Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.5 CrAccepted-AOC 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹3.5 Cr | 1 | Accepted-AOC Lowest |
| 2 | 2₹4.4 Cr+₹89.6 L (25.7%)Rejected-AOC 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹4.4 Cr+₹89.6 L (25.7%) | 2 | Rejected-AOC Second lowest |
| 3 | 3₹4.4 Cr+₹93.4 L (26.8%)Rejected-AOC | ₹4.4 Cr+₹93.4 L (26.8%) | 3 | Rejected-AOC Third lowest |
| Sl No | Description | Qty | Unit | sterling and wilson ltd L2 | VOLTAS LIMITED L1 | JUDE ENGINEERING L3 |
|---|---|---|---|---|---|---|
| 1.00PART I-HVAC OPERATION & ROUTINE MAINTENANCE CONTRACT Operation & Routine Maintenance Contract for 3 years Full time round the clock & year round, operation & routine maintenance of HVAC system which includes Chillers, pumps, CT's, AHU, FAHU with Heat Recovery Wheels, Ventilation fans, ducting, piping, insulation, controls, wiring etc, VRF System (including Indoor Units, Outdoor Units, Refrigerant Piping, Air distribution networks, insulation, controls, wiring etc) & all other items including associated electrical systems as per the inventory list (Annexure A&B)and operation of building management system for HVAC system, maintaining log books, break down register & functional requirements etc. and as per recommendations of OEM for a period of 3 years as per the SCC. | ||||||
| 1.01 | 1st year | 12 | Months | 4,57,090 ₹54,85,080 | 3,89,318 ₹46,71,816 Lowest | 4,00,000 ₹48,00,000 |
| 1.02 | 2nd year | 12 | Months | 4,79,945 ₹57,59,340 | 4,04,891 ₹48,58,692 Lowest | 4,40,000 ₹52,80,000 |
| 1.03 | 3rd year | 12 | Months | 5,03,941 ₹60,47,292 | 4,21,087 ₹50,53,044 Lowest | 4,84,000 ₹58,08,000 |
| 2.00PART II-All Inclusive Comprehensive Maintenance Contract of Low side for 3 years All Inclusive Comprehensive Maintenance Contract for all equipment covered under inventory list(Annexure-B), Preventive Maintenance as per the recommendations of OEM and as per the technical specification and scope along with attending infinite number of breakdown maintenance for the equipment covered under this contract scope,as per the SCC. | ||||||
| 2.01 | 1st year | 12 | Months | 2,48,723 ₹29,84,676 | 1,60,335 ₹19,24,020 Lowest | 2,00,000 ₹24,00,000 |
| 2.02 | 2nd year | 12 | Months | 2,52,659 ₹30,31,908 | 1,65,145 ₹19,81,740 Lowest | 2,25,000 ₹27,00,000 |
| 2.03 | 3rd year | 12 | Months | 2,66,192 ₹31,94,304 | 1,70,099 ₹20,41,188 Lowest | 2,50,000 ₹30,00,000 |
| 3.00PART III-Annual Maintenance Contract of Split and Ductable AC units for all equipment covered under inventory list (Annexure-C) for 3 years,as per the SCC. | ||||||
| 3.01 | AMC of 4 Nos 0.8 TR Split Air conditioner units-1st Year | 12 | Months | 320 ₹3,840 | 293 ₹3,516 Lowest | 800 ₹9,600 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
18 Sept 2025, 11:00 amClosed
Managing Director, Kannur Airport
Kannur International Airport Ltd, Kannur International Airport PO Mattannur,Kannur-670708
Operation and Maintenance and AICMC of HVAC systems at PTB and ATC buildings and AMC of Split AC and Ductable AC units at different buildings of Kannur International Airport Ltd for three years including BMS operation of HVAC systems
2025_KIAL_791633_1
KIAL/ENGG-E/HVAC/01/2025
Open Tender
Repair and Maintenance Works
Item Rate
1080 days
Kannur
Refer NIT document
9 documents required · 9 mandatory
₹8,850
₹1 L
15 Oct 2025
29 Aug 2025
19 Sept 2025
29 Aug 2025
18 Sept 2025
29 Aug 2025
29 Aug 2025 - 11 Sept 2025
Amount
PART I-HVAC OPERATION & ROUTINE MAINTENANCE CONTRACT Operation & Routine Maintenance Contract for 3 years Full time round the clock & year round, operation & routine maintenance of HVAC system which includes Chillers, pumps, CT's, AHU, FAHU with Heat Recovery Wheels, Ventilation fans, ducting, piping, insulation, controls, wiring etc, VRF System (including Indoor Units, Outdoor Units, Refrigerant Piping, Air distribution networks, insulation, controls, wiring etc) & all other items including associated electrical systems as per the inventory list (Annexure A&B)and operation of building management system for HVAC system, maintaining log books, break down register & functional requirements etc. and as per recommendations of OEM for a period of 3 years as per the SCC.
1st year
2nd year
3rd year
PART II-All Inclusive Comprehensive Maintenance Contract of Low side for 3 years All Inclusive Comprehensive Maintenance Contract for all equipment covered under inventory list(Annexure-B), Preventive Maintenance as per the recommendations of OEM and as per the technical specification and scope along with attending infinite number of breakdown maintenance for the equipment covered under this contract scope,as per the SCC.
1st year
2nd year
3rd year
PART III-Annual Maintenance Contract of Split and Ductable AC units for all equipment covered under inventory list (Annexure-C) for 3 years,as per the SCC.
AMC of 4 Nos 0.8 TR Split Air conditioner units-1st Year
AMC of 39 Nos 1 TR Split Air conditioner units-1st Year
AMC of 61 Nos 1.5 TR Split Air conditioner units-1st Year
AMC of 17 Nos 2 TR Split Air conditioner units-1st Year
AMC of 6 Nos 3 TR Ductable Air conditioner units-1st Year
AMC of 1 Nos 4 TR Ductable Air conditioner units-1st Year
AMC of 3 Nos 5.5 TR Ductable Air conditioner units-1st Year
AMC of 4 Nos 8.75 TR Ductable Air conditioner units-1st Year
AMC of 4 Nos 0.8 TR Split Air conditioner units-2nd Year
AMC of 39 Nos 1 TR Split Air conditioner units-2nd Year
AMC of 61 Nos 1.5 TR Split Air conditioner units-2nd Year
AMC of 17 Nos 2 TR Split Air conditioner units-2nd Year
AMC of 6 Nos 3 TR Ductable Air conditioner units-2nd Year
AMC of 1 Nos 4 TR Ductable Air conditioner units-2nd Year
AMC of 3 Nos 5.5 TR Ductable Air conditioner units-2nd Year
AMC of 4 Nos 8.75 TR Ductable Air conditioner units-2nd Year
AMC of 4 Nos 0.8 TR Split Air conditioner units-3rd Year
AMC of 39 Nos 1 TR Split Air conditioner units-3rd Year
AMC of 61 Nos 1.5 TR Split Air conditioner units-3rd Year
AMC of 17 Nos 2 TR Split Air conditioner units-3rd Year
AMC of 6 Nos 3 TR Ductable Air conditioner units-3rd Year
AMC of 1 Nos 4 TR Ductable Air conditioner units-3rd Year
AMC of 3 Nos 5.5 TR Ductable Air conditioner units-3rd Year
AMC of 4 Nos 8.75 TR Ductable Air conditioner units-3rd Year
Spare supply rate for -0.8 Tr / 1 Tr Split AC units for 3 years
Split AC Indoor unit Fan Motor
Split AC Indoor unit Fan Motor Blower
Split AC Condenser Fan Motor
Split AC Condenser Fan Motor Blade
Split AC Control Card
Capacitor - 36 µF (For compressor)
Capacitor – 2.5 µF (For condenser fan motor)
Stabilizer unit for 1 Tr Split AC
Coil Sensor
Temperature Sensor
Spare supply rate for -1.5 Tr Split AC units for 3 years
Split AC Indoor unit Fan Motor
Split AC Indoor unit Fan Motor Blower
Split AC Condenser Fan Motor
Split AC Condenser Fan Motor Blade
Split AC Control Card
Capacitor - 40 µF (For compressor)
Capacitor – 3 µF (For condenser fan motor)
Stabilizer unit for 1.5 Tr Split AC
Coil Sensor
Temperature Sensor
Spare supply rate for -2 Tr Split AC units for 3 years
Split AC Indoor unit Fan Motor
Split AC Indoor unit Fan Motor Blower
Split AC Condenser Fan Motor
Split AC Condenser Fan Motor Blade
Split AC Control Card
Capacitor - 45 µF (For compressor)
Capacitor – 3 µF (For condenser fan motor)
Stabilizer unit for 2 Tr Split AC
Coil Sensor
Temperature Sensor
Spare supply rate for -3 Tr Ductable AC units for 3 years
Duct able Split AC Indoor unit Fan Motor
Duct able Split AC Indoor unit Fan Motor Blade
Duct able Split AC Condenser Fan Motor
Duct able AC Condenser Fan Motor Blade
Duct able Split AC Display Controller
Duct able Split AC Control Card
Capacitor - 50 µF (For compressor)
Capacitor – 3 µF (For condenser fan motor)
Coil Sensor
Temperature Sensor
Spare supply rate for -4Tr Tower AC units for 3 years
Tower Split AC Indoor unit Fan Motor
Tower Split AC Indoor unit Fan Motor Blade
Tower Split AC Condenser Fan Motor
Tower Split AC Condenser Fan Motor Blade
Tower Split AC Control card
Tower Split AC Display Controller
Capacitor - 50 µF (For compressor)
Capacitor – 6 µF (For condenser fan motor)
Coil Sensor
Temperature Sensor
Spare supply rate for -5.5 Tr Ductable AC units for 3 years
Ductable Split AC Indoor unit Fan Motor
Ductable Split AC Indoor unit Fan Motor Blade
Ductable Split AC Condenser Fan Motor
Ductable Split AC Condenser Fan Motor Blade
Ductable Split AC Control card
Ductable Split AC Display Controller
Capacitor - 50 µF (For compressor)
Capacitor – 10 µF (For condenser fan motor)
Coil Sensor
Temperature Sensor
Spare supply rate for -8.5 Tr Ductable AC units for 3 years
Ductable Split AC Indoor unit Fan Motor
Ductable Split AC Indoor unit Fan Motor Blade
Ductable Split AC Condenser Fan Motor
Ductable Split AC Condenser Fan Motor Blade
Ductable Split AC Control card
Ductable Split AC Display Controller
Capacitor - 50 µF (For compressor)
Capacitor – 10 µF (For condenser fan motor)
Coil Sensor
Temperature Sensor
Replacement of defective compressor with replacement unit of the OEM/ Supplier.Supply of following compressor.
Replacement of defective Inverter PCB with replacement unit of the OEM / Supplier.Supply of following Inverter PCB.
PART IV-All Inclusive Comprehensive Maintenance Contract of Chillers for 3 years All Inclusive Comprehensive Maintenance Contract for the chillers covered under inventory list(Annexure-A),All chillers shall be maintained exclusively through the Original Equipment Manufacturer (OEM) )/authorized agency of OEM.All inclusive comprehensive maintenance contract including preventive maintenances and infinite breakdown maintenances of the chillers installed in the HVAC plant at Kannur Airport,as per SCC.
York make Chillers(600 TR Centrifugal-3 Nos, 200TR screw-1 No) -1st Year
York make Chillers(600 TR Centrifugal-3 Nos, 200TR screw-1 No) -2nd Year
York make Chillers(600 TR Centrifugal-3 Nos, 200TR screw-1 No) -3rd Year
Dunham Bhush make Chillers with Harmonic filter panel (600 TR Centrifugal-1 No) -1st Year
Dunham Bhush make Chillers with Harmonic filter panel (600 TR Centrifugal-1 No) -2nd Year
Dunham Bhush make Chillers with Harmonic filter panel (600 TR Centrifugal-1 No) -3rd Year
sterling and wilson ltd (BID ID -2343708)
JUDE ENGINEERING (BID ID -2341187)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .