Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC | ₹42.1 L | L1 | Accepted-AOC work awarded to lowest bidder |
| 2 | L2₹47.8 L+₹5.6 L (13.4%)Rejected-Finance R O VILLAGE SAGNAHER P O CHAUNTRA TEHSIL JOGINDER NAGAR DISTT MANDI H P | ₹47.8 L+₹5.6 L (13.4%) | L2 | Rejected-Finance Highest bidder |
| 3 | L3₹49.9 L+₹7.7 L (18.3%)Rejected-Finance | ₹49.9 L+₹7.7 L (18.3%) | L3 | Rejected-Finance Highest bidder |
| 4 | Rejected-Technical CHANDRONA TEHSIL NOHRADHAR DISTRICT SIRMOUR H P | - | - | Rejected-Technical Reject |
| 5 | Rejected-Technical HIMACHAL PRADESH HP | - | - | Rejected-Technical Reject |
| Sl No | Description | Qty | Unit | PARDEEP KUMAR L2 | HEMRAJ THAKUR L1 | SANJAY GOUR L3 |
|---|---|---|---|---|---|---|
| 1.00 | Construction of collectionTank 380000 ltr. Cap. With 1.00 mtr stagging height from ground level to bottom of dome slab comprising of inlet, Scour and over flow pipes as per details given below ground level to top dome of tank including GI bends of required degree, valve of reqiured size confirming to relevants code MS stair case i/c Mild steel flat railing around the container as well as around the complete stair case from bottom to top as per IS-specification, steel ladeer inner and outer side with required dia metre of MS flat of usual height as per site requirment. SFRC manhole cover of 500 mm dia and weight of frame and cover should not be less than 45 kg. ventilator at top dome with minimum opening of 45x450cms water level indicator including floats and measuring gauge lightening conductor with complete earthing arrangment etc. The RCC over head reservoir shall include randering/plastering of the uneven exposed surfact two coats of snowcem paint and any other component required for the completion of the job to the enitre satisfaction of Engineer-in-Charge. The offers shall also include details structural drawing design based on ebaring capacity of soil of propsed site and same shall be approved from the competent authority desigtn clacuation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/MS pipes, duly flanged and sluice valve of required dia metre fitting complete including duck foot bends, puddle collers, expansion joints etc. comecting with rising main and distrubtion main with reqiured legnth from the edge of foundation and any other component required for the completiion of job upto the entire satisfaction of Engineer-in- Charge.
Dia of pipe arrangement
Inlet pipe - 150 mm dia
Outlet pipe - 150 mm dia
Scour pipe - 150 mm dia | 3,80,000 | P/Liters | 6.45 ₹24,51,000 | 5.39 ₹20,48,200 Lowest | 6.83 ₹25,95,400 |
| 2.00 | Construction of storage Reserviror Tank 350000 ltr. Cap. With 1.00 mtr stagging height from ground level to bottom of dome slab comprising of inlet, Scour and over flow pipes as per details given below ground level to top dome of tank including GI bends of required degree, valve of reqiured size confirming to relevants code MS stair case i/c Mild steel flat railing around the container as well as around the complete stair case from bottom to top as per IS-specification, steel ladeer inner and outer side with required dia metre of MS flat of usual height as per site requirment. SFRC manhole cover of 500 mm dia and weight of frame and cover should not be less than 45 kg. ventilator at top dome with minimum opening of 45x450cms water level indicator including floats and measuring gauge lightening conductor with complete earthing arrangment etc. The RCC over head reservoir shall include randering/plastering of the uneven exposed surfact two coats of snowcem paint and any other component required for the completion of the job to the enitre satisfaction of Engineer-in-Charge. The offers shall also include details structural drawing design based on ebaring capacity of soil of propsed site and same shall be approved from the competent authority desigtn clacuation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/MS pipes, duly flanged and sluice valve of required dia metre fitting complete including duck foot bends, puddle collers, expansion joints etc. comecting with rising main and distrubtion main with reqiured legnth from the edge of foundation and any other component required for the completiion of job upto the entire satisfaction of Engineer-in- Charge.
Dia of pipe arrangement
Inlet pipe - 150 mm dia
Outlet pipe - 150 mm dia
Scour pipe - 150 mm dia | 3,50,000 | P/Liters | 6.65 ₹23,27,500 | 6.19 ₹21,66,500 Lowest | 6.83 ₹23,90,500 |
Tender Value
₹68.6 L
EMD Value
₹1.0 L
Closing Date
30 Nov 2023, 11:00 amClosed
Executive Engineer
JSV Division Jawali
Sub Head Construction of Collection tank of 1 meter staging height of 380000 liter capacity at Maira and 350000 Liter capacity at Ther Dhar
2023_HPIPH_81516_1
EE/JSV/Div/JWL/2023-8140-90 dt.16.11.2023
Open Tender
Civil Works
Item Rate
90 days
Jawali
As per notice inviting tender
7 documents required · 7 mandatory
₹800
₹1.0 L
Yes
23 Sept 2025
18 Nov 2023
30 Nov 2023
18 Nov 2023
30 Nov 2023
18 Nov 2023
Amount
Construction of collectionTank 380000 ltr. Cap. With 1.00 mtr stagging height from ground level to bottom of dome slab comprising of inlet, Scour and over flow pipes as per details given below ground level to top dome of tank including GI bends of required degree, valve of reqiured size confirming to relevants code MS stair case i/c Mild steel flat railing around the container as well as around the complete stair case from bottom to top as per IS-specification, steel ladeer inner and outer side with required dia metre of MS flat of usual height as per site requirment. SFRC manhole cover of 500 mm dia and weight of frame and cover should not be less than 45 kg. ventilator at top dome with minimum opening of 45x450cms water level indicator including floats and measuring gauge lightening conductor with complete earthing arrangment etc. The RCC over head reservoir shall include randering/plastering of the uneven exposed surfact two coats of snowcem paint and any other component required for the completion of the job to the enitre satisfaction of Engineer-in-Charge. The offers shall also include details structural drawing design based on ebaring capacity of soil of propsed site and same shall be approved from the competent authority desigtn clacuation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/MS pipes, duly flanged and sluice valve of required dia metre fitting complete including duck foot bends, puddle collers, expansion joints etc. comecting with rising main and distrubtion main with reqiured legnth from the edge of foundation and any other component required for the completiion of job upto the entire satisfaction of Engineer-in- Charge. Dia of pipe arrangement Inlet pipe - 150 mm dia Outlet pipe - 150 mm dia Scour pipe - 150 mm dia
Construction of storage Reserviror Tank 350000 ltr. Cap. With 1.00 mtr stagging height from ground level to bottom of dome slab comprising of inlet, Scour and over flow pipes as per details given below ground level to top dome of tank including GI bends of required degree, valve of reqiured size confirming to relevants code MS stair case i/c Mild steel flat railing around the container as well as around the complete stair case from bottom to top as per IS-specification, steel ladeer inner and outer side with required dia metre of MS flat of usual height as per site requirment. SFRC manhole cover of 500 mm dia and weight of frame and cover should not be less than 45 kg. ventilator at top dome with minimum opening of 45x450cms water level indicator including floats and measuring gauge lightening conductor with complete earthing arrangment etc. The RCC over head reservoir shall include randering/plastering of the uneven exposed surfact two coats of snowcem paint and any other component required for the completion of the job to the enitre satisfaction of Engineer-in-Charge. The offers shall also include details structural drawing design based on ebaring capacity of soil of propsed site and same shall be approved from the competent authority desigtn clacuation expension joints as required at site. The offer shall also include the cost of providing and fixing of GMS/MS pipes, duly flanged and sluice valve of required dia metre fitting complete including duck foot bends, puddle collers, expansion joints etc. comecting with rising main and distrubtion main with reqiured legnth from the edge of foundation and any other component required for the completiion of job upto the entire satisfaction of Engineer-in- Charge. Dia of pipe arrangement Inlet pipe - 150 mm dia Outlet pipe - 150 mm dia Scour pipe - 150 mm dia
PARDEEP KUMAR
SANJAY GOUR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .