Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹1.5 L
EMD Value
₹2,250
Closing Date
8 Nov 2023, 5:00 pmClosed
Chairman and Managing Director KPHCC
KERALA POLICE HOUSING AND CONSTRUCTION CORPORATION LTD CHANDRASEKHARAN NAIR STADIUM, PALAYAM, THIRUVANANTHAPURAM - 695033
Maintenance Works for Rectifying the Non- Conformities pointed out by the electrical inspectorate at Prison Head Quarters, Poojapura, Thiruvananthapuram (RE)
2023_KPHCC_618004_1
NIT No. 120/KPHCC/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Trivandrum
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
₹2,250
2 Dec 2023
1 Nov 2023
10 Nov 2023
1 Nov 2023
8 Nov 2023
1 Nov 2023
1 Nov 2023 - 8 Nov 2023
Amount
Electrical- Maintenance Works
od318111/2022_2023 : Supply and laying of chequered plates on the cable trenches including 2Coats of painting
od318112/2022_2023 : Service charge and transportation including cables and other accessories
od318113/2022_2023 : Supply and providing ABN make 7.5 capacitor duty contactor
od318114/2022_2023 : Supply and providing ABN make 16.7 capacitor duty contactor
od318115/2022_2023 : Supply and providing Shreem branded 6 stage APFC relay single CT
od318116/2022_2023 : Supply and providing of Shreem branded 2 kvar 440 V mpp heavy duty capacitor
od318117/2022_2023 : Suppy and providing Shreem branded 1 kvar 440 V mpp heavy duty capacitor
od318118/2022_2023 : Proper Identification and Numbering of earth pits with including resistance value test certificate
od318119/2022_2023 : Supply and fixing of Concrete Slabs on the earth pit Chamber
od318120/2022_2023 : Supply of Charcoals and Replacement of rusted nuts and bolt of the earth pits
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
od318121/2022_2023 : General Servicing of 200kVA USS- Switch of the power supply and open the panel board’s bus bar chamber, cable alley, and switch gears etc. Clean the inside with brush remove dust and web etc. clean inside and outside with air blower. Check all the connections and terminations crimping lugs, earthing etc. tight the connections and check for overheating carbonizing etc. Replace appropriate size of HRC Fuses in SFUs provide sleeves/insulation wherever necessary. Carbonizing to be cleaned with CTC etc. Replace switch gears and SFU/MCB where ever required. (SPARE parts & CTC will be supplied from the college). Check the megger values wherever required. Close the cambers once all the works are completed. Check OC/EF Replays, CTs, energy meters etc. in substation for proper working. Switch on power supply. Test one by one.
od318122/2022_2023 : Electrical installation testing and inspection report for insulation test, crimping of wires, jumbled wires, exposed DB, load test, Cable check, gland check, earthing point check, load testing, checking of cooling fan, interlocking of LT panel, etc.
Bidder Name
Powertech Electricals and Engineers
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_927317.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .