Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC NAYABASTI KAJI PARA ROAD PO BARRACKPORE DIST 24 PARGANAS NORTH WEST BENGAL | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹44.6 L+₹4.6 L (11.4%)Rejected-Finance RAMAKRISHNA COLONY PO MAJHIPARA DIST 24 PARGANAS NORTH PIN 743145 STATE WEST BENGAL | 24 PARAGANAS NORTH | WEST BENGAL | 743145 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹45.6 L+₹5.6 L (14.1%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹45.8 L+₹5.8 L (14.6%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹46.6 L+₹6.6 L (16.5%)Rejected-Finance ANAND GUJARAT 388001 | ANAND | GUJARAT | 388001 | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹40.1 L
EMD Value
₹80,200
Closing Date
22 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
PROVN OF LADIES TOILET, PROVN OF TRG SHED, PROVN OF STEEL FIRE CHECK DOOR AND SPL REPAIR TO STEEL TUBULAR POLES, HIGH MAST POLE, SERVICE CONNECTION AND CONNECTED ACCESSORIES AT BARRACKPORE UNDER GE BARRACKPORE
2021_MES_482308_1
8573/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹80,200
Yes
29 Dec 2021
18 Oct 2021
25 Nov 2021
18 Oct 2021
22 Nov 2021
30 Oct 2021
60 days
Amount
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed
Excavating over areas, not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes, foundation for manhole and laying under ground cable, foundation and erection of poles and stays etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr and not exceeding 3mtr in depth for foundation or for shafts, well, cesspits, pier holes, foundation for manhole and laying under ground cable, foundation and erection of poles and stays etc and getting out in soft/loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, iln layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
M&L for approved earth filling, earth obtained from out side of Defence land to a distance exceeding 1.5 Km upto total distance 5 Km and depositing where directed and spreading and levelling in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate), as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in copping of manholes / drains, benching and channel of manhole / drains, and also for bed blocks for embeddings MS rungs of manhole / septic tank including necessary form work complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in foundations including rafts, footings, foundation beam, plinth beams, bases for columns etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab/slab of drain/manhole water tank/shelf, landing, cooking platform set in cement mortar (1:4) complete all as specified and directed. (NOTE: Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor & reinforcement shall be measured & paid Separately.)
M&L for cutting holes into or through brick walls in cement mortar built in cement mortar to a depth of embedded portion exceeding one brick but not exceeding two bricks for inserting hold fast and making good dismantled portion in cement concrete (1:2:4) Type B-1 as required complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for form work to sides of concrete foundation, footing, base of column, raft & plinth beam for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete, flat complete all as specified and directed.
M&L for formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.
S&F for 300 mm aluminum alloy, anodised, sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
M&L for TMT bars 8 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F for mild steel work in tubular trusses and purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
S&F for mild steel screw bolts (machine made) 16 to 20mm with hexagonal head at one end and screwed the other end, each screw end to be fitted with two washers and one hexagonal or square nut, length of bolts exceeding 30 cm complete all as specified and directed.
S&F for rolled mild steel as in joist, channel, angle or tee section, hold fast, wind ties, fixed independently with connecting base plate etc as in roof truss, purlin, rafter, strut bend to shape, holes drilled/notches cut out to received MS bolts and barbed wire, embedded to concrete including tarring to steel work embedded to concrete as in repair complete all as specified and directed.
S&F for steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed
S&F for steel windows with side hung shutters (gauged) including projection type hinges with steel handle, frame, steel peg stay, complete without glazing bars, dovetailed or welded to receive wiremesh complete all as specified and directed.
S&F for powder coated finish door galvanized steel flush fire doors two hours fire rating of size1.00 m wideX 2.50m height and tested in accordance with IS-3614 Part-2 & BS-476 Part-22, any Govt. Lab HR Govt. Door frames to be single rebate profile of 100X57 mm manufactured from 18 gauge galvanized steel, profile to have bending radius of 1.4 mm supplied in assembled form ready to install at site, door shutter in 46 mm thick manufactured from two 20 gauge galvanized steel sheets lock seam jointed at stile edges to form a double skin fully flush shell. In fill rock wool 96 Kg/m3 density or honey comb insulation material to be provided for structural rigidity & additional reinforcements & sound insulation for all hardware fixtures as required complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base to footpath, floor complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base of floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection & hard standing including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in flooring etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in floor finished the surface even and smooth without using extra cement complete all as specified and directed.
S&F for 3mm thick & 38 mm wide glass dividing strip, inserted in position as in floor complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 300 mmX7 mm thick or equivalent set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:4) complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls and roof with cement mortar (1:4) mixing with WPC as per manufacturer's instructions , finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying of 3 mm thick wall care putty on wall surface after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description complete all as specified and directed.
M&L for writing letters or figures (block, roman, italic or Indian) not exceeding 30cm high after cleaning and preparation of existing surfaces complete all as specified and directed.
M&L for writing stops, commas, short lines dashes, hyphens, bracket etc after cleaning the existing surface complete all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
S&F for brass chromium plated toilet paper holder fixed to walls with chromium plated brass screw complete all as specified and directed.
S&F for chromium plated health faucet with 15mm dia CP tube of 1.2 mtr long complete all as specified and directed.
S&F for 15 mm dia PVC connection pipe of length 450 mm with PTMT nuts complete all as specified and directed.
S&F for 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed complete all as specified and directed.
S&F for 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 25mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 20mm dia ball brass valves, high pressure, with polyethylene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F for 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection complete all as specified in SSR Part-I and directed.
S&F for vitreous china wash basin, white, flat back, size 630 X 450 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F for vitreous china wash down water closet pan (pedestal pattern) white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe & seat cover etc. including making good to floor complete all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F for 125mm dia grating with waste hole , fancy type, chromium plated complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor or fixed to wall complete all as specified and directed.
S&F for 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F for 110 mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F for 75 mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for LLDPE Septic Tanks, on lid LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC (1:4:8) below foundation, vent shaft, connection etc complete for fixing in any type of including connection etc vent shaft complete upflow filter including media etc for 10 users complete all as specified and directed.
M&L for soakage wells of size 1.2m dia X 1.5 m effective depth (internal), excavation in any type of soil, foundation in PCC (1:3:6) , walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/CWC complete with brick bats complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe 150 mm bore including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed.
M&L for 150mm bore salt glazed stone ware drain pipe grade 'A' laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One exhaust fan point controlled by one switch .
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per Item No.99.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
S&F for modular switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI marked complete all as specified and directed.
S&F for modular switch 10 Amps, single pole, 1 way, 1/2 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular socket 6/16 Amps, 6 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F for decorative box type 20 -22watt LED fitting with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC as approved for LED lamp as approved)
S&F for 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Make: Havells/Bajaj/Crompton as approved)
S&F for 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable with and including Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED as approved)
S&F for 70/72 watt LED security light fitting, with LED lamps in aluminium PDC housing, toughened glass cover with IP66 protection with minimum 4kv inbuilt surge protector and cable connection from looping box to light fitting and testing after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make:- Bajaj Cat No. BRTFG 72W LED V3/ Crompton cat No.CRP-409-70-57-SL-GL-NSG /Havells cat No.ENDURACITYLINERNEOSL70WLED757PASYBOTG as approved)
S&F for LED security light fitting of capacity 90 Watt LED street light fitting in aluminium PDC housing with LED lamp toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting and testing after and including removing of old unserviceable fittings complete all as specified and directed. (Make:-Crompton Greaves cat No.CRP-404-90-57-SL-GL-NSG /Havells cat No.ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO/Bajaj Cat No. DRTFG90WLEDIV2 or equivalent model of Surya as approved)
S&F for LED flood light fitting of capacity 120 Watt in aluminium PDC housing with LED lamp, toughened glass cover with IP66 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting at any height and testing after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make:-Crompton Cat ref No.LFLN-120-CDL/60-M /Havells cat No. JETAIRISFLS120WLED757APWBLTG /Bajaj Cat No.BJFL 120W LED I or equivalent model of Surya as approved)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer after and including taking down of existing unserviceable bracket complete all as specified and directed.
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 4 way for flush mounting with 100 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way / Hager cat No.VYS04D / L&T Cat No. DBSPN004GD as approved).
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F for MCB, SPN, 40 Amps to 63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised steel earth strip of size 32 x 6mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion complete all as specified and directed . (Galvanised strip upto 7.5m including testing consider in this item).
S&F for heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 240 sqmm, 3.5core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking out /down existing unserviceable cable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 185 sqmm, 3.5core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking out /down existing unserviceable cable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 95 sqmm, 3.5core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking out /down existing unserviceable cable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 70 sqmm, 3.5core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking out /down existing unserviceable cable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 35 sqmm, 3.5core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking out /down existing unserviceable cable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 2core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking out /down existing unserviceable cable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
M&L for 40mm dia pipe (medium grade) made of galvanised iron in any length including embedded in wall both ends duly welded mild steel hold fast at both ends of GI pipe including providing PCC work (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) complete all as specified and directed.
S&F for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified conforming to IS- 2317/1980 type 410 SP-31 (9 metres long) complete with cast iron base plate including staying the poles in a truly vertical position till the foundations are properly set, including painting to pole (inside & outside) with two coats of aluminium paint on exposed surfaces of poles and two coat of black bituminous paint on embedded portion after and including taking down old unserviceable pole of any description complete all as specified and directed. (Note: Excavation, foundation concrete and coping will be measured and paid separately)
S&F for hot press moulded SMC junction box of size 350mm X250mm X150mm hinged type with incoming and outgoing connector/terminals and comprising of MCB, SP, 6 Amps, 240V, 10KA, 'C' Series and including MS flat iron clamps of size 25X5mm thick -02 Nos, nuts, bolts & washers etc for fixing on PCC/Steel tubular pole/ wall surface etc after and including removing of old unserviceable item complete all as specified and directed. (Make:- Sintex/Hensel as approved)
M&L for PVC conduit heavy duty of size 20mm dia from looping box to street light connector, holding in MS clamp of size 25X2 mm thick at every one mtr used in each pole 04 Nos of clamps with necessary nut, bolts and washers etc including PVC sheathed three core multistranded copper conductor cable of size 1.5 sqmm from looping box to light fittings connector after and including taking down existing unserviceable one complete all as specified and directed.
Dismantling of old unserviceable ACSR conductor from existing pole of any type and including MS clamps, cross arm, nut, bolts and washers etc at any height and deposited to MES Store Yard Barrackpore complete all as specified and directed.
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 150mm dia for passing of UG cable complete all as specified and directed.
Supply, installation, testing and commissioning of factory made CPRI approved LT feeder pillar box (FPB) (out door type) of size 1200 mm (H) x 1200 mm (L) x 500 mm (W), suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection made, out of 3.15mm thick CRCA sheet and frame (all sides) made of angle iron (50mmX50mmX6mm) and flats (50 x 6 mm) duly epoxy powder coated (seven tank process) compartmentrised with rubber gasket, hinged doors with handle. FPB shall have front and rear opening, locking arrangement with control fuses see through glass arrangement, cable entry holes, aluminium busbar chamber, switch gear compartment, earthing terminals, affix danger notice plate, control copper wiring of adequate size and length etc the panel will be mounted on 50mm x 50mm x 6mm mild steel angle iron frame of height 45cm above floor level/ground level as per site requirement, and grouted legs below 45cm and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing PCC (1:3:6) type C-1 as foundation as per site requirement etc and drawing/circuit layout as approved with the following accessories after disconnecting of electric supply and earth conductor etc after and including dismantling of existing old unserviceable FPB with all accessories/mounting etc complete all as specified and directed :-
(a) MCCB 100 Amps, FP, 16 KA, 415 Volts, 50 Hz-01 No (b) MCCB 63 Amps, FP, 16 KA, 415 Volts, 50 Hz-01 No (c)Analogue time switch (daily time switch) with suitable power contactor 32 Amps, ML-2 type, 3 Phase, 415 Volts, auto/manual operating switches-01 No (d)Digital voltmeter with VSS-01 Set (e) Digital Ammeter with CTs and ASS-01 Set (f) LED phase indication lamps RYB -01 Set (g) Aluminium bus bar TPN 160 Amps (04 Nos) rating-01 Set (NOTE:The contractor shall submit drawings (general & circuit lay out drawings). Drawing shall be approved by GE after factory inspection by GE or Rep of GE before procurement)
M&L for steel tubular pole painting of any type/size/length and removing from existing pole painting by using wire brush and using with emery paper and cleaning with chemical agents after cleaning of steel tubular pole and GI brackets and cross arms etc applying one coat of red oxide primer and two coats of aluminium paint upto smooth finishing and painting upto 1.5 mtr at bottom layer by layer 30 cm by 30 cm with yellow and black paint and 15cm wide circle around the pole to be made by blue paint after black paint to satisfactorily by Engr-in-Charge and painting work carryout at any height and including marking of pole numbers to be marked with black paint over 20 cm yellow paint circle as directed and safety equipments & tools will be own arrangement and complete all as specified and directed. (Note: cost of painting material is deemed to be included in quoted rate )
M&L for PCC pole painting of any type/size/length and removing from existing pole painting by using wire brush and using with emery paper and cleaning with chemical agents after cleaning of PCC pole and GI brackets and cross arms applying one coat of primer and two coats of cement based paint upto smooth finishing and painting upto 1.2 mtr at bottom layer by layer 30 cm by 30 cm with yellow and black paint to satisfactorily by Engr-in-charge and painting work carryout at any height and including marking of pole numbers as directed and safety equipments & tools will be own arrangement complete all as specified and directed. (Note: cost of painting material is deemed to be included in quoted rate )
M&L for GI pipe 100mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection after and including taking down/up existing unserviceable pipe of any description complete all as specified and directed.
M&L for GI pipe 80mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection after and including taking down/up existing unserviceable pipe of any description complete all as specified and directed.
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection after and including taking down/up existing unserviceable pipe of any description complete all as specified and directed.
M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection after and including taking down/up existing unserviceable pipe of any description complete all as specified and directed.
M&L for providing cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface smooth complete all as specified and directed.
M&L for providing cement concrete (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling for poles complete all as specified and directed
S&F for mild steel cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide primer over two coats of aluminium paint after and including dismantling of existing unserviceable cross arm, angle and clamps etc complete all as specified and directed .
R.S. COMPANY
N S CONSTRUCTION
M/S H.P Singha
M/S RAJESH TRADING CO
BANERJEE ENTERPRISE
DAS ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .