Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.0 L+₹3,830 (0.16%)Rejected-AOC PSRA 146 A PULIMOOTTIL ROAD PADAMUGAL INDRA JUNCTION KAKKANAD PO KOCHI 682030 | KOCHI | ERNAKULAM | KERALA | 682030 | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.3 L+₹36,340 (1.52%)Rejected-AOC S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | L3 | Rejected-AOC L3 | |
| 4 | L4₹24.9 L+₹95,603 (3.99%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹25.0 L+₹1.1 L (4.62%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
17 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
CERTAIN SANCTIONED WORKS UNDER AGE EM NO. II.
2023_MES_603527_2
8257/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kochi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹60,000
Yes
21 Sept 2023
3 Aug 2023
19 Aug 2023
3 Aug 2023
17 Aug 2023
4 Aug 2023
Amount
Supply and Lay UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 120 Sqmm with suitable cable gland including taking down of old unserviceable cable complete all as specified and directed.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 95 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 50 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 3.5 core 25 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 4 core 16 Sqmm.
Ditto All as per Sl Item No 1, but aluminium conductor of size 4 core 10 Sqmm.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation of pole and laying of underground electric cable in soft/loose soil complete all specified and directed.
Supply and spread River Sand for cushioning and covering of UG cables in trenches complete all specified and directed. (Note : For measurement purpose only punned thickness shall be measured and paid)
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all specified and directed.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all specified and directed.
Supply and laying reinforced precast concrete cable cover, Class LV, Type 1, flat, of size 250mmx150mmx40mm complete all as specified and directed
Material & Labour for GI tubing of size 40mm dia light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc complete all as specified and directed.
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 45 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers PCC 1:2:4 over hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fixing aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish compatible for all Havells post top range 3.0 Metre height, Mild steel base plate of 268 mm dia, and two sections which having a dia of 110mm and a height of 970 mm for bottom section and a dia of 76mm and a height of 2530mm height for top section, and plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connections & mounting accessories including necessary PCC foundation and earthwork etc complete all as specified and directed. Make shall be as per Havells Cat Part No DECO pole 3M TOPǾ76MM or Equivalent in Philips/Bajaj/ Crompton.
Supply and fixing LED post top lantern die-cast aluminium spigot for mounting LED driver and spun aluminium canopy which is painted white inside, epoxy powder coated matt black finish after phosphochromate treatment and light source of High efficiency long life LED module with SMD LED package mounted on MCP CB and viewing angle of 116 degree suitable for mounting with OD of 70 mm max with 3 Nos hexa screw etc of capacity 25 watts complete all as specified and directed.
Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm X 40mm X 6mm thick frame work and CRCA sheet 3mm thick having Aluminum bus bar of rating 400 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves, The size of the outer shell should not less than 750mmX 750mmX 500mm, mounted on angle iron stand made out of size 40mm X 40mm X 6mm grouted of digital volt meter & Amps meter with CTs, with and including the following items, taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 400 Amps aluminium strip - 1 Set (b) MCCB 250 Amp 35 KA 4 pole - 01 No ( Incoming) (c) MCCB 63 Amp 25 KA 4 pole - 04 No (Outgoing) (d) Volt meter digital 0-500 volt - 01 No (e) Amp meter digital 0-300 Amp - 01 No (f) Indicator lamp Yellow, Red, Blue - 01 Set
Material & Labour for straight through joint 3.5 core 95 to 120 Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 25 to 50 Sqmm with all accessories complete all specified and directed.
Material &Labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Metres below ground level) with top edge of earth plate not less than 1.5 Metres below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering funnel with 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point or LT panel etc, and testing on completion, complete all as specified & directed by Engineer-in-Charge.
Supply, install, testing and Commissioning of 7 Metre GI Octagonal pole single section with bottom dia 135mm, top dia 70mm having sheet thickness 3mm, The door height cut-out should not be more than 500mm with door elevation 500mm, The size of the reinforced rod should be 30x4mm, Size of the base plate should be 220x220 mm with thickness of base plate 16mm. PCD for the holes should be 225 with foundation bolt dia M20, length of the foundation bolt 700mm with four foundation bolts. The Arm should be 1 Metre length single arm with 15-degree Arm bracket. The total height of the pole should be 7000 mm above the finished Ground level including PCC foundation, J Bolt, nuts and washers as per the drawing of Manufacturer complete including taking out the old unserviceable RCC pole complete all as specified and directed. Make shall be as per Crompton Cat Part No HM-1107P or Equivalent in Philips/Bajaj/ Havells.
Supply, fixing, testing & commissioning of LED 90Watt Street Light with Die cast Aluminium body, Toughened glass with secondary lens with IP-66 Protection, The Surge Protection should be 10KV with more than 110 lumen/Watt including taking down old one all as specified and directed Make shall be as per Crompton Cat Part No Nexus Neo CRP-404-90-57-SL-GL-NSG or Equivalent in Philips/Bajaj/ Havells.
Material & Labour for Brick well burnt Class 'B' as in cover to UG cable, laid dry, flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over UG cable for cable protection in trenched complete all as specified.
Supply & Fixing street light TIMER control panel, 65 Amps, 3 pole/230Volt, DIGITAL time switch pole/wall mounting made out of 3.15 mm CRCA sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements and as manufactures recommendation and design complete all as specified and directed. Make shall be as per Indo Asian Cat Part No TL065DB0 or Equivalent in L&T/Schneider/ Havells.
Material & Labour for PVC insulated copper conductor 3 core 1.5 Sqmm cable to be drawn inside the pole , including taking down of old one, all as specified and as directed.
Supply, Install, testing and commissioning of 10 KVA UPS single phase input 170 to 270 Volt, 50 Hz and single phase out put 230 Volt +/- 1% , IGBT technology pure sine wave LCD display. output PF 0.8 Lag, Crest factor 3:1 inbuilt galvanic isolation transformer, Auditable at output over load and battery low with 12V, 200 AH 16 Nos SMF battery with interconnecting cable for approx 3 hours backup including metal battery stand complete all as specified and directed.
Supply and Lay UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 25Sqmm with suitable cable gland complete all as specified and directed.
Material & Labour for sub main wiring along with earth wire with the 2 runs of 6 Sqmm PVC insulated copper conductor, single core cable in surface wiring through PVC conduit along with one run of 6 Sqmm PVC insulated copper conductor single core for earth continuity cable complete all as specified and directed.
Supply and Lay UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 2 core 10Sqmm with suitable cable gland complete all as specified and directed.
Supply and fix in repair, junction box made of glass fibre reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including one MCB SP, 6 Amps and suitable size clamps fixing for pole/in PCC foundation etc, including taking down the old one complete all as specified and as directed.
Material & Labour for relocating of tubular poles of any size from one place to another place duly removing all connection carefully without any damages of Flood light and losses any parts, dismantling foundation and including earth work with foundation erecting the poles at new place as per the direction of Engineer In Charge and necessary Painting with two coats of aluminium paint over one coat anti corrosive paint, including preparation of surface , by removing old paint, proper cleaning , filling cavities with filler should applied internally and externally and reconnect the cable and all connected accessories complete all as specified and directed .
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
M/s Antony Kallarakkal
OM INFRA
V V BHARATH ENTERPRISES
ELSOL ENGINEERS
M/s.Rejoy Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .