Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹145.9 CrAccepted-AOC | ₹145.9 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹157.8 CrRejected-Finance | ₹157.8 Cr | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹162.7 CrRejected-Finance | ₹162.7 Cr | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹187.1 CrRejected-Finance H NO 8 2 2 1 FLAT NO 203 SITARAMA APARTMENT OPP AXIS BANK PANJAGUTTA HYDERABAD 500 082 | HYDERABAD | TELANGANA | 500082 | ₹187.1 Cr | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹206.3 CrRejected-Finance | ₹206.3 Cr | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹140 Cr
EMD Value
₹15 L
Closing Date
29 Oct 2022, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
Chief Engineer (Navy) Visakhapatnam Station Road Visakhapatnam-530 004
PROVISION OF DEFICIENT MARRIED ACCOMMODATION (420 DUs) FOR SAILORS AT VISAKHAPATNAM
2021_MES_484236_1
85391
Open Tender
Civil Works
1095 days
Visakhapatnam
Please refer Tender documents.
12 documents required · 12 mandatory
₹3,000
GE P Navy Visakhapatnam
₹15 L
Chief Engineer Navy Visakhapatnam
9 Dec 2022
27 Oct 2021
31 Oct 2022
27 Oct 2021
29 Oct 2022
17 Oct 2022
18 Nov 2021
Amount
SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XVI: Note: Schedule 'A' Part-I to Part-XVI (Including Parts A & B separately for Restricted & Unrestricted areas) are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lump Sum price worked out by the contractor for 'Buildings & Structures in Restricted Area', as listed in Schedule 'A' Part-I A.
Lump Sum price worked out by the contractor for 'Buildings & Structures in Unrestricted Area', as listed in Schedule 'A' Part-I B.
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation in Restricted Area', as listed in Schedule 'A' Part-II A.
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation in Unrestricted Area', as listed in Schedule 'A' Part-II B.
Lump Sum price worked out by the contractor for 'Pile Foundation in Restricted Area', as listed in Schedule 'A' Part-III A.
Lump Sum price worked out by the contractor for 'Pile Foundation in Unrestricted Area', as listed in Schedule 'A' Part-III B.
Lump Sum price worked out by the contractor for 'Internal Water Supply in Restricted Area', as listed in Schedule 'A' Part-IV A.
Lump Sum price worked out by the contractor for 'Internal Water Supply in Unrestricted Area', as listed in Schedule 'A' Part-IV B.
Lump Sum price worked out by the contractor for 'Internal Electrification in Restricted Area', as listed in Schedule 'A' Part-V A.
Lump Sum price worked out by the contractor for 'Internal Electrification in Unrestricted Area', as listed in Schedule 'A' Part-V B.
Lump Sum price worked out by the contractor for 'External Water Supply in Restricted Area', as listed in Schedule 'A' Part-VI A.
Lump Sum price worked out by the contractor for 'External Water Supply in Unrestricted Area', as listed in Schedule 'A' Part-VI B.
Lumpsum price worked out by the contractor for 'External Electrification in Restricted Area', as listed in Schedule 'A' Part-VII A.
Lumpsum price worked out by the contractor for 'External Electrification in Unrestricted Area', as listed in Schedule 'A' Part-VII B.
Lump Sum price worked out by the contractor for 'Area Drainage in Restricted Area', as listed in Schedule 'A' Part-VIII A.
Lump Sum price worked out by the contractor for 'Area Drainage in Unrestricted Area', as listed in Schedule 'A' Part-VIII B.
Lump Sum price worked out by the contractor for 'Sewage Disposal in Restricted Area', as listed in Schedule 'A' Part-IX A.
Lump Sum price worked out by the contractor for 'Sewage Disposal in Unrestricted Area', as listed in Schedule 'A' Part-IX B.
Lump Sum price worked out by the contractor for 'Sewage Disposal E/M', as listed in Schedule 'A' Part-IX C.
Lump Sum price worked out by the contractor for 'Road/Path/Culvert in Restricted Area', as listed in Schedule 'A' Part-X A.
Lump Sum price worked out by the contractor for 'Road/Path/Culvert in Unrestricted Area', as listed in Schedule 'A' Part-X B.
Lump Sum price worked out by the contractor for 'Retaining Wall/Compound Wall/Gate', as listed in Schedule 'A' Part-XI.
Lump Sum price worked out by the contractor for 'Rain Water Harvesting in Restricted Area', as listed in Schedule 'A' Part-XII A.
Lump Sum price worked out by the contractor for 'Rain Water Harvesting in Unrestricted Area', as listed in Schedule 'A' Part-XII B.
Lump Sum price worked out by the contractor for 'Fire Fighting in Restricted Area', as listed in Schedule 'A' Part-XIII A.
Lump Sum price worked out by the contractor for 'Fire Fighting in Unrestricted Area', as listed in Schedule 'A' Part-XIII B.
Lump Sum price worked out by the contractor for 'Fire Alarm in Restricted Area', as listed in Schedule 'A' Part-XIV A.
Lump Sum price worked out by the contractor for 'Fire Alarm in Unrestricted Area', as listed in Schedule 'A' Part-XIV B.
Lump Sum price worked out by the contractor for 'Arboriculture in Restricted Area', as listed in Schedule 'A' Part-XV A.
Lump Sum price worked out by the contractor for 'Arboriculture in Unrestricted Area', as listed in Schedule 'A' Part-XV B.
Lump Sum price worked out by the contractor for 'Demolition & Dismantling', as listed in Schedule 'A' Part-XVI.
SCHEDULE 'A' PART-XVII: (MISCELLANEOUS ITEMS):
PILE FOUNDATION IN RESTRICTED AREA:
Boring for bored cast-in-situ piles 450mm dia. in any type of soil/clay/ soft rock except hard rock/fractured rock using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MoD land complete all as specified and as shown on drawings and as directed.
Boring for bored cast-in-situ piles 600mm dia. in any type of soil/clay/ soft rock except hard rock/fractured rock using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MoD land complete all as specified and as shown on drawings and as directed.
Boring for 450mm dia. bored cast in situ piles in hard rock and getting out and disposal of spoil out side MoD land using DMC method (Direct Mud Circulation) complete all as specified and shown on drawings and as directed.
Boring for 600mm dia. bored cast in situ piles in hard rock and getting out and disposal of spoil out side MoD land using DMC method (Direct Mud Circulation) complete all as specified and shown on drawings and as directed.
Chipping of laitance concrete in piles above cut off level up to a maximum of 1m from cut of level and disposal to out side MD land and depositing where directed complete all as specified and as directed.
Carrying out initial load vertical test on 450mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out initial lateral load test on 450mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out initial vertical load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out initial lateral load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out routine vertical load test on 450mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out routine lateral load test on 450mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out routine vertical load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out routine lateral load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out low strain integrity test on cast in situ piles 450mm/600mm dia. including analysing the result as per ASTM D 5882 complete all as specified and as directed. Note fot Item Nos.37 to 45: Test results shall be approved by the CWE. The GE shall intimate CWE before commencing the load test and the test shall be carried out in presence of the authorised representative detailed by the CWE.
PILE FOUNDATION IN UNRESTRICTED AREA:
Boring for bored cast-in-situ piles 600mm dia. in any type of soil/clay/ soft rock except hard rock/fractured rock using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed.
Boring for 600mm dia. bored cast in situ piles in hard rock and getting out and disposal of spoil out side MD land using DMC method (Direct Mud Circulation) complete all as specified and shown on drawings and as directed.
Chipping of laitance concrete in piles above cut off level up to a maximum of 1m from cut of level and disposal to out side MD land and depositing where directed complete all as specified and as directed.
Carrying out initial vertical load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out initial lateral load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out routine vertical load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out routine lateral load test on 600mm dia. pile as per IS 2911 Part-IV, complete all as specified and as directed.
Carrying out low strain integrity test on cast in situ piles 600mm dia. including analysing the result as per ASTM D 5882 complete all as specified and as directed. Note fot Item Nos.49 to 53: Test results shall be approved by the CWE. The GE shall intimate CWE before commencing the load test and the test shall be carried out in presence of the authorised representative detailed by the CWE.
INTERNAL WATER SUPPLY IN RESTRICTED AREA:
S&F MS ERW pipe heavy duty on wall/roof top 32mm bore including all fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc fixed to walls and ceilings or laid in floors and including necessary welding for marking necessary tappings etc. complete all as specified and as directed.
S&F MS ERW pipe heavy duty on wall/roof top 100mm bore including all fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc fixed to walls and ceilings or laid in floors and including necessary welding for marking necessary tappings etc. complete all as specified and as directed.
S&F long body bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F long body bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F two way bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F two way bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F pillar taps 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts screwed for pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F pillar taps 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts screwed for pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F brass CP mixer 15mm dia. fancy type, for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed.
S&F angular cock 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F angular cock 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F health faucet 15mm dia., ABS rubbit cleaning system, with 1.25m long PVC flexible tube and ABS wall hook complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F health faucet 15mm dia., ABS rubbit cleaning system, with 1.25m long PVC flexible tube and ABS wall hook complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F PTMT shower rose 125mm size with or without swivel joints, any size, including fixing to CPVC pipe or union (Minimum weight 40gms) complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F PTMT shower rose 125mm size with or without swivel joints, any size, including fixing to CPVC pipe or union (Minimum weight 40gms) complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F water meter, brass, multi jet class, screwed type, 32mm dia. covered with metal box of suitable size made out of CRCA sheet 3mm thick with locking arrangement duly painted with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
INTERNAL WATER SUPPLY IN UNRESTRICTED AREA:
S&F MS ERW pipe heavy duty on wall/roof top 32mm bore including all fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc fixed to walls and ceilings or laid in floors and including necessary welding for marking necessary tappings etc. complete all as specified and as directed.
S&F MS ERW pipe heavy duty on wall/roof top 100mm bore including all fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc fixed to walls and ceilings or laid in floors and including necessary welding for marking necessary tappings etc. complete all as specified and as directed.
S&F long body bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F long body bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F two way bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F two way bib taps 15mm dia. cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F pillar taps 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts screwed for pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F pillar taps 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts screwed for pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F brass CP mixer 15mm dia. fancy type, for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed.
S&F angular cock 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F angular cock 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F health faucet 15mm dia., ABS rubbit cleaning system, with 1.25m long PVC flexible tube and ABS wall hook complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F health faucet 15mm dia., ABS rubbit cleaning system, with 1.25m long PVC flexible tube and ABS wall hook complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F PTMT shower rose 125mm size with or without swivel joints, any size, including fixing to CPVC pipe or union (Minimum weight 40gms) complete all as specified and as directed. Note: The maximum flow rate shall be 03 LPM
S&F PTMT shower rose 125mm size with or without swivel joints, any size, including fixing to CPVC pipe or union (Minimum weight 40gms) complete all as specified and as directed. Notes: 1. The maximum flow rate shall be 06 LPM 2. The item is considered for each DU of the top floor of each block.
S&F water meter, brass, multi jet class, screwed type, 32mm dia. covered with metal box of suitable size made out of CRCA sheet 3mm thick with locking arrangement duly painted with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
INTERNAL ELECTRIFICATION IN RESTRICTED AREA:
Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly, for One light point controlled by one switch or One bell point controlled by bell push or One fan (ceiling fan/exhaust fan) point controlled by one switch on independent board complete all as specified and directed.
All as per item No.86 here-in-before but for one light point controlled by two Nos. two way switches complete all as specified and directed.
All as per item No.86 here-in-before but for one 3 Pin socket outlet 5 Amps socket on independent board with 2.5 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuity complete all as specified and directed.
All as per item No.86 here-in-before but for one 3 Pin socket outlet 5 Amps socket on the same board with 2.5 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuity complete all as specified and directed.
All as per item No.86 here-in-before but for one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity complete all as specified and directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 2.5 Sq.mm. cable and one run of 2.5 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 25mm dia. with accessories complete with four runs of 16 Sq.mm. cable and one run of 16 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed. Note for Item Nos.91 to 93: Two/Four (As specified) runs of cable, one run of earth wire and one run of conduit will be measured as one unit.
S&F telephone socket with shutter glossy white with terminal box and fixing plate complete all as specified and as directed.
S&F TV socket including perforated terminal box and switch plate complete all as specified and as directed.
S&F angle holder PVC/polycarbonate body with back plate complete all as specified and as directed.
S&F concealed in wall vertical MCB DB double door type, TPN 4 way, 415 Volts, 50 Hz, IP 43 protection with 200 Amps rated bus bar including provision for fixing MCCB FP 63 Amps as incommer and out going circuits MCB SP/TP complete, filling empty way with blanking plates complete all as spcified and as directed. Note: MCCB & MCBs shall be measured and paid separately.
S&F LED adore lamp 10 Watts, 240 Volts AC, B22 type, CDS 5 star complete all as specified and as directed.
S&F energy efficient LED tube light fitting 5 Watts, with tube, 240 Volts, 50 Hz, BEE 3 star rating, surface mounted, decorative ultra slim square prfile, with extruded polycarbonate, environment friendly including mounting bracket etc., including connecting up with copper conductor cable with suitable size complete all as specified and as directed.
S&F energy efficient LED tube light fitting 10 Watts, with tube, 240 Volts, 50 Hz, BEE 3 star rating, surface mounted, decorative ultra slim square prfile, with extruded polycarbonate, environment friendly including mounting bracket etc., including connecting up with copper conductor cable with suitable size complete all as specified and as directed.
S&F energy efficient LED tube light fitting 20 Watts, with tube, 240 Volts, 50 Hz, BEE 3 star rating, surface mounted, decorative ultra slim square prfile, with extruded polycarbonate, environment friendly including mounting bracket etc., including connecting up with copper conductor cable with suitable size complete all as specified and as directed.
S&F LED security light fitting 30 Watts, with tube, new generation energy saving, BEE 3 star rating, environment friendly, long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection including 1.5m long 32mm dia. light grade GI tubing bent to shape for fixing on wall/pole with suitable MS brackets, nuts and bolts etc. including connecting up with copper conductor cable with suitable size complete all as specified and as directed.
S&F ceiling fans BLDC type, AC single Phase, 240 Volts of size 1200mm sweep with complete set with fixtures, 5 Star rating, metallic body complete all as specified and as directed.
S&F exhaust fan 250mm sweep plastic body, complete with louvers suitable for operation on 230 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
S&F exhaust fan 300mm sweep metallic body (Heavy duty), complete with louvers suitable for operation on 230 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
M&L earth continuity conductor of copper strip 20x3mm size or main earthing lead fixed to wall on GI pipe light grade 25mm dia. for protection of earth strips or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation (VTPN DB in each floor of the building to be connected to two Nos. earthing parallelly) complete all as specified and as directed.
S&F smart single phase energy meter with AC, two wire, tamper proof static meter of class 1.0, 240 Volts, 50 Hz, 10 Amps to 60 Amps, conforming to IS 15444 and relevant IEC standard with inbuilt 865-867 MHz ratio frequency, communication facility with self healing mesh network with default and on demand display, billing, data generation facility, anti-tamper features, microprocessor and LED/LCD based circuitry, suitable for supporting 30 min. instrumentaneous data for voltage, current, power factor, power cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for cumulative energy and maximum demand including connect/disconnect functionality operatable from prepaid billing software, supporting open communication protocol DLMS with the software complete all as specified and as directed by the Engineer-in-Charge.
S&F prefabricated meter box of size 50x60 cm, made out of 2mm thick CRCA sheet duly powder coated, to accommodate 6 Nos. single phase energy meters, provided the front portion of the box with 6 Nos. slit openings covered with glass, including necessary arrangements inside the box to fix the energy meters and necessary locking arrangements and including sealing the energy meters (energy meters measured separately) complete all as specified and as directed.
S&F PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, both end of the cable duly taged/marked in colour code sleeves of each quarter number complete all as specified and as directed.
S&F PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, both end of the cable duly taged/marked in colour code sleeves of each quarter number complete all as specified and as directed.
S&F PVC junction box of size 10x15 cm rectangular type concealed to wall to accommodate six way PVC connector for telephone cable on each floor (For three Dus) complete all as specified and as directed.
S&F FRP body junction box of size 10x15 cm with and including PVC connector three way or telephone cable on each floor complete all as specified and as directed.
S&F FRP body junction box of size 50x30 cm with and including PVC connector 56 way or telephone cable on each floor complete all as specified and as directed.
INTERNAL ELECTRIFICATION IN UNRESTRICTED AREA:
Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly, for One light point controlled by one switch or One bell point controlled by bell push or One fan (ceiling fan/exhaust fan) point controlled by one switch on independent board complete all as specified and directed.
All as per item No.115 here-in-before but for one light point controlled by two Nos. two way switches complete all as specified and directed.
All as per item No.115 here-in-before but for one 3 Pin socket outlet 5 Amps socket on independent board with 2.5 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuity complete all as specified and directed.
All as per item No.115 here-in-before but for one 3 Pin socket outlet 5 Amps socket on the same board with 2.5 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuity complete all as specified and directed.
All as per item No.115 here-in-before but for one 3 pin socket outlet 15 Amps on independent board with 4 Sq.mm. FRLS PVC wire and one run of 4 Sq.mm. copper cable for earth continuity complete all as specified and directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 2.5 Sq.mm. cable and one run of 2.5 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 25mm dia. with accessories complete with four runs of 16 Sq.mm. cable and one run of 16 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed. Note for Item Nos.120 to 122: Two/Four (As specified) runs of cable, one run of earth wire and one run of conduit will be measured as one unit.
S&F telephone socket with shutter glossy white with terminal box and fixing plate complete all as specified and as directed.
S&F TV socket including perforated terminal box and switch plate complete all as specified and as directed.
S&F angle holder PVC/polycarbonate body with back plate complete all as specified and as directed.
S&F concealed in wall vertical MCB DB double door type, TPN 4 way, 415 Volts, 50 Hz, IP 43 protection with 200 Amps rated bus bar including provision for fixing MCCB FP 63 Amps as incommer and out going circuits MCB SP/TP complete, filling empty way with blanking plates complete all as spcified and as directed. Note: MCCB & MCBs shall be measured and paid separately.
S&F LED adore lamp 10 Watts, 240 Volts AC, B22 type, CDS 5 star complete all as specified and as directed.
S&F energy efficient LED tube light fitting 5 Watts, with tube, 240 Volts, 50 Hz, BEE 3 star rating, surface mounted, decorative ultra slim square prfile, with extruded polycarbonate, environment friendly including mounting bracket etc., including connecting up with copper conductor cable with suitable size complete all as specified and as directed.
S&F energy efficient LED tube light fitting 10 Watts, with tube, 240 Volts, 50 Hz, BEE 3 star rating, surface mounted, decorative ultra slim square prfile, with extruded polycarbonate, environment friendly including mounting bracket etc., including connecting up with copper conductor cable with suitable size complete all as specified and as directed.
S&F energy efficient LED tube light fitting 20 Watts, with tube, 240 Volts, 50 Hz, BEE 3 star rating, surface mounted, decorative ultra slim square prfile, with extruded polycarbonate, environment friendly including mounting bracket etc., including connecting up with copper conductor cable with suitable size complete all as specified and as directed.
S&F LED security light fitting 30 Watts, with tube, new generation energy saving, BEE 3 star rating, environment friendly, long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection including 1.5m long 32mm dia. light grade GI tubing bent to shape for fixing on wall/pole with suitable MS brackets, nuts and bolts etc. including connecting up with copper conductor cable with suitable size complete all as specified and as directed.
S&F ceiling fans BLDC type, AC single Phase, 240 Volts of size 1200mm sweep with complete set with fixtures, 5 Star rating, metallic body complete all as specified and as directed.
S&F exhaust fan 250mm sweep plastic body, complete with louvers suitable for operation on 230 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
S&F exhaust fan 300mm sweep metallic body (Heavy duty), complete with louvers suitable for operation on 230 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
M&L earth continuity conductor of copper strip 20x3mm size or main earthing lead fixed to wall on GI pipe light grade 25mm dia. for protection of earth strips or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation (VTPN DB in each floor of the building to be connected to two Nos. earthing parallelly) complete all as specified and as directed.
S&F smart single phase energy meter with AC, two wire, tamper proof static meter of class 1.0, 240 Volts, 50 Hz, 10 Amps to 60 Amps, conforming to IS 15444 and relevant IEC standard with inbuilt 865-867 MHz ratio frequency, communication facility with self healing mesh network with default and on demand display, billing, data generation facility, anti-tamper features, microprocessor and LED/LCD based circuitry, suitable for supporting 30 min. instrumentaneous data for voltage, current, power factor, power cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for cumulative energy and maximum demand including connect/disconnect functionality operatable from prepaid billing software, supporting open communication protocol DLMS with the software complete all as specified and as directed by the Engineer-in-Charge.
S&F prefabricated meter box of size 50x60 cm, made out of 2mm thick CRCA sheet duly powder coated, to accommodate 6 Nos. single phase energy meters, provided the front portion of the box with 6 Nos. slit openings covered with glass, including necessary arrangements inside the box to fix the energy meters and necessary locking arrangements and including sealing the energy meters (energy meters measured separately) complete all as specified and as directed.
S&F PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, of Havells make basic code No.WHTTATEL1P40 or equivalent in other makes, both end of the cable duly taged/marked in colour code sleeves of each quarter number complete all as specified and as directed.
S&F PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, of Havells make basic code No.WHTTATEL3P40 or equivalent in other makes, both end of the cable duly taged/marked in colour code sleeves of each quarter number complete all as specified and as directed.
S&F PVC junction box of size 10x15 cm rectangular type concealed to wall to accommodate six way PVC connector for telephone cable on each floor (For three Dus) complete all as specified and as directed.
S&F FRP body junction box of size 10x15 cm with and including PVC connector three way or telephone cable on each floor complete all as specified and as directed.
S&F FRP body junction box of size 50x30 cm with and including PVC connector 56 way or telephone cable on each floor complete all as specified and as directed.
EXTERNAL WATER SUPPLY IN RESTRICTED AREA:
M&L laying of ductile iron pipe 150mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed.
M&L laying of ductile iron pipe 100mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed.
M&L brick masonry valve chamber of size 750x750x750mm including necessary excavation, PCC foundation, brick work, plastering and 40x40x6mm angle iron frame with MS sheet cover of 6mm thick including locking arrangement with two coats of red oxide primer and one coat of synthetic enamel paint of approved colour complete all as specified and as directed.
M&L for cutting existing steel tubing 150mm dia. for alterations or additions necessarily done in position with out taking down and inserting 'TEE' of size 150x150x150mm for tapping complete all as specified and as directed.
M&L for cutting existing steel tubing 100mm dia. for alterations or additions necessarily done in position with out taking down and inserting 'TEE' of size 100x100x100mm for tapping complete all as specified and as directed.
M&L galvanised iron strip 32x6mm size buried in ground/fixed to wall/ floor etc. complete all as specified and as directed.
S&F flanged end lift type foot valve 100mm dia. with brass strainer, suitable flanges, nuts, bolts, gaskets etc. complete all as specified and as directed.
Supply, install, testing and commissioning of monoblock pump set with minimum ratings as 15 HP, 70 Mtr head, discharge 1000 LPM with delivery size of 80mm bore, 415 Volts, 50 Hz, AC 3 Phase supply, electric driven, inclusive of air valve at delivery, pressure guage along with cabling by XLPE copper cables from starter to pump set with cable tray and PCC foundation complete all as specified and as directed.
S&F star delta starter for monoblock pump sets with fixing arrangement for capacity of 15 HP pump complete all as specified and as directed.
S&F digital type water meter (Electromagnetic type) flanged type, MS body, for smart metering, of high accuracy, robust designe, IP-67 enclosure, max flow 1500 lpm for residential water supply scheme for fixing to 80mm dia. GI/DI pipe line, with and inlussive of necessary nuts, bolts and washer for fixing, necssary excavation/retuning filling in, and connecting FRLS PVC insulated 3 core, PVC sheathed unarmoured copper wire drawn through GI pipe light grade 20mm dia. as required at site and making connection complete all as specified and as directed.
S&F digital type water meter (Electromagnetic type) flanged type, MS body, for smart metering, of high accuracy, robust designe, IP-67 enclosure, max flow 2016 lpm for residential water supply scheme for fixing to 100mm dia. MS/DI pipe line, with and inlussive of necessary nuts, bolts and washer for fixing, necssary excavation/retuning filling in, and connecting FRLS PVC insulated 3 core, PVC sheathed unarmoured copper wire drawn through GI pipe light grade 20mm dia. as required at site and making connection complete all as specified and as directed.
S&F digital type water meter (Electromagnetic type) flanged type, MS body, for smart metering, of high accuracy, robust designe, IP-67 enclosure, max flow 5300 lpm for residential water supply scheme for fixing to 150mm dia. MS/DI pipe line, with and inlussive of necessary nuts, bolts and washer for fixing, necssary excavation/retuning filling in, and connecting FRLS PVC insulated 3 core, PVC sheathed unarmoured copper wire drawn through GI pipe light grade 20mm dia. as required at site and making connection complete all as specified and as directed. Note for Item Nos.154 to 156: Excavation & earthwork, FRLS cable and GI pipe shall be measured and paid seperately.
S&L PVC insulated FRLS cable copper conductor 3 core 2.5 Sq.mm. PVC sheathed unarmoured drawn through GI pipe light grade complete all as specified and as directed. Note: Excavation & earthwork and GI pipe shall be measured and paid seperately.
M&L for GI pipe light grade 20mm dia. laid in trenches or fixed to wall complete all as specified and as directed.
EXTERNAL WATER SUPPLY IN UNRESTRICTED AREA:
M&L laying of ductile iron pipe 150mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed.
M&L laying of ductile iron pipe 100mm dia. with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces (measure separately), including testing and commissioning complete all as specified and as directed.
M&L brick masonry valve chamber of size 750x750x750mm including necessary excavation, PCC foundation, brick work, plastering and MS sheet cover of 6mm thick including locking arrangement with two coats of red oxide primer and one coat of synthetic enamel paint of approved colour complete all as specified and as directed.
M&L for cutting existing steel tubing 100mm dia. for alterations or additions necessarily done in position with out taking down and inserting 'TEE' of size 100x100x100mm for tapping complete all as specified and as directed.
M&L galvanised iron strip 32x6mm size buried in ground/fixed to wall/ floor etc. complete all as specified and as directed.
S&F flanged end lift type foot valve 100mm dia. with brass strainer, suitable flanges, nuts, bolts, gaskets etc. complete all as specified and as directed.
Supply, install, testing and commissioning of monoblock pump set with minimum ratings as 15 HP, 70 Mtr head, discharge 1000 LPM with delivery size of 80mm bore, 415 Volts, 50 Hz, AC 3 Phase supply, electric driven, inclusive of air valve at delivery, pressure guage along with cabling by XLPE copper cables from starter to pump set with cable tray and PCC foundation complete all as specified and as directed.
S&F star delta starter for monoblock pump sets with fixing arrangement for capacity of 15 HP pump complete all as specified and as directed.
S&F digital type water meter (Electromagnetic type) flanged type, MS body, for smart metering, of high accuracy, robust designe, IP-67 enclosure, max flow 1500 lpm for residential water supply scheme for fixing to 80mm dia. GI/DI pipe line, with and inlussive of necessary nuts, bolts and washer for fixing, necssary excavation/retuning filling in, and connecting FRLS PVC insulated 3 core, PVC sheathed unarmoured copper wire drawn through GI pipe light grade 20mm dia. as required at site and making connection complete all as specified and as directed. Note: Excavation & earthwork, FRLS cable and GI pipe shall be measured and paid seperately.
S&L PVC insulated FRLS cable copper conductor 3 core 2.5 Sq.mm. PVC sheathed unarmoured drawn through GI pipe light grade complete all as specified and as directed. Note: Excavation & earthwork and GI pipe shall be measured and paid seperately.
M&L for GI pipe light grade 20mm dia. laid in trenches or fixed to wall complete all as specified and as directed.
EXTERNAL ELECTRIFICATION IN RESTRICTED AREA:
Supply, install, testing and commissioning outdoor type 11 KV, 630 Amps, 25 K/1 Sec, outdoor type, both sides extensible, internal are 21 KA/1 Sec floor mounted with internal copper bus bars, SF6 Insulated, completely motorised, 3 Way RMU consisting of 2 Nos. 630 Amps LBS & 1 No. 630 Amps VCBs with SACADA compatible Overload and earth fault protection relay, with all live parts, bus bars of RMU enclosed in tank to avoid multiple interconnections & sealed for life robotically for three sides and one side manual welded stainless steel tank Grade 304 of minimum 2mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62261-200 and with RMU complete with all accessories such as terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for load break switch ON/OFF, manometer as per with IEC standards 62271-200, and RMU with GI enclosure (120/275 GSM) with RAL 7032 paint and dual coat where top coat (80-100 microns) as PP along with epoxy/polyester hybrid/epoxy zinc rich primer having neutral salt spray hours as per IS-9227 i.e. 1440, including testing the RMU for internal arc for 21 KA/1 sec cable & tank with AFLR classifications, bidder shall provide type test report to prove compliance to the internal arc fault IAC-AFLR as per IEC 62271-200 with No. of electrical operating cycles as 2000 and short circuit cycles as 50 and with RMU with Integrated bus connected metering cubicle consisting of MFM 0.5 class, PT, FRTU, CT Rating: 50-25/1A 5P10 including inbuilt battery along with battery charger and maintenance free batteries of capacity not less than 20 AH to give backup up to 05 hours with 10 open/close operations, complete all as specified and as directed.
Supply, installation, testing and commisioning distribution transformer step down 11//0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% cotinuous rating of 400 KVA outdoor type confirming to IS 1180, EE level-II with and including the following: (a) Lifting lugs/ hooks for transformer and tank (b) Earthing terminal rating and diagram plate (c) Air release device (d) Oil filling inlet pipe with plug (e) Drain outlet pipe with brass gate valve with dummy plug (f) Conservator with level guage (g) Silica gel breather (h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335 (j) Type of connection: Delta/Star (k) Type of cooling: ONAN (l) Vector Group: DYN 11 (m) Type of connecting arrangement: Cable termination boxes on both HT and LT side (n) Temperature rise over an ambient of 50 degree centigrage maximum (o) All necessary arrangements with devices for measuring the temperature of core, winiding and oil (p) In addition to the above all standard fittings shall be provided as per IS norms
S&F the following components for bus bar trunking system for the complete building power supply duly insulated three phase of rating 250 Amps, 25 KA, 415 Volts aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 250 Amps, 25 KA 4 Pole with rotary handle, termination links of building complete all as specified and as directed:
Straight feeder
Flange end
End Cover
Brackets
Springs Hangers
Fire barrier complete for BBTs required
Adaptor box as required
Copper braided flexible complete for BBT as required
External GI earth strip 32x6mm size
63 Amps 4 Pole lightning trunking
Flexible elbow as required at site
Horizontal elbow as required
MS 100 Amps centre feed Unit IP 55
63 Amps tap off box for MCB as required
End cover for 63 Amps feeder
MS Sleeve IP 55
MS plug point gasket IP 55
Suspension bracket all as required
125 Amps tap off box with MCCB 63 Amps, 4 Pole, 16 KA
250 Amps, 25 KA, 4 Pole MCCB
S&F the following components for bus bar trunking system for the complete building power supply duly insulated three phase of rating 160 Amps, 25 KA, 415 Volts aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 160 Amps, 25 KA, 4 Pole with rotary handle, termination links of building complete all as specified and as directed:
Straight feeder
Flange end
End Cover
Brackets
Springs Hangers
Fire barrier complete for BBTs required
Adaptor box as required
Copper braided flexible complete for BBT as required
External GI earth strip 32x6mm size
63 Amps 4 Pole lightning trunking
Flexible elbow as required at site
Horizontal elbow as required
MS 100 Amps centre feed Unit IP 55
63 Amps tap off box for MCB as required
End cover for 63 Amps feeder
MS Sleeve IP 55
MS plug point gasket IP 55
Suspension bracket all as required
125 Amps tap off box with MCCB 63 Amps, 4 Pole, 16 KA
160 Amps, 25 KA, 4 Pole MCCB
S&F integral LED street light luminaire 40 Watts IP 65, BEE 3 star rating, comprising of epoxy powder coated, pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting from loop-in loop-out box complete including installation and testing complete all as specified and directed.
Supply, install, test and commissioning of solar street lighting luminaire of capacity 60 Watts, BEE 3 star rating, microprocessor based with self contained solution i.e. light on/off controlled by automatic daylight sensing including earthwork excavation, removal of soil and PCC 1:2:4 type B1 as in filling/foundation for fixing of pole not less than 6m height, with IP 65 protection consisting of the following complete all as specified and as directed: (a) Solar panel with polypropylene silicon cells (b) PVC coated galvanised pole of 6m long of 4mm wall thickness (c) Solar panel 100 Wp capacity (d) LED 60 Watts Luminiaire in powder coated aluminium housing
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, combi-climate cable glands of IP 66/IP 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, ‘C’ Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. complete all as specified and directed.
S&F time switch 415 Volts, single phase of max 20 Amps rated, with contactor fitting inside steel enclosure complete all as specified and as directed.
S&F sheet metal enclosure including fixing incoming and outgoing cables with bus bar for cable connection tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 Volts, 100 Amps capacity complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed. Incoming: (a) MCCB 63 Amps, 25 KA-01 No. Outgoing: (a) MCB TP 32 Amp 'C' curve, 16 KA-03 Nos. (b) MCB SPN 32 Amps 'C' curve-02 Nos. (c) LED Indicating lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, of following sizes complete all as specified and as directed.
3 core 185 Sq.mm.
3 core 150 Sq.mm.
3 core 95 Sq.mm.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed:
3½ core 400 Sq.mm.
3½ core 240 Sq.mm.
3½ core 120 Sq.mm.
3½ core 70 Sq.mm.
4 core 16 Sq.mm.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq.mm. complete all as specified and as directed.
Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts, 1000 Amps capacity as per IS-8623 complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed: Incoming: (a) ACB 4 Pole, 415 Volts, 50 KA (ICS=ICU=ICW/1 Sec), with microprocessor release (EDO type) of capacity 630 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes-01 No. Outgoing: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 250 Amps capacity, 36 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-03 Nos. (b) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 160 Amps capacity, 36 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-03 Nos. (c) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breaker (d) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker-04 Sets
Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts, 500 Amps capacity as per IS-8623 complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed: Incoming: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 315 Amps capacity, 36 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-01 No. Outgoing: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 250 Amps capacity, 36 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-02 Nos. (b) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 63 Amps capacity, 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-02 Nos. (c) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breaker (d) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker-03 Sets
Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts, 400 Amps capacity as per IS-8623 complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed: Incoming: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 160 Amps capacity 36 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-01 No. Outgoing: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 63 Amps capacity, 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-05 Nos. (b) MCB, AC, 3 Phase, 415 Volts, 50 Hz, 4 Pole, 32 Amps capacity, 'C' curve, 16 KA with adjustable type thermal and magnetic setting release-05 Nos. (c) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breaker (d) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker-05 Sets
Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts, 100 Amps capacity as per IS-8623 complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed: Incoming: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 63 Amps capacity 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-01 No. Outgoing: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 63 Amps capacity 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-02 Nos. (b) MCB, AC, 3 Phase, 415 Volts, 50 Hz, 4 Pole, 32 Amps capacity, 'C' curve, 16 KA with adjustable type thermal and magnetic setting release-02 Nos. (c) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breaker (d) LED indicating lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breaker
M&L earth continuity conductor or main earthing lead made of galvanised iron strip 32X6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI pipe for earthing etc. complete all as specified and as directed.
Boring of holes under road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe 150mm dia. suitable for 0.4 mpa working pressure complete all as specified and as directed.
EXTERNAL ELECTRIFICATION IN UNRESTRICTED AREA:
Supply, install, testing and commissioning outdoor type 11 KV, 630 Amps, 25 K/1 Sec, outdoor type, both sides extensible, internal are 21 KA/1 Sec floor mounted with internal copper bus bars, SF6 Insulated, completely motorised, 3 Way RMU consisting of 2 Nos. 630 Amps LBS & 1 No. 630 Amps VCBs with SACADA compatible Overload and earth fault protection relay, with all live parts, bus bars of RMU enclosed in tank to avoid multiple interconnections & sealed for life robotically for three sides and one side manual welded stainless steel tank Grade 304 of minimum 2mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62261-200 and with RMU complete with all accessories such as terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for load break switch ON/OFF, manometer as per with IEC standards 62271-200, and RMU with GI enclosure (120/275 GSM) with RAL 7032 paint and dual coat where top coat (80-100 microns) as PP along with epoxy/polyester hybrid/epoxy zinc rich primer having neutral salt spray hours as per IS-9227 i.e. 1440, including testing the RMU for internal arc for 21 KA/1 sec cable & tank with AFLR classifications, bidder shall provide type test report to prove compliance to the internal arc fault IAC-AFLR as per IEC 62271-200 with No. of electrical operating cycles as 2000 and short circuit cycles as 50 and with RMU with Integrated bus connected metering cubicle consisting of MFM 0.5 class, PT, FRTU, CT Rating: 100-50/1A 5P10 including inbuilt battery along with battery charger and maintenance free batteries of capacity not less than 20 AH to give backup up to 05 hours with 10 open/close operations, complete all as specified and as directed.
Supply, install, testing and commissioning RMU of capacity 630 Amp, outdoor type 11 KV HT switchboard of type HWX made of CRCA of thickness 3.15mm and consisting of VCB totally enclosed and fully interlocked draw out type breaker as per IEC 622671-100/200 single break trip free breaker with motor operated spring charge mechanism mounted on a truck carriage complete with self contained fully interlocked rack in and rack out mechanism, breaker is featured with mechanical ON and OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 6 NO and 6 NC, breaker should have breaking capacity of 250 MVA for 3 Sec., with the unit panel completely consisting of 1 incomer cum outgoing panel with side entry cable box and the with the bus bar rating 630 Amp for complete switchgear along with all accessories comprising of the following/as specified hereunder complete all as specified and as directed: (a) Continuous high conductivity electrolytic copper bus bar, PVC sleeved insulated for full voltage, phase identification made at the end by colored tape, bus bar shall be mounted on integral seal off bushing and interconnection with electrolytic grade copper with joints silver plated. (b) Circuit breaker shall be mounted on a withdrawable truck which shall be horizontally draw out from service position to isolated position (c) Motorised Spring Charged Mechanism (d) Cast Resin Current Transformer, 11 KV, 50-25/1 Amps, 15 VA, Cl 5P10, Cl0.5-3 Nos. (e) Cast Resin Three phase Potential Transformer 11Kv/√3/110V/√3, 50VA, Cl 0.5 - 03 Nos with desired capacity PT Fuses Contd...
S&F the following components for bus bar trunking system for the complete building power supply duly insulated three phase of rating 250 Amps, 25 KA, 415 Volts aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 250 Amps, 25 KA 4 Pole with rotary handle, termination links of building complete all as specified and as directed:
Straight feeder
Flange end
End Cover
Brackets
Springs Hangers
Fire barrier complete for BBTs required
Adaptor box as required
Copper braided flexible complete for BBT as required
External GI earth strip 32x6mm size
63 Amps 4 Pole lightning trunking
Flexible elbow as required at site
Horizontal elbow as required
MS 100 Amps centre feed Unit IP 55
63 Amps tap off box for MCB as required
End cover for 63 Amps feeder
MS Sleeve IP 55
MS plug point gasket IP 55
Suspension bracket all as required
125 Amps tap off box with MCCB 63 Amps, 4 Pole, 16 KA
250 Amps, 25 KA, 4 Pole MCCB
S&F integral LED street light luminaire 40 Watts IP 65, BEE 3 star rating, comprising of epoxy powder coated, pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing complete all as specified and directed.
Supply, install, test and commissioning of solar street lighting luminaire of capacity 60 Watts, BEE 3 star rating, microprocessor based with self contained solution i.e. light on/off controlled by automatic daylight sensing including earthwork excavation, removal of soil and PCC 1:2:4 type B1 as in filling/foundation for fixing of pole not less than 6m height, with IP 65 protection consisting of the following complete all as specified and as directed: (a) Solar panel with polypropylene silicon cells (b) PVC coated galvanised pole of 6m long of 4mm wall thickness (c) Solar panel 100 Wp capacity (d) LED 60 Watts Luminiaire in powder coated aluminium housing
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, combi-climate cable glands of IP 66/IP 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, ‘C’ Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. complete all as specified and directed.
S&F time switch 415 Volts, single phase of max 20 Amps rated, with contactor fitting inside steel enclosure complete all as specified and as directed.
S&F sheet metal enclosure including fixing incoming and outgoing cables with bus bar for cable connection tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 Volts, 100 Amps capacity complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed. Incoming: (a) MCCB 63 Amps, 25 KA-01 No. Outgoing: (a) MCB TP 32 Amp, 16 KA-03 Nos. (b) MCB SPN 32 Amps-02 Nos. (c) LED Indicating lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 Volts grade, of following sizes complete all as specified and as directed.
3 core 185 Sq.mm.
3 core 150 Sq.mm.
3 core 95 Sq.mm.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and as directed:
3½ core 400 Sq.mm.
3½ core 240 Sq.mm.
3½ core 120 Sq.mm.
3½ core 70 Sq.mm.
4 core 16 Sq.mm.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq.mm. complete all as specified and as directed.
S&F for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq.mm. complete all as specified and as directed.
S&F cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sq.mm. complete all as specified and as directed.
Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts, 1200 Amps capacity as per IS-8623 complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed: Incoming: (a) ACB, 4 Pole, 415 Volts, 50 KA (ICS=ICU=ICW for 1 Sec), with microprocessor release (EDO type) of capacity 800 Amps, with adjustable type overload protection, short circuit protection, with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes-01 No. Outgoing: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 250 Amps, capacity 36 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-05 Nos. (b) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breaker (c) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker-04 sets
Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts, 400 Amps capacity as per IS-8623 complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed: Incoming: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 250 Amps capacity, 36 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-01 No. Outgoing: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 63 Amps capacity, 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-06 Nos. (b) MCB, AC, 3 Phase, 415 Volts, 50 Hz, 4 Pole, 32 A capacity, 16 KA with adjustable type thermal and magnetic setting release-04 Nos. (c) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breaker (d) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker-05 Sets
Supply, installation, testing and commissioning of LT FPB made out of CRCA sheet 3.15mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc. used are to be made of rust proof material including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 Volts, 100 Amps capacity as per IS: 8623 complete with powder coating, necessary internal electric connection as required and provision of the following complete all as specified and as directed: Incoming: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 63 Amps capacity 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-01 No. Outgoing: (a) MCCB, AC, 3 Phase, 415 Volts, 50 Hz, microprocessor release 4 Pole, 63 Amps capacity, 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release-02 Nos. (b) MCB, AC, 3 Phase, 415 Volts, 50 Hz, 4 Pole, 32 Amps capacity, 16 KA with adjustable type thermal and magnetic setting release-02 Nos. (c) Intelligent panel meter to measure voltage, current, frequency, power factor, KWH etc. with all connected CTs of each breaker (d) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker
M&L earth continuity conductor or main earthing lead made of galvanised iron strip 32X6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI pipe for earthing etc. complete all as specified and as directed.
Boring of holes under road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe 150mm dia. suitable for 0.4 mpa working pressure complete all as specified and as directed.
AREA DRAINAGE IN RESTRICTED AREA:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
M&L pre-cast RCC M-30 as in factory made cover slabs, set in cement mortar (1:4) including use and waste of form work complete all as specified and as directed.
AREA DRAINAGE IN UNRESTRICTED AREA:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
M&L pre-cast RCC M-30 as in factory made cover slabs, set in cement mortar (1:4) including use and waste of form work complete all as specified and as directed.
SEWAGE DISPOSAL IN RESTRICTED AREA:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
M&L pre-cast SFRC manhole cover slabs conforming to IS 12592-2002, set in cement mortar (1:4) including use and waste of form work complete all as specified and as directed.
M&L PVC coated chain link fencing made out of 3.10mm dia. galvanised iron wire of mesh 75mmx75mm size, made up to in to mattress or cages, straining and fixing to RCC posts fixed with MS flat and 3 Nos. of 10mm dia. TMT bars as line wire complete all as specified and as directed. Note: MS Flat & TMT bars will be measured and paid separately.
SEWAGE DISPOSAL IN UNRESTRICTED AREA:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
M&L pre-cast SFRC manhole cover slabs conforming to IS 12592-2002, set in cement mortar (1:4) including use and waste of form work complete all as specified and as directed.
M&L PVC coated chain link fencing made out of 3.10mm dia. galvanised iron wire of mesh 75mmx75mm size, made up to in to mattress or cages, straining and fixing to RCC posts fixed with MS flat and 3 Nos. of 10mm dia. TMT bars as line wire complete all as specified and as directed. Note: MS Flat & TMT bars will be measured and paid separately.
SEWAGE DISPOSAL E/M:
S&F MS pipe 150mm NB heavy duty duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and as directed.
Supply and laying 100mm dia. ductile iron pipe class K9, single socketed, suitable for 10.0 Kg/Sq.cm. pressure laid in trenches, wall, floor etc. complete all as specified and as directed.
M&L for rubber tyton joint suitable for 100mm dia. DI pipe including necessary connecting arrangements complete all as specified and as directed.
S&F ductile iron specials such as bends, elbows, reducers etc. (any type, radius and angle) tapers any type, tail piece (flanged/socketed/spigot) complete all as specified and as directed.
M&L brick masonry valve chamber of size 750x750x750mm including necessary excavation, PCC foundation, brick work, plastering and MS sheet cover of 6mm thick including locking arrangement with two coats of red oxide primer and one coat of synthetic enamel paint of approved colour complete all as specified and as directed.
Supply, installation, testing and commissioning of non-clogging submersible pump set 10 HP capacity electric driven with chrome steel impeller of min flow 1120 lpm, with head 20m inside raw sewage tank with float switch, lifting arrangement cabling, installation complete along with the basic requirement of motor protection, with electric starter panel and shall have automatic start-stop sensor device according to the levels in the sump with the reverse rotation system incorporated in the pump design to ensure that the pump does not start rotating in the reverse direction due to wrong electrical connection including all accessories complete all as specified and as directed. Note: The cost of starter panel, sensor and float switch shall be included in the unit rate.
Supply, installation, testing and commissioning of non-clogging submersible pump set 5 HP capacity electric driven with chrome steel impeller of min flow 100 lpm, head 20m inside raw sewage tank with float switch, lifting arrangement cabling, installation complete along with the basic requirement of motor protection, with electric starter panel and shall have automatic start-stop sensor device according to the levels in the sump with the reverse rotation system incorporated in the pump design to ensure that the pump does not start rotating in the reverse direction due to wrong electrical connection including all accessories complete all as specified and as directed. Note: The cost of starter panel, sensor and float switch shall be included in the unit rate.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3½ core 35 Sq.mm. complete all as specified and as directed:
M&L PVC insulated flat submersible copper cable of size 3 core 6 Sq.mm. complete all as specified and as directed.
M&L PVC insulated flat submersible copper cable of size 3 core 4 Sq.mm. complete all as specified and as directed.
Supply and fix sheet metal enclosure indoor type feeder panel with provision of fixing incoming and outgoing cables with bus bar and cable connection to tinned copper bus bar with insulators suitable for Three Phase and four wire LT AC, 50 Hz, 415 Volts, 100 Amps capacity complete with powder coating, necessary internal electric connection as required and including provision of the following all as specified and as directed: Incoming: (a) MCCB 63 Amps, 25 KA-01 No. Outgoing: (a) MCB TP 32 Amp, 16 KA-03 Nos. (02 Nos. for 10 HP pumps + 01 No. spare) (b) MCB TP 16 Amp, 16 KA-03 Nos. (02 Nos. for 5 HP pumps + 01 No. spare) (c) LED indicating lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases-03 Nos. (d) Multifunctional digital Meter
Boring of holes under road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe 150mm dia. suitable for 0.4 mpa working pressure complete all as specified and as directed.
ROAD/PATH/CULVERT IN RESTRICTED AREA:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
M&L pre-cast cement concrete block masonry as in kerb stones with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
M&L granular sub base (GSB) with grading V of 200mm thick compacted thickness (Laid in two layers of 100mm each, compacted seperately) confirming to grading as specified, spread, rolled & consolidated to required gradient and camber complete using necessary mechanical paver/grader & vibratory soil compacter of capacity 8-10 Ton complete all as specified and as directed. Notes: 1. Pavement shall be made for solid quantity arrived after consolidation. 2. Compaction of granular sub base filling shall be carried out under optimum moisture condition to achieve 98.50% modified density. 3. Curing shall be carried out as per IRC recommendations. 4. Before execution of this item the approved material obtained from outside MD land shall be tested/Checked for suitability to use. 5. Contractor shall use vibratory earth compactor in lieu of power roller to achieve 98.50% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. 6. GSB shall be as per MORTH specification as detailed in particular specification.
M&L painting lines, dashes, arrows, letters etc. on roads surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement up to 160oC, including cleaning & drying the road surfaces to ensure dust, oil, grease & moisture free surface before applying paint complete all as specified and as directed.
ROAD/PATH/CULVERT IN UNRESTRICTED AREA:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
M&L pre-cast cement concrete block masonry as in kerb stones with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
M&L granular sub base (GSB) with grading V of 200mm thick compacted thickness (Laid in two layers of 100mm each, compacted seperately) confirming to grading as specified, spread, rolled & consolidated to required gradient and camber complete using necessary mechanical paver/grader & vibratory soil compacter of capacity 8-10 Ton complete all as specified and as directed. Notes: 1. Pavement shall be made for solid quantity arrived after consolidation. 2. Compaction of granular sub base filling shall be carried out under optimum moisture condition to achieve 98.50% modified density. 3. Curing shall be carried out as per IRC recommendations. 4. Before execution of this item the approved material obtained from outside MD land shall be tested/Checked for suitability to use. 5. Contractor shall use vibratory earth compactor in lieu of power roller to achieve 98.50% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. 6. GSB shall be as per MORTH specification as detailed in particular specification.
M&L painting lines, dashes, arrows, letters etc. on roads surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement up to 160oC, including cleaning & drying the road surfaces to ensure dust, oil, grease & moisture free surface before applying paint complete all as specified and as directed.
RETAINING WALL/COMPOUND WALL/GATE:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
S&F punched tape concertina coil 610mm dia. as per IS-4454 with galvanised coating and punched tape material as per IS-513 deep drawn quality with galvanising coating having medium barbs (Bars length: 24+1mm, pitch between two barbs 35+1mm) fixed in position and secured to both sides of shaped angle iron post, stretched to a length of 6m to achieve 610mm dia., weighing 9 Kg (+5% with out handles and spikes) as in fencing to steel post and to another coil/MS ribs including fixing with special galvanised fasteners such as 'J' clips, 'C' clips, 'U' clips complete all as specified and as directed. Note: The length of the compound wall on which the concertina coil has been stretched shall be measured and paid.
RAIN WATER HARVESTING IN RESTRICTED AREA:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
RAIN WATER HARVESTING IN UNRESTRICTED AREA:
M&L pre-cast cement concrete block masonry with solid PCC blocks of grade C5 conforming to IS-2185 Part-I, in CM 1:6, exc. 10cm in width and setting in mortar complete all as specified and as directed.
FIRE FIGHTING IN RESTRICTED AREA:
S&F MS flanged pipe 100mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed.
M&L galvanised iron strip 32x6mm size buried in ground/fixed to wall/ floor etc. complete all as specified and as directed.
S&F single sided LED signage with buit in battery back-up for 2 hours of single 'EXIT' of color green suitable for operating voltage of 230 Volts, 50 Hz complete all as specified and as directed.
S&F 63mm dia. gun metal branch pipe with 12.5mm nozzle conforming to IS-903 complete all as specified and as directed.
S&F hose box for keeping 2 Nos. hose pipe of length 15 meter each, branch pipe, nozzle, coupling etc. made out of 2mm thick MS sheet complete all as specified and as directed.
FIRE FIGHTING IN UNRESTRICTED AREA:
S&F MS flanged pipe 100mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed.
M&L galvanised iron strip 32x6mm size buried in ground/fixed to wall/ floor etc. complete all as specified and as directed.
S&F single sided LED signage with buit in battery back-up for 2 hours of single 'EXIT' of color green suitable for operating voltage of 230 Volts, 50 Hz complete all as specified and as directed.
S&F 63mm dia. gun metal branch pipe with 12.5mm nozzle conforming to IS-903 complete all as specified and as directed.
S&F hose box for keeping 2 Nos. hose pipe of length 15 meter each, branch pipe, nozzle, coupling etc. made out of 2mm thick MS sheet complete all as specified and as directed.
FIRE ALARM IN RESTRICTED AREA:
Supply, fixing and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables with stranded copper conductor of size 2 core 1.5 Sq.mm., 1100 Volts grade complete all as specified and as directed.
FIRE ALARM IN UNRESTRICTED AREA:
Supply, fixing and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables with stranded copper conductor of size 2 core 1.5 Sq.mm., 1100 Volts grade complete all as specified and as directed.
AVIATION LIGHT IN RESTRICTED AREA:
S&F aviation obstruction light LED type filament-less bulb with 10 Watt bulb including standard fixing arrangements complete all as specified and as directed.
S&F PVC insulated PVC sheathed armoured cable LT 1100 Volts grade with copper conductor of size 3 core 2.5 Sq.mm. multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps, spacers, bolts, nuts etc. complete all as specified and as directed.
S&F time switches 250 Volts single Phase of 20 Amp rating with contactor fitted inside the steel enclosure complete all as specified and as directed.
AVIATION LIGHT IN UNRESTRICTED AREA:
S&F aviation obstruction light LED type filament-less bulb with 10 Watt bulb including standard fixing arrangements complete all as specified and as directed.
S&F PVC insulated PVC sheathed armoured cable LT 1100 Volts grade with copper conductor of size 3 core 2.5 Sq.mm. multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps, spacers, bolts, nuts etc. complete all as specified and as directed.
S&F time switches 250 Volts single Phase of 20 Amp rating with contactor fitted inside the steel enclosure complete all as specified and as directed.
LIGHTNING PROTECTION IN RESTRICTED AREA:
S&F single pointed air terminal aluminium rod 12mm dia. 300mm long with aluminium box plate of size of 125x125x10mm including necessary fasteners fixed for lighting protection with necessary connections to earthing etc. complete all as specified and as directed.
S&F horizontal roof conductor and down conductor of size 25x3.15mm aluminium strip fixed to walls/columns/projections/roof including porcelain blocks/DMC insulator spaced at 1m interval complete all as specified and as directed.
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws etc. complete all as specified and as directed.
M&L fixing earth continuity or main earthing lead made of GI Strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
LIGHTNING PROTECTION IN UNRESTRICTED AREA:
S&F single pointed air terminal aluminium rod 12mm dia. 300mm long with aluminium box plate of size of 125x125x10mm including necessary fasteners fixed for lighting protection with necessary connections to earthing etc. complete all as specified and as directed.
S&F horizontal roof conductor and down conductor of size 25x3.15mm aluminium strip fixed to walls/columns/projections/roof including porcelain blocks/DMC insulator spaced at 1m interval complete all as specified and as directed.
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia. 25mm long hexagonal head screws etc. complete all as specified and as directed.
M&L fixing earth continuity or main earthing lead made of GI Strip 32x6mm size, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
HOT WATER SUPPLY IN RESTRICTED AREA:
Supply, Install, testing and commissioning of geyser 15 Litres capacity electric driven (Single Phase), 5 Star rated with hot/cold flexible water pipe and including all acessories complete all as specified and as directed.
HOT WATER SUPPLY IN UNRESTRICTED AREA:
Supply, Install, testing and commissioning of geyser 15 Litres capacity electric driven (Single Phase), 5 Star rated with hot/cold flexible water pipe and including all acessories complete all as specified and as directed.
SOLAR POWER INVERTER IN RESTRICTED AREA:
Supply, fixing, testing and commissioning of Solar Panel Powered Inverter (Sine wave) with battery backup for 8 hours of capacity 3 KW (Single phase 230 Volt, 50 Hz, AC supply) complete (Off grid Type) with and inclusive of all the electrical and mechanical accessories & stand for inverter and batteries complete all as described and as directed by the Engineer-in-Charge.
Supply, fixing, testing and commissioning of Solar Panel Powered Inverter (Sine wave) with battery backup for 8 hours of capacity 2 KW (Single phase 230 Volt, 50 Hz, AC supply) complete (Off grid Type) with and inclusive of all the electrical and mechanical accessories & stand for inverter and batteries complete all as described and as directed by the Engineer-in-Charge.
SOLAR POWER INVERTER IN UNRESTRICTED AREA:
Supply, fixing, testing and commissioning of Solar Panel Powered Inverter (Sine wave) with battery backup for 8 hours of capacity 3 KW (Single phase 230 Volt, 50 Hz, AC supply) complete (Off grid Type) with and inclusive of all the electrical and mechanical accessories & stand for inverter and batteries complete all as described and as directed by the Engineer-in-Charge.
Supply, fixing, testing and commissioning of Solar Panel Powered Inverter (Sine wave) with battery backup for 8 hours of capacity 2 KW (Single phase 230 Volt, 50 Hz, AC supply) complete (Off grid Type) with and inclusive of all the electrical and mechanical accessories & stand for inverter and batteries complete all as described and as directed by the Engineer-in-Charge: Notes for Item Nos.287 to 290: 1. Solar panel of specification 320 WP (minimum) polycrystalline type shall be provided. 2. Inverter and battery backup shall be placed near lift operator room or near lift store room. 3. Tubular battery of 12 Volt, 150 AH of sufficient quantity to be provided and rate quoted shall be deemed to be included the cost of battery. 4. 15 Amps switch socket combination with necessary manual changeover switch 32 Amps, single phase, 240 Volts to be provided near inverter for switching on to normal electrical supply incase solar system fails. 15 Amps SSC shall be paid through under relevant item in Internal Electrification schedule and cost for change over switch shall be deemed to be included in the rate quoted. 5. Solar inverter supply shall feed the supply to light fittings of ground floor parking area, building security lights, passage lights of each floor, staircase lights of each floor and security lights provided in the roof top of the building. 6. Sub main wiring from Inverter to MCB DB of each floor and point wiring for parking area light, security lights fixed in the building, light fittings in passage of each floor and staircase shall be measured under relevant items under Internal Electrification schedule. 7. Before carrying out the work, the contractor shall submit wiring diagram of the Solar Panel Powered Inverter for approval by the Engineer-in-Charge.
DG SET IN RESTRICTED AREA:
Supply, installation, testing and commissioning of silent engine generating set with acoustic enclosure as per CPCB norms 415 volts 100 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/2613/5000 with and including the following:
(A) Alternator: Standard design alternator rated at 100 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3-phase 4 - wire 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722.
(i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% (v) Frequency regulation +/- 1%
(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
(i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/frequency regulation, Fuel filters, Fuel hoses. (vi) Lub oil System: Lubricating oil filter, Lubricating oil pump (vii) Air Intake System: Air intake Manifold, Air cleaner dry type (viii) Governor: Electronic Governor (ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator
(x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch handling and operation. Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
(xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine (xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms
(C) AMF Panel : Factory made inbuilt type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 Phase 4 wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 100 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 Pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, KW, KWH, pf, temperature, battery voltage etc.
(D) Acoustic Enclosure: Manufactured by OEM suitable for 100 KVA DG Set (i) NAL approved as per CPCB (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board. (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Construction details/specification are as follows: (a) Outer body: CRCA sheet of 1.6mm thick (b) Doors: CRCA sheet of 1.6mm thick (c) Sound Insulation: As per OEM Norms (v) The acoustic should be composite in construction and fully assembled integral unit (vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform (vii) The DG Set should be provided with external emergency stop push button (viii) The enclosure should be suitably illuminated by LED lamp fittings (ix) The noise level should be 75 dba at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen Set Green. The base frame should be painted with epoxy based black shade
DG SET IN UNRESTRICTED AREA:
Supply, installation, testing and commissioning of silent engine generating set with acoustic enclosure as per CPCB norms 415 volts 160 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/2613/5000 with and including the following:
(A) Alternator: Standard design alternator rated at 160 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3-phase 4 - wire 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722.
(i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% (v) Frequency regulation +/- 1%
(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
(i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/frequency regulation, Fuel filters, Fuel hoses. (vi) Lub oil System: Lubricating oil filter, Lubricating oil pump (vii) Air Intake System: Air intake Manifold, Air cleaner dry type (viii) Governor: Electronic Governor (ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator
(x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch handling and operation. Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
(xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine (xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms
(C) AMF Panel : Factory made inbuilt type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 Phase 4 wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 160 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 Pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, KW, KWH, pf, temperature, battery voltage etc.
(D) Acoustic Enclosure: Manufactured by OEM suitable for 100 KVA DG Set (i) NAL approved as per CPCB (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board. (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Construction details/specification are as follows: (a) Outer body: CRCA sheet of 1.6mm thick (b) Doors: CRCA sheet of 1.6mm thick (c) Sound Insulation: As per OEM Norms (v) The acoustic should be composite in construction and fully assembled integral unit (vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform (vii) The DG Set should be provided with external emergency stop push button (viii) The enclosure should be suitably illuminated by LED lamp fittings (ix) The noise level should be 75 dba at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen Set Green. The base frame should be painted with epoxy based black shade
(E) The coated rate includes excavation, removing of soft soil and PCC, cement concrete foundation, filling and mass concrete type B2 (1:2:4) using 40mm graded aggregate of size not less than as per OEM drawing for placing of DG Set complete all as specified and directed.
Supply, installation, testing and commissioning of silent engine generating set with acoustic enclosure as per CPCB norms 415 volts 30 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/2613/5000 with and including the following:
(A) Alternator: Standard design alternator rated at 30 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3-phase 4 - wire 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722.
(i) Insulation class-'H‘ (ii) Temperature rise Class-'H‘ (iii) Excitation: Self Excited (iv) Regulation Performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% (v) Frequency regulation +/- 1%
(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
(i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/frequency regulation, Fuel filters, Fuel hoses. (vi) Lub oil System: Lubricating oil filter, Lubricating oil pump (vii) Air Intake System: Air intake Manifold, Air cleaner dry type (viii) Governor: Electronic Governor (ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator
(x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch handling and operation. Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
(xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine (xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms
(C) AMF Panel : Factory made inbuilt type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 Phase 4 wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 30 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 Pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, KW, KWH, pf, temperature, battery voltage etc.
(D) Acoustic Enclosure: Manufactured by OEM suitable for 100 KVA DG Set (i) NAL approved as per CPCB (ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board. (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Construction details/specification are as follows: (a) Outer body: CRCA sheet of 1.6mm thick (b) Doors: CRCA sheet of 1.6mm thick (c) Sound Insulation: As per OEM Norms (v) The acoustic should be composite in construction and fully assembled integral unit (vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform (vii) The DG Set should be provided with external emergency stop push button (viii) The enclosure should be suitably illuminated by LED lamp fittings (ix) The noise level should be 75 dba at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen Set Green. The base frame should be painted with epoxy based black shade
LIFTS IN RESTRICTED AREA:
LIFTS IN UNRESTRICTED AREA:
ARBORICULTURE IN RESTRICTED AREA:
Supply and plantation of Ravi/Neem (height of plant not less than 2.0m above ground level) including preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed.
Supply and plantation of Jamun (height of plant not less than 1.5m above ground level) including preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed.
Supply and plant Bermuda grass by piece turfing including preparation of earth to 30cm depth using pesticides and manures complete all as specified and as directed. Note for Item Nos.302 to 304: Supply only fertile earth, cow dung, manure, pesticides etc. will measured separately.
Supply only approved good quality fertile earth suitable for carpet grass all as specified.
Supply only approved manure (cow dung) best quality suitable for arboriculture all as specified.
Supply only approved vermi compost of the best quality all as specified.
ARBORICULTURE IN UNRESTRICTED AREA:
Supply and plantation of Ravi/Neem (height of plant not less than 2.0m above ground level) including preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed.
Supply and plantation of Jamun (height of plant not less than 1.5m above ground level) including preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed.
Supply and plant Bermuda grass by piece turfing including preparation of earth to 30cm depth using pesticides and manures complete all as specified and as directed. Note for Item Nos.308 to 310: Supply only fertile earth, cow dung, manure, pesticides etc. will measured separately.
Supply only approved good quality fertile earth suitable for carpet grass all as specified.
Supply only approved manure (cow dung) best quality suitable for arboriculture all as specified.
Supply only approved vermi compost of the best quality all as specified.
DEMOLITION AND DISMANTLING:
Taking down UG cable of soze 3 core 16 Sq.mm. from main DB to FP box complete all as specified and as directed.
Taking down main MCB distribution boards of any description with MCBs complete all as specified and as directed.
Taking down gate valves of any size/description complete all as specified and as directed.
EARTH WORK IN RESTRICTED AREA:
Removal of excavated surplus soil outside MoD land complete all as specified and as directed.
EARTH WORK IN UN RESTRICTED AREA:
Removal of excavated surplus soil outside MoD land complete all as specified and as directed.
SCHEDULE 'A' PART-XVIII: (MAINTENANCE OF ARBORICULTURE IN RESTRICTED AREA): M&L for maintenance of arboriculture as provided under Item Nos.302 to 304 by weeding housing saucer melding once in every 15 days including planting new plants/grass of same spices and height if required with out any extra cost to the department for a period of TWENTY FOUR MONTHS complete all as specified and as directed. Note: Rate quoted shall be deemed to include for all the labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading/spraying organic manure, chemical fertilizers, pesticides to the required extent complete all as specified and directed.
SCHEDULE 'A' PART-XIX: (MAINTENANCE OF ARBORICULTURE IN UNRESTRICTED AREA): M&L for maintenance of arboriculture as provided under Item Nos.308 to 310 by weeding housing saucer melding once in every 15 days including planting new plants/grass of same spices and height if required with out any extra cost to the department for a period of TWENTY FOUR MONTHS complete all as specified and as directed. Note: Rate quoted shall be deemed to include for all the labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading/spraying organic manure, chemical fertilizers, pesticides to the required extent complete all as specified and directed.
SCHEDULE 'A' PART-XX: Comprehensive maintenance of Electrically Operated Lifts in Restricted Area for the First Year after Defect Liability Period
Comprehensive mainenance of 05 No Electrically operated lifts (8 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 03 No Electrically operated lifts (13 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of liftduring 1st year after expiry of Defect liability period all as specified and directed.
SCHEDULE 'A' PART-XXI: Comprehensive maintenance of Electrically Operated Lifts in Unrestricted Area for the First Year after Defect Liability Period
Comprehensive mainenance of 02 No Electrically operated lifts (8 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 01 No Electrically operated lifts (13 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 06 No Electrically operated lifts (8 passenger) passengers to serve stilt plus seven upper floors complete including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 03 No Electrically operated lifts (13 passenger) passengers to serve stilt plus seven upper floors complete including ARD and all connected components of lift during 1st year after expiry of Defect liability period all as specified and directed.
SCHEDULE 'A' PART-XXII: Comprehensive maintenance of Electrically Operated Lifts in Restricted Area for the Second Year after Defect Liability Period
Comprehensive mainenance of 05 No Electrically operated lifts (8 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 2nd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 03 No Electrically operated lifts (13 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of liftduring 2nd year after expiry of Defect liability period all as specified and directed.
SCHEDULE 'A' PART-XXIII: Comprehensive maintenance of Electrically Operated Lifts in Unrestricted Area for the Second Year after Defect Liability Period
Comprehensive mainenance of 02 No Electrically operated lifts (8 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 2nd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 01 No Electrically operated lifts (13 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 2nd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 06 No Electrically operated lifts (8 passenger) passengers to serve stilt plus seven upper floors complete including ARD and all connected components of lift during 2nd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 03 No Electrically operated lifts (13 passenger) passengers to serve stilt plus seven upper floors complete including ARD and all connected components of lift during 2nd year after expiry of Defect liability period all as specified and directed.
SCHEDULE 'A' PART-XXIV: Comprehensive maintenance of Electrically Operated Lifts in Restricted Area for the Third Year after Defect Liability Period
Comprehensive mainenance of 05 No Electrically operated lifts (8 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 3rd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 03 No Electrically operated lifts (13 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of liftduring 3rd year after expiry of Defect liability period all as specified and directed.
SCHEDULE 'A' PART-XXV: Comprehensive maintenance of Electrically Operated Lifts in Unrestricted Area for the Third Year after Defect Liability Period
Comprehensive mainenance of 02 No Electrically operated lifts (8 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 3rd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 01 No Electrically operated lifts (13 passenger) passengers to serve stilt plus nine upper floors complete including ARD and all connected components of lift during 3rd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 06 No Electrically operated lifts (8 passenger) passengers to serve stilt plus seven upper floors complete including ARD and all connected components of lift during 3rd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of 03 No Electrically operated lifts (13 passenger) passengers to serve stilt plus seven upper floors complete including ARD and all connected components of lift during 3rd year after expiry of Defect liability period all as specified and directed.
(viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personnel. The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work Order No I.
KBPL AND REPL (JV)
B L Mehta Constructions Pvt Ltd
SHRADHA SABOORI PROJECTS (INDIA) PVT LTD
KEC International Limited
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid