Chief Executive Officer,Technokpark
Park Centre, Technopark main campus, Kazhakuttam, Karyavattom P.O, Trivandrum
Supply and Fixing of Passive Fire Protection System at Technopark Phase III IT Building, Thiruvananthapuram.
2020_ETPK_378597_1
ETPK/PH-III/2020-21/AT-86-R
Open Tender
Miscellaneous Works
Item Rate
90 days
Technopark Phase III IT Building (SEZ), Trivandrum
Refer Tender documents
4 documents required · 4 mandatory
₹2,950
online
₹50,000
6 Oct 2020
20 Aug 2020
8 Sept 2020
20 Aug 2020
7 Sept 2020
21 Aug 2020
Amount
Fire stop Mortar
Supply & Fixing of Fire stop mortar system with minimum 2 hours fire rating when tested in accordance IS 12458 for horizontal openings in floors or slabs after passing service lines like Cable trays, Bus Bars or Metal pipes etc. The system shall have a load bearing capacity min 200kg/sq.mtr by assembling using 8mm or10mm rebar coated with red oxide paint fixed with epoxy resin injection chemical onto the RCC member, also the manufacturer to conduct a pullout test for a rebar after instalation. All the cutouts has to documented report to be submitted by the contractor. The complete execution has to be done by manufacturer approved speciality contractor. Make : Hilti / Fischer
Fire sealent & wraps for non mettalic pipes Provide intumescent firestop wraps for plastic pipes passing through fire rated walls and floors made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation and integrity when subject to the test conditions of UL 1479 standards. The product shall also be age tested as per DafStb guidelines. The product should be FM and UL approved. The product should be should be tested as per DIN 52210 for sound insulation of approx.60 dB. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 3.1 g/l as per LEED 2009. The product shall bear the UL and FM approval logo on the packing where applicable. Make : Hilti / Fischer
Plastic Pipe diameter of 1'' (Firestop Sealant)
Plastic Pipe diameter of 1.5"(Firestop Sealant)
Plastic Pipe diameter of 2'' (Firestop Sealant)
Plastic Pipe diameter of 2.5'' (Firestop Wrap),
Plastic Pipe diameter of 3'' (Firestop Wrap)
Plastic Pipe diameter of 4'' (Firestop Wrap)
Metal pipe diameter of 2" (Firestop Sealant)
Metal pipe diameter of 6" (Firestop Wrap)
DYNAMIC SYSTEMS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .