Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹32.7 L+₹87,596 (2.75%)Rejected-AOC | L2 | Rejected-AOC High Rate | |
| 3 | L3₹36.0 L+₹4.1 L (12.8%)Rejected-AOC | L3 | Rejected-AOC High Rate | |
| 4 | L4₹33.3 L+₹1.4 L (4.38%)Rejected-AOC 296 N 183 2 JOGEN GANGULY STREET MONIRAMPUR BARRACKPORE DIST 24 PARGANAS N KOLKATA 700 120 W B | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-AOC High Rate | |
| 5 | L5₹33.4 L+₹1.5 L (4.66%)Rejected-AOC | L5 | Rejected-AOC High Rate |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
11 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
MANNING AND OPERATION AND MISC REPAIRS TO INSTALLATIONS AT LOS DUM DUM UNDER GE (AF) BARRACKPORE
2021_MES_483339_1
8334/BKP/AF OF 2021-22
Open Tender
Civil Works
Item Rate
335 days
LOS DUM DUM
Pl refer tender documents
5 documents required · 5 mandatory
₹500
GE AF Barrackpore
₹60,000
Yes
24 Dec 2021
23 Oct 2021
13 Nov 2021
23 Oct 2021
11 Nov 2021
6 Nov 2021
60 days
Amount
Manning & operation of Los Dum Dum Main receiving station under 6 Wing Air Force Barrackpore one Electrician (Skilled) per shift for 3 shifts per day i.e 8 hours per shift including Sunday and holidays for operation of HT VCB"s and record the details of incoming and outgoing supply as directed by Engineer-in-charge Note The rate is deemed inclusive of following :- (i) Attending fuser-off calls and minor break downs as directed by Engineer-in-Charge (ii) Cutting bushes, cleaning installation maintaining higine thoroughly by cleaning inside and outside of installation all as specified and directed. (iii) All T&P, uniform will be issued/provided by the contractor. (iv) Insulation tape, fuse wire, hand gloves, torch with cell, cleaning material etc will be provided by contractor. List of equipment (a) Transformer 01Nos (b) VCB 01Nos (c) LT Panel 01 nos
All as per item No 1 above but one Helper Semi- Skilled per shift for 03 shift per day
Manning , operation, maintenance of the following equipment/machinery of Pump House at Air Force Los Dum Dum one FGM (Skilled) per shift for 2 shifts per day ie 8 hours per shift comprising with the following personnel per shift including Sunday and holidays :- List of equipments :-WATER SUPPLY (PUMP HOUSE) : (a) Submersible pump Qty-01 (b) iron removal plant-01 (c) Mono block pumpset – 01 No. (e) Chlorine dosing system – 01 No Note- (i) Uniform mail be issued/promoted by the contractor. All T&P like to in wrench, spanner & allowonces key, of required six, screw of remer, tester, cholorine test certificate, hardness test kit, Iron test kit with chemicals and required for testing, , PH meter etc all as directed. (ii) Maintaining of record log sheet for all equipment and operation on handly basis. After done register, break down register composing of periodical maintainance of pump, generator, LT Panel board, back wash of Iron removed plot as directed. A cum doiser, soda Ash doiser, cholorine dosing system. (iii) Inside and Outside cleaning of pump house will be done by the contractor. (iv) Attending Fuse and Cable and Minor break down like Repair/Replacement of NRV for cholorine dosing sysytem, Replacing of cholorine pipe, clear the blockage chlorine pipe line, sluz etc. Glandd producing of valve in cleaning packing material and all as directed by Engr-in-charge. (v) Cutting and brushes, cleaning installation, maintaining by line throughly by cleaning inside and outside and all as specified and directed. (vi) Outside of the Installation should be kept in 10 M surrounding should be cleaned through the contract period. (vii) Installation type, fuse wire, hand gloves, torch of capable to give light 100m with cell, cleaning material like broom stick gross outing tools, axe shade, tree trimming tool, all as specified and directed. (viii) First aid box with complete kit as per strandard medical specification. (ix) present of installation chort, showing the name of the character, CA No Name of the FGM Skilled, valve man, and their duty timing along mobile numbers all.
Disconnecting of electric cable from the panel board and taking out burnt submersible pumping set of capacity 10 hp to 20 hp by using chain pulley arrangement by dismantling 150 mm dia CI column pipe. Note : The rate are included for Transporation of pumping set from one place to another place for repair and return to pump house after repair all as specified and directed by Engg-in-charge .
Taking out the pump from the motor and opening of submersible pump for repair and replacement of following u/s parts including re-fixing of all the same and testing and commissioning complete all as directed. (a ) Replacement of head.
(b ) Replacement of gun metal bowl bush.
(c) Replacement of CI impeller.
(d ) Replacement of impeller bush.
(e ) Replacement of Discharge case bush.
(f ) Replacement of oil seal .
(g ) Replacement of shaft sleeve.
(h) Replacement of shaft nut.
(i ) Replacement of sand guard.
S&F in replacement stuffing box bearing of pump as per existing complete all as specified and directed
S&F in replacement stainless steel pump shaft coupling as per existing complete all as specified and directed
S&F in replacement stainless steel pump shaft of pump as per existing complete all as specified and directed.
Rewinding of submersible motor with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the following u/s parts of motor and testing and commissioning complete All as specified and directed by Enggr-in- charge. Note: Spares parts shall be measured and paid separately
(a ) Replacement of bearing bush upper.
(b ) Replacement of bearing bush lower.
(c) Replacement of balancing ring.
(d ) Replacement of jointing kit.
(e ) Replacement of oil seal .
(f) Replacement of gun metal rotor housing bush.
S&F in replacement stuffing box shaft with stud holes of motor as per existing complete all as specified and directed
S&F in replacement stainless steel pump shaft coupling of motor as per existing complete all as specified and directed.
S&F in replacement open type impeller made of CI as per existing complete all as specified and directed.
Lowering of the submersible pumping set by using the chain pulley arrangement with fixing of column pipe of size 150mm dia, including nut, bolts, washers, and rubber gasket in replacement. And tightening of submersible cable with pipe and connected of submersible cable from existing panel board. complete all as specified and directed by Engr-in-charge.
Repair , Servicing and rewinding of Altoc dozing motor of any size with super enameled copper wire including burnt winding and replacement of the parts as under which is unserviceable and refixing the same all as specified and directed by the Engr-in-charge. Note: Spares parts shall be measured and paid separately
(a) Pump tube
(b) injection check valve
(c) Duck bill
Oenix and associates
APOLLO TRADERS
M/S A. J. CONSTRUCTION
S. N. ENTERPRISE
M/S. B. N. CHATTERJEE
ONIEL SALES
ROY CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .