Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹9.9 L+₹77,920 (8.52%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹13.4 L+₹4.3 L (46.9%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
6 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Clement Town
GE Clement Town MES Dehradun
REPAIR/ REPLACEMENT OF COOLING/ HEATING APPLIANCES AT NHO DEHRADUN UNDER GE CLEMENT TOWN, DEHRADUN
2023_MES_574166_1
GE/CLT/ Of 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class E Cat c(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹24,000
Yes
10 Mar 2023
10 Jan 2023
13 Feb 2023
10 Jan 2023
6 Feb 2023
23 Jan 2023
Amount
WATER COOLER S&F in repair sealed compressor unit of any make any type for water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, and fixing new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work etc and checking the leakage in the system and charging the gas R-22 / R-134 upto required pressure and tightening foundation nuts & bolts etc complete all as specified and directed.
S&F in repair potential relay box type for water cooler of upto 150/150 capacity complete all as specified and directed.
S&F in repair relay current type, for water cooler of upto 150/150 capacity complete all as specified and directed.
S&F in repair rubber hose pipe of 25mm bore with clips for outlet tray of water cooler approximately 1.5 Mtr long as per sample complete all as specified and directed.
S&F in repair Over load protector assembly complete all as specified and directed.
S&F in repair float valve assembly 15mm bore of PVC rigid type complete with ball, fixed to water cooler with threaded GI/PVC nipple washer, check nut etc complete all as specified & directed.
S&F in repair PVC connection rigid type 450mm long 15mm bore, with adopter at both ends complete all as specified and directed .
M&L for replacement of old condenser, fins type with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete all as specified and directed.
Supply and fixing in repair condenser fan motor of any size and for any cap water cooler complete all specified and directed.
Supply and fixing in repair push type self closing tap brass chromium plated for water cooler complete with all accessories washers , rubber packing etc complete all as specified and directed.
S&F in repair thermostate suitable for water coolers of any make and capacity complete all as specified and directed.
S&F in repair steel tray alongwith rubber gasket, waste coupler and GI elbow with check nut of 32 mm dia including necessary brazing work suitable for single tap water cooler of any capacity complete all as specified and directed.
All as per item No 12 here in before but for double tap water cooler complete all as specified and directed.
M&L for making the system leak proof and charging of gas R 22/ R-134 as required in water cooler of capacity 40/60 Ltr including replacement of drier and capillary tube and testing on load complete all as specified and directed.
M&L Dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc complete all as specified and directed.
Supply and fixing in repair PVC fan blade of suitable size for water cooler complete all as specified and directed.
M&L for repairing of the water cooler body front side by cutting the worn out stainless steel sheet and fixing new stainless steel sheet of 20 SWG cut in shape and fixed to frame with suitable fixing arrangement including welding/brazing complete all as specified & directed.
Supply and fixing runing capacitor 20 mfd capacity for water cooler complete all as specified and as directed.
Supply and fixing runing capacitor 10 mfd capacity for water cooler complete all as specified and as directed.
AIR CONDITIONERS Identifying and rectifying the minor defect/complaints of any type and nature such as rectification of faulty electric circuit, tightening of loose wiring & connection pertaining to all type of Air conditionar of any type and any capacity incl servicing, cleaning, and removing dust by air blower and washing with required solution complete all as specified and directed. Note:- (a) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the above quoted item. (b) Any part need to be replacement will be measured and paid seprately as per respective item of schedule.
S&F in repair sealed compressor unit for any make and any type of Air Conditioner, window/Split type, 1.5 ton capacity, by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, and fixing of new sealed compressor unit by connecting suction and discharge lines with gas welding/brazing work including checking the leakeage in the system and charging the gas R -22/ R-410 upto required pressure and tightening foundation nuts & bolts etc complete all as specified and directed.
All as per Item No 21 but for air conditioner window/split type, 2 ton capacity, complete all as specified and directed.
S&F in repair Electric blower Motor suitable for Air conditioner window type/split type 1.5 ton/02 ton capacity complete all as specified and directed.
S&F in repair Thermostat with regulating knob for AC window/split type, working on SP, 230V, AC complete all as specified and directed.
S&F in repair evaporating coil assembly with copper tube for window type AC complete all as specified and directed.
S&F in repair condensing coil assembly with copper tube for window type AC complete all as specified and directed.
S&F in repair copper pencil strainer of similar specification as that of old one complete all as specified and directed.
S&F in repair PVC blade for blower motor for window type AC/Split AC of Capcity 1.5 TR/ 02 TR complete all as specified and directed.
Supply & fixing in replacement of PCB circuit with remote control for air conditioner of any Make and capacity complete all as specified and directed.
S&F in repair starting capacitor 80/100 mfd, working voltage 275 volts, 50 Hz, AC suitable for window type room AC of capacity 1.5 TR as per existing make complete all as specified and directed.
All as per item No. 30 here in before but for 100/120 mfd complete all as specified and directed.
S&F in repair running capacitor 36 mfd 440 volts, AC 50 Hz, type SMRC suitable for room AC (Capacity 1.5 TR / 2.00 TR) complete all as specified and directed.
All as per item No.32 here in before but 45 mfd complete all as specified and directed.
S&F in repair Metal clad plug top, 3 pin , 20 amps, 230 volts complete all as specified and directed.
S&F in repair single pole and neutral enclosure with metal clad plug and socket 20 Amps and one single pole MCB 25 Amps complete all as specified and directed.
S&F in repair PVC front grill suitable for window type room AC of any make any type complete all as specified and directed.
S&F in repair three core, 2.5 Sqmm copper wire PVC insulated unsheathed,multistrand drawn through the PVC conduit/ PVC flexible pipe complete with suitable size of copper lugs etc complete all as specified and directed.
All as per item No-37 here in before but of size 4 Sqmm.
S&F in replacement MCB single pole, 240 volts,'C' series , 10 KA breaking capacity & connection with aluminium/copper lugs complete all as specified and directed of the following capacity :-
16 to 25 amps rating.
40 amps rating
S&F in replacement MCB, single pole & neutral, 240 volts, 'C' series, 10 KA breaking capacity & connection with aluminium/ copper lugs complete all as specified and directed for the following rating :-
All as per item No 40 but 32 amps rating.
All as per item No 40 but 40 amps rating.
M&L for Re-charging of refrigerant gas (R-22) for window type AC /split Type AC of Cap 1.5/2.0 after vaccuming dehydration, leak testing of the system as per standard practice, testing for proper cooling effects and satisfactory performance complete all as specified and as directed as per following type AC:-
Window AC/ Split AC 1.5 Ton capacity
Window AC/SplitAC 2 Ton capacity
Supply and fixing in repair relay, box type, for Air Conditioner window/split type of cap 1.5 Ton complete all as specified and directed.
Supply & fixing in replacement air filter for split type Air conditioner complete all as specified and directed.
Supply & fixing in replacement air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and directed.
M&L for replacement toggle switch for AC 1.5/2 ton cap complete all as specified & directed.
M&L for replacement sensor remote switch for AC 1.5/2 ton cap complete all as specified & directed.
Taking out the old/unserviceable heating/cooling unit from the machine of Air conditioner and S&F reversable unit (Hot and Cold) complete all as specified & directed.
S&F in replacement , copper pipe with insulation of size 1/2", 1/4" for Split AC of any capacity complete all as specified and directed.
All as item No 49 above but size 3/8", 5/8" complete all as specified and directed.
Supply and fix in repair stand set ( GI bracket of suitable size) for outdoor AC unit complete all as specified and directed.
M&L in repair for disconnecting, dismantling of existing split/ window type AC 1.5 /2 TR & refixing the same at new location including gas charging complete all as specified & directed.
M&L in repair for Re-charging of refrigerant gas (R-134A) for AC plant after vaccuming dehydration, leak testing of the system as per standard practice, testing for proper cooling effects and satisfactory performance complete all as specified and as directed as per following type AC:-
Supply and fix internal oil filter for compressor of 65 TR unit of central AC plant (Make Carrier,Model 30HXC) complete all as specified and directed.
M&L in repair of chiller water make up tank with insulating matrial complete all as specified and directed.
M&L in repair of cooling tower, cleaning, servicing with cleaning agent complete pipe lines, and FRP tank, greasing, servicing of cooling tower & traceout of water leakage, rectified the same etc complete all as specified and directed.
De-scaling of complete system of chilled water supply of 130 TR Plant and return line of all incl cleaning of strainers , using velin clean as descaling compound and removing all waste/foreign material (Make Carrier , model 30 HXC) complete all as specified and directed.
Taking proper shutdown unscrewing of strip heater finnel type 3 KW disconnecting electric connection and replacing by the new one strip heater by giving electric connection and screweing nut bolt properly and testing complete all as specified and directed.
M & L in repair 3 pole contactor 440 V ,coil voltage 220,25 A as per sample complete all as specified and directed.
M & L for 3 pole contactor 440 V ,coil voltage 220,32 A as per sample complete all as specified and directed.
M & L for 3 pole conntactor 440 V ,coil voltage 220,50 A as per sample complete all as specified and directed.
M & L for Over load relay 16A to 24 A as per sample complete all as specified and directed.
M & L for Over load relay 24 A to 32 A as per sample complete all as specified and directed.
M & L for timer delay relay 9 Sec to 30 Sec as per sample complete all as specified and directed.
Taking down of defective/burnt stablizer from various locations under GE Clement Town of capacity 1 to 5 KVA, single phase and Reinstalation of Volatage stablizer and rewinding of burnt transformer and testing complete all as specified and directed. (Spare Parts required will be measured and paid seperately as supply only item.)
S&F relay 24 Volts 250 Ohms
S&F condensor
S&F transistar
S&F circuit Card
S&F ciramic IC
S&F transformer winding
S&F mosfet
S&F volt meter as per existing
S&F indicator lamp (red/green)
S&F terminal strip
S&F push button
Taking down the geyser from its existing position and refixing the same after repair complete all as specified and directed. Note :-(Any parts replaced shall be measured & paid under respective item of Sch 'A'.)
S&F Geyser assembly of copper of 06/08/09 holes with nut, bolts, slud, washer for 25 ltr capacity complete all as specified & directed.
S&F Geyser assembly of copper of 06/08/09 holes with nut, bolts, slud, washer for 50 ltr capacity complete all as specified & directed.
S&F non return valve15mm dia for geyser complete all as specified and directed.
S&F inner shell for Geysers of 25/35 Ltr capacity made out of stainless steel complete all as specified and directed.
S&F inner shell (tank) for Geysers of 50 Ltr capacity made out of stainless steel complete all as specified and directed.
S&F Heating element 1.5/2.0 KW capacity, cup type,triangular/round/thread type for Geysers complete all as specified and directed.
S&F Heating element 3 or 4 KW capacity, thread type for solar water heater complete all as specified and directed.
S&F thermostat switch (adjustable type) for Geysers complete all as specified and directed.
Supply and install electric water heater storage type geyser (ISI marked) 5 star rated inner container with Stainless steel 1500 watt of capacity 25 Ltr complete grouting on wall with suitable size of nut & bolts washer as srequired at site complete all as specified and directed.
Taking out Solar heater rod carefully and Serviceing descaling & cleaning, of solar heater of 200/500 LPD capacity at site , with proper descaling solution & minor repair such as replacement rubber gasket of solar tubes,leakage if any to be rectified including cleaning of water tank and checking of hot water supply line complete all as specified and directed. Note :-(Any parts replaced shall be measured & paid under respective item of Sch 'A'.)
S&F solar rod ETC type 200/500 Ltrs cap solar water heater complete all as specified and directed.
S&F voltmeter 0-500 volts size 96mmx96mm complete all as specified and directed.
S&F ampere meter 0-500 volts size 96mmx96mm complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
Bedi Refrigeration Works
AIRCOM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .