| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC AIR FORCE ROAD NEAR BRIDGE OPP KHETIWADI RAJIV NAGAR JAMNAGAR 361002 | JAMNAGAR | JAMNAGAR | GUJARAT | 361002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹53.8 L+₹1.4 L (2.65%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹55.1 L+₹2.6 L (5.05%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹56.3 L+₹3.9 L (7.51%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹57.3 L+₹4.8 L (9.24%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
20 Jul 2022, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS VALSURA JAMNAGAR 361150
PROVN OF DEFICIENT IRONING ROOM DEMOLITION OF RCC OVER HEAD TANK NO 4 AND SPECIAL REPAIRS TO CERTAIN OFFRS ACCN AT INS VALSURA JAMNAGAR
2022_MES_506840_3
8571
Open Tender
Civil Works - Others
Item Rate
180 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹98,000
Yes
14 Feb 2023
25 Jun 2022
22 Jul 2022
25 Jun 2022
20 Jul 2022
27 Jun 2022
25 Jun 2022 - 26 Jun 2022
Amount
Dismantling / taking down carefully CI / GI inlet / out let washout / over flow water pipe lines including fittings , stair case rallings , complete electrical fittings , including dismantling of chainlink fencing along with post at front & left hand side of OHT and stacking at site where directed by EIC and finally demolition of complete (i.e dome slab , walls , cols , beams , landing slabs etc) vintage RCC framed structure OHT tank 25000 gallons capacity on 21 Mts high staging & removal of demolished debris complete out side MD land to the entire staisfaction of Engineer-in-charge .(Note : (i) The demolition /dismantling is being executed at Valsura , the area being restricted hence blasting is stictly prohibted . (ii) Scafloding as per relevant safety IS norms shall be followed & the same to be got approved be Engineer-in-charge before commencement of demolition / dismantling work. (ii) The demolition work should be carried out in presence of qualified safety supervisior to avoid any sort of accident/ incident due to negligence of trades man. All tradesman involved in the task should pocesses valid insurance & the same to be submitted to Engineer-in-charge for verification & record. (iii) All necessary saftey precautionery equipments as per IS such as hand gloves , safety belt , head helment etc shall be arranged by the contractor (iv) During demolition / dismantling of OHT if any adjacant Bldg / structure is damaged due to negligence of working people the same to be made good as per its orignal specifiaction to entire satifaction of Engineer-in-charge without any extra cost to Govt. (v) The quoted rate aganist various items in BOQ is deemed to be inclusive of the same & no extra shall be admissible. Contractor must visit the site of demolition/ dismantling prior quoting his bid to have a better assessement.
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliated demolition) and removal of entire debris as ordered outside MD land complete all as directed.
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as directed.
Excavation in trenches, not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole, laying of cables, stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in soft / loose soil.
Excavation in trenches, not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole, laying of cables, stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in soft disintegrated rock complete all as specified..
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance exceeding 1.50 km but not exceeding 5.00 km and depositing where directed .at a level complete all as directed.
Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
M&L for Moorum/ red bajri filling under floors or in foundation etc including spreading levelling, watering and well ramming in layers not exc. 15 cm thick complete all as specified and directed. (Note i): Moorum brought from out side MD land . ii) Measurements shall be taken after compaction).
M&L broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
M&L for PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling, mass concrete complete all as specified and directed
M&L providing PCC coping, kerb, apex stones etc type B1 1:2:4 (20mm graded aggregate) all around the interlocking paver block area all as specified and as directed.
M&L pre-cast PCC 1:3:6 type C1 (using 20 mm graded granite aggregate) as in block masonry with factory made solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified.
M&L for RCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in chajja, roof projection etc in any description up to 10 Mts in height in paches including necessary form work complete all as directed. (Note : Qutoed rate is deemed to be inclusive of form work, scaffolding, safety belt etc ).
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, base of columns etc and the like complete. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) square or rectungular as in Columns, pillars, piers, posts and struts and the like complete. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in beams, cantilevers, bressummers lintels over 1.5m span complete all as directed.. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in chajja complete all as directed. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 ( using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, canopies, deck slab etc complete all as directed. Note: Reinforcement shall be measured and paid separately.
Supply only Integral Water Proofing Compound (ISI Marked) of Make: CICO, Acco Proof, Impermo, Aqua flex as approved.
Formwork to chullah hoods, chajjas, troughs and similar items including edges, flat rough finished surface all as specified.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or batter, flat rough finished surface all as specified.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions in square, rectangular on polygonal, rough finished surface all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat rough finished surface all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping), flat rough finished surface all as specified.
S&F Second class hard wood factory made kiln - seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as directed.
S&F 35 mm thick flush shutter with solid core construction with block board core and plywood face panels, commercial type on both sides including exposed surfaces finished with external teak wood lipping, 6mm thick fixed with nails and both side 0.90mm thick Decorative laminate type 1 of surface finish, colour and pattern and approved, fixed with approved adhesive as per manufacture's instructions complete all as directed.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as directed.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutter, side hung type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing anodized aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos.), suitable handle (1 No.) etc. complete all as directed. Note: Glass shall be measured and paid seperately.
S&F 150 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F 150 mm size aluminium alloy handles (ISI Marked) fabricated type anodised and fixed.
S&F 250 mm long aluminium alloy, anodised sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S&F GI chicken wire mesh cut to size made to shape as ordered including fixed to walls for receiving a plaster.(Note : Weight of GI chicken wire mesh shall not be less than 0.50Kg/ Sqm)
M&L mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S & F 10 mm dia and over CRS bars cut to length bent to shape required cranking including bending , hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No. 41 here-in-above but 6 to 8mm dia bar - do -
All as per item No. 41 here- in – above but 5 mm dia and over upto 10 mm dia as in stirrups
S & F 10 mm dia and over TMT bars cut to length bent to shape required cranking including bending , hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Material and labour for prepration of surface over roof slab and cleaning of surface with wire brushes and water removing of unsolvent materials and depositing of the same as directed at a distance not exceeding 50m and provide 15 mm thick screed bed/ bedding layer in CM 1:3 mixed with Water Proofing Compound (WPC) as per manufacturer instructions, including finishing the surface fair and even on RCC roof/ parapet once bedding layer of concrete is completely dried and apply oil bound bituminous primer @ 0.30 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure as directed and finally finished the top surface with two coats of thermal resistant paint complete all as specified and as directed. Note: (i) The quoted rate is deemed to be inclusive preparation of roof surface complete, 15 mm thick 1:3 screed & complete APP treatment. (ii) WPC will be paid seperately (iii) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT (iv) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M & L for 75 mm thick plain cement conctere 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection/ path etc. finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed granite stone aggregate) as in sub base, floors, pavings etc. finished fair and even complete all as specified.
M & L non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified.
All same as per item No. 48 but fixed in wall dado/ skirting etc with 10 mm thick 1:4 cement mortar back coat - do complete all as specified and directed. (Note for item Nos 48 & 49 : i) Quoted rate is deemed to be inclusive of cement screed/ plaster. ii) Colour of tiles shall be got appproved before incorporation in the work)
M&L M-35 grade, 60 mm thick machine pressed, PVC moulded precast cement concrete interlocking paver blocks any shape and size with grey cement and pigment confirming to IS: 15658-2006, laid over and including 50 mm thick compacted sand cushion complete complete all as specified.(Note: Quoted rate is deemed to be inclusive of 50 mm thick compacted sand cushoning).
M&L for Rendering 20 mm thick in cement mortar 1:4 on brick or concrete surface mixed with WPC @ the weight of minimum 2% by weight of cement mixed or as per manufacturer instruction, and finished the surface even and smooth without using extra cement complete all as specified and directed. Note: WPC measured and paid separately.
M&L for rendering 15 mm thick in CM 1:6 on brick/ block masonry surfaces other than fair faces of brick work finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified.
M&L for rendering 10 mm thick in CM 1:3 on ceiling surfaces of roof projection/ chajjas working height upto 6 mtr finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick in CM 1:3 on ceiling surfaces fair faces of brick work or concrete surfaces finished fair and even complete all as specified.
M&L Three coats of white wash on newly plastered surface of walls after necessary preparation of surface complete all as directed.
M&L Three coats of white wash on newly plastered surface of ceiling after necessary preparation of surface complete all as directed.
M&L for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or unplastered surfaces) and applying two coat of white wash complete all as directed.
M&L for preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of 1 mm thick white cement based wall care putty complete all as specified.
M&L for complete removal of existing treatment and preparing old plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of 1 mm thick white cement based wall care putty complete all as specified.
M&L preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as directed.
M&L for preparing newly plastered surface of walls and applying two coats of acrylic emulsion paint having alkalie and anti fungal resistance, dirt resistance exterior paint of required shade with silicon aditives over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm as per manufacture's instructions complete all as directed. .
Complete removal of any type of existing treatment by mechanical means (any no of layers), Washing, rubbing down and stopping of distempered and painted surfaces of wall surfaces and applying two coats of acrylic emulsion paint having alkalie and anti fungal resistance, dirt resistance exterior paint of required shade with silicon aditives over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm as per manufacture's instructions complete all as directed. .
M & L Two coats of 1st quality synthetic enamel paint over a coat of pink primer on new wooden surface of any description over 10 cm in width or girth including necessary preparation of new wooden surface complete all as directed.
M & L Two coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surface complete all as directed.
M&L for two coats of 1st quality synthetic enamel paint over any description of old painted wood and wood based surface of any description over 10 cm in width or girth including necessary preparation of old wooden surface complete all as directed.
M&L for two coats of 1st quality synthetic enemal paint over any description of old painted steel surface over 10 cm in width or girth including necessary preparation of old steel surface complete all as directed.
S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as directed.
M&L forming Contraction (Dummy) joints 30mm deep x 10mm wide, filled with sealing compound Grade 'A'
M&L for writing letters/ numbers of size 8 to 10 cm high over existing synthetic enamel paint circle of 30 cm dia for describing building numbers as ordered complete all as directed by Engr-in-Charge.
M&L for writing letters/ numbers of size 10 to 15 cm high over existing synthetic enamel paint rectangular marking of size 600 mm x 450 mm for describing periodical services done/ due details in mm/yyyy format as ordered complete all as directed by Engr-in-Charge.
M&L for patch work by application of high build polymer modified cement mortar (1:3) mixed with 6 ltrs SBR per bag of cement as in small patch work of wall/ ceiling surfaces 8 to 30mm thick in two layers surfaces over a coat of bonding agent Nito Bond SBR coat (1 Ltr SBR + 1 Ltr water + 3 kg cement) applied as per manufacturers instructions. Note:- SBR latex chemical will measured and paid separately.
Supply only SBR latex chemical of Make FOSROC or equivalent.
E&M Items: M&L for concealed type point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through including PVC concealed conduit 20mm, concealed MS box/ PVC/ MS/ Cast Iron box and logic modular whtie plates of suitable as required at site with PVC insulated unsheathed stranded copper of size 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 75 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
All as per item No.75 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 75 here-in-above, but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F switch modular type single pole one way 6 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in Philips / Crabtree / ABB / Havells
S&F switch modular type single pole one way 16 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 11 or equivalent in Philips / Crabtree / ABB / Havells
S&F socket outlet 2/3 Pin 6 Amp modular type all accessories complete all as directed. Make: Legrand Cat No. 6755 52 or equivalent in Philips / Crabtree / ABB / Havells
S&F socket outlet multipurpose 2/3 Pin for 6 / 16 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 55 or equivalent in Philips / Crabtree / ABB / Havells
S&F Ceiling rose surface bakelite White / Ivory / Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
S&F 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X020XC 20 W CCT 6500 or equivalent of Bajaj/ Crompton/ Philips/ Wipro/ Havells.
S&F LED street light 45 Watt in aluminium pressure die cast housing and clear injection moulded polycarbonate/ toughene glass (IP 65 protection) having multi chip on board LED and metal clad PCB. The minimum lumen output of the system shall be greater than 4000 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing on bracket including nut bolts, 2.5 Sqmm, 3 core cable and electrically connected fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No ENDURAPEARLNEOSL45WLED757PASYTOPC / Bajaj/ Crompton/ Philips/ Wipro/ Havells.
S&F Ceiling fan 1200 mm sweep, 230 V including step type modular fan regulator 120 W, 2 Module with down rod and making connection from ceiling rose to fan with 3 core 1.5 Sqmm copper conductor of any length wih all accessories as ordered making necessary connection as per manufacturers instructions and testing on completion complete all as directed. Make: Bajaj Model No. Energy Smart 50 1200 mm White C/F (Code-251086) or equivalent of Usha/ Ketan/ Havels.
S&F 300mm sweep metal Body Exhaust Fans AC single phase 230/ 240 V of size complete all as directed. Make: Bajaj Model No Cat No 70069 Supreme Plus 300 mm 900 rpm Ind EX Fan or equivalent in Khetan/ Havells/ Orient.
S&F sheet metal enclosure distribution board VTPN DB 415 V, AC, 4 way with 200 Amps rated bus bar in 25 kA suitable for MCCB four pole as incomer and MCB SP/ TP as outgoing having protection IP 43 protection double door type complete all as specified and directed. Make: Legrand/ Havells/ Indo Asian/ Standard/ L&T
S&F MCCB 125A, 4P, 25 kA with Thermal Magnetic Protection Unit complete all as directed. Make: Legrand Cat. No. 4200 56 or equivalent of Havells/ L&T/ Indo Asian/ Standard
S&F MCB SP 10 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 90 or equivalent of Havells / L&T / ABB
S&F MCB SP 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 95 or equivalent of Havells / L&T / ABB
Supply and lay cable in trenches or fixing on wall or pole XLPE cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (heavy duty) with standard aluminium conductor 1100 volt grade cross sectional area 25 Sqmm 3.5 core making necessary connection & testing on completion all as directed.
S&F 40 mm bore high density polyethylene pipes ISI Marked (HDPE) of pressure rating 6 kgf/cm2 for protection of cable in trenches complete as specified.
Supply and laying in trenches or fixed on wall/ pole 32 mm bore galvanised steel water tubing light grade with fittings such as bends, tees, elbows, nipples, unions, short pieces etc making necessary connection and testing on completion all as specified and directed.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point complete all as specified including testing on completion.
aarti construction
rahil enterprise
M/S Rajendra Constructions
Amar Constructions
suvidhiconstruction
vishalconstruction
1R K Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .