Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹35.8 L+₹1.3 L (3.69%)Rejected-AOC ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹36.0 L+₹1.5 L (4.22%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹36.5 L+₹2.0 L (5.78%)Rejected-AOC 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | L4 | Rejected-AOC Rejected | |
| 5 | L5₹36.9 L+₹2.4 L (7.05%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
5 Jun 2020, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
81345 OUTSOURCING OF SERVICES FOR 22 OR 11 KVA SUB STATION, ELECTRIC SUPPLY AND WATER SUPPLY INSTALLATIONS AND CENTRAL AC PLANTS AT PARUNDU UNDER GE TIRUNELVELI
2020_MES_338280_3
81345
Open Tender
Manpower Supply
Item Rate
330 days
TIRUNELVELI
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE TIRUNELVELI
₹85,000
Yes
17 Jun 2020
21 May 2020
6 Jun 2020
21 May 2020
5 Jun 2020
22 May 2020
Amount
Outsourcing of Services for E/M installations by Electrician at 11/0.433 KV substation at UAV power house, New Adm Block at INS Parundu station for smooth and trouble free operation including running DG sets , ensuring uninterrupted electric supply to the users , cleaning of entire substation area and attending breakdown in substation and entire INS Parundu area and DFO 7N Det Area maintanance works as directed by JE/Engineer-in-charge, controlling of street lights and operating and maintanance of DG sets all as specified and as directed by Engr-in charge. Note: 03 (Three) Shifts Per day I shift ( 0600 Hrs to 14 00 Hrs ) II shift (1400 Hrs to 22 00 Hrs) III shift (2200 Hrs to 0600 Hrs)
Electrician Mate (Semi Skilled) - 03 Nos
Outsourcing of Services for E/M installations by Electrician HT 11 KV Sub Station at ATC Power house at INS Parundu, station for smooth and trouble free operation including rectification of defects , ensure uninterrupted electric supply to the users , cleaning of entire substation area and attending breakdown in substation and entire INS Parundu area and DFO 7N Det Area maintanance works directed by JE/Engineer-in-charge, controlling of street lights and operating and maintanance of DG sets , all as specified and as directed by Engr-in charge. Note: 01 (One) Shift Per day shift timings as decided by the Engineer-in-Charge I shift ( 0600 Hrs to 14 00 Hrs ) II shift (1400 Hrs to 22 00 Hrs) III shift (2200 Hrs to 0600 Hrs) General Shift ( 0900 Hrs to 1700 Hrs)
Electrician Mate(Semi Skilled) - 01 Nos
Outsourcing of Services for E/M installations by Electrician HT 22 KV 2 Pole structure, 4 pole structure ,22/11 KV Transformers , 11 KV Sub Station at main receiving station (MRS) at INS Parundu and HT 11 KV Sub Station at TS Power house, 4 pole structure , 11/0.433 KV substation at TS power house, station for smooth and trouble free operation including rectification of defects , ensure uninterrupted electric supply to the users , cleaning of entire substation area and attending breakdown in substation and entire INS Parundu area and DFO 7N Det Area maintanance works directed by JE/Engineer-in-charge, controlling of street lights and operating and maintanance of DG sets all as specified and as directed by Engr-in charge. Note: 03 (Three) Shifts Per day I shift ( 0600 Hrs to 14 00 Hrs ) II shift (1400 Hrs to 22 00 Hrs) III shift (2200 Hrs to 0600 Hrs)
Electrician Mate (Semi Skilled) - 03 Nos
Outsourcing of Services for DFO Power house , DG Sets and water supply installation at 7N DET fresh water pump house, ward room pump house, booster pump 35 single Officer accomodation at INS Parundu and 7N DET round the clock including Sunday & holiday and including operation of connected items such as valves, pumpsets, starters, chlorination and checking chlorine level, cleaning the entire pump house, maintanance works directed by JE/Engineer-in-charge, controlling of street lights and operating and maintanance of DG sets ,smooth and trouble free operation including rectification of defects , ensure uninterrupted electric supply to the users , all as specified and as directed by Engr-in charge maintaining log sheets area all as specified and directed by Engr-in-charge. Note: 03 (Three) Shifts Per day I shift ( 0600 Hrs to 14 00 Hrs ) II shift (1400 Hrs to 22 00 Hrs) III shift (2200 Hrs to 0600 Hrs)
Electrician Mate (Semi Skilled) - 03 Nos
Outsourcing of Services at INS Parundu round the clock including Sunday & holiday and maintenance & operation of centralized AC plant of water cooled chillers 3 x 26 TR suitable for operation on 440 volts 3 phase system fully autommaticwith 50% standby required air conditioning for certain locations for 24 hrs operation to maintain design condition of 22 degree centigrade plus or minus 3 degree centigrade and 55 % RH plus or minus 5% including compressor chiller , condensor, condensor pumps chilled water pumps, electrical motors , refrigeration piping, water piping, cooling tower, Air handling unit (AHU) with chilled water coil, GI ducing for supply air/ return air, Humidification and heating system , fire dampers , safety and control devices, power cabling and supporting other accessories etc... all as directed by Engr-in-charge. Note: 03 (Three) Shift Per day shift timings as decided by the Engineer-in-Charge I shift ( 0600 Hrs to 14 00 Hrs ) II shift (1400 Hrs to 22 00 Hrs) III shift (2200 Hrs to 0600 Hrs) General Shift ( 0900 Hrs to 1700 Hrs)
Refigeration Mechanic (Skilled) - 01 Nos
Refigeration Mechanic Mate (Semi Skilled) - 02 Nos
Outsourcing of Services for water supply installation at INS Parundu including Pumping/operation at TS fresh water pump house, Cauvery pump house at INS Parundu round the clock including Sunday & holiday and including operation of connected items such as valves, pumpsets, starters, chlorination and checking chlorine level, cleaning the entire pump house, maintanance works and attending breakdown in substation and entire INS Parundu area, DFO and 7 'N' Det area,maintanance works directed by JE/Engineer-in-charge, controlling of street lights and operating and maintanance of DG sets, all as specified and as directed by Engr-in charge. Note: 03 (Three) Shifts Per day I shift ( 0600 Hrs to 14 00 Hrs ) II shift (1400 Hrs to 22 00 Hrs) III shift (2200 Hrs to 0600 Hrs)
FGM Mate (Semi Skilled) - 03 Nos
Providing routine maintenance of Electrical wiring (repair/replacement to wiring, switch boards, socket outlets, regulators/ MCCBs/ MCBs/ Distributionb boards etc. complete) and fixtures such as LED/Tube light/CFL fittings/Ceiling fans/Exhaust fans/ geysers/ etc... complete in MES buildings at INS Parundu and 7 N Det and DFO area and attending breakdown in substation and entire INS Parundu area and DFO 7N Det Area maintenance works at Ramnad, all works directed by JE E/M/Engineer-in-Charge by providing one Electrician and one helper each for one general shift all as specified and directed :- Notes:- (a) 01 (One) Shift Per day(one shift each of Electrician & Electrician mate) General Shift ( 0900 Hrs to 1700 Hrs) (b) Certain Maintenance items shall be issued by the Dept. on free of cost and certain other items are to be procured by the contractor under Supply only items mentioned here-in-after and the rates for fixing of all these electrical fittings/fixtures are deemed to be included in the rates quoted under Sl item Nos. 1 to 7 here-in-before. (c) All T & P required for the Electrician shall be issued by the Contractor. .
Electrician ( Skilled) - 01 Nos
Electrician Mate(Semi Skilled) - 01 Nos
Note for Sl Item Nos. 1 to 7 here-in-before : (a) The rates quoted is inclusive for attending all complaints of Internal / External electrification, water supply installations, AC plants and water supply break downs including liasoning with TNEB and Water Supply department to restore supply in case of break down / failure of supply. (b) Any other minor work and minor item to restore the electric supply as directed by the Engineer - in- charge. (c) The rate quoted is deemed to include the cost towards uniform for the staff employed for wearing during the working hours . the uniform shall be pant, shirt & shoes and the pattern of the uniform shall be decided by the Engr- in -Charge. (d) The rate quoted is deemed to be inclusive of supply and maintenance of the documents such as log sheets of DG Set, Pump set, complaint register, Earth test register, Attendence register, Duty register, AC plant log sheet etc... all as directed of the plant and plant maintenance record book and daily log sheet .
(e) The rate quoted is deemed to be inclusive of cost towards keeping the substation, AC Plant, DG Set,Feeder pillar box,DBs and pumphouse surrounding area neat and tidy during the entire period of contract. (f) The rate quoted is deemed to be inclusive of tools and safety equipment required for running and maintenance of plants. (g) Checking of presence of chlorine on daily bases and PH testing as directed by Engr -in-Charge (h) Maintain the record of the same is to be carried out cost is inclusive of items required for testing of water. (j) Testing of water samples once in every five months as directed by Engr -in- Charge for chemical and bacteriological analysis from Govt Authorised Laboratory.
(k) Necessary DHPP (Diesel) for the running of DG Set and Engine oil for toping of will be issued as and when required basis free for running the installations, contractor has to collect the Diesel/Engine oil from the MES. (l) Necessary inventory for the items installed at site to be prepared jointly for Handing Taking over of assets between Department and Contractor, any Deficiencies in items noticed during the period of contract,the contractor shall be liable to make good to the items with the the items of original specifications as received at the time of taking over. (m) In case the contractor defaults in deploying sufficient manpower as stipulated in the CA conditions, Rs. 1000 per shift per operator shall be deducted from running account receipts payment as penalty in addition to recovery of rates quoted under respective items of Sch ‘A’ BoQ (n) It will be Contractors responsibility to submit all the documents as asked by the Security Department of the concerned area to obtain Necessary Entry Passs to the working area and copy of the same should be submitted to the Engineer In-charge.
(o) All the Plants to be kept in serviceable condition with Minor Repairs and replacements not included in BOQ (Not costing more than Rs 5000 during the contract Period) Any Major Faults occurred to be intimated to concerned JE and Engr in Charge so that the same can be rectified immediately. (p) Spares required for urgent repair of E/M equipments will be issued as and when requried basis at MES store yard subject to availability of the stores. Cost for fixing of the items is deemed to be included in Sl item Nos. 1 to 7 in BOQ here-in-before . (q) The power Factor to be monitored regularly and to maintain proper record.Incase of any fault in the APFC Panel the same to be intimated to JE/Engineer in charge Immediately.
(r) Electrician has to operate the DG Set in case of Electric failure in addition to the duty of Electrician. (s) Electrician has to maintain the VCBs and close watch on HT fuses and GOD's. (t) One shift of 08 hours are considered, General maintenance of E/M Installations as and when needed shall be carried out round the clocks all as directed by Engg-in-charge (u) Daily maintenance of installation all as per manufactures instruction including greasing , lubricating etc... shall be included in the unit rate quoted by the contractor. (v) Log sheet of all DG Set including daily running hours and maintenance carried out , consumption of grease,lubricants,DHPP (Diesel) etc shall be maintained by the contractor in their installation and same will be checked by th Eng-in-charge periodically and daily by JE.
(w)The rate quoted shall be deemed to be included for topping up of battery electrolyte/distilled water,cleaning/replacement of battery terminals ,charging of batteries and replacement of fan belt,fuel pipe,fuel cap if required etc... all as directed by Eng-in-charge. (x) Cleaning of entire Sub station & equipments daily and the contractor shall be issued cleaning items such as cotton waste, brooms etc... to the operator. (y) Daily maintenance of water supply installations all as per manufactures instruction including greasing , lubricating etc... shall be included in the unit rate quoted .The unit rates against the item shall be deemed to include the cost of minor repair to the foot valve system by replacing the leather flap, rubber insertion , nuts &bolts etc... (z)The AC plant shall be operated in three shifts of 08 hours .However the timings of duty may be changed as per the requirement at site and as directed by Engineer in charge and nothing extra will be paid on this account.
(aa) Daily maintenance of Central AC Plant installation all as per manufactures instruction including greasing , lubricating etc shall be included in the unit rate quoted by the contractor.The unit rates against the item shall be deemed to include the cost of minor repair of AC plant. (ab) DG Set/ Pumpset /AC Plant/ Electric supply installation shall be operated by any of the operater as required/directed by Eng-in-charge. (ac) Cleaning of entire AC plant & equipments daily and the contractor shall be issued cleaning items such as cotton waste, brooms etc to the operator.
Cutting and cleaning the bushes and unwanted plant growth inside E/M installations at main receiving station inside fencing and around Main Substation, all unwanted materials shall be removed around the installation and substation premise in every 3 months and depositing waste material outside INS Parundu Complex all as directed by Engineer-in-Charge.
Cutting and cleaning the bushes and unwanted plant growth inside E/M installations at UAV Power house inside complex and up to 10 mtr from wall of buildings of Power house and near by E/M installations, all unwanted materilas shall be removed around the installation and substation premise complex in every 3 months and depositing waste material outside INS Parundu Complex all as directed by Engineer-in-Charge.
Cutting and cleaning the bushes and unwanted plant growth inside E/M installations at TS Power house and around Main Substation, around the installation, Four pole structure and substation premise, all unwanted materials shall be removed around the installation and substation premise in every 3 months and depositing waste material outside INS Parundu Complex all as directed by Engineer-in-Charge.
Cutting and cleaning the bushes and unwanted plant growth inside E/M installations at ATC Power house and around Main Substation, all unwanted materilas shall be removed around the installation, and nearby E/M equipments and substation premise in every 3 months and depositing waste material outside INS Parundu Complex all as directed by Engineer-in-Charge.
Cutting and cleaning the bushes and unwanted plant growth inside E/M installations at DFO Pump house inside cxomplex and up to 5 mtr from wall of buildings of Pump house and near by old Office complex, all unwanted materilas shall be removed around the installation and substation premise in every 3 months and depositing waste material outside INS Parundu Complex all as directed by Engineer-in-Charge.
Cutting and cleaning the bushes and unwanted plant growth inside E/M installations at TS Pump house inside complex and up to 10 mtr from wall of buildings of Pump house and near by MES buildings, Over head tanks (100000 Ltr capacity and 15000 Ltr capacitry), all unwanted materilas shall be removed around the installation and substation premises, MES buildings etc... in each 3 months and depositing waste material outside INS Parundu Complex all as directed by Engineer-in-Charge.
Supply only of the following items complete all as specified and directed. Note: The cost of fixing of the undermentioned supply only items are deemed to be included in the rates quoted for Sl item Nos. 1 to 7 here-in-before.
Cotton waste for cleaning of DG sets, Transformers, panel boards etc...
Fan belt suitable for AHUs / DG sets
PVC flexible tube (hose pipe) of standard quality suitable for DG set
MCB TP 40 Amps 10 KA breaking capacity Make: L&T/Legrand/ABB/Siemens/Schneider/Standard/Indo-asian as approved by GE
MCB TPN 40 Amps 10 KA breaking capacity Make: L&T/Legrand/ABB/Siemens/Schneider/Standard/Indo-asian as approved by GE
MCB TPN 50 A/63 Amps 10 KA breaking capacity Make: L&T/Legrand/ABB/Siemens/Schneider/Standard/Indo-asian as approved by GE
Lugs of size 10 to 25 sqmm
Lugs of size 35 to 50 sqmm
Lugs of size 70 to 95 sqmm
Lugs of size 120 to 185 sqmm
Lugs of size 240 to 300 sqmm
Petroleum jelly
Fuse wire
Step Regulator for fan, 1 Module Make: Legrand/Crompton/Bajaj/Orient as approved by GE
JR ENTERPRISES
Powertech Equipments And Services
S KUMARAN
M.G.Swamy and Co.,
SHANMUGA TRADERS
Vinayaga constructions
P JAGANNADHA RAJU
sri manikandan enterprises
SUSII CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .