Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-Finance | ₹1.5 Cr | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹1.7 Cr+₹21.5 L (14.2%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | ₹1.7 Cr+₹21.5 L (14.2%) | L2 | Rejected-Finance Being Not L1 |
| 3 | L3₹1.8 Cr+₹25.9 L (17.1%)Rejected-Finance | ₹1.8 Cr+₹25.9 L (17.1%) | L3 | Rejected-Finance Being Not L1 |
| 4 | L4₹1.8 Cr+₹30.2 L (19.9%)Rejected-Finance | ₹1.8 Cr+₹30.2 L (19.9%) | L4 | Rejected-Finance Being Not L1 |
| 5 | L5₹1.8 Cr+₹30.8 L (20.3%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | ₹1.8 Cr+₹30.8 L (20.3%) | L5 | Rejected-Finance Being Not L1 |
| Sl No | Description | Qty | Unit | KR POWER INFRA INDIA PVT LTD. L7 | Power Dynamics L4 | ACS Technologies Limited L6 | MONITOR ENGINEERING WORKS L2 | DRK RAJU CONSTRUCTIONS L3 | Universal refrigeration and Engineering Company L5 | SPAAN Infratech L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00[SCHEDULE 'A' PART-I [E/M WORKS] | ||||||||||
| 1.01 | M&L for taking down old unserviceable power fencing 13 runs of GI wire on 1.2mtr height stand post on 4 mtr height wall including breakaway insulators, strain insulators, intermediate post removal of existing Powerfence complete all as specified and directed. | 4,600 | RM | 130 ₹5,98,000 | 165 ₹7,59,000 | 90 ₹4,14,000 | 103 ₹4,73,800 | 100 ₹4,60,000 | 140 ₹6,44,000 | 45 ₹2,07,000 Lowest |
| 1.02 | Supply, Installation, Testing & Commissioning of IP based Fence controller (dual Zone configuration) operating between 90V & 265V 50 Hz. The controller comprising of energizer & intelligent controller enclosed in weather proof panel IP66 of suitable size to accomodate 12V DC 42Ah Battery for backup with necessary input output module to connect controller over secure encrypted communication. The controller should comply to IEC603352-76 and IS-302-2-76 complete all as specified and as directed.
Specifications of Energizer:
a) No of Zones per Fence Controller: 2
b) Zone Configuration: HV-Earth
c) Fence Voltage: HV Range: minimum 6KV~8KV Low Feel: minimum 0.4KV~1KV
d) Communication with IFC: RS485 Encrypted (2Wire) at 1 Mbits/sec
e) Pulse Rate: 1 pulse every 1 Sec~1.5Sec (Mandatory; No pulse to repeat within 1 Sec)
f) Operating Voltage: 230V AC 50Hz
g) Internal Battery charger for 12V 42AH battery including trickle charge. | 12 | Each Job | 3,75,000 ₹45,00,000 | 1,84,444 ₹22,13,328 Lowest | 3,00,000 ₹36,00,000 | 2,86,533 ₹34,38,396 | 3,04,000 ₹36,48,000 | 1,94,000 ₹23,28,000 | 3,50,000 ₹42,00,000 |
| 1.03 | Supply & Installation of HT GI Wire of 2.5 mm with high conductivity, rust free with maximum DC resistance of 33 ohms per km. complete all as specified and directed. | 59,800 | RM | 25 ₹14,95,000 | 29 ₹17,34,200 | 35 ₹20,93,000 | 23 ₹13,75,400 | 25 ₹14,95,000 | 30 ₹17,94,000 | 9 ₹5,38,200 Lowest |
| 1.04 | Supply & Installation of Links with 2.5mm thickness complete all as specified and directed. | 4,030 | Each Job | 30 ₹1,20,900 | 37 ₹1,49,110 | 35 ₹1,41,050 | 33 ₹1,32,990 | 20 ₹80,600 | 35 ₹1,41,050 | 14.6 ₹58,838 Lowest |
| 1.05 | Supply & Installation of Joint Clamp complete all as specified and directed. | 2,015 | Each Job | 45 ₹90,675 | 47 ₹94,705 | 40 ₹80,600 | 33 ₹66,495 Lowest | 43 ₹86,645 | 45 ₹90,675 | 50 ₹1,00,750 |
| 1.06 | Supply & Installation of 1.2 metres 13 strands End post with 0.3m addl. Grouting length : Consisting of 40NB GI (B - Class) main post of 1.2 mtr height 1 no., with complete accessories for installation over Wall top.
a) Post shall be hot dip galvanized with min. 60 micron coating
b) Holdfast should be used for grouting
Note: (a) End post should have minimum of one support post ( seperate BOQ line item below ) of equal length to post, fixed diagonally in direction of the fence wire. | 310 | Each Job | 2,900 ₹8,99,000 | 4,350 ₹13,48,500 | 3,600 ₹11,16,000 | 3,563 ₹11,04,530 | 3,250 ₹10,07,500 | 4,000 ₹12,40,000 | 2,750 ₹8,52,500 Lowest |
| 1.07 | Supply & Installation of 1.2 metres 13 strands Corner End post with 0.3m addl. Grouting length: Consisting of 40NB GI (B - Class) main post of 1.2 mtr height 1 no., with complete accessories as per Specification for installation over Wall top a) Post shall be hot dip galvanized with min. 60 micron coating
b) Holdfast should be used for grouting
Note:(a) End post should have minimum of two support post of equal length to post, fixed diagonally in direction of the fence wire. | 31 | Each Job | 2,900 ₹89,900 Lowest | 4,350 ₹1,34,850 | 3,640 ₹1,12,840 | 3,013 ₹93,403 | 3,250 ₹1,00,750 | 4,000 ₹1,24,000 | 2,930 ₹90,830 |
| 1.08 | Supply & Installation of Support post 25 NB 1.2m with Addl. Grouting 0.3m with necessary C Clamp & Accessories for above end & corner post items
a) Post shall be hot dip galvanized with min. 60 micron coating
b) Holdfast should be used for grouting | 372 | Each Job | 1,100 ₹4,09,200 | 2,750 ₹10,23,000 | 1,680 ₹6,24,960 | 1,683 ₹6,26,076 | 1,250 ₹4,65,000 | 3,000 ₹11,16,000 | 932 ₹3,46,704 Lowest |
| 1.09 | Supply & Installation of Intermediate Post 1 no. 1.2m height with addl 0.3m for Grouting as per below specifications :
a) 2mm Profile rolled from Cold Rolled MS and hot dip galvanized to a min thickness of 60Microns
b) Holes equally spaced on profile not less than 91mm to hold Insulators / Hooks
c) Profile should be Pointed Top to prevent climbing
d) Holdfast should be used in case of grouting | 1,534 | Each Job | 1,250 ₹19,17,500 | 1,225 ₹18,79,150 | 1,600 ₹24,54,400 | 1,063 ₹16,30,642 Lowest | 1,400 ₹21,47,600 | 1,250 ₹19,17,500 | 1,150 ₹17,64,100 |
Tender Value
₹2.4 Cr
EMD Value
₹3.2 L
Closing Date
31 Mar 2025, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
SPECIAL REPAIRS OF POWER FENCING ON EXISTING PERIMETER WALL OF NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE (I) DM, VISAKHAPATNAM
2025_MES_699948_1
8150/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (I) DM, Visakhapatnam
₹3.2 L
Yes
22 Aug 2025
3 Mar 2025
2 Apr 2025
3 Mar 2025
31 Mar 2025
24 Mar 2025
Amount
[SCHEDULE 'A' PART-I [E/M WORKS]
M&L for taking down old unserviceable power fencing 13 runs of GI wire on 1.2mtr height stand post on 4 mtr height wall including breakaway insulators, strain insulators, intermediate post removal of existing Powerfence complete all as specified and directed.
Supply, Installation, Testing & Commissioning of IP based Fence controller (dual Zone configuration) operating between 90V & 265V 50 Hz. The controller comprising of energizer & intelligent controller enclosed in weather proof panel IP66 of suitable size to accomodate 12V DC 42Ah Battery for backup with necessary input output module to connect controller over secure encrypted communication. The controller should comply to IEC603352-76 and IS-302-2-76 complete all as specified and as directed. Specifications of Energizer: a) No of Zones per Fence Controller: 2 b) Zone Configuration: HV-Earth c) Fence Voltage: HV Range: minimum 6KV~8KV Low Feel: minimum 0.4KV~1KV d) Communication with IFC: RS485 Encrypted (2Wire) at 1 Mbits/sec e) Pulse Rate: 1 pulse every 1 Sec~1.5Sec (Mandatory; No pulse to repeat within 1 Sec) f) Operating Voltage: 230V AC 50Hz g) Internal Battery charger for 12V 42AH battery including trickle charge.
Supply & Installation of HT GI Wire of 2.5 mm with high conductivity, rust free with maximum DC resistance of 33 ohms per km. complete all as specified and directed.
Supply & Installation of Links with 2.5mm thickness complete all as specified and directed.
Supply & Installation of Joint Clamp complete all as specified and directed.
Supply & Installation of 1.2 metres 13 strands End post with 0.3m addl. Grouting length : Consisting of 40NB GI (B - Class) main post of 1.2 mtr height 1 no., with complete accessories for installation over Wall top. a) Post shall be hot dip galvanized with min. 60 micron coating b) Holdfast should be used for grouting Note: (a) End post should have minimum of one support post ( seperate BOQ line item below ) of equal length to post, fixed diagonally in direction of the fence wire.
Supply & Installation of 1.2 metres 13 strands Corner End post with 0.3m addl. Grouting length: Consisting of 40NB GI (B - Class) main post of 1.2 mtr height 1 no., with complete accessories as per Specification for installation over Wall top a) Post shall be hot dip galvanized with min. 60 micron coating b) Holdfast should be used for grouting Note:(a) End post should have minimum of two support post of equal length to post, fixed diagonally in direction of the fence wire.
Supply & Installation of Support post 25 NB 1.2m with Addl. Grouting 0.3m with necessary C Clamp & Accessories for above end & corner post items a) Post shall be hot dip galvanized with min. 60 micron coating b) Holdfast should be used for grouting
Supply & Installation of Intermediate Post 1 no. 1.2m height with addl 0.3m for Grouting as per below specifications : a) 2mm Profile rolled from Cold Rolled MS and hot dip galvanized to a min thickness of 60Microns b) Holes equally spaced on profile not less than 91mm to hold Insulators / Hooks c) Profile should be Pointed Top to prevent climbing d) Holdfast should be used in case of grouting
Supply & Installation of End Insulator for End post as per below specifications a) End insulator made of HDPE with UV Protection color black. b) End Insulator made of UV Stabilized glass filled nylon with maximum wire tension at 60kgs (long term load) and 200kgs (peak load), Operating temperature: -10⁰C to 60⁰C , Di-electrical Strength (Arcing Voltage) 15KV
Supply & Installation of Intermediate Insulator for post as per below specifications : a) End insulator made of HDPE with UV Protection color black. b) End Insulator made of UV Stabilized glass filled nylon with maximum wire tension at 60kgs (long term load) and 200kgs (peak load), Operating temperature: -10⁰C to 60⁰C , Di-electrical Strength (Arcing Voltage) 15KV all as specified and directed by Engr-in-charge.
Supply & Installation of End Hooks with 6.3mm thickness with minimum 50micron galvanized coating complete all as specified and directed.
Supply & Installation of Warning sign board (both side visible) made of PP with UV protection of size as specified by OEM in yellow color wlth Black Lettering. The warning messages shall be in Local Language and English. complete all as specified and directed.
M&L for earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level connected with GI strip 25 x 4mm by means of nuts, bolts check nuts, washers of galvanised iron or steel all as shown in electrical plate No:5 of SSR Part I connected to earth test point including excavation work in any strata precasted pcc chamber with precasted PCC cover slab with GI protection pipe 40 mm dia light gde upto 7.5 mtr/20 mm dia tunnel pipe med grade but all as specified and directed.
Supply & Installation of galvanised wire tightner with bréakage load of 200Kg with anti-unwind clip complete all as specified and directed. Note: The tensioning device should allow for the accurate tensioning of the fence wires to the required tension. It should only be possible to tension the fence wires by means of a special made tool which should Indicate the correct wire tension. complete all as specified and directed.
Supply & fixing of XLPE Insulated Cable 1C x 10 sq mm 11 KV grade (E) to connect the Fence Controller / energizer output connectors to the fence conductor wires of the perimeter fence 2.5MM GI Wire with HOPE outer Insulator Black and PP Inner Insulator complete all as specified and directed.
Supply & Installation of Lightning Diverter of size as specified by OEM & Adjustable spark gap for maximum protection with complete with necessary connecting up all as directed and directed.
Supply, installation testing & Commissioning of Fence live light indicator of size specified by OEM with the following specifications: a) fence is live- Flashing light should confirm the fence is working effectively. b) No Battery: Should use power from the fence. c) High Visibility. LED light should flash to indicate fence is working effectively. Should be easily visible during day and night. d) Should be Quick and Easy instaIIation: Simply clip onto fence wire and clamp the earth stake onto an earth wire or part of the earthed fence structure. e) Low Voltage Cut off: should not flash if the fence voltage is too low (approximately below 2 kv) f) Water and UV resistant.
Supply, installation testing & Commissioning of HV Gate & Cutout Switch to bypass the fence voltage over the standard 3-4m double swing gates while opening the gates all as specified and directed
Supply, installation testing & Commissioning of Guard tour system with guard check point at 12 locations (every Fence enclosures) with necessary smart card reader on enclosure with necessary EML , smart card credential with integration to Monitoring fence GUI Application capable of scaling to unlimited guard tour, tour points and reports with necessary hardware addition all as specified and directed
Supply, installation, testing & Commissioning of Workstation with Command Control Software comprising the following : (a) CPU Processor Intel Xeon processor E3-1230v5, Quad-Core, 8 MB cache, 3.4 GHZ, up to 3.8 GHZ with Intel Turbo Boost Technology, 16 GB DDR4 RAM,500GB SATA 7200 rpm 6Gb/s 3.5" or 2.5" HDD,DVDRW ,windows-10. (with Monitor (Size 55 inch) , keyboard, Mouse). Workstation display resolution shall be a minimum of 720P. 1080P shall also be supported.The operating system used by workstations shall be Microsoft Windows 10 or 8,1 Pro (64 bit). Workstations shall support multi-monitor operation, allowing an operator to set up one or more monitors for each workstation.
(b) Command Centre Software consisting of GUI interface with necessary license for 23 fence monitoring zones & one Workstation license. The communication with controller should be atleast 256 bit AES encrypted. User should able see the health of fence, zone voltage, logs, status of each device on the network, Switch off / on the fence. Also should provide mobile client from which fence voltage and control should be available. Software shall support multiple guard tours between check points.There shall be no imposed limit on the number of guard tours that can be configured. Check points shall be card readers, inputs, or outputs. All the database of alarms, Events, Guard tours, fence voltage report etc should be stored in a single database and should be in one software of OEM all as specified and directed by Engr-in-charge
(c) Supply and Fixing of Digital Volt meter it shall be of portable type with digital display either LCD/LED.Displays 100 volt increments up to 10kV then 1000 volt increments from 10kV to 20kV.Tough polycarbonate case material
Supply & Installation Ethernet Switch with 8x10/100TX Layer 2 Managed Switch with 2 SFP ports and 2 Single mode SFP transceiver all as specified and directed.
Supply, Installation, Testing & Commisioning of 2 KVA UPS system with 06 Nos. 12 V, 42 AH SMF batteries all as specified and directed.
Supply and Laying of 6 Core armoured OFC cable wlth accessories all as specified and directed
Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 6 sq.mm 3 core complete all as specified and directed.
Supply, installation testing & Commissioning of Power Fence Outdoor Hooter complete all as specified and directed.
Supply, Installation, Testing & Commisioning of Integration between the Alarm Monitored Pulse Fence and CCTV Camera shall be achieved by means of hard wire Integration between the fence controller and CCTV Camera all as specified and directed. Note :- All accessories required for integration of power fence with existing CCTV camera are inclusive of the quoted rate.
Excavation in trenches not exc 1.5M wide and not exc 1M in depth and getting out in soft loose soil for cable work or from above cable duct all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick all as specified and directed.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed.
M & L for 40 mm bore GI pipe tubes light grade for cable protection supporting with all fixing accessories (clamp, nuts, bolt and washer etc ) complete all as specified and as directed
Supply and fixing HDPE double wall pipe corugated pipe of size 40 mm dia for cable protection laid in trenches in lieu of sand/brick protection all as specified and directed.
Supply and fix test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screw all as specified and directed.
[SCHEDULE 'A' PART-II [B/R WORKS]
Demolition of cement concrete of any description and in any position and removing the material away from dockyard premises complete all as specified and directed.
M&L for cement concrete type B2 (1:2:4) ussing 40 mm garded stone aggregate as filling and mass concrete including necessary formwork complete all as specified and directed.
Taking down cement plaster on walls/Ceiling etc including racking out joints hacking for key scrubbing down with water and removing the debries away from the Dockyard premises all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces and finishing the surface even and smooth with out using extra cement all as specified and directed.
M&L for preparation of new plastered surfaces of walls and apply two coat of exterior weather proof emulsion over a coat of Alkaline resistance primer primer complete all as specified and directed.
MONITOR ENGINEERING WORKS (BID ID -3274362)
DRK RAJU CONSTRUCTIONS (BID ID -3274367)
Power Dynamics (BID ID -3273425)
Universal refrigeration and Engineering Company (BID ID -3274375)
ACS Technologies Limited (BID ID -3274079)
KR POWER INFRA INDIA PVT LTD. (BID ID -3273114)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .