Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
17 Apr 2026, 4:00 pmClosed
University Engineer
Annual contract at unit rate for Anti termite treatment at various University buildings in the University campus for the year 2026-27.
290638
8/6 of 2025-26
Open
Miscellaneous Works
Vadodara
16 documents required · 14 mandatory · 2 optional
₹1,500
The Registrar, The M.S. University of Baroda
₹30,000
27 Mar 2026
27 Mar 2026
27 Mar 2026
17 Apr 2026
27 Mar 2026
Item.No Item Description Qty Rate Unit Amount
Carring out plinth treatment to post construction /
existing structure by spraying chemical solution for
termite control treatment including labour and material
consistment with I.S.I specification. Using Chlordene
and Chiorpurfiles 20 EC. As Per 6131_paret-II
1 Consentration Weight one percent is recommended 1.00 98.82 SQM
i.e one litre 20 EC chemical emulsion with 19 liter give
1 % concrentration inclusive of one litre chemical
emulsion appication at the rate of 5 Litre chemical /
Sqm of surface is recommended as per I.S
Carrying out timber treatment to all wood work
including drilling holes and spraying oil based
chemical solution on surface of timber work for termite
control including labor and material etc. complete.
Using Chlorpyriphos20 EC as per 6313 2013 Part III
(1% concentration by mass) is recommended one litre
2 chemical emulsion diluted with 19 liters of kerosene. 1.00 53.66 SQM
Total diluted concentration will be 20 liters inclusive of
1 liter chemical emulsion application in drilled holes
and 0.75 / Litre chemical per one Sqmt two coat on
wood surface not protected by paint or varnish.
Applying general insecticide pest control
treatment to floors, cupboards etc including
labour materials etc. complete. Using
Imidacloprid 30.5 SCas Per IS 6313 part -II(
3 (0.075% concentration by mass) is 1.00 46.95 SQM
recommended 10.5ml chemical diluted with
liters of water application 0.5 litre chemical
/Sqm of surface is recommended as per I.S.
Carrying out wall treatment for termite control
including spraying with chemical solution in oil base
including labour and material Using Chlorpyriphos
ECAs per IS 6313 part - II (1% concentration by mass)
is recommended i.e one litre chemical emulsion
4 diluted with 19 liter oil base. Total solution 1.00 28.54 SQM
will be 20 liters inclusive of one liter chemical
emulsion application at the rate of 7.5 litre chemical /
Sqm of surface is recommended as per I.S.
Item.No Item Description Qty Rate Unit Amount
Anti-Termite System:Providing and laying of
permanent piping technology anti-termite treatment
before flooring work by installing LLDP (Low linear
density polyethylene) tube of 8 mm O.D. & 6.4 mm
1.D. with inbuilt pressure compensation chip every
cm interval in the tube, having working pressure of
Kg/cm2 and release rate of 1.9 Itr/hour fixed by P-clips
and nails. The LLDP pipe shall be installed at the
entire periphery of the building and at internal network
of building at a depth of 20 to 200 mm under floor at
every 2 to 3 mtr. c/c distance (adjusted as per building
layout ) & Ends of loop pass through a PVC elbow of
minimum 32 mm ID at junction box of wall and floor
level, entering into a steel reinforced grooved flexible
5 pipe of minimum 22 mm ID leading into junction box 1.00 63.63 SQM
and the loops shall terminate in junction boxes & test
every junction during injecting chemicals for termite
control treatment. The anti termite chemical
Imidacloprid 30.5% SC mix as per IS-6313 (part III)
shall be injected by the pressure pump diluted with
water @ 10.5 ml/5 ltr of water at the rate of
Kg/sq.cm @ 5 Ltr/SMT. The contractor shall submit
approved line plan for piping system and junction
boxes dully approved by Engineer-in- Charge with
bond of 5 year warranty.(II)Anti Termite chemical
injected area (Chemical injecting incl. labour cost)
N.B.:- For any use of electrical machinery/tools during above works at any site by the contractor/
worker thye must obtain the N.O.C. from the Engineer- In -Charge, prior electrical conenction for
such work & arrangement for necessary extension of point and making good after completion of job
and also arrangement by contractor for electric power generator in case of non avaibility of electric
supply and fuel of one's own etc.complete as per site conditions.
1. The contractor shall have to give 5 years guarantee for the work on Rs.300/- stamp
2 The contractor shall have to attend/rectify all faults during guarntee period.
3 The contractor shall have to remove entire spots/ places on site and clean the area as per
4 The contrctor must possess licence issued from the Deptt. of Agriculture (Form - VIII).
Date: ______________ Sign. of Contractor with seal
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
All GR-merged (2).pdf
BuildingSpecificationBooklet.pdf
Tender notice No. 8.pdf
Form B -1 of T.No. 8-6.pdf
Schedul B- for ARC Antitermite 2026-27.pdf
Special Terms and Conditions T.No. 8-6.pdf
Technical-Bid for 8-6 of 2026-27.pdf
Download all tender documents and submit your bid