Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹2 Cr+₹5,200 (0.03%)Rejected-AOC | ₹2 Cr+₹5,200 (0.03%) | L2 | Rejected-AOC Not Awarded |
| 3 | Not Admitted-Fee/PreQual/Technical AMGURI HOUSE NO 0 CITY TOWN CHIRANG P O AMGURI P S AMGURI DISTRICT CHIRANG PIN 783393 | CHIRANG | ASSAM | 783393 | - | - | Not Admitted-Fee/PreQual/Technical Others-Hardcopy not received |
| 4 | Rejected-Technical ASSAM AS | - | - | Rejected-Technical reject |
| 5 | Not Admitted-Fee/PreQual/Technical ASSAM AS | KAMRUP | ASSAM | 781030 | - | - | Not Admitted-Fee/PreQual/Technical Others-Hardcopy not received |
| Sl No | Description | Qty | Unit | Gwjwmsri Brahma L1 | EMANUEL BASUMATARY L2 |
|---|---|---|---|---|---|
| 1.00 | 1. COMMUNITY HALL :
2.8 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m
2.8.1 All kinds of soil. | 471.82 | Cum | 285 ₹1,34,469.56 Lowest | 286.85 ₹1,35,342.43 |
| 2.00 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating cach deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m | 471.82 | Cum | 250 ₹1,17,955.75 Lowest | 253.95 ₹1,19,819.45 |
| 3.00 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 419.49 | Cum | 2,160 ₹9,06,098.4 Lowest | 2,161.2 ₹9,06,601.79 |
| 4.00 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: | 41.89 | Cum | 6,833.4 ₹2,86,264.79 Lowest | 6,833.4 ₹2,86,264.79 Lowest |
| 5.00 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rainmed and consolidated and grouted with fine sand, including necessary excavation, ievelling & dressing & finishing the top smooth | 128.86 | Sqm | 681.65 ₹87,834.69 Lowest | 681.65 ₹87,834.69 Lowest |
| 6.00 | 5.1 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 142.13 | Cum | 8,364.2 ₹11,88,803.75 Lowest | 8,364.2 ₹11,88,803.75 Lowest |
| 7.00 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 19.8 | Cum | 10,185.05 ₹2,01,694.55 Lowest | 10,185.05 ₹2,01,694.55 Lowest |
| 8.00 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-i!I) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 23.45 | Cum | 10,719.3 ₹2,51,367.59 Lowest | 10,719.3 ₹2,51,367.59 Lowest |
| 9.00 | FORMWORK
5.9 Centering and shuttering including strutting, propping etc. and removal of form for
5.9.3 Suspended floors, roofs, landings, balconies and access platform. | 23.05 | Sqm | 766.55 ₹17,672.81 Lowest | 766.55 ₹17,672.81 Lowest |
| 10.00 | 5.9.1 Foundations, footings, bases of columns, etc. For mass concrete | 90.72 | Sqm | 307.95 ₹27,937.22 Lowest | 307.95 ₹27,937.22 Lowest |
Tender Value
₹2 Cr
EMD Value
₹4 L
Closing Date
23 Jul 2025, 1:00 pmClosed
the S. E, PWD, Kjr, Bldg Circle
O/o the S. E, PWD, Kjr, Bldg Circle
Infrastructure Development near Guru Dham established by Gurudev Kalicharan Brahma at Kazigaon, Debitola in Kokrajhar District under Untied Fund (State Specific Scheme) for the year 2024-25.
2025_BoTC_45295_1
No. TECH- 05/SE(B)/E-Tender/
Open Tender
Civil Works - Building
Item Rate
180 days
Kokrajhar
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,000
₹4 L
Yes
19 Aug 2025
2 Jul 2025
23 Jul 2025
2 Jul 2025
23 Jul 2025
2 Jul 2025
2 Jul 2025 - 23 Jul 2025
Amount
1. COMMUNITY HALL : 2.8 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m 2.8.1 All kinds of soil.
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating cach deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rainmed and consolidated and grouted with fine sand, including necessary excavation, ievelling & dressing & finishing the top smooth
5.1 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-i!I) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
FORMWORK 5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.3 Suspended floors, roofs, landings, balconies and access platform.
5.9.1 Foundations, footings, bases of columns, etc. For mass concrete
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
BRICKWORK 6.1 Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand).
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
DOORS AND WINDOWS 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for! separately).
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.52 Kiln seasoned and chemically treated hollock wood 9.5.2.1 35mm thick shutters
26.86 Providing and fixing factory made single exuuded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/min2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be lacceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 26.86.5 Frame size 65x100mm
26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900-N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/nim2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 26.87.2 35 mm thick.
21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, l.c. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): 21.1.1 For fixed portion 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron).
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 8.0mm thickness (weight not less than 20kg/sqm).
DOOR AND WINDOW FITTINGS 9.55 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. Complete: 9.55.2 100 x 58 x 1.9mm
9.63 Providing and fixing ISI marked oxidised MS tower bolt black finish (barrel type) with necessary screws etc. Complete 9.63.2 200 x 10 mm
9.103 Providing and fixing bright finished brass 100 min mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less han grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc. Complete.
Aluminium latch and handles
9.66 Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. Complete: 9.66.1 125mm
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.18.2 Fixed to openings /wooden frames with rawl plugs screws etc.
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Complete
12.1 Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horiontal/vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275gm/sqm.
12.52 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main. "I" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 min thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 min long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills. light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed! width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.52.2 GI Metal Celling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of Gl sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mi dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.4 size of tile 1000x1000mm
11.41.A.2 Glazed vitrified tiles matt/anti-skid finish of size 600x1200mm toilet area
11.47 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
13.1 12mm cement plaster of mix 13.1.1 1:4 (1 cement: 4 sand)
13.3.1 20mm cement plaster in mix 1:4
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. All walls and ceiling
PAINTING 13.48 Finishing with Deluxe Multi surface paint system for interiors and Exteriors using Pruner as per manufacturers specifications: Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including jone coat of Special primer applied @ 0.75 ltr /10 sqm
13.52 Painting on steel work Vertical bars MS square 12
16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (95.0m x 3.60m) 16.91.2 80mm thick cement concrete paver block of M-35 grade with approved colour, design and pattern.
2. UP-GRADATION AND RENOVATION OF QUARTER : DISMANTLING AND REPAIR WORKS FLOORING 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
7.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) upto plinth level with: 7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand).
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 size of tile 1000x1000mm
11.47 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). skirting
DOORS AND WINDOWS 9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.52 Kiln seasoned and chemically treated hollock wood. 9.5.2.1 35mm thick shutters.
DOOR AND WINDOW FITTINGS 9.55 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. Complete: 9.55.2 100 x 58 x 1.9mm
9.63 Providing and fixing ISI marked oxidised MS tower bolt black finish (barrel type) with necessary screws etc. Complete 9.63.2 200 x 10 mm
9.103 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc. Complete
9.66 Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. Complete: 9.66.1 125mm
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
12.52 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "I" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "I" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked jat middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.52.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece false ceiling
13.1 12mm cement plaster of mix 13.1.1 1:4 (1 cement: 4 sand)
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and Ismooth complete. All walls and ceiling
PAINTING 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 Sqm
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.
13.52 Painting on steel work
3. UP-GRADATION AND RENOVATION OF GUEST HOUSE : DISMANTLING AND REPAIR WORKS FLOORING 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
7.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) upto plinth level with: 7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand).
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 size of tile 1000x1000mm
11.41.A.3 Glazed vitrified tiles matt/anti-skid finish of size 600x1200mm toilet area
11.47 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
12.52 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "I" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "I" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked jat middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.52.2 GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece false ceiling
13.1 12mm cement plaster of mix 13.1.1 1:4 (1 cement: 4 sand)
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and Ismooth complete. All walls and ceiling
PAINTING 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 Sqm
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.
13.52 Painting on steel work
4. UP-GRADATION AND RENOVATION OF GAZEBO : DISMANTLING AND REPAIR WORKS 15.23 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.1 or thickness of tiles 10mm to 25mm
14.83 Hacking of CC flooring including cleaning for surface etc. Complete as per direction of the Engineer-in-Charge.
13.88 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete.
2.8 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m 2.8.1 All kinds of soil
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating cach deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m
2.25A Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including rainming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. Complete.
CEMENT CONCRETE WORKS 4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
RUBBLE MASONRY 7.6 Coursed rubble masonry (first sort) with hard stone in foundation and plinth with 7.6.1 Cement mortar 1:6 (1 cement : 6 coarse sand)
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 size of tile 1000x1000mm
11.47 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
11.2 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Medium shade pigment using.50% white cement 50% Grey cement
13.1 12mm cement plaster of mix 13.1.1 1:4 (1 cement: 4 sand)
13.3.1 20mm cement plaster in mix 1:4
13.23 Extra for plastering on circular work not exceeding 6m in radius 13.23.1 In two coats
13.27 Extra for lining out plaster to imitate stone or concrete blocks walling
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
PAINTING 13.48 Finishing with Deluxe Multi surface paint system for interiors and Exteriors using Pruner as per manufacturers specifications: 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including jone coat of Special primer applied @ 0.75 ltr /10 sqm
13.52 Painting on steel work
5. DISMANTLING WORKS FOR EXISTING DILAPIDATED COMMUNITY HALL : 15.2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-charge 15.2.2 Nominal concrete 1;4:8 or leaner mix (i/c equivalent mix)
15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
15.7 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 15.7.4 In cement mortar.
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead: 15.12.1 Of area 3 sqm metres and below
15.13 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead. 15.13.1 Of areas 3sqm and below
15.14 Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead: 15.14.1 Of sectional area 40 sq cm and above
15.28 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 15.28.1 GS Sheet
7. FURNITURE SUPPLY : Supply and installing premium quality chairs for auditorium. Brand : Supreme Colour : Black/Red Material : Plastic P. Size : 56 D x 56W x 81H cm Weight 4500 grams
11. AUDIO EQUIPMENT : Line Array speaker 1.1 Supply, Installation, Testing and Commissioning of Arrayable 2 Way 12" Constant Curvature Loudspeaker with Dendritic Waveguide for Touring. Frequency Response :- 65 Hz - 20 kHz ±3 dB, 53 Hz - 20 kHz -10 dB, Nominal Dispersion :- 100° H x 15° V @ -6 dB points, Directivity Factor (Q) :-31.4, Directivity Index (DI):- 15, Power Handling (IEC):- Passive: 600 W continuous, 2400 W peak (Make:- Turbosound/Tannoy/ Renkus Heinz/ JBL/ Bose)
Amplifier 2.1 Supply, Installation, Testing and Commissoning of 4-Channel Class TD Power Amplifier delivering 4 x 600 W @ 2 Ohms, 4 x 1700 W @ 4 Ohms, 4x 1200 W @ 8 ohms and 4 x 625 W @ 16 ohms, 1600 W into 70V/1G0V,2400 W @ 4 ohms bridged,3400 W @ 8 ohms bridged Make:- Labgruppen/ Powersoft/ Renkus Heinz/ JBL/ Bose).
Greenroom speaker 3.1 Supply, Installation, Testing and Commissoning of Mid-size All-weather, Surface Mount Loudspeaker With A Coaxially Mounted 19 mm (0.75 inch) Dome Tweeter; Frequency Range Of 65Hz to 30 kHz And Is Capable Of Handling 120 Watt Programme Material And Peaks up to 240 Watts. System Sensitivity (1 W @ 1 m)2 88 dB; Nominal Impedance 6 Ohms. (Make:- Turbosound/Tannoy/ Renkus Heinz/ JBL/ Bose).
4.1 Supply, Installation, Testing and Commissioning of Loudspeaker Management System (Make:- Behringer/ DBX/ Clearone/ Ahuja/ Bose/ JBL)
Mixing Console 5.1 Supply, Installation, Testing and Cominissioning of 32-channel Audio Mixing Console. Precision equalization circuitry, True 7-bus architecture, 2. stereo inputs 2 stereo returns, Channel direct outputs, 6 jaux sends, 4 of which are pre/post switchable, Integral universal voltage, switched-mode PSU for light weight Talkback facility, 100mm faders, +48 phantom power (Make:- Soundcraft/ Behringer/ Allen & Heath/ JBL/ Bose).
Microphones 6.1 Supply, Installation, Testing and Commissioning of Wireless Vocal Hand Held Microphone Set With Dynamic Cardioid Microphone Capsule; Enhanced Frequency Bank System With Up To 12 Compatible Frequencies; Frequency Response 80Hz - 180KHz; AF Sensitivity 2,5 mV/Pa. (Make:- Sennheiser/ Audio Technica/ Shure/ Behringer/ Bose/ JBL)
6.2 Supply, Installation, Testing and Commissoning of Wired, Dynamic Super-cardioid Microphone For Speech And Vocals With Noiseless On/Off Switch. (Make:- Sennheiser/ Audio Techrica/ Shure)
6.3 Supply, Installation, Testing and Commissioning of Long Microphone Stand (Make:- Ahuja/ MX/ Softline)
Cables & Connectors 7.1 Supply and Laying of High Flexible Speaker Cable For Power Amplifiers Up To 4000 Watts. 224 Strands O (Make:- Gotham/ Klotz/ Belden).
7.2 Supply and Laying of High flexible Speaker cable for power amplifiers upto minimum 500 Watt, Jacket - I (Make:- Gotham/ Klotz/ Belden)
7.3 Supply and Laying of Audio Signal Cable;Balanced microphone cable with single shield, high flexible, velve (Make:- Gotham/ Klotz/ Belden)
7.4 Supply and Installation of XLR connectors Male (Make:- Amphenol/ Neutrik/ Gotham)
7.5 Supply and Installation of XLR connectors Female (Make:- Amphenol/ Neutrik/ Gotham)
7.6 Supply and Installation of 1/8" (3.5mm) Balanced Phono Plug (Make:- Amphenol/ Neutrik/ Gotham)
7.7 Supply and Installation of 1/4"Unbalanced Phono Plug (Make:- Amphenol Neutrik/ Gotham)
7.8 Supply and Installation of Speakon connectors (Make:- Amphenol/ Neutrik/ Gotham).
8. ELECTRICAL WORKS : Community Hall 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group A
1.10.2 Group B
1.10.3 Group C
1.14 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
1.14.10 4 X 10 sq. mm +2 X 6 sq. mm earth wire
1.24 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.3 15/16 A switch
1.24.4 3 pin 5/6 A socket outlet
1.24.5 6 pin 15/16 A socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.2 3 Module (100mmX75mm)
1.27.4 6 Module (200mmX75mm)
1.27.6 12 Module (200mmX150mm)
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.13 100 A,30KA,FPMCCB
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 2.3.2 8 way, Double door
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 2.4.1 4 way (4+12), Double door
2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar formount-ing MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.1 4 way (4+12), Double door.
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. 2.10.1 Single pole
2.10.3 Double pole
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2 63 A
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
7.1 Laying of one.number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.2 Above 35 sq. mm and upto 95 sq. mm
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
MR-1 Supplying with including fitting fixing of ADORE LED PLUS 9 W/10 W. etc. as directed by the Deptt.
MR-2 Supplying including fitting fixing of 20 W three color CCT change LED batten which can change the color of batten from warm white to natural white to cool white with the help of a simple toggle switch. etc. as required and directed by the Deptt.
MR-3 Supplying with including fitting fixing of Aesthetically designed recessed mounted panel in a light weight plastic body available in LED 20 W etc. as required and directed by the Deptt.
MR-4 Supplying with fitting & fixing of 50 W IP 65 Street Lights/Campus light with best in class design & Robust heat sink along with class leading IP, IK & Surge protections for long lasting performance. etc. as required and as directed by the Department (Havells,Orient, Bajaj or equivalent make).
MR-5 Supplying with including fitting fixing of Metal Exhaust Fan (230 mm) Aeroclean LD GBD etc. as required and as directed by the Deptt.
MR-6 Design, fabrication & supply of Floor mounted compartmentalized dust and vermin proof power distribution Panel Board (L.T- 3 ph, 415 V, AC, 100 Amp) made of M.S. sheet of not less than 16 swg duly welded & Powder Coated with Grey colour to both in interior & exterior. All wiring for control & metering shall be done by multistranded PVC insulated Finolex make single core copper flexible cable of not less than 1.5 sq.mm. Size and will be properly harnessed and drawn neatly clamped for incoming & out going cables, 4 (Four) separately electrolytic grade aluminium busbar (3-Phase & Neutral) of 100 amps will be layed in separate chamber. All the outgoing cable of the MCCB/MCB up to cable alley connecter shall be connected by flat/round/flexible Copper cable etc. as required and as directed by the Deptt.
Quarter 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group A
1.10.3 Group C
1.14 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.24 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.4 3 pin 5/6 A socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.4 6 Module (200mmX75mm).
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator. 2.3.1 6 Way, Double door.
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. 2.10.1 Single pole
2.10.3 Double pole
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2 63 A
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
7.1 Laying of one.number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.2.1 Upto 35 sq. mm
19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
MR-1 Supplying with including fitting fixing of ADORE LED PLUS 9 W/10 W. etc. as directed by the Deptt.
MR-2 Supplying including fitting fixing of 20 W three color CCT change LED batten which can change the color of batten from warm white to natural white to cool white with the help of a simple toggle switch. etc. as required and directed by the Deptt.
MR-3 Supplying with including fitting fixing of Aesthetically designed recessed mounted panel in a light weight plastic body available in LED 20 W etc. as required and directed by the Deptt.
MR-7 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminum conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminum wire for single core up to 70 sq. mm, balance Aluminum strip, Glavanised wire for cables up to 2 x 10 sq. mm, 3 x 10 sq. mm, 4 x 6 sq. mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this Deptt.) Considering 100 Mtr. length). (i) 10.00 sq.mm 2 Core U.G. Cable
Gazebo 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group A
1.14 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.24 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.4 3 pin 5/6 A socket outlet
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.4 6 Module (200mmX75mm).
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator. 2.3.1 6 Way, Double door.
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. 2.10.1 Single pole
2.10.3 Double pole
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
7.1 Laying of one.number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.2.1 Upto 35 sq. mm
MR-2 Supplying including fitting fixing of 20 W three color CCT change LED batten which can change the color of batten from warm white to natural white to cool white with the help of a simple toggle switch. etc. as required and directed by the Deptt.
MR-7 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminum conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminum wire for single core up to 70 sq. mm, balance Aluminum strip, Glavanised wire for cables up to 2 x 10 sq. mm, 3 x 10 sq. mm, 4 x 6 sq. mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this Deptt.) Considering 100 Mtr. length). (i) 10.00 sq.mm 2 Core U.G. Cable
Guest House 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group A
1.10.2 Group B
1.10.3 Group C
1.14 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.24 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.3 15/16 A switch
1.24.4 3 pin 5/6 A socket outlet
1.24.5 6 pin 15/16 A socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.2 3 Module (100mmX75mm)
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 2.3.2 8 way, Double door
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 2.4.1 4 way (4+12), Double door
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. 2.10.1 Single pole
2.10.3 Double pole
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2 63 A
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
7.1 Laying of one.number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 Upto 35 sq. mm
12.34 Supplying and fixing of 32mm dia x 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
MR-1 Supplying with including fitting fixing of ADORE LED PLUS 9 W/10 W. etc. as directed by the Deptt.
MR-2 Supplying including fitting fixing of 20 W three color CCT change LED batten which can change the color of batten from warm white to natural white to cool white with the help of a simple toggle switch. etc. as required and directed by the Deptt.
MR-3 Supplying with including fitting fixing of Aesthetically designed recessed mounted panel in a light weight plastic body available in LED 20 W etc. as required and directed by the Deptt.
MR-4 Supplying with fitting & fixing of 50 W IP 65 Street Lights/Campus light with best in class design & Robust heat sink along with class leading IP, IK & Surge protections for long lasting performance. etc. as required and as directed by the Department (Havells,Orient, Bajaj or equivalent make).
MR-5 Supplying with including fitting fixing of Metal Exhaust Fan (230 mm) Aeroclean LD GBD etc. as required and as directed by the Deptt.
MR-7 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminum conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminum wire for single core up to 70 sq. mm, balance Aluminum strip, Glavanised wire for cables up to 2 x 10 sq. mm, 3 x 10 sq. mm, 4 x 6 sq. mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this Deptt.) Considering 100 Mtr. length). (ii) 10.00 sq.mm 2 Core U.G. Cable
UP-GRADATION OF 160 METRE L.T. LINE & ELECTRICAL LOAD 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
12.1 Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
12.10 Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
12.17 Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required.
12.18 Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nuts etc. as required.
MR-11 Supplying with errection of ACSR "WEASEL" Conductor as required and as directed by the Deptt. (Considering 100 Mtr. length).
MR-12 Supplying with fitting and fixing 3- phase Digital type Energy Mete tested with APDCL including Load Security, Meter security, Labour.charge and connection charge with all accessories materials as required complete as directed by the deptt. (For 7 KW Load).
MR-13 Payment to be made to APDCL for supervision charge .
20KVA D.G. set and 30 Watt Solar Street light 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
MR-8 Supplying, installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled complies with current CPCB-IV + emission norms with Standard Panel to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a (1) M.S. Fabricated base frame, (2) M.S. fuel tank of required capacity (3) Residual Silencer (Stack high shall be minimum 6.0 mtr. above the building where the gen set is installed (4) Satandar Control Panel (5) Suitable batteries with lead (6) First fill of lube oil (7) Acoustic enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification as per manufacturer (RANGE FROM 5 KVA TO 625 KVA, Kirloskar KOEL, Greaves, JAKSON or equivalent alternator. (25 KVA Liquid Cooled III - Phase with Std Panel Silent DG Generator Set).
MR-9 Supplying with fitting fixing of 63 A Change Over Switch (4 Pole) (Manual Range) ISI approved including all necessary connection etc. as required and as directed by the Department.
MR-7 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminum conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminum wire for single core up to 70 sq. mm, balance Aluminum strip, Glavanised wire for cables up to 2 x 10 sq. mm, 3 x 10 sq. mm, 4 x 6 sq. mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this Deptt) (ii) 25.00 sq.mm 3 1⁄2 Core U.G. Cable.
30 Watt Solar Street light MR-10 Supplying, Installation, Testing and Commissioning of 30 Watt Solar Two in One (Semi Integrated) LED Street light system with 6 Mtrs. GI Tubular Pole etc. as required and directed by the Deptt. (Make-Surya, Bajaj, Crompton, Havells or equivalent).
9. WATER SUPPLY AND SANITARY : 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and
17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
17.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : 17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever. 17.7.8 require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.1 Semi rigid pipe 17.28.1. 40 mm dia
17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 17.34 Providing and fixing toilet paper holder : 17.34.2 Vitreous china
17.35 Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia 17.35.2. Sand cast iron S&S pipe as per IS: 1729
17.60 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.60.1 100 mm inlet and 100 mm outlet 17.60.1.2 Sand cast iron S&S as per IS: 3989
17.61 Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 sand) 17.61.1 100mm dia
17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
18.15 Providing and fixing brass bib cock of approved quality 18.15.2 20 mm nominal bor
18.16 Providing and fixing brass stop cock of approved quality : 18.16.2 20 mm nominal bor
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.1 15 mm dia nominal outer dia pipes
18.9.2 20 mm dia nominal outer dia pipes
18.9.3 25 mm dia nominal outer dia pipes
18.9.4 32 mm dia nominal outer dia pipes
18.9.5 40 mm dia nominal outer dia pipes
18.9.6 50 mm dia nominal outer dia pipes
18.10 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall 18.10.1 15 mm dia nominal bore
18.13 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.13.1 20 to 40 mm nominal bore
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 18.17.1A 20 mm nominal bore
18.17.2 32 mm nominal bore
18.17.3 40 mm nominal bore
8.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.19.3 40 mm nominal bore 18.19.3. Horizontal
18.19.3 Vertical
18.21 Providing and fixing uplasticised PVC connection pipe with brass unions : 18.21.1 30 cm length 18.21.1 15 mm nominal bore
18.21.2 20 mm nominal bore
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
TUBE WELL : 18.42 Boring with 100 mm diameter casing pipe for hand pump /tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested : 18.42.1 Up to 6 metres depth
18.42.2 Beyond 6 m and up to 12 m depth
18.42.3 Beyond 12 m and up to Required depth
18.43 Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.
18.44 Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well.
18.45 Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories
18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 18.46.6 50 mm nominal bore
Reducing Socket, Valve etc
EMANUEL BASUMATARY (BID ID -272749)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .