Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹24.4 L+₹2.3 L (10.2%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/s Charley Enterprises L2 | arshcontractor L1 |
|---|---|---|---|---|---|
| 1.00Carriage of the following material from Store Centre, Rampur to work site including loading & unloading. | |||||
| 1.01 | PCC Pole 11 Mtr Long | 165 | Nos | 1,000 ₹1,65,000 | 800 ₹1,32,000 Lowest |
| 1.02 | PCC Pole 8.5 Mtr Long | 106 | Nos | 700 ₹74,200 | 650 ₹68,900 Lowest |
| 1.03 | 11 KV V Type X Arm | 481 | Nos | 12 ₹5,772 Lowest | 20 ₹9,620 |
| 1.04 | 11 KV VCB O/G Feeder CTR 200/100/5A | 2 | Nos | 1,800 ₹3,600 Lowest | 2,000 ₹4,000 |
| 1.05 | 11 KV ST TH XLPE Cable jointing Kit | 4 | Nos | 10 ₹40 Lowest | 40 ₹160 |
| 1.06 | 11 KV Cable jointing outdoor 185sqmm | 16 | Nos | 10 ₹160 Lowest | 40 ₹640 |
| 1.07 | 11 KV 3x185sqmm XLPE Cable | 600 | Mtrs | 35 ₹21,000 Lowest | 50 ₹30,000 |
| 1.08 | ACSR Weasel Conductor (in mtr) | 10,500 | Mtrs | 2 ₹21,000 | 1 ₹10,500 Lowest |
| 1.09 | ACSR Rabbit Conductor (in mtr) | 22,350 | Mtrs | 2 ₹44,700 | 1 ₹22,350 Lowest |
Tender Value
₹24.4 L
EMD Value
₹25,000
Closing Date
18 Sept 2025, 11:00 amClosed
SE EDC RAMPUR
office of the SE EDC RAMPUR
15/2025-26/EDCR Construction of 11 KV line, bifurcation works and other electric works under Business Plan 2025-26 under jurisdiction of EDC, Rampur
2025_PVVNL_1069283_1
15/2025-26 (EDCR)
Open Tender
Electrical Works
Lump-sum
45 days
office of the SE EDC RAMPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
SE EDC RAMPUR
₹25,000
29 Oct 2025
28 Aug 2025
18 Sept 2025
28 Aug 2025
18 Sept 2025
28 Aug 2025
Amount
Carriage of the following material from Store Centre, Rampur to work site including loading & unloading.
PCC Pole 11 Mtr Long
PCC Pole 8.5 Mtr Long
11 KV V Type X Arm
11 KV VCB O/G Feeder CTR 200/100/5A
11 KV ST TH XLPE Cable jointing Kit
11 KV Cable jointing outdoor 185sqmm
11 KV 3x185sqmm XLPE Cable
ACSR Weasel Conductor (in mtr)
ACSR Rabbit Conductor (in mtr)
ACSR Dog (In Mtr)
Polymeric 11 KV Pin Insulator with pin
Disc fitting T & C with 45 KN
Disc insulator T & C 45 KN
Earthing Complete
Top Channel 100*50*2400mm
Dropper Channel 10*50*32mm
T-Off Channe, 100x50x2240mm
Stay set Complete
X bracing angel with nut and bolts
Bracing set 4.3X4.3 mtr
M.S Angle 65x65x6 mm (kg)
G.I. Wire 6 Swg (kg)
G.I wire 8 Swg
3- Phase D.O Fuse Set
ST Pole Rusted Scrap 25 no (Kg)(Recived Back Site to Store)
AI Scrap (in KG)(Recived Back Site to Store)
MS Scrap (in KG)(Recived Back Site to Store)
a) Single support Excavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support(pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing clamps made of MS flat of size 65x65xc6 mm with Nuts & Bolts, as per RESPO Norms.
11 Mtr long PCC Pole
8.5 Mtr long PCC Pole
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. a) Single support
11 Mtr long PCC Pole
8.5 Mtr long PCC Pole
b) Double Pole Structure Excavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support(pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing clamps made of MS flat of size 65x65xc6 mm with Nuts & Bolts, as per RESPO Norms.
11 Mtr long PCC Pole
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. b) Double Pole Structure
11 Mtr long PCC Pole
Grouting of Stay Rods(20x1800)mm including all work of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:8(cement, sand, 40mm brick ballast) including back filling of soil and proper ramming etc.
Fixing, tightening and nozelling of stay wire with stay rod with the pole of required tension by providing stay clamps.
Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 8SWG and earthing lugs.
fixing of 11 KV Pin Insulator with Pin as per RESPO Norms and as per direction of Supervising Engineer.
fixing of 11 KV Disc Insulator with Fitting as per RESPO Norms and as per direction of Supervising Engineer.
laying ,stringing and binding of ACSR Rabbit Conductor as per RESPO Norms and as per direction of Supervising Engineer.
laying ,stringing and binding of ACSR Weasel Conductor as per RESPO Norms and as per direction of Supervising Engineer.
laying ,stringing and binding of ACSR Dog Conductor as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of 11 KV 3*185 Sqmm XLPE Cable with the help of jointing kit as per RESPO Norms and as per direction of Supervising Engineer.
Laying ,stringing and binding of laying of 11 KV cable overhead as per RESPO Norms and as per direction of Supervising Engineer.
Providing and fixing of Bracing set 4.3x4.3 mtr Angle iron 65x65x6as per RESPO Norms and as per direction of Supervising Engineer.
Providing and fixing of Vacuum Interrupter as per RESPO Norms and as per direction of Supervising Engineer.
Maintenance of 11 KV VCB as per RESPO Norms and as per direction of Supervising Engineer.
Installing of 11 KV VCB O/G Feeder CTR 400/200/100/5A as per RESPO Norms and as per direction of Supervising Engineer.
Making of 11 KV Cable boxes mounted and O/g VCB(in job) as per RESPO Norms and as per direction of Supervising Engineer.
Installing/fixing of Bracing set 4.3X4.3 mtr as per RESPO Norms and as per direction of Supervising Engineer.
Installing and fixing of 3- Phase D.O Fuse Set as per RESPO Norms and as per direction of Supervising Engineer.
Dismentalling of ST Pole per RESPO Norms and as per direction of Supervising Engineer
Guarding of 11 KV Line (in Span) per RESPO Norms and as per direction of Supervising Engineer
Providing Natural cum earth wire G.I. 6 SWG and earthing per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing of HDPE Pipe 140 mm per RESPO Norms and as per direction of Supervising Engineer
Digging of trench and laying of Cable under Ground and proper filling by sand and brick as per RESPO Norms and as per direction of Supervising Engineer.
Providing and fixing of Aluminium jointing sleeves per RESPO Norms and as per direction of Supervising Engineer
Road restoration Charge Kattcha road (mtr) per RESPO Norms and as per direction of Supervising Engineer(complete material provide by contractor)
Road restoration Charge Pakka road (mtr) per RESPO Norms and as per direction of Supervising Engineer(complete material provide by contractor)
Providing and fixing Barbed wire per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Number plate with clamp per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Danger Board with clamp per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Stone Pad per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing PG Clamp RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Holding clamp RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Nut Bolt and washer all size RESPO Norms and as per direction of Supervising Engineer
Providing and fixing E Bracket RESPO Norms and as per direction of Supervising Engineer
Providing and fixing F Clamp RESPO Norms and as per direction of Supervising Engineer
Providing and fixing Clamp for X Arm with Nut & Bolt as per RESPO Norms and as per direction of Supervising Engineer
Providing and fixing G.I. Pipe 150 mm Dia (mtr) as per RESPO Norms and as per direction of Supervising Engineer
Dismentaling of old and used MS Scrap as RESPO Norms and as per direction of Supervising Engineer
Dismentaling of old and used AI Scrap as RESPO Norms and as per direction of Supervising Engineer
M/s Charley Enterprises (BID ID -5537566)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .