Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-Finance | ₹4.5 L | L1 | Accepted-Finance Found in order and admitted |
| 2 | L2₹4.5 L+₹1,920 (0.43%)Accepted-Finance 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | ₹4.5 L+₹1,920 (0.43%) | L2 | Accepted-Finance Found in order and admitted |
| 3 | L3₹4.7 L+₹24,906 (5.57%)Accepted-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | ₹4.7 L+₹24,906 (5.57%) | L3 | Accepted-Finance Found in order and admitted |
| 4 | L4₹5.2 L+₹77,120 (17.3%)Accepted-Finance THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | ₹5.2 L+₹77,120 (17.3%) | L4 | Accepted-Finance Found in order and admitted |
| Sl No | Description | Qty | Unit | RASNA ENTERPRISES L1 | T.I.John and Sons L2 | ELAN ENGINEERS L3 | Green Ray Enterprises L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Install, testing and commissioing of Fire alarm control panel (Repeater panel) complying with BS EN 54 four loop panel of capacity from 99 detectors & 99 modules upto 200 detectors and mudules (per loop) including inter-connection/establishing communication with main FACP panel at INHS Navajivani. Note : i. The contractor has to establish communication with main FACP panel. ii. The contractor has to submit soft copy of programming alongwith final bill. | 1 | Each | 2,20,000 ₹2,20,000 | 2,00,000 ₹2,00,000 | 1,80,000 ₹1,80,000 Lowest | 1,90,000 ₹1,90,000 |
| 2.00 | Supply and fix fire retardant, flexible FRLS fire alarm cable 2 core x 1.5 sqmm, copper armoured cable including necessary clampings complete all as specified. | 400 | RM | 190 ₹76,000 | 160 ₹64,000 Lowest | 189 ₹75,600 | 160 ₹64,000 Lowest |
| 3.00 | Supply and fix Addressable electronic sounder cum strobe complete all as specified and directed | 1 | Each | 6,500 ₹6,500 Lowest | 6,500 ₹6,500 Lowest | 6,750 ₹6,750 | 7,000 ₹7,000 |
| 4.00 | Supply, install,testing and commissioning of detectors complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination with base with self built intelligence as per IS: 11360complete all as specified. | 50 | Job | 2,850 ₹1,42,500 Lowest | 3,500 ₹1,75,000 | 4,100 ₹2,05,000 | 5,200 ₹2,60,000 |
| 5.00M&L color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC conduit of suitable size, open suitable size modular flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting switches or sockets regulators etc including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly all as specified for the following:- Note i. Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. ii. Same size wire shall be used for phase, neutral and earth conductor. iii. The wiring shall be done strictly by following proper colour coding using red, blue, yellow for phase, black for neutral and green for earth leads. | |||||||
| 5.01 | a) 5 Amps socket point on independent board | 2 | Point | 500 ₹1,000 Lowest | 1,000 ₹2,000 | 1,650 ₹3,300 | 1,200 ₹2,400 |
| 6.00 | S&F in repair modular socket 6 Amps 2/3 pin 2 module. all as specified and directed by Engineer in charge.
Make Legrand/Crabtree | 2 | Each | 230 ₹460 | 350 ₹700 | 298 ₹596 | 190 ₹380 Lowest |
| 7.00 | S&F in repair modular switch one way 6 Amps 1 module, all as specified and directed by Engineer in charge.
Make Legrand/Crabtree | 2 | Each | 260 ₹520 | 350 ₹700 | 320 ₹640 | 160 ₹320 Lowest |
Tender Value
₹5.0 L
EMD Value
₹9,984
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2026_MES_774818_1
GE MAINT EZHIMALA 8890
Open Tender
Civil Works
Item Rate
120 days
Ezhimala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹9,984
Yes
30 Jul 2026
25 Jun 2026
30 Jul 2026
25 Jun 2026
24 Jul 2026
10 Jul 2026
25 Jun 2026 - 2 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Install, testing and commissioing of Fire alarm control panel (Repeater panel) complying with BS EN 54 four loop panel of capacity from 99 detectors & 99 modules upto 200 detectors and mudules (per loop) including inter-connection/establishing communication with main FACP panel at INHS Navajivani. Note : i. The contractor has to establish communication with main FACP panel. ii. The contractor has to submit soft copy of programming alongwith final bill. | 1 | Each | - | - |
| 2 | Supply and fix fire retardant, flexible FRLS fire alarm cable 2 core x 1.5 sqmm, copper armoured cable including necessary clampings complete all as specified. | 400 | RM | - | - |
| 3 | Supply and fix Addressable electronic sounder cum strobe complete all as specified and directed | 1 | Each | - | - |
| 4 | Supply, install,testing and commissioning of detectors complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination with base with self built intelligence as per IS: 11360complete all as specified. | 50 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.93 MB
TenderDocument8890.pdf
Tender Documents • 0.96 MB
BOQ_867617.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .