GE RAMGARH CANTT
GE RAMGARH CANTT, JHARKHAND, PIN 829122
REPAIR AND MAINT OF DG SET E/M INSTALLATION AND CHLORINATION SYSTEM UNDER GE RAMGARH
2022_MES_502621_1
8300/3094/E8
Open Tender
Civil Works
Item Rate
270 days
GE RAMGARH
Class E Cat b(i)
7 documents required · 7 mandatory
₹500
Yes
GE RAMGARH CANTT
₹29,980
Yes
1 Apr 2022
21 Jan 2022
24 Feb 2022
21 Jan 2022
22 Feb 2022
9 Feb 2022
Amount
Comprehensive maintenance of DG set of capacity 12.5 KVA with cleaning, oiling, greasing, minor repairs of any kind to diesel engine and AC generator including replacement of spare parts like clamps, tappet cover gasket, water pump gasket, radiator gaskets, minor repair of self starter, alternator/dynamo, adjustment of carbon brush of any type, adjustment of AVR & Tappets, replacement of battery brass terminal, repair to battery post, replacement of toggle switches, repairing to wiring in control panel of Gen set using existing size of copper wire, cleaning of diesel storage tank, replacement of level indicator, outlet valves, Piston ring set, small end bush for connecting rod, Large end bearing and bolt for connecting rod, Fuel filter single bowl with 'O ring complete', Fuel pipe feed pump to filter, Fuel pipe filter to FI pump, Lub oil filter element with sealing ring, Fan belt, replacement of required quantity of coolant and distilled water in radiator assy & battery respectively as required complete along with calibration of FIP if necessary, repair of radiator assembly, repair of self starter, alternator, DC control panel AMF Panel, painting to DG set once in a year etc. all as specified and as directed. Notes: (i) Spares required for replacement will be measured and paid separately under separate items (ii) Each maintenance job shall be covered period of 12 months.
All as per item No.1 here-in-before but 40-63 KVA capacity of DG set.
All as per item No.1 here-in-before but 100 to 125 KVA capacity of DG set.
All as per item No.1 here-in-before but 250 KVA capacity of DG set.
All as per item No.1 here-in-before but 320 KVA capacity of DG set.
Supply only Fuel feed pump for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Bearing set of 5 for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Piston with piston pin, circlip for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Connecting rod, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Cylinder liner with joint ring, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Complete gasket set, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Head gasket, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Inlet and exhaust valve, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only High pressure pipe complete set, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Fuel filter element pre & Micro, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Lub oil cooler for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Set of hose pipe for water inlet & outlet connection with clamp, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Thermostat element, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Anti vibration mounting of radiator, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Alternator 12V assy, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Starter 12 V, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Silencer muffler of suitable size, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only diaphragm coupling, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only stop solenoid 12 V, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only solenoid valve 12 V, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Banded wrapped belt 21A 52, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Exhaust air buffle, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Non return valve, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
Supply only Nozzle, for top overhauling/maintenance of DG set 12.5 KVA to 320 KVA, complete all as directed.
M & Labour for rewinding of MX unit with suitable size of super enamelled copper wire including heating varnishing providing required insulating materials for alternator cap 12.5 to 320 KVA.
Supply & fixing only carbon brush holder of alternator 12.5 KVA to 320 KVA, complete all as directed.
Supply only rectifier of alternator 12.5 KVA to 320 KVA, complete all as directed.
Supply only of AVR suitable for 12.5-63 KVA DG set, complete all as directed.
Supply only of AVR suitable for 100-320 KVA DG set, complete all as directed.
Filling only of Engine oil 20W40 210 Ltr to top up/refilling of all DG set as per the direction of Engr-in-Charge. Make: Gulf/Castrol/Volvalin.
Supply only of battery 180 Ah, 25 plate with initial Charger Specific gravity 12.60 of 12 Volts, Complete all as specified and as directed by Engr-in-Charge. Make: Exide/Amron/ or its equivalent as approved.
Supply only of battery 200 Ah, 25 plate with initial Charger Specific gravity 12.60 of 12 Volts, Complete all as specified and as directed by Engr-in-Charge. Make: Exide/Amron/ or its equivalent as approved.
Dismantling of 7.5 HP capacity air compressor and carrying out repairs by replacing worn out/damaged parts, overhauling and providing major parts such as piston ring set, guide valve, valve guide screw, bush lining, pin gudgeon, bearing ball, oil seal, seeger ring, ring locking, suction filter, pressure switch, pressure gauge, delivery pipe, gasket set etc., complete with all accessories as per site requirement including assembling, testing commissioning all as directed.
Disconnecting the defective/burnt alternator from the engine and removing it from the base frame and shifting it to the workshop, removing rust and cutting the field copper winding or armature winding and cleaning the slots complete for rewinding and using super enamelled copper wire, varnishing and drying three coats of insulating varnishing and reassembling the motor after repairs/re-setting complete re-installation at site including transportation complete of capacity 100 KVA DG set.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm, 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm, 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sq mm, 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sq mm, 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm, 3.5 core, complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sq mm, 3.5 core, complete all as specified and as directed.
Supply and laying GI pipe 80mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one, complete all as specified and as directed.
Supply and laying GI pipe 100mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one, complete all as specified and as directed.
Supply and laying GI pipe 150mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one, complete all as specified and as directed.
Repair and maintenance of Chemical Dozing pumps of any Make and capacity including replacement of defective/unserviceable suction/discharge pipe 3/8", duck bill and connecting nut 3/8" etc after taking out the old ones with new ones complete al as specified and as directed. Note: Cost of Minor repairs/replacement of minor spares such as nuts, bolts, washers etc., are deemed to be included in the unit quoted rates. 2) The cost of transportation to nearest workshop and back after repair if necessary is deemed to be included in the unit quoted rate.
Supply and fixing pump tube, of Chemical Dozing Pumps, complete all as directed.
Supply and fixing Injection Check valve, of Chemical Dozing Pumps, complete all as directed.
Supply and fixing foot valve 3/8", of Chemical Dozing Pumps, complete all as directed.
Supply and fixing connecting with adapter 3/8", of Chemical Dozing Pumps, complete all as directed.
ranjit singh
M/S Akash Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .