Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC SHIMURALI DIST NADIA | NADIA | WEST BENGAL | L1 | Accepted-AOC AOC | |
| 2 | L2₹8.3 L+₹1,187 (0.14%)Rejected-Finance SIMURALI NADIA | PURBA BARDHAMAN | WEST BENGAL | 713502 | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹8.9 L+₹54,698 (6.58%)Rejected-Finance 150 276 K K RAM DAS ROAD NIMTA KOLKATA 700049 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700049 | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹14,300
Closing Date
12 Aug 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
District Hospital Campus Shaktinagar Krishnanagar
EI work for the Establishment of blood bank in the place of old ispolation ward at Santipur SGH Nadia
2024_WBPWD_727152_1
WBPWD/EE/NED/ NIQ/e-T/16/ (1st Call)24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
District Hospital Campus Shaktinagar Krishnanagar
Please refer Tender documents.
5 documents required · 5 mandatory
₹14,300
20 Mar 2025
2 Aug 2024
14 Aug 2024
2 Aug 2024
12 Aug 2024
2 Aug 2024
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average Run 9 Mtr [4(d)/ E-25 ]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works On Board [3 (a) / E- 24]
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (5A, plug point) [9 (a)/ E-18]
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (Power Plug point) [15/ E-19]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [9 (b)/ E-18]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (Computer Board) [ 12 / E-18]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/ E-19]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a) / E-17]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections [5(b) / E-17]
Supply & Fixing wooden Meter Board on wall by MS angle frame ( 65 mm x 65 mm ) incl. provision for fixing the meter with supply & fixing 250/415 Volt, 3 Nos. 125 Amp Fuse Base and Bridge incl. Neutral link incl. painting the wooden board as per direction of E.I.C. [ NS ]
Distribution wiring in 1.1 KV grade 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC of size 4 x 396/0.40(50 Sqmm) PVC single core stranded copper wire through PVC flexible pipe from meter to Cut-Out as per direction of E.I.C [ NS ]
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 125A. TPN , Make-L&T [D-3/4(a)]
32A, TPN , Make-L&T [D-3/4(a)] for autoclave machine
Supplying and fixing 125A, sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting. [D-5/5 ]
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts et 125A, FP Make- L&T [D-2/3(a)]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (2+8) Way , Enclosure(607711), Make- Legrand / Equvalent, [D-9/13]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 6 Way, Enclosure(607716), Make - Legrand [D-10/14]
4Way, Enclosure(607715), Make - Legrand [D-10/14]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Up to 160A 4 way(Up to 160A) Enclosure(607913), Make- Legrand [D-11/15]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ] 40 A DP [ 6 / D- 5 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS. [Make - Legrand / Schneider /L&T) as per direction of EIC.] 125 A Make- Legrand [10/D-8]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/ Siemens/ Crabtree/ L&T) as per direction of EIC] 6-32 A SP [ 7 / D- 6]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 as per GS 6 Way (vertical) [16/D-12]
6 Way (Horizontal) [16/D-12]
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
19 mm dia 3 mm thick polythene pipe without earth continuity wire.[E-2/3(a)]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. 3 x (1.5 sqmm) , [1(b) / E- 9 ] ( for 6 A Plug point ) as per direction of EIC
2x(2.5 sqmm) + 1x(1.5 sqmm) [ 1(s) / E-9 ] ( for16A Power Plug,CB) as per direction of EIC
2x(4 sqmm) + 1x (2.5 sqmm) [ 1(v) / E- 9 ] (For AC Point ] as per direction of EIC
2x (6 sqmm) + 1x (4 sqmm) [1(y) / E- 9 ] ( for HTPN to SPNDB) as per direction of EIC
4x(16 sqmm) + 2x (10 sqmm) [ 1(g1) / E- 9 ] for VTPNDB to HTPNDB) as per direction of EIC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
d) 6 sq mm [9(iii) / F-5]
e) 10 sq mm [9(iv) / F-5]
f) 16 sq mm [9(v) / F-5]
Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes[MakeGloster /KEI/Mescab/ Nicco/ Havells as approved by E.I.C] 4 Core 70 Sq. mm (from Meter to VTPNDB)
2 Core 10 Sq. mm [ For Compound light and Glow sign LED board]
4 core 16 sqmm [For autoclave connection)
Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 Core 10 Sq. mm [7(a)/F4 ]
4 core 16 sqmm [7(c)/F4 ]
4 Core 70 Sq. mm [7(c)/F4 ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 Core 10 Sq. mm [ 8(b-iii) /F5]
4 core 16 sqmm [ 8(b- xii) /F5]
4 Core 70 Sq. mm [ 8(b- xvii) /F5]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 4 Core 70 Sq. mm [ F-1/ 2(d) ]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting 4 core 16 sqmm [ F-1/ 2(b) ]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting 2 Core 10 Sq. mm [F-1/2(a)]
Fixing only single/twin fluorescent/LED light fitting in the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ 16/C-2 ]
Fixing only lamp [ 11/C-2]
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent make CG / Bajaj / Wipro/ Magik] incl. 1 no. 18W Master LED Tube (with 2 years warranty
Twin fittings [Philips make Cat No. TMC-501 P2xT-LED 22W P3242 or equivalent make CG / Bajaj / Wipro/ Magik] incl. 2 nos. 18W Master LED Tube(with 2 years warranty
Supply 9 watt LED Lamp. Make-Philips
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. [ E-6/ 18(a) ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [ 21 (a) / C-3 ]
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. [ 31/D-14 ]
Engraving the deptt. number with 10 mm lettering on the body as per GS. [ 24 (a) / C-3 ]
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS [ 26(a)/C-3 ]
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [29/C-4]
Fixing only exhaust fan after making holes in wall as per GS (12") [ 28(b)/C-4 ]
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) (12") [ 33/D-14 ]
Supply of ac ceiling fans of 1200mm sweep with burst-proof P2/S3 Capacitor complete with all accessories without regulator. BLDC 5 Star Ceiling fan without remote with 5 YEARS Warranty (Make - Crompton ENERGION Riviera/ Usha-Techno Air or equivalent model of Havells/CG/Orient as approved by E.I.C) 1200 mm Sweep
Supply of 450mm sweep wall bracket fan(high speed) with metal body & blades(Orient - Wall-II Tornado/Crompton WM SSTORM 2 or equivalent cat of CG/EPC/Cinni) with necessary wooden board on wall with nuts, bolts, washer etc.
Supply of heavy duty Exhaust fans of following size complete with all accessorie (Make -EPC ) as per direction of EIC. 12"( 300mm ) Speed 920 RPM
S & F mini pole on roof top by 80 mm dia., 2 Mtr. Long GI pipe medium quality (Make-Bansal/Jindal/Subham Pole) as per GS.(NS)
Supply & fixing 50mm Dia 1.5mtr long detachable type GI Single arm bracket suitable for the pole head.The arm brfacket shall be properly welded with 15mm thick stifner plate of pole sleeve for strengthening including properly fixing arfangement with the pole by bolt , nut, wahser as per direction of EIC.( NS)
For providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/ polythene pipe entry, for street light wiring, without Loop Box. [3(b-i)/H-1]
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting (a) 200 x 150 x 100mm [ I-2/ 16(a) ]
S&F of 250V 1-phase timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25A DPMCB (C-curve 10ka) and 1 no. 24 hr analog time switch and 1 no 22/25A 2pole power contactor complete with internal wiring with suitable size of copper wire including 1 no. toggle switch and 2 nos. LED indicator and earthing attachment as per direction of EIC. (For Compound light, Glowsign board) NS
Supply & Fixing of 240V, 72 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Make- Magik, cat no.- SPSL072C or equivalent model of Philips/Wipro/CG as approved by EIC) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. (with 5 years warranty)
Supplying and fixing 240V DP with fuse on L&N on Sheet steel Enclosure Main Switches on flat iron frame on wall ( Make: Havells/HPL/Anchor/Legrand/L&T,etc.) 32 A , DP [1(a)/D-1] (for Compound light)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4-Way [ 11 / D- 9 ] (for UPS connection)
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board as per GS [ 20( a )/D-13 ]
Dismantalling of the existing old electrical wiring from old existing panel etc.and also reconnection of existing cable to new panel as required. and also dismantling of the existing old wiring incl. existing fittings - fixtures etc.[NS]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS. [4(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming for Morrum Soil. [1(b)/G-1]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(d)/G-3]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No. 4 SWG [5(a)(i)/G-2 ]
LOKNATH ENGINEERING
S.B.ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .