Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.5 L+₹2.5 L (10.4%)Rejected-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Non Bonafide | |
| 3 | L3₹26.7 L+₹2.7 L (11.4%)Rejected-AOC 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L3 | Rejected-AOC Non Bonafide | |
| 4 | L4₹27.8 L+₹3.8 L (15.7%)Rejected-AOC OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-AOC Non Bonafide |
Tender Value
Refer Docs
EMD Value
₹58,500
Closing Date
24 Oct 2020, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR
REPAIRS REPLACEMENT OF OLD US LT PANEL JOINTS AND UG LT CABLE IN TECH AREA AT AF STN JODHPUR
2020_MES_380817_1
85862/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jodhpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF JODHPUR
₹58,500
Yes
7 Jan 2021
25 Sept 2020
26 Oct 2020
25 Sept 2020
24 Oct 2020
12 Oct 2020
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil etc complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft / hard dense soil etc complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils etc complete all as specified and directed.
M&L for dry river Sand cusioning for PVC cable with screened & washed sand & punning to provide a required coveretc complete all as specified and directed.
M&L stone slab 40 to 50 mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 to 30 cm wide and thickness not less than 50 mm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning etc complete all as specified and directed.
Supply & fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes including taking out cable cover & cable etc complete all as specified and directed. (a) Ditto above but 4 core 25 Sqmm
(b) Ditto above as per item no-6 but 3.5 core 35 Sqmm
(c)Ditto above as per item no-6 but 3.5 core 50 Sqmm
(d) Ditto above as per item no-6 but 3.5 core 70 Sqmm
(e) Ditto above as per item no-6 but 3.5 core 95 Sqmm
(f) Ditto above as per item no-6 but 3.5 core 120 Sqmm
(g) Ditto above as per item no-6 but 3.5 core 150 Sqmm
(h) Ditto above as per item no-6 but 3.5 core 185 Sqmm
S&F in replacement of armoured heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5/4 Core fixing on wall with clamps, nut and bolt etc complete all as specified and directed. (Location ATC Tower)
S&F in repair Multi functional LED type digital meter suitable for measuring electrical parameters i.e, Amp meter, volt meter, frequency ,power and power factor meter, etc 3 phase Class 1 AC with epoxy type CT suitable ratio and complete wiring L&T MFM 4410 CI 1 RS485 CAT Pt No WL441011OOOO and equivellent etc complete all as specified and directed.Make : Scheneider/Neptune/AE.
Dismantling and taking down old unserviceable feeder piller boxes /LT Panel board any type by disconnecting electric connections etc complete all as specified and directed.
S&F in repair cable joint kit for 11 KV grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm etc complete all as specified and directed. Make : Denson/Birla 3M/M-Seal.
S&F in repair cable joint kit for 11 KV grade cable for straight through cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm etc complete all as specified and directed. Make : Denson/Birla 3M/M-Seal.
M&L Boring of holes under road pavement,hard stansding by trenchess technology using manual method directed as per Engineer-in- Charge.
M&L in repair for LT Feeder Pillar ( Kiosk)of size not less than L=60 cmx 45 cm x45 cm (H) made out 2 mm thick out door type CPRI approved) with openable Front door including locking arrangement with Copper Busbar 200 amps rating with MCCB 125 Amps ,25 KA and fixed on angle iron frame and PCC plinth etc complete all as specified and directed.(Location: Near 2218 tech flt Gate , near SBI Bank , Bomb dumb area)
S&F phase indicator lamps LED type moulded single piece (Red/Yellow/Blue) suitable for LT panel after taking out the old U/S indicator lamps etc complete all as specified and directed.
S&F in repair of MCCBs etc complete all as specified and directed. Make :Legrand/L&T/ABB. (a) Ditto above but MCCB 400 Amp 4 pole 415 V 36KA
(b) Ditto above as per item no-6 but MCCB 250 Amp 4 pole 415 V,25KA
(c) Ditto above as per item no-6 but MCCB 200 Amp 4 pole 415 V,25KA
(d) Ditto above as per item no-6 but MCCB 160 Amp 4 pole 415 V,25KA
(e) Ditto above as per item no-6 but MCCB 125 Amp 4 pole 415 V,25KA
(f) Ditto above as per item no-6 but MCCB 100 Amp 4 pole 415 V,25KA
(g) Ditto above as per item no-6 but MCCB 63A,16KA,4 pole 415 V
Supply, install, testing and commissioning on load change over switch 100 Amps , four pole 415V AC ,50HZ etc in sheet metal enclosure etc complete all as specified and directed.Make: L&T/HPL/Havells.
Supply, install, testing and commissioning on load change over switch 125 Amps , four pole 415V AC ,50HZ etc in sheet metal enclosure etc complete all as specified and directed.Make: L&T/HPL/Havells.
Supply, install, testing and commissioning on load change over switch 200 Amps , four pole 415V AC ,50HZ etc in sheet metal enclosure etc complete all as specified and directed.Make: L&T/HPL/Havells.
Supply, install, testing and commissioning on load change over switch 315 Amps , four pole 415V AC ,50HZ etc in sheet metal enclosure etc complete all as specified and directed.Make: L&T/HPL/Havells.
Supply, install, testing and commissioning on load change over switch 400 Amps , four pole 415V AC ,50HZ etc in sheet metal enclosure etc complete all as specified and directed.Make: L&T/HPL/Havells.
Repair and maint of LT panel including,painting of panel dual coat of enamel paint gland connection of LT cables of all size including replacement of Lugs and insulation of bus baars ,rewiring of LT panel including all accessories,cleaning of LT panel ,welding of LT panel to its angle iron frameother PCC related work ,hinjes replacement,locking arrangement and all other small maint work as directed by Engineer-in-Charge.
Supply only alluminium bus baar of LT panel including pvc insulation,reconnection of LT cable and seprator all as directed by Engineer-in-Charge.
Supply only copper bus baar of LT panel including pvc Insulation ,reconnection of LT cable and seprator all as directed by Engineer-in-Charge.
Supply only LT panel /AMF panel/HT bus panel front /back door made of GI 3.15 mm thick with hinjes and lock system,panel should be well welded all as directed by Engineer-in-Charge.
M&L in repairs Angle iron frame with with one coat of red oxidepaint and over a coat of black paint complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete type C1 1:3:6 in 20mm graded aggregate for pole coping/foundation/ hard standing complete as directed by Engineer-in-Charge.
Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I incl all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc all as specified and as directed by Engineer-in-Charge.
Supply only aluminium cable lugs of size 6 sq mm to 10 sq mm etc complete all as specified and directed.
Supply only aluminium cable lugs of size 16 sq mm to 50 sq mm etc complete all as specified and directed.
Supply only aluminium cable lugs of size 70 sq mm to 150 sq mm etc complete all as specified and directed.
Supply only aluminium cable lugs of size 185 sq mm to 240 sq mmetc complete all as specified and directed.
Supply only aluminium cable lugs of size 240 sq mm to 400 sq mm etc complete all as specified and directed.
Supply only aluminium cable lugs of size 500 sq mm to 630 sq mm etc complete all as specified and directed.
M&L in replacement for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5metc complete all as specified and directed.
Supply and laying in replacement rubber mat of Size 6' x 3' x 1/2" etc complete all as specified and directed.Make : ATLAS /Jyoti
M&L for stay assembly complete with accessories as shown in electric plate No.I including loop type insulator, stay clamps etc complete all as specified & directed with diameter of stay 20 mm of stay rod etc complete all as specified and directed.
M&L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations of poles / struts includings necessary form work etc complete all as specified and directed.
M&L for dismantling existng LT Panels from old location at sunsheltor to proposed new location at Sunsheltor Tech Area by properly disconnecing all electrical connections and shifting to new proposed location and taking suitable safty measure while handling and shifting the LT Panel including require foundation for panel , painting of panel, repair of door and reconnection of all electrical connectioins and testing and commisioning etc complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling existng 100 KVA DG set from ER II sub station to Hanger No II by properly disconnecing all electrical connections,panel and DG set , shifting to Hanger II taking suitable safely measure while handling and shifting of the Dg set current location to proposed location including require foundation for panel , Dg set and reconnection of all electrical connectioins and testing and commisioning etc complete all as specified and directed.
Disconnecting 1.1 KV grade XLPE cable of any size from structure/pole/ transformer/LT panel/FPB for finding fault and its location including cutting faulty cable to facilitate joint and testing remaining part of cable for any further fault using cable fault locating equipment including bringing approved cable fault locating equipment & to be taken back after finding fault is over etc complete all as specified and directed. Note :- Excavation and earth work and supply & fix joints shall be measured and paid for separately.
Taking out carefully LT cable of any size on the wall/ suface and Rerounting of cables properly connection on the wall /surface with clamping nut bolt etc complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 25 sq mm to 50 sqmm etc complete all as specified and directed. Make: 3M/M Seal/ Raychem.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 70 sqmm to 120 sq mm etc complete all as specified and directed.Make: 3M/M Seal/ Raychem.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 150 sq mm to 185 sqmm etc complete all as specified and directed.Make: 3M/M Seal/ Raychem.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 240 sq mm to 300 sqmm etc complete all as specified and directed.Make: 3M/M Seal/ Raychem.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 400 sq mm etc complete all as specified and directed.Make: 3M/M Seal/ Raychem.
S&F in replacement GI tubing light grade 80 mm dia for /pole cable protection including fixing clamp, nut bolt washer complete accssories etc complete all as specified and directed.Make: Prakash / Surya / TATA / Jindal.
Surface cleaning/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms, two pole/ four pole structure surroundings to make a over all presentable condition all as directed by Engineer-in-Charge.
M&L of checking of HT 11/33KV cable of any size by means of HT Cable Fault Locator Machine by requisition for removal of HT cable faults etc complete all as specified and directed.
S&F in replacement Danger notice plate of 1.6 mm thick mild steel sheet,vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S Clamps, bolts and nuts of size 20 x 15 cm etc complete all as specified and directed.
S&F in replacement terminal protetor/Angle rubber boots for Transformer/RMU cable protection etc complete all as specified and directed. Make: 3M/M Seal/ Raychem.
S&F Mobile sockets & Staight Plugs 380/415 v,32A 3P+N+E of M/s Legrand Cat No 5552 19 & 5552 39 or equivalent in M/s Havells/ M/s L &T as in replacement/ repairs etc complete all as specified and directed.
Supply and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts, and screws as specified type confirming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete etc complete all as specified and directed for the following:- NOTE :- Excavation and earth work and PCC foundation and plinth will be measured and paid separately under respective items of Sch ‘A’. (a) Ditto as above but 410 SP-31 (9 mtr long)
(b) Ditto as per above item no-67 but 410 SP -22 (8.5 mtr long)
Taking out Centrifugal pump type Make Kirloskar, RPM 1250, HP 10 from foundation by disconnecting suction & delivery pipe line, dismantling of pump, overhauling the same by repairing/replacing defective parts as ordered and reassembling, replacement of worn out nuts, bolts, repairing of bearing housing complete incl greasing and making connection complete all as directed.(Location: Near Blast Pen 34 & Near Blast Pen36).
(a) Material only bronze impeller with neck ring.
(b) Material only ball bearing DE + NDE (Make NBC/SKF)
(c) Material only Gun Metal bush.
(d) Material only MS gland cap.
(e) Material only rubber bush/star coupling.
(f) Material only MS coupling set with pin.
Taking out electric motor AC 3 phase 415 volts from foundation, taken to work shop, dismantling the motor, taking out old burnt wiring, cleaning the starter slots, material and labour for rewinding the stator with appropriate gauge super enameled copper wire and installation paper, sleeves, thimbles etc, complete varnishing and backing up the windings, repairs to bearing housings, replacing the bearings, cooling fan and connection plate, taking back to site, fixing on foundation making electric connection, realigning with pump and testing etc complete all as specified and directed. of following size :- (a) 7.5 HP Cap.(Location: Near Blast Pen 32 to 38).
(b) Ditto as per above item no-76 but 10 HP Cap.(Location: 10 Sqn Taxi Track Gate).
Dismantling the WORM GEAR UNIT, Ration 30:1 ,Model AU overhauling the same by repair/replacing the defective parts as ordered, cleaning varnishing and drying, re-erecting, aligning with the motor, testing and commissioning, any other minor parts required for proper functioning, painting the unit with two coat of synthetic enamel paint after preparing the surface and replacement of worn out nut bolts, stud of gland capacity including making over size complete all as directed by Engineer-in-Charge.(Location: 10 Sqn Taxi Track Gate).
M&L for in repair cold shrinkable cable end termination joint including jointing kit outdoor type suitable for earthed 3 core 95 sqmm HT 11 KV XLPE aluminium conductor cable and HV test after jointing etc complete all as specified and directed.
M&L for in repair cold shrinkable cable end termination joint including jointing kit indoor type suitable for earthed 3 core 95 sqmm HT 11 KV XLPE aluminium conductor cable and HV test after jointing etc complete all as specified and directed.
M&L cross arms, bracing, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint etc complete all as specified and directed.
M&L for dismantling existng 82.5 KVA DG set from 2252 Hanger to New location 2252 sqn annexe Bldg by properly disconnecing all electrical connections,panel and DG set , shifting to New location 2252 sqn annexe Bldg taking suitable safely measure while handling and shifting of the Dg set current location to proposed location including require foundation for panel , Dg set and reconnection of all electrical connectioins and testing and commisioning etc complete all as specified and directed.
SANJOLI CONSTRUCTION COMPANY
M/S JAGDAMBA ENTERPRISES
Harsh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .