Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LQualified | L1 | Qualified MSE, Category: General | |
| 2 | L2₹5.1 L+₹8,815 (1.76%)Qualified 737 7TH FLOOR FORTUNE TOWER SAYAJIGUNJ NR PARSI AGYARI GROUND VADODARA GUJARAT 390020 UDYAM GJ 24 0003491 | VADODARA | GUJARAT | 390020 | L2 | Qualified MSE, Category: General | |
| 3 | L3₹5.5 L+₹48,037 (9.61%)Qualified 711 712 YASHKAMAL BUILDING NR KALAGHODA CIRCLE SAYAJIGUNJ VADODARA GUJARAT 390020 UDYAM GJ 24 0003492 | VADODARA | GUJARAT | 390020 | L3 | Qualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 Mar 2024, 12:00 pmClosed
Provn of Air Conditioner
6118602
GEM/2024/B/4686825
Two Packet Bid
Supply and install split Air conditioning unit White inverter type,Supply and install split Air con
10 days
Gujarat; Vadodara
Total value wise evaluation
BOQ
2 documents required · 2 mandatory
Exempted
8 Mar 2024
24 Feb 2024
5 Mar 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Supply and install split Air conditioning unit White inverter type | Supply and install split Air conditioning unit White inverter type with split units indoor oblique outdoor with insulated copper tubing comma Copper condenser coil comma precision cooling technology comma dual rotor inverter technology R32 oblique R410 or any other ecofreindly refrigerant Brushless DC motor 4 in1 Convertible Cooling auto clean Magic Display ecofriendly refrigerent copper wound rotary compressor complete with cordless remote control unit Stand for outdoor unit and dust filter for batter indoor air quality 5 star rating SEER 4 point 51 and of capacity 1 point 5 TR as comprising of the following
first 1 point 5 Ton capacity using Eco friendly refrigernt cooling unit wall mounting type complete with remote control draining out arrangement manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr in charge Make Hitachi oblique blue star oblique LG oblique Voltas Second One No condensing unit of 1 point 5 ton capacity comprising of all fitting such as single phase electric driven compressor condensing fan motor condensor with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engr in charge
Note Aditional length for copper tubing if required at site shall be supply and fix by the contractor without any extra cost
second rate for filling of hole with white cement oblique POP included in item rate | 5 | Each | AGETBARODA | 10 |
| 2 | Supply and install split Air conditioning unit White inverter type | Supply and install split Air conditioning unit White inverter type with split units indoor oblique outdoor with insulated copper tubing Copper condenser coil precision cooling technology dual rotor inverter technology R32 oblique R410 or any other ecofreindly refrigerant Brushless DC motor 6 in1 Convertible Cooling auto clean Magic Display ecofriendly refrigerent copper wound rotary compressor complete with cordless remote control unit Stand for outdoor unit and dust filter for batter indoor air quality 5 star rating SEER 4 point 51 and of capacity 2TR as comprising of the following
First 2 Ton capacity using Eco friendly refrigernt cooling unit wall mounting type complete with remote control draining out arrangement manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr in charge Make Hitachi blue star LG Voltas Second One No condensing unit of 2 ton capacity comprising of all fitting such as single phase electric driven compressor condensing fan motor condensor with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engr in charge
Note First Aditional length for copper tubing if required at site shall be supply and fix by the contractor without any extra cost
Second rate for filling of hole with white cement POP included in item rate | 2 | Each | AGETBARODA | 10 |
| 3 | Supply and fix Voltage stabilizer for automatic operation | Supply and fix Voltage stabilizer for automatic operation comma single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of plus minus 2 point 5 percent and of capacity 3 KVA | 5 | Each | AGETBARODA | 10 |
| 4 | Supply and fix Voltage stabilizer for automatic operationcomma single phase | Supply and fix Voltage stabilizer for automatic operationcomma single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of plus minus 2 point 5 percent age and of capacity 5 KVA | 2 | Each | AGETBARODA | 10 |
| 5 | Material and Labour for submain wiring 2 runs of 4 sqmm | Material and Labour for submain wiring 2 runs of 4 sqmm for phase and neutral and one run of 4 sqmm for earth continuity FRLS grade PVC insulated copper wire laid through 25 mm dia PVC conduit complete with conduit accessories
Make of wires Havells oblique Plaza
Make of conduit Polycab oblique Sudakar oblique precission | 25 | RM | AGETBARODA | 10 |
| 6 | Supply and fix 20 Amp Industrial metal | Supply and fix 20 Amp Industrial metal clad plug in socket and plug top with 20 amp SP MCB make Indoasian oblique Havells oblique BB oblique L and T oblique Schnider | 7 | Each | AGETBARODA | 10 |
| 7 | Excavation in trenches not exceeding 1 point 5m | Excavation in trenches not exceeding 1 point 5m wide and not exceeding 1 point 5m in depth and getting out in any type of soil | 7 | CUM | AGETBARODA | 10 |
| 8 | Removal of excavated material to a distance not exceeding 50m | Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level n exc 1 point 5m above the starting point complete all as specified anddirected by Engineer in Charge | 4 | CUM | AGETBARODA | 10 |
| 9 | Returning filling excavated soil in trenches including spreading levelling | Returning filling excavated soil in trenches including spreading levelling watering and well ramming in layers not exceeding 25 cm thick each all as directed by Engineer InCharge | 3 | CUM | AGETBARODA | 10 |
| 10 | Sand cushioning to underground cables with sand | Sand cushioning to underground cables with sand complete all as specified in clause 19 point 75 of SSR Part1 | 3 | CUM | AGETBARODA | 10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_6118602.pdf
GEM_BID
new_microsoft_word_document_2024-02-24-11-22-46_5a74f4ab4f4adb29acca3683f8fa6cc2.pdf
BOQ
boq_2024-02-16-17-30-35_c077553faa875bd05bea780788c_2024-02-24-11-22-46_c9cd68b7eada4e687fc24981c4bf9660.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .