| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹95.6 L
EMD Value
₹1.3 L
Closing Date
3 Aug 2021, 5:00 pmClosed
Executive Engineer
Jal shakti Division Thunag Distt Mandi HP
Providing laying, jointing testing of API pipe and laying, jointing testing of GI pipe in Rising main, Supply and errection of Centrifugal pumping machinery with allied accessories and L J T of G.I pipe 125mm dia feeder pipe
2021_HPIPH_50098_1
6303-70 dated 19/07/2021
Open Tender
Civil Works - Water Works
Item Rate
180 days
Baggachonagi
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
Yes
Executive Engineer
₹1.3 L
Yes
1 Sept 2021
20 Jul 2021
4 Aug 2021
20 Jul 2021
3 Aug 2021
20 Jul 2021
Amount
Excavation in foundation trenches (For pipes & pits upto all depths) in all classification of earth work such as pick work jumper work saturated soil including balling out water blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming dressing of sides leveling of bed to correct grade including shoring strutting planking timbering and dewatering where ever required stacking the useable/serviceable material/soil separately and after laying jointing and testing of pipes returning the useable soil in trenches in 15cm layers including consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil useable materials as directed within all leads/lifts including restoration of unmetalled surfaces to its original condition and including cost of diversion for traffic night signal fixing caution boards crossing over trenches for access to houses fencing etc. complete in all respect within all leads/lifts as per direction of the Engineer in charge .
Laying, jointing and testing of GMS tube in trenches of following dia meter including providing and fixing tube fitting such as bends, tees, air valves, unions and collars etc. including carraige of GI pipes as per direction and to the entire satisfaction of the Engineer-in-charge (earth work in trenches to be measured and paid for separately) in all leads and lifts.
125 mm dia (MG) ( Feeder Pipe)
Providing, welding, laying, testing and comissioning at site in trenches bevelled ended BIS marked API pipe as per ISO 3183-2007 latest with upto date amendments of following dia with steel grade 5L (std)x42, having wall thickness as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in a random lenghts of 5.0 to 7.0 mtr. The pipe ends shall be bevelled suitably for butt welding, including the cost of joining with butt welding confirming IS: 816-1969 or latest as applilcable with upto date amendments in three layers (leakproof) at site of work k with welding rods of standard make i.e. of Advani Overlikon/Over cords/s make conforming to IS 814-1991 including die penetration test at site of work & all allied accessories whatever required for welding at site including tail pieces, tees, bends of all degrees & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts and as directed b y Engineer-in-charge. The pipe shall have zinc coating inside & outside confirming to IS: 4736-1986 or latest with upto date amendments & shall be engraved with L290 or X42. The laying shall confirm to BIS: 5822-1970 or latest with upto date amendments DP test shall be performed to the entire satisfaction of the Engineer-in-charge (cost of MS flanges/Nut and bolts. gasket to be measured & paid for separately under item No. 138) including all leads and lifts and as per entire satisfaction of the Engineer-in-charge.
125 mm dia, API 5L (Std)x42 , T-7.90 mm (RD 0.0 to 200) 1st stage
125mm dia, API 5L (Std)x42 , T-6.60 mm (RD 200 to 500) 1st stage
125mm dia, API 5L (Std)x42 , T-5.60 mm (RD 500 to 1000) 1st stage
80mm dia, API 5L (Std)x42 , T-4.00 mm (RD 0 to 200) 2nd stage
Providing and fixing M.S. flanges of various dia (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to API/ MSERW after every 100 mtr. pipe or as per site requirement including cutting of of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect including all leads and lifts and as per entire satisfaction of Engineer - in - charge
125 mm dia, API 5L (Std)x42 , T-7.90 mm, FT-38 (RD 0.0 to 200) 1st stage
125mm dia, API 5L (Std)x42 , T-6.60 mm, FT-38 (RD 200 to 500) 1st stage
125mm dia, API 5L (Std)x42 , T-5.60 mm, FT- 34 (RD 500 to 1000) 1st stage
80mm dia, API 5L (Std)x42 , T-4.00 mm, FT-34 (RD 0 to 200) 2nd stage
Laying, jointing and testing in trenches to be leveled to grades, IS marked GI pipes of following diameters confirming to IS: 1239-1990 ( Part-II) (latest with upto date amendments ) having minimum wall thickness as per class of pipe specified below jointed with butt welding to done on both ends according to relevant BIS standards and detailed specifications including al kinds of short pieces, bends, tees and other special etc. made from parent tubes and jointing with butt welding in three layers as applicable for the particular reach and of technical specification as per site conditions including flushing, cleaning and hydraulic testing as per the direction of the Engineer-in-charge.
125mm dia, (H) (RD 1000 to 1500) 1st stage
125mm dia, (M) (RD 1500 to 1950) 1st stage
80mm dia, (H) (RD 200 to 500) 2nd stage
80mm dia, (M) (RD 500 to 1600) 2nd stage
Providing and fixing M.S. flanges of various dia (nominal bore) of following flange Tables confirming to IS: 6392-1971 or latest with upto date ammendments to G.I. pipe after every 100 mtr. Pipe or as per site requirement including cutting of pipes wherever required, welding in three layers (leak proof) confirming to specifications as perescribed in relevant IS code i.e. IS: 816-1969 or latest as applicable with upto date ammendments with nuts, bolts, washers & specials etc. confirming to IS: 1963 or latest with upto date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorrosive paints complete in all respect including all leads and lifts and as per entire satisfaction of the Engineer-in-charge
125mm dia, (H) Ft-28 (RD 1000 to 1500) 1st stage
125mm dia, (H) Ft-28 (RD 1500 to 1950) 1st stage
80mm dia, (H), FT-28, (RD 200 to 500) 2nd stage
80mm dia, (M), FT-28 (RD 500 to 1000) 2nd stage
80mm dia, (M), FT-17 (RD 1000 to 1600) 2nd stage
1st Stage :-Supply, errection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of standarad make such as KSB/ Mather & Platt/ Jyoti /Kirloskar/ Beaconweir /BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below, including all leads and lifts and as per entire satisfaction of Engineer - in - charge 4 Sets (2 Working and 2 Standby) 4 Set x 100= 400 HP
Ammeter for AC supply of appropriate capacity suitable for the above specified motor in Annexure, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Frequency Meter for AC supply of appropriate capacity suitable for the above specified motor , including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Voltmeter AC supply of appropriate capacfity suitable for the above specified motor , including all leads and lifts and as per entire satisfaction of Engineer - in - charge
MCCB of appropriate capacity suitable for the above specified motor for mains ON/Off to the panel, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Indicator for mains ON-OFF, System Standby- Overload - Run, Sump Empty - Full, RYB Phase, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Motor Protection Circuit Breaker for 3 phase/3 wire under voltage/over voltage protection, short circuit protection, overload protection, phase loss, phase reversal protection and motor disconnect function, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Rust free powder coated Control panel suitable for housing all the above listed electrical and electronics components, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of Kirloskar/Leader/KSB/fouress make of cast steel double flanged Automated / Self Actuated sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure. & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header). (NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class ASA 300 (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of Kirloskar/Leader/KSB/pelicon/Fouress make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 31(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA 300 (seat pressure 52 Kg/cm^2) as per BS-1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of Kirloskar/Leader/KSB/Pelocon/Fouress make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure for Rising main. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA 300 (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of Kirloskar/Leader/KSB/Pelocon/Fouress make cast iron flanged Sluice valve for suction pipe having size one larger than suction size of pump such that velocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments. NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost, including all leads and lifts and as per entire satisfaction of Engineer - in - charge ( For 4 No pump sets).
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost, including all leads and lifts and as per entire satisfaction of Engineer - in - charge ( For 4 No pump sets).
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer), including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/ PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 31 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump, including all leads and lifts and as per entire satisfaction of Engineer - in - charge NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection/commissioning and testing of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions, including all leads and lifts and as per entire satisfaction of Engineer - in - charge.
2nd Stage :-Supply, errection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of standarad make such as KSB/ Mather & Platt/ Jyoti /Kirloskar/ Beaconweir /BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below, including all leads and lifts and as per entire satisfaction of Engineer - in - charge 2 Sets (1 Working and 1 Standby) 2 Set x 60= 120 HP
Ammeter for AC supply of appropriate capacity suitable for the above specified motor in Annexure, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Frequency Meter for AC supply of appropriate capacity suitable for the above specified motor , including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Voltmeter AC supply of appropriate capacfity suitable for the above specified motor , including all leads and lifts and as per entire satisfaction of Engineer - in - charge
MCCB of appropriate capacity suitable for the above specified motor for mains ON/Off to the panel, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Indicator for mains ON-OFF, System Standby- Overload - Run, Sump Empty - Full, RYB Phase, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Motor Protection Circuit Breaker for 3 phase/3 wire under voltage/over voltage protection, short circuit protection, overload protection, phase loss, phase reversal protection and motor disconnect function, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Rust free powder coated Control panel suitable for housing all the above listed electrical and electronics components, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of Kirloskar/Leader/KSB/fouress make of cast steel double flanged Automated / Self Actuated sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure. & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header). (NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class ASA 300 (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of Kirloskar/Leader/KSB/Fouress make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 31(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA 300 (seat pressure 52 Kg/cm^2) as per BS-1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of Kirloskar/Leader/KSB/Fouress make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure for Rising main. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class ASA 300 (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600) compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of Kirloskar/Leader/KSB/Fouress make cast iron flanged Sluice valve for suction pipe having size one larger than suction size of pump such that velocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments. NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).compatible with the automation system, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost, including all leads and lifts and as per entire satisfaction of Engineer - in - charge ( For 2 No pump sets).
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost, including all leads and lifts and as per entire satisfaction of Engineer - in - charge ( For 2 No pump sets).
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer), including all leads and lifts and as per entire satisfaction of Engineer - in - charge
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/ PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments, including all leads and lifts and as per entire satisfaction of Engineer - in - charge
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 31 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump, including all leads and lifts and as per entire satisfaction of Engineer - in - charge NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.
Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection/commissioning and testing of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions, including all leads and lifts and as per entire satisfaction of Engineer - in - charge.
SB Trading company
Oasis Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .