Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC lowest bidder |
Tender Value
Refer Docs
EMD Value
₹17,739
Closing Date
23 Jul 2024, 2:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
PWD ELECTRICAL SUB DIVISION EDAPPALLY
GENERAL-Renovation work and refurbishing of the Judges Lyceum of the High Court -Electrification-General Electrical Work
2024_PWD_679162_2
ESDE(ET)-41/AEE/2024-25
Open Tender
Electrical Works
Item Wise
120 days
ERNAKULAM
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,565
₹17,739
7 Oct 2024
18 Jul 2024
25 Jul 2024
18 Jul 2024
23 Jul 2024
18 Jul 2024
Amount
electrification
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
OD56847/2024-2025:Supply conveyance, installation, testing and commissioning of 15 W CEILING LIGHT LED round recess mounting down light efficiency not less than 100lumen /watt surge protection not less than 3Kv with replaceable drive etc complete in metal body/ batten directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS. (Make: HYBEC -HLR2668/ Equivalent)
OD56884/2024-2025:Supply conveyance, installation, testing and commissioning of 12 W CEILING LIGHT LED ROUND RECESS MOUNTING down light efficiency not less than 100lumen /watt surge protection not less than 3Kv with replaceable drive etc complete in metal body/ batten directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS. (Make: CRUISE 12W/ Equivalent)
OD56898/2024-2025:Supply conveyance, installation, testing and commissioning of 9 W CEILING LIGHT LED ROUND RECESS MOUNTING down light efficiency not less than 100lumen /watt surge protection not less than 3Kv with replaceable drive etc complete in metal body/ batten directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS. (Make: HYBEC-HLR-2656/ Equivalent)
OD56909/2024-2025:Supply conveyance, installation, testing and commissioning of 12 W CEILING LIGHT LED round SURFACE MOUNTING down light efficiency not less than 100lumen /watt surge protection not less than 3Kv with replaceable drive etc complete in metal body/ batten directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS. (Make: HYBEC -EB9423/ Equivalent)
OD56915/2024-2025:Supply conveyance, installation, testing and commissioning of 4 W CEILING LIGHT LED round SURFACE MOUNTING down light efficiency not less than 100lumen /watt surge protection not less than 3Kv with replaceable drive etc complete in metal body/ batten directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS. (Make: HYBEC -HLO-5301/ Equivalent)
OD56927/2024-2025:Supply conveyance, installation, testing and commissioning of 3 W PICTURE LIGHT LED round SURFACE MOUNTING focus light efficiency not less than 100lumen /watt surge protection not less than 3Kv with replaceable drive etc complete in metal body/ batten directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS. (Make: BELLA CASA-SLEDSLF113/ Equivalent)
OD56937/2024-2025:Supply conveyance, installation, testing and commissioning of 15 W LED FLOOR LAMP of height 154 cm efficiency not less than 100lumen /watt surge protection not less than 3Kv with replaceable drive etc including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS. (Make: BELLA CASA-PRINCE CHARMING PEDESTAL LAMP/ Equivalent).
OD56944/2024-2025:Supply conveyance, installation, testing and commissioning of 15 W LED HANGING LIGHTS efficiency not less than 100lumen /watt surge protection not less than 3Kv with replaceable drive etc including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS.( Make: BELLA CASA-THE SOUVENIR -A PENDANT LIGHT/ Equivalent)
OD56953/2024-2025:Supply, installation, testing and commissioning of COVE LIGHTS , LED Strip Light 15W in the existing cove including giving necessary connections suitable for 230V/240V single phase AC supply. (Make: SAMSON -EB-9081/ equivalent).
OD56971/2024-2025:Supply, installation, testing and commissioning of DRIVE 10 AMPS suitable for LED Strip light including giving necessary connections suitable for 230V/240V single phase AC supply.(Make: HYBEC- 10A D POWER/ Equivalent),
OD56972/2024-2025:Supply, installation, testing and commissioning of DRIVE 15 AMPS suitable for LED Strip light including giving necessary connections suitable for 230V/240V single phase AC supply.(Make: HYBEC- 15A D POWER/ Equivalent),
OD56977/2024-2025:Supply, installation, testing and commissioning of aluminium profile light 19 mm/25 mm with diffuser, LED strip of 15W per metre in the existing ceilings including giving necessary connections suitable for 230V/240V single phase AC supply. (Make: SAMSON -A001/ equivalent).
OD56980/2024-2025:Supply conveyance, installation, testing and commissioning the indoor 10W MIRROR LED LIGHT and giving connections as required (Make: PHILIPS-30973 / Equivalent.)
OD56986/2024-2025:Supply conveyance, installation, testing and commissioning the indoor 6W READING LED LIGHT and giving connections as required (Make: BELLA CASA-WALL SCONCE / Equivalent.)
OD56998/2024-2025:Supply & installation of light fittings on flat iron bracket <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp 4000K with box type fixture (Make: SAMSON-SLEDTF5041/ Equivalent).
OD57002/2024-2025:Supply conveyance, installation, testing and commissioning the indoor 20W WALL LED LIGHT and giving connections as required (Make: SAMSON-SLEDOFE010 / Equivalent.)
OD57007/2024-2025:Supply ,Conveyance, installation , testing and commissioning of 200 mm sweep Light Duty Exhaust fan in plastic body working on 230V single phase A/C and fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. (Mae: CROMPTON VENTILUS/EQUIVALENT).
OD56271/2024-2025:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 225(cubic meter/minute),37o RPM ,Copper winding suitable for 230V/240V single phase AC supply. Make: Crompton High Speed Jura /Equivalent
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.8:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
OD58589/2024-2025:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 10 sq. mm
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD56170/2024-2025:Supplying and fixing 40 A to 63 A, TP MCB (C curve), 10 kA breaking capacity, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD56171/2024-2025:Supply and providing 12x3mm brass nut and bolt etc. as required.
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.2.2:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)
OD56172/2024-2025:Charges for dismantling the existing points/fan/light fittings/switch boards/ plug sockets boards etc...., complete, making good the damages of walls and conveying the dismantled materials to section store.
OD73417/2024-2025:Supply and installation of 2 KVA , home inverter with 2 nos exide make 150 AH 6 EL tubular batteries including stand and including connections and make it in good working condition preferred make of UPS : hykon/numeric/zenrise or equivalent
Bidder Name
C.A.K. SOUND
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1059304.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .