| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | ₹18.2 L Quoted ₹19.1 L | L1 | Accepted-AOC Accepted for acceptance being lowest. |
| 2 | L2₹20.1 L+₹1.0 L (5.40%)Rejected-Finance | ₹20.1 L+₹1.0 L (5.40%) | L2 | Rejected-Finance Not L1. |
| 3 | L3₹20.2 L+₹1.1 L (5.83%)Rejected-Finance | ₹20.2 L+₹1.1 L (5.83%) | L3 | Rejected-Finance Not L1. |
| 4 | L4₹20.7 L+₹1.7 L (8.77%)Rejected-Finance | ₹20.7 L+₹1.7 L (8.77%) | L4 | Rejected-Finance Not L1. |
| 5 | L5₹21.4 L+₹2.3 L (12.3%)Rejected-Finance | ₹21.4 L+₹2.3 L (12.3%) | L5 | Rejected-Finance Not L1. |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
17 Sept 2021, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE OF INTERNAL ELECTRIFICATION ALONG WITH OTHER CONNECTED WORKS AT AF-II UNDER GE (AF) JAMNAGAR NO.2
2021_MES_468400_1
8312/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹37,000
Yes
2 Nov 2021
27 Aug 2021
18 Sept 2021
27 Aug 2021
17 Sept 2021
10 Sept 2021
Amount
Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point, socket point or power point including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces with distemper/white washing/colour washing as per existing complete all as specified and directed.
Taking down carefully by unscrewing from main switch boards / cut out boxes / MCB DBs / complete sealing the cable end and making good disturbed surface by walls etc complete all as specified and directed.
Taking down carefully by unscrewing from fitting and fixtures such as ceiling fittings, bulk head fittings, tube light fittings, street light, flood LED lights etc complete all as specified and directed.
Point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for modular type fitment including provision for fixing of modular flush boxes of suitable size complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 1.5sqmm as continous earth wire connected to common earth and earth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
(a) One Light point /Fan point controlled by one switch
(b) One 3 pin socket outlet 5Amps on the same board with other switches
(c) One 3 pin 5 Amp socket out let controlled by one switch on independent board
(d) One bell / Buzzer point controlled by one bell push 5 amp on the same board with other switches or independent
(e) One light point controlled by two way switch with cable 1.5 sqmm
Point wiring with PVC insulated and unsheathed multi stranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in existing concealed conduit with all accessories including providing sunk cast pressed steel terminal boxes of suitable size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated Bakelite sheet (HYLUM BRAND) top cover along with copper earth wire PVC insulated & unsheathed multi stranded (FRLS) copper conductor cable of size 1.5sqmm as continuous earth wire connected to common earth and earth dolly complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
One Light/Fan point controlled by one switch
One 3 pin socket outlet 5Amps on the same board with other switches
One 3 pin 5 Amp socket out let controlled by one 5 amp switch on independent board
One bell /Buzzer point controlled by one bell push 5 amp
One light point controlled by two 2-way switch with cable 1.5 sqmm
Point wiring for power point with PVC insulated and unsheathed multi stranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for modular type fitment including joint boxes, terminal boxes etc complete alongwith copper earth wire PVC insulated & unsheathed multi stranded(FRLS) copper conductor cable of size 2.5 sqmm as continuous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete as specified and directed. Note : Modular metal flush boxes will be measured & paid seperately.
Point wiring with PVC insulated and unsheathed multi stranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in existing concealed conduit with all accessories including providing sunk cast pressed steel terminal boxes of suitable size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated Bakelite sheet(HYLUM BRAND) top cover along with copper earth wire PVC insulated & unsheathed multi stranded(FRLS) copper conductor cable of size 2.5sqmm as continuous earth wire connected to common earth and erth dolly complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or froof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and as directed.
All as per item No 6 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continuous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
All as per item No 8 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
M & L for Switch piano flush type single pole, one way 5 Amp 230 V
M & L for Socket outlet 2 in 1, 3 pin, 5A
M & L for Switch piano flush type single pole, one way 15 Amp
M & L for Socket outlet 2 in 1, 3 pin, 15A
Supply and fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
M&L for Ceiling rose, 2 to 3 terminal PVC/ polucarbonate, isolated body type suitable for AC 230volts
M & L for switch Piano type 2 way 5 amp 230 volts
M & L for Bell push 5 Amp 230 volts
M & L for Bell AC 230 Volts, single pole
M & L for module cover plate with frame as per site requirement for following module Make : Legrand/C&S Electric/Havells
(a) 1 module
(b) 2 module
(c) 3 module
(d) 4 module
(e) 6 module
(f) 8 module
M & L for Modular metal Flush box as per site requirement.
(a) 1/2 module
(b) 3 module
(c) 4 module
(d) 6/8 module
M & L for modular switch 1 way 6 Amp 1 Module Make :- Legrand Arteor series Cat Part No 573400 / Kolors (Krest-white) / Crabtree or equivlant make mentioned in Appx 'B' to PS.
M & L for Modular switch 2 way 6A , 1 Module Make :- Legrand Arteor series Cat Part No 573402 / Kolors (Krest-white) / Crabtree or equivlant make mentioned in Appx 'B' to PS.
M & L for Modular Switch 1 way 16/20 Amp 1 Module Make :- Legrand Arteor series Cat Part No :-573410 / Kolors (Krest-white) / Crabtree or equivlant make mentioned in Appx 'B' to PS.
M &L for Modular Socket 6A 2/3 Pin universal 2 module Make :- Legrand Arteor series Cat Part No 573470 / Kolors (Krest -white) / Crabtree or equivlant make mentioned in Appx 'B' to PS.
M &L for Modular Socket 16A/ 6A 2/3 Pin combined 2 module Make :- Legrand Arteor series Cat Part No 573471 / Kolors (Krest -white) / Crabtreeor equivlant make mentioned in Appx 'B' to PS.
M &L for Modular fan step regulator 100 watt 2 module, Make :- Legrand Arteor series Cat Part No 573416 / Kolors (Krest -white) / Crabtree or equivlant make mentioned in Appx 'B' to PS.
M & L for Modular Bell push 6A1 way, 1 Module , Make :- Legrand Arteor series Cat Part No 573413 / Kolors (Krest -white) / Crabtree or equivlant make mentioned in Appx 'B' to PS.
Supply and fix in repair of Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete all as specified and directed.
Supply and fix in repair of Bell musical type AC 230 Volts, as directed including connecting complete all as specified and directed.
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx.) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed. Make -Wipro cat part No.LL20-221-XXX-65NE3 / Philips cat part no. BN O21C LED120S PSU CDL/NW GR(6500K) / HAVELLS or equivlant make mentioned in Appx 'B' to PS.
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 10 watt, channel housing & diffuser of length 600mm (approx) with all accessories, fixing arrangement internally pre-wired fixed in position & connecting complete all as specified and directed. Make -Wipro cat part No.LL20-111-XXX-65NE3 / Philips cat part no. BN O21LED 10S (6500K) / HAVELLS or equivlant make mentioned in Appx 'B' to PS.
Supply and fix in repair LED 12 W Porch light along with necessary fixing arragement complete all as specified and directed.
S & F bulkhead fitting 10watt made die cast aluminium housing with complete assembly and PC opal diffuser suitable for surface/wall mounted dust and water resistant complete all as specified and directed. Make: Wipro cat part no. LW07-141-XXX-57-XX / Havells / Philips or equivlant make mentioned in Appx 'B' to PS.
Taking down carefully (copper/aluminium) submain wiring complete of any type (batten/surface conduit or concealed) for socket point or power point complete with all fittings such as swiches sockets pendants etc complete and making good distrubed surface of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surface with distemper white washing / colour washing to match with the existing surface complete all as specified and directed.
M&L Sub main wiring using PVC insulated and unsheathed multistranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed of the following sizes of cables. .
(a) Using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire. Note : 2 runs of 4sqmm copper cable & 1 run of 4.0sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit
(b) Using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire. Note : 2runs of 6sqmm copper cable & 1 run of 6.0 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit
(c) Using two single core PVC insulated FRLS cable 10 sqmm copper conductor multi stranded and 10.0 sqmm copper conductor insulated cable using as earth wire. Note : 2 runs of 10sqmm copper cable & 1 run of 10 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit
(d) Using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire. Note : 2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit
M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection complete all as specified and directed. Make : Legrand Model: IP 54 IK 09 507641 Ekinox / L & T (Hager) / Schnieder (Multi-9) or equivlant make mentioned in Appx 'B' to PS.
M&L for distribution board (DB), double door type as per IEC 61439-3 made out of sheet metal enclosure (CRCA Sheet) dust and vermin proof MCB DB, TPN 4 way with 250 Amps rated copper busbar, 415 Volts with in built MCCB 160 Amps, 10KA 01 No 2neutral bar and 2 earth bar IP 54 protection cable ties for cable management (fully insulated busbar and shrouded neutral bars) reversible door for IP 43 & IP 54, flush mounting to wall, including provision of MCB SP 6 to 32 amp 10KA 12 nos complete all as specified and directed. Make : Legrand Model : No. 507750 Ekinox DPX 160MCCB IK-09 / L&T (Hager) / Schnieder (Multi-9) or equivlant make mentioned in Appx 'B' to PS.
M&L for MCB single pole & neutral 240 volt C curve 10 KA (32 to 63) Amps capacity IP 20 complete all as specified and directed.
M&L for MCB single pole,5 to 30 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed.
Earthing comple with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire mm as 4.0mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no.3 including earth pit in PCC concrete 1:2:4 type B-1,Cast iron cover 10 MM THICK HINGED to CI frame ,excavation and earth work in any type of soil and including protection pipe 15mm dia and water pipe GI tubing 20mm light grade with funnel and wire mesh connected to earthing test point complete all as specified and directed. Note:(i) Rates are inclusive of 7.5m long GI earth wire 4.0mm dia (ii) Rates of CI frame, RCC Pit cover, funnel and wire mesh included in the cost of item.
Supply and fix in repair 35W LED building security light luminaire complete with pressure die cast aluminium housing and primatic poly carbonate cover to ensure better unformity of light distribution fixed on bldg wall surface including provision of GI pipe bracket complete with clamp nuts bolts and washers and making good the disturbed surface of wall complete all as specified and directed. Make : Philips cat part No.BPR 050 LED 036 CW R1 MF PC S1 PSU GR / Wipro cat part No LR02-291-XXX-57-XX / HAVELLS or equivlant make mentioned in Appx 'B' to PS.
Supply and fix in repair LED power supply driver suitable for Primary : 220-240 VAC, 50/60Hz suiatble for 36watt LED bollard fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary : 220-240 VAC, 50/60Hz suiatble for 9/10watt LED bollard fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary : 220-240 VAC, 50/60Hz suiatble for 40watt post top fitting Secondary: constant current DC:300mA with thermal,overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and Fix Supply of Single Phase Two Wire Direct connected Meter Type SARAL,230/240 V (L-N), Rating 5-30 A, CL.1, 50 Hz ± 5%,IP 54,Protective class II, WITH Advanced anti-tamper capability– prevention, detection and deterrence,complete with protection cover Meter must comply following points :Standards IS 13779, IEC 62052-11, IEC 62053-21, IS 15959, DLMS Indian Companion Standard Dimensions (W x H x D) 95 x 130 x 60mm (approx.), Data storage : Midnight energy 35 days for 2 parameters, Load survey More than 150 days (30min. IP) upto 5 parameters,Events Up to 300 events, compartment wise History 12 billing periods. Communication: IEC 62056-21 physical port for local communication, Optional RS 232 port over micro USB for remote communication. Note: Rates are inclusive of polycarbonate Protection cover.
M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection complete all as specified and directed.
Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted fan by disconnecting electric connection for carrying out repairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carry out the repairs works, and connecting complete all as directed. Note:- Repairing such as rewinding, replacement of defective spare part, connecting wire, Over hauling and painting etc will be measured & paid separately under subsequent items.
M & L for rewinding of ceiling fan of any make by dismantling the ceiling fan, removing shaft ,bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing and reassembling. Providing three core copper cable PVC insulated multi stranded 0.5mm 30cm length for connection of fan from ceiling rose and testing of fan complete all as directed. Rewinding should be carried out for the following size of ceiling fan.
1200 mm sweep
1400 mm sweep
M & L for rewinding of exhaust fan motor of any make by dismantling the exhaust fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing, applying cotton tape and reassembling complete. Providing twin core copper cable 30cm length for connection and testing of fan complete all as specified and directed. Rewinding should be carried out for the following size of exhaust fan.
300mm sweep
220/200mm sweep
Supply and fix in repair ball bearing of any size suitable for ceiling fan 1200 mm / 1400 mm sweep complete all as specified and directed.
Supply and fix in repair Gun metal bush of any size suitable for ceiling fan of 1200 mm / 1400 mm sweep complete all as specified and directed.
Supply and fix in repair Gun metal bush of any size suitable for exhaust fan 300 / 200 mm sweep complete all as specified and directed.
Supply and fix in repair capacitor 2.5 MFD AC 230 Volt 50 HZ, for ceiling fans complete all as specified and directed.
Supply and fix in repair capacitor 4 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size complete all as specified and directed.
Supply and fix in repair bolt, nuts, washer and split pin for the down rod of ceiling fan complete all as specified and directed.
Supply and connection in repair PVC insulated, PVC sheathed three core copper conductor cable multi stranded of size 0.5 Sqmm for connecting of fan from ceiling rose complete all as specified and directed.
Material and labour painting of ceiling fan including blades by scrapping of old paint ,filling of cavities formed, preparation / cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality and writing MES / SM No with appropriate size letters using black paint complete all as specified and directed.
Material and labour painting of exhaust fan including blades by scrapping of old paint ,filling of cavities formed, preparation / cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality and writing MES /SM No with appropriate size letters using black paint complete all as specified and directed.
Assembling & fixing only ceiling fan 1200/1400 mm sweep complete with blades, down rod canopy etc including hanging in position and connecting including taking down old fan and deposited in Store yard of AGE E&M complete all as specified and directed.
Assembling & fixing only exhaust fan 300/200 mm sweep complete with blades, down rod canopy etc including hanging in position and connecting including taking down old fan and deposited in Store yard of AGE E&M complete all as specified and directed.
Periodical maintenance / servicing of solar water heater,flat plate collector type/ glass tube collector type, storage type with electrical backup of capacity 100 - 300 litres, as per manufacturer instruction comprising of the following works at different locations at GE (AF) Jamnagar. (a) Complete cleaning of solar system, removing of dirt dust etc. (b) Cleaning of heating surface glass with glass cleaning solution. (c) Opening of cold & hot water connection draining out deposited water removing of mud turbidity etc & cleaning with fresh water. (d) Checking of Non return valve, Electrical backup system & sacrificial anode & tighten the connection. (e) Checking of glass holding tube joint & rectification of leakage. (g) Replacement of unserviceable spare part will be carried out under respective item only. Note: (i) Unserviceable spares parts will be measured & paid separately as supply only. (ii) Work shall be executed through Authorised service technician of Tata Solar BP / Delta./Red ren (iii) Contractor shall submit the documentary evidence of Authorised service technician for the approval of GE before commencement of work.
Supply only solar glass tube suitable for glass tube collector of following size and cap
58 mm dia and 1800 mm long
48 mm dia and 1800 mm long
Supply and fix in repairs Hot water tank suitable for 100LPD tube collector
Taking out unserviceable/defective/damaged GI pipe 15mm bore steel water tubing and removing away all unserviceable pipe from site, complete all as specified and directed.
Taking out unserviceable/defective/damaged GI pipe 20mm bore steel water tubing and removing away all unserviceable pipe from site, complete all as specified and directed.
Taking out unserviceable/defective/damaged GI pipe 25mm bore steel water tubing and removing away all unserviceable pipe from site, complete all as specified and directed.
S&F GI tubing medium grade, ISI Marked conforming to IS 1239, 15mm bore with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed.
S&F GI tubing medium grade, ISI Marked conforming to IS 1239, 20mm bore with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed.
S&F GI tubing medium grade, ISI Marked conforming to IS 1239, 25mm bore with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed.
S&F in repairs Bronze gate valve class-1 for 15mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed complete all as specified and directed.
S&F in repairs Bronze gate valve class-1 for 20mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed complete all as specified and directed.
S&F in repairs Bronze gate valve class-1 for 25mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed complete all as specified and directed.
S&F in repairs 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered (ISI Marked) conforming to IS 12701: 1996 hoisted and fixed in position, including ball brass valve 20mm bore, fixed complete all as specified and directed.
M & L for taking out cold water tank installed for solar water heating system, dismantaling of incoming and outgoing pipe connection, removal of outgoing pipe line any size and type from cold water tank to solar heating system, dismantaling of gate valves in outgoing pipe and deposited to store yard of E/M section at AF-II complete all as specified and directed.
M & L for taking out and removal of hot water tank, solar water heating system ETC type,dismantaling of incoming and outgoing pipe connection ,dismantaling of pipe line any size and type from solar heating system to hot water tank and hot water tank to gate valve, dismantaling of gate valves in outgoing / incoming, certain other accessories connected to solar water heating system and deposited to store yard of E/M section at AF-II complete all as specified and as directed.
M & L for taking out steel structure associated with solar water heating system and deposited to store yard of E/M section at AF-II complete all as specified and directed.
M & L for reassembling of solar water heating sysyem ETC type any capacity complete with cold water tank, hot water tank, steel structure, outgoing pipe from cold water to solar system,pipe line from solar sysytem to hot water tank along gate valve, NRV and other accessories, pipe line from hot water tank till gate valve and certain other accessories connected to solar water heating system and deposited to store yard of E/M section at AF-II complete all as specified and directed. NOTE: Any material damage during dismantaling shall be replaced and paid under respective items.
suvidhiconstruction
BhagvanjiAssociates
Ramji K Nakum
Dara Paras.D
SIBS CONTRACTOR
M/S Badri Electicals
Hirachand Sunderji and co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .