disconnecting power supply complete all as specified and as directed for distribution transformer outdoor type 11 kV /415 volts having capacity upto 500 KVA complete all as specified and as directed by Engr-in-charge.
M&L for preparation of old exposed painted surfaces of indoor/outdoor type transformer of capacity 100 to 250 KVA and painting the same with two coats of synthetic enamel paint including writing details of transformer on transformer plinth / base with white synthetic enamel paint on black synthetic enamel paint back ground complete & including one coat of white wash on exposed surface of transfomer plinth/base complete all as specified and as directed. Note: Colour of paint shall be as decided by Engr-in-Charge. Make:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
Supply and fix in repairs FRP cable looping box of size 250 x 200 x 105 mm With connector block 4 Way , including provision for 1 Nos of MCB SP 6 Amp, copper shorting strips etc including suitable stainless steel gland, including provision for connecting earth continuity conductor etc. all as specified and directed. Make : Syntex Model GSJB 2520 /Hensel
Supply and fix in repairs FRP cable looping box of size 140 x 140 x 95 mm With connector block 4 Way , including provision for 1 Nos of MCB SP 6 Amp, copper shorting strips etc including suitable stainless steel gland, including provision for connecting earth continuity conductor etc. all as specified and directed. Make : Syntex model GSJB 1414 /Hensel
S&F in repair of LED Street light driver of 25 watt, 230 V, 50 Hz suitable for operation on voltage range of 140 V to 270 Volt by removing from existing position complete all as specified and as directed by Engr-in-Charge. Make: Philips/Havells/Crompton/Surya Note : i) T & P / Ledder required for carrying out repair work on street lights at a height up to 15 mtr will be arranged by the contractor and cost of the same deemed to be included in quoted rate. ii) Contractor is bound to provide material to match the technical specification of LED fitting and to suit to be fixed in the casing of LED fittings.
All as per item no. 27 here-in-before but of capacity 45 Watts
All as per item no. 27 here-in-befor but of capacity 70 Watts
Supply and fix in repairs LED street light fittings 25 Watts Pressure die cast aluminum housing, heat resistant toughened glass with frame, IP66 protection better optics for uniform distribution including connrction wire from polr box to light of make Havells Cat No. ENDURASUNDOWNSL25WLED765PASYBOPCIHD or equivalent complete all as specified and as directed.
Supply and fix in repairs LED street light fittings 45 Watts Pressure die cast aluminum housing, heat resistant toughened glass with frame, IP-66 protection better optics for uniform distribution including connection wire from pole box to light of make Havells Cat No. ENDURASUNDOWNSL45WLED765PASYBOPC or equivalent complete all as specified and as directed.
Supply and fix in repairs LED flood light fittings 120 Watts Pressure die cast aluminum housing, heat resistant toughened glass with frame, IP-66 protection better optics for uniform distribution including connection wire from pole box to light of make Surya Cat No.SLE FL 120W IP66 LMS NEO or equivalent complete all as specified and as directed.
Supply and fix in repairs LED BAMBOO BOLLARD light fittings 08 Watts energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source including connection wire from pole box to light of make Havells/ Crompton/Surya/Bajaj or equivalent complete all as specified and as directed.
Supply and fixing in repairs of automatic street light switch using NATURE SWITCH for automatic switching of steet light based on LUX level of natural light. The sensor (nature switch) along with suitable power contactors MCBs in incoming and outgoing side, copper short links in contractors, PVC insulators for incoming and outgoing circuit for support, copper cable copper cable of 16 sqmm for incoming and outgoing 63 amps MCBs and 02 Nos support terminals to support timer box on pole/wall , encloser made of rust proof, electric shock proof, termite proof and FR grade SMC jucntion box (make conforming to IP-54 suiatble for single phase of 5 kw model swadeep -02 ECKW15 Make - Nature switch/ Legrand/Siemmens
S & F in repairs GI Bracket made out of 40 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clame of size 40x6 mm with necessary nut bolts & washers and applying two coats of aluminum enameled paint over one coat of zinc oxide primer for clamp complete all as specified and directed
S & F in repairs GI Bracket made out of 25 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clame of size 40x6 mm with necessary nut bolts & washers and applying two coats of aluminum enameled paint over one coat of zinc oxide primer for clamp complete all as specified and directed
M&L for GI pipe 40 mm dia "light grade" laid in trenches floors/on pole/road for cable protection with all fittings complete all as specified and directed.
All as per item no. 37 here-in -before but 50 mm dia
M&L in repair of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 5 of SSR Pt-I 2009 specification.
M & L for repairing of broken earthing pits chamber with PCC (1:3:6) type C-1 with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipe including Painting with White cement colour (Red/Green/Yellow) of earthing pits of diffirent colour as per Earthing type (Chemical/Lightening Protection and Conventional ) all as directed by Engr-in-charge.
M&L applying two coat of aluminium paint on steel tubular pole 9/11 m long, including preparation old surfaces, filling cavities and lettering the Pole no in figures, complete all as directed by Engineer-in-charge.
M&L preparation of old HT Steel 4 Pole Structure 11 mtr height with connected cross arms, cable protection pipes, clamps etc and including applying one coat of aluminium paint on complete height including preparation old surfaces, filling cavities and lettering the Pole no in figures complete all as directed by Engineer-in-charge.
M&L for painting all parts of LT panel / feeder pillar box, with two coat of synthetic enamel paint with and including preparation old surfaces, filling cavities and letter and figures, complete all as directed by Engineer-in-charge.
S&F in repairs MCCB 400 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
S&F in repairs MCCB 400 Amp capacity, 3 Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
S&F in repairs MCCB 250 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
S&F in repairs MCCB 250 Amp capacity, 3Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
S&F in repairs MCCB 160 Amp capacity, 3 Pole, 415 Volt grade, rupturing capacity 25kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
S&F in repairs MCCB 100 Amp capacity, 3 Pole, 415 Volt grade, rupturing capacity 16kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
S&F in repairs MCCB 63 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 16kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified. Make : Legrand / L&T / Siemens / ABB
S&F in repairs Boom Barrier/boom gate ( it is a bar, or pole pivoted to allow the boom to block vehicular or pedestrian access through a controlled point) including replacement of PCB.Control card, motor, power supply unit, suspension with mechanism, boom, barrier cover. Remote sensor i.e electromechanical complete all as specified abd as directed. Note: The contractor may visit the site and exmine the existing boom barrier at site before quoting their rates and no extra cost will be entertained by the department for this account.
SVG SUPPLIES
RAMESH ASSOCIATES
SRI SRK ENGINEERS
PAVANI INFRAS
SRI LAKSHMI GANAPATHI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .