Loading…
Loading…
Tender Value
₹4.3 Cr
EMD Value
₹8.6 L
Closing Date
25 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT TRD
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N or V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheet duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer should have minimum 33 KV Electrical Contractor License. They shall submit duly up loading the copy self attested/digitally signed by the tenderer or authorized representative of the tendering firm along with the offer.
27 conditions · 6 needing a document upload
The tenderer shall clearly specify whether the tender issubmitted on his own (Proprietary Firm) or on behalf of aPartnership Firm / company / Joint Venture (JV) / RegisteredSociety / Registered Trust / Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP) etc. The tenderer(s) shallenclose the attested copies of the constitution of their concern,and copy of PAN Card along with their tender. TenderDocuments in such cases are to be signed by such persons asmay be legally competent to sign them on behalf of the firm,company, association, trust or society, as the case may be. Incase of Partnership firm / Joint Venture (JV) / Hindu UndividedFamily(HUF) / Limited Liability Partnership(LLP)or Partners ofPartnership firm/LLP/etc., the firm should submit the valid Powerof Attorney, Partnership Deed/Article ofAssociation/Memorandum of Association, Board of Resolution,Certificate of Incorporation along with the tender. If the firm issole proprietor firm, the bidder should submit the supportingdocument of sole proprietorship firm.
tenderer should quote his offer along with GST and other taxes
For all the tenders having advertised cost of Rs 10 lakh orabove, the contractor shall have the option to take paymentfrom Railways through a letter of credit (LC) arrangement. Thetenderer shall affirm having read over and agreed to the termsand conditions of the LC option. ivThe above option of takingpayment through LC arrangement, once exercised by tendererat the time of bidding, shall be final and no change shall bepermitted, thereafter, during execution of contract. (TheTenderer should be submit his/their opinion for taking paymentthrough letter of credit (LC) arrangement).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The Bid Security shall be rounded off to the nearest 100. ThisBid Security shall be applicable for all modes of tendering. Anyfirm recognized by Department of Industrial Policy andPromotion (DIPP) as 'Startups' shall be exempted from paymentof Bid Security detailed above. Labour Cooperative Societiesshall submit only 50% of above Bid Security detailed above.Subject to exemptions provided above document, the tendermust be accompanied by a Bid Security as mentioned, failingwhich the tender shall be summarily rejected.
The tenderer shall submit along with the tender document,documents in support of his/their claim to fulfill the eligibilitycriteria as mentioned in the tender document. Each page of thecopy of documents/certificates in support of credentials,submitted by the tenderer, shall be self- attested/digitally signedby the tenderer or authorized representative of the tenderingfirm. Self-attestation shall include signature, stamp and date (oneach page). Only those documents which are declared explicitlyby the tenderer as "documents supporting the claim ofqualifying the laid down eligibility criteria", will be considered forevaluating his/their tender
A certificate may be uploaded along with the offer that theTenderer(s) has/have gone through all the conditions of contractand rates, specifications, etc. embodied in Indian RailwayStandard General Condition of Contract-2022 with correctionSlips up to the date of closing of the tender.
1.The Railway reserves the right to verify all statements,information and documents submitted by the bidder in histender offer, and the bidder shall, when so required by theRailway, make available all such information, evidence anddocuments as may be necessary for such verification. Any suchverification or lack of such verification, by the Railway shall notrelieve the bidder of its obligations or liabilities hereunder norwill it affect any rights of the Railway there under. 2.a) In case ofany information submitted by tenderer is found to be falseforged or incorrect at any time during process for evaluation oftenders, it shall lead to forfeiture of the tender Bid Securitybesides banning of business for a period of upto two years. (b) Incase of any information submitted by tenderer is found to befalse forged or incorrect after the award of contract, the contractshall be terminated. Bid Security, Performance Guarantee andSecurity Deposit available with the railway shall be forfeited. Inaddition, other dues of the contractor, if any, under this contractshall be forfeited and agency shall be banned for doing businessfor a period of upto two years.
FAMILARISATION: Tenderer should visit the site of the aboveworks and have familiarized him self/them selves of the workingconditions therein in all respects and in particular the following:1. Topography of the area, 2. Conditions at the site of work, 3.Availability of local labour, both skilled and un skilled and theprevailing labour rate, 4. Availability of Water and Electricity, 5.The existing roads and access to the site of work, 6. Availabilityof space for putting labour camps, offices, stores, go down,engineering yard etc. NOTE: The FAMILARISATION certificateshall be submitted by the tenderer as per format attached atAnnexures.
The tenderer should go through all the eligibility conditions (likeSpecial Technical Criteria, Standard Technical Criteria, StandardFinancial criterial etc.) as mentioned in the document andsubmit relevant documents and fill the enclosedformats/annexures in support of the condition. All thedocuments should be in legible format
Replacement of Numerical relay panel at DMK and HT Capacitor Banks at TXD, SMLG, AGZ, PDU and VZM TSSs .
VSKP-TRD-75-25-26DT310826~SCOR
VSKP-TRD-75-25-26DT310826
Open
Works - General
11 Months
Visakhapatnam, Andhra Pradesh
₹0
₹8.6 L
31 Aug 2026
31 Aug 2026
11 Sept 2026
314 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,31,45,574 | ||
| — | 50.00 | — | — | ||
| Supply and erection of copper strips for equipment earthing.- Supply: | — | — | — | 46,650 | |
| — | 50.00 | — | — | ||
| Supply and erection of copper strips for equipment earthing.-Erection:- | — | — | — | 6,050 | |
| — | 5.00 | — | — | ||
| "Supply without Insulator and erection of 25 kV post Insulator -Supply: | — | — | — | 4,155 | |
| — | 5.00 | — | — | ||
| Supply without Insulator and erection of 25 kV pOSt Insulator -Erection : | — | — | — | 2,070 | |
| — | 2.00 | — | — | ||
| Extra on errection rate for work under a power Block(100% extra) | — | — | — | 828 | |
| — | 5.00 | — | — | ||
| Supply of 25 kV Post Insulator for Item 11 (b) | — | — | — | 36,990 | |
| — | 5.00 | — | — | ||
| Design and drawing for shunt capacitor banks | — | — | — | 1,78,675 | |
| — | 5.00 | — | — | ||
| Extra for erection of Interlocking mechanism | — | — | — | 1,980 | |
| — | 15.00 | — | — | ||
| Concrete for foundation & trench in hard soil-supply: | — | — | — | 72,825 | |
| — | 15.00 | — | — | ||
| Concrete for foundation & trench in hard soil- Erection :- | — | — | — | 40,560 | |
| — | 15.00 | — | — | ||
| Concrete for foundation & trench in rock.-supply | — | — | — | 75,075 | |
| — | 15.00 | — | — | ||
| Concrete for foundation & trench in rock.-Erection | — | — | — | 51,930 | |
| — | 150.00 | — | — | ||
| "Concrete for foundation & trench other than hardsoil & rock.-supply:- | — | — | — | 7,29,750 | |
| — | 150.00 | — | — | ||
| "Concrete for foundation & trench other than hardsoil & rock.-Erection | — | — | — | 2,99,100 | |
| — | 30.00 | — | — | ||
| Reinforced concrete for foundation & trench-Supply:- | — | — | — | 1,70,280 | |
| — | 30.00 | — | — | ||
| Reinforced concrete for foundation & trench.-Erection :- | — | — | — | 73,140 | |
| — | 100.00 | — | — | ||
| Cable trench coversSupply:- | — | — | — | 1,91,100 | |
| — | 100.00 | — | — | ||
| Cable trench covers-Erection:- | — | — | — | 82,100 | |
| — | 100.00 | — | — | ||
| Supply & spreading of Ballast/Gravel in the switch Yard. Supply:- | — | — | — | 1,59,400 | |
| — | 100.00 | — | — | ||
| Supply & spreading of Ballast/Gravel in the switchYard. -Erection | — | — | — | 1,700 | |
| — | 5.00 | — | — | ||
| Supply of 25 kV Post & Operating Rod Insulators for item No. 10(a) '" | — | — | — | 96,155 | |
| — | 30.00 | — | — | ||
| Supply & Erection of 25 kV Support Insulator-Supply:- | — | — | — | 2,26,920 | |
| — | 30.00 | — | — | ||
| Supply & Erection of 25 kV Support Insulator.-Erection:- | — | — | — | 9,990 | |
| — | 6.00 | — | — | ||
| "Supply and Erection of Fabricated & Galvanised Steel Structures f o r L T Supply Transformer, Equipment Supporting Structures e t c . for TSS/Switching Stations (Special Steel Structures Other than Portals andMasts)-Supply:- | — | — | — | 8,13,210 | |
| — | 6.00 | — | — | ||
| "Supply and Erection of Fabricated & Galvanised Steel Structures f o r L T Supply Transformer, Equipment Supporting Structures e t c . for TSS/Switching Stations (Special Steel Structures Other than Portals andMasts)-Erection:- | — | — | — | 26,166 | |
| — | 3.00 | — | — | ||
| Extra on errection rate for work under a power Block(100% extra) | — | — | — | 13,083 | |
| — | 5.00 | — | — | ||
| Supply (without Insulator) and Erection of 25kV Single Pole Isolators (1600A) -Supply:- | — | — | — | 2,42,875 | |
| — | 5.00 | — | — | ||
| Supply (without Erection:- | — | — | — | 17,225 | |
| — | — | — | Isolators | ||
| — | 25.00 | — | — | ||
| Earth Electrode-Supply | — | — | — | 94,000 | |
| — | 25.00 | — | — | ||
| Earth Electrode: Erection | — | — | — | 60,475 | |
| — | 75.00 | — | — | ||
| "Earth Leads 75mm X 8mm Mild Steel Laid in the Ground-supply:- " | — | — | — | 26,250 | |
| — | 75.00 | — | — | ||
| "Earth Leads 75mm X 8mm Mild Steel Laid in the Ground. Erection:- " | — | — | — | 10,350 | |
| — | 200.00 | — | — | ||
| "Earth Leads 50mm X 6mm Mild Steel Laid in theGround. Supply:- | — | — | — | 34,400 | |
| — | 200.00 | — | — | ||
| "Earth Leads 50mm X 6mm Mild Steel Laid in theGround. Erection:- | — | — | — | 19,800 | |
| — | 75.00 | — | — | ||
| "Earth Leads75 mmx8mm Mild steel flat laid Exposed.Supply:- | — | — | — | 26,250 | |
| — | 75.00 | — | — | ||
| "Earth Leads75 mmx8mm Mild steel flat laid Exposed. Erection:- | — | — | — | 7,425 | |
| — | 150.00 | — | — | ||
| "Earth Leads 50mm X 6mm Mild Steel Flat LaidExposed. Supply:- | — | — | — | 25,800 | |
| — | 150.00 | — | — | ||
| "Earth Leads 50mm X 6mm Mild Steel Flat LaidExposed. Erection:- | — | — | — | 12,600 | |
| — | 20.00 | — | — | ||
| 8 SWG G.I Wire for Earthing- Supply:- | — | — | — | 720 | |
| — | 20.00 | — | — | ||
| 8 SWG G.I Wire for Earthing -Erection:- | — | — | — | 620 | |
| — | 200.00 | — | — | ||
| Supply & Erection of Earth Screen Wires-Supply:- | — | — | — | 76,400 | |
| — | 200.00 | — | — | ||
| Supply & Erection of Earth Screen Wires Erection:- | — | — | — | 5,800 | |
| — | 90.00 | — | — | ||
| "Supply & Erection of Tubular Aluminium BusbarS50x39mm Dia.Supply:- | — | — | — | 99,000 | |
| — | 90.00 | — | — | ||
| "Supply & Erection of Tubular Aluminium BusbarS50x39mm Dia. Erection:- | — | — | — | 9,450 | |
| — | 20.00 | — | — | ||
| "Supply & Erection o f Rigid Bimetallic Terminal Connector Suitable f o r 5 0 Dia Aluminium Tubular Busbar To Terminal Pad of 25kV Isolator/CT(RI-11090).Supply:- | — | — | — | 73,600 | |
| — | 20.00 | — | — | ||
| "Supply & Erection o f Rigid Bimetallic Terminal Connector Suitable f o r 5 0 Dia Aluminium Tubular Busbar To Terminal Pad of 25kV Isolator/CT(RI-11090).Erection :- | — | — | — | 1,240 | |
| — | 20.00 | — | — | ||
| Supply & Erection of Expansion Type Terminal Connector To Suit 50 Dia Aluminium Tubular Busbar, Terminal Pad of 25kV CT/Isolator (RI-11060). -supply:- | — | — | — | 1,31,100 | |
| — | 20.00 | — | — | ||
| Supply & Erection of Expansion Type Terminal Connector To Suit 50 Dia Aluminium Tubular Busbar, Terminal Pad of 25kV CT/Isolator (RI-11060). -Erection:- | — | — | — | 1,240 | |
| — | 10.00 | — | — | ||
| "Supply & Erection o f 2 5 k V System Rigid B u s SpliceConnector T o S u i t 5 0 O/D Aluminium Tube On Both Ways (RI-11180)." | — | — | — | 34,970 | |
| — | 10.00 | — | — | ||
| "Supply & Erection o f 2 5 k V System Rigid B u s SpliceConnector T o S u i t 5 0 O/D Aluminium Tube On Both Ways (RI-11180).Erection:- | — | — | — | 620 | |
| — | 10.00 | — | — | ||
| "Supply & Erection of 25kV System TEE Connector ToSuit 50 O/D Aluminium Tubular Busbar (RI-11150).Supply:- | — | — | — | 34,980 | |
| — | 10.00 | — | — | ||
| "Supply & Erection of 25kV System TEE Connector ToSuit 50 O/D Aluminium Tubular Busbar (RI-11150).Erection | — | — | — | 620 | |
| — | 10.00 | — | — | ||
| "Supply & Erection of Rigid Through Connector To Suit50 D i a Aluminium Tubular Busbar & SPIDER AAC Conductor for 25kV P.T. Type-II (RI-11110).Supply:- | — | — | — | 31,670 | |
| — | 10.00 | — | — | ||
| "Supply & Erection of Rigid Through Connector To Suit50 D i a Aluminium Tubular Busbar & SPIDER AAC Conductor for 25kV P.T. Type-II (RI-11110).Erection:- | — | — | — | 620 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 25kV System Expansion BuSCoupler On SI To Suit 50 O/D AI. Tube (RI-11210) Supply:_ | — | — | — | 38,935 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 25kV System Expansion BuSCoupler On SI To Suit 50 O/D AI. Tube (RI-11210).Erection:- | — | — | — | 310 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 25kV System Tee Connector ToSuit 50, O/D Aluminium Tubular Spider AAC Conductor (RI-11140).Supply:- | — | — | — | 15,955 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 25kV System Tee Connector ToSuit 50, O/D Aluminium Tubular Spider AAC Conductor (RI-11140).Erection:- | — | — | — | 310 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of Rigid Connector On SI To Suit 50Mm O/D AI. Bus Bar (RI- 11200).Supply:- | — | — | — | 6,875 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of Rigid Connector On SI To Suit 50Mm O/D AI. Bus Bar (RI-11200) Erection:- | — | — | — | 310 | |
| — | 25.00 | — | — | ||
| "Supply & Erection of Sliding Clamp for 50mm O/D ALBus Bar (RI-11190).Supply:- | — | — | — | 50,700 | |
| — | 25.00 | — | — | ||
| "Supply & Erection of Sliding Clamp for 50mm O/D ALBus Bar (RI-11190).Erection:- | — | — | — | 1,550 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 25kV System TEE Connector To Suit 3 6 O / D A I . B u s B a r To 50mm O/D AI. Bus Bar(RI-11240)SUPPLY:- | — | — | — | 17,785 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 25kV System TEE Connector To Suit 3 6 O / D A I . B u s B a r To 50mm O/D AI. Bus Bar(RI-11240).Erection :- | — | — | — | 310 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36 Mm Aluminium Bus Terminal(for 25 kV Isolator Rigid Type) (RI-6480)-supply:- | — | — | — | 18,345 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36 Mm Aluminium Bus Terminal(for 25 kV Isolator Rigid Type) (RI-6480) ERECTION | — | — | — | 360 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36 Mm Aluminium Bus Splice(RI-6490) SUPPLY:- " | — | — | — | 14,920 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36 Mm Aluminium Bus Splice(RI-6490) "Erection:- | — | — | — | 345 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36 Mm Aluminium Bus TeeConnector (RI-6500)-supply:- | — | — | — | 15,015 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36 Mm Aluminium Bus TeeConnector (RI-6500)-Erection:- | — | — | — | 335 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36/20 Mm Terminal Connector(RI-6530)-Supply:- | — | — | — | 13,385 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36/20 Mm Terminal Connector(RI-6530)Erection:- | — | — | — | 335 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36/15 Mm Tap Connector(RI-6520)"-Supply:- | — | — | — | 13,855 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of 36/15 Mm Tap Connector(RI-6520)Erection:- | — | — | — | 345 | |
| — | 5.00 | — | — | ||
| Supply & Erection of 36 Mm Aluminium Flexible Bus Splice (RI-6550)-Supply:- | — | — | — | 58,925 | |
| — | 5.00 | — | — | ||
| Supply & Erection of 36 Mm Aluminium Flexible Bus Splice (RI-6550)-Erection:- | — | — | — | 345 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of Terminal Connector rAluminium Conductors (Bolted Type) (RI : 6830-1)-supply:- | — | — | — | 9,545 | |
| — | 5.00 | — | — | ||
| "Supply & Erection of Terminal Connector rAluminium Conductors (Bolted Type) (RI : 6830-1)Erection:- | — | — | — | 335 | |
| — | 20.00 | — | — | ||
| "Supply & Erection of Tubular Aluminium Busbar 36mm x 28 mm"-Supply:- | — | — | — | 11,040 | |
| — | 20.00 | — | — | ||
| "Supply & Erection of Tubular Aluminium Busbar 36mm x 28 mm"-ERECTION:- | — | — | — | 2,420 | |
| — | 10.00 | — | — | ||
| Supply & Erection of Aluminium Jumper-SUPPLY:- | — | — | — | 28,710 | |
| — | 10.00 | — | — | ||
| Supply & Erection of Aluminium Jumper-ERECTION:- | — | — | — | 3,930 | |
| — | 10.00 | — | — | ||
| Supply & Erection of Copper Jumper: SUPPLY:- | — | — | — | 2,850 | |
| — | 10.00 | — | — | ||
| Supply & Erection of Copper Jumper-ERECTION | — | — | — | 5,890 | |
| — | 7.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of 25 kVSingle Pole Vacuum Circuit Breaker.-SUPPLY:- | — | — | — | 37,43,320 | |
| — | 7.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of 25 kVSingle Pole Vacuum Circuit Breaker-Erection:- | — | — | — | 72,681 | |
| — | 4.00 | — | — | ||
| Extra on errection rate for work under a power Block(100% extra) | — | — | — | 41,532 | |
| — | 7.00 | — | — | ||
| Supply & Erection of 25 kV P.T.(Type-ll)-supply:- | — | — | — | 5,96,218 | |
| — | 7.00 | — | — | ||
| Supply & Erection of 25 kV P.T.(Type-ll)-Erection:- | — | — | — | 7,532 | |
| — | 3.00 | — | — | ||
| Extra on errection rate for work under a power Block(100% extra) | — | — | — | 3,228 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of Control& Relay Panel (Board) for 25 kV TSS"-Supply:- | — | — | — | 62,98,090 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of Control& Relay Panel (Board) for 25 kV TSS"-Erection:- | — | — | — | 26,889 | |
| — | 5.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of Control& Relay Panel for 27 kV Shunt Capacitor Bank-Supply: | — | — | — | 70,69,555 | |
| — | 5.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of Control& Relay Panel for 27 kV Shunt Capacitor Bank Erection:- | — | — | — | 1,34,445 | |
| — | 5.00 | — | — | ||
| Supply & Erection of 25 kV Lightning Arrestors (42kV LA)-Supply:- | — | — | — | 2,19,290 | |
| — | 5.00 | — | — | ||
| Supply & Erection of 25 kV Lightning Arrestors (42kV LA)-Erection:- | — | — | — | 4,995 | |
| — | 4.00 | — | — | ||
| Extra on errection rate for work under a power Block(100% extra) | — | — | — | 3,996 | |
| — | 1.00 | — | — | ||
| "Supply & Erection of 240V L.T. Distribution Boards in The Control Room for 2 5 kVa L.T SupplyTransformer.Supply:- | — | — | — | 94,734 | |
| — | 1.00 | — | — | ||
| "Supply & Erection of 240V L.T. Distribution Boards in The Control Room for 2 5 kVa L.T SupplyTransformer.Erection:- | — | — | — | 1,713 | |
| — | 1.00 | — | — | ||
| Supply & Erection of 110V DC Distribution Boards.-Supply:- | — | — | — | 49,945 | |
| — | 1.00 | — | — | ||
| Supply & Erection of 110V DC Distribution Boards -Erection:- | — | — | — | 1,219 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of ShuntCapacitor Banks of 2200kVAR"- Supply:- | — | — | — | 5,14,785 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning o f ShuntCapacitor Banks of 2200kVAR Erection:- | — | — | — | 35,827 | |
| — | 3.00 | — | — | ||
| " S u p p l y , E r e c t io n , Te s t i n g & 3300kVAR"Supply:- | — | — | — | 20,03,979 | |
| — | 3.00 | — | — | ||
| " S u p p l y , E r e c t io n , Te s t i n g & 3300kVAR"Erection:- | — | — | — | 1,07,481 | |
| — | 3.00 | — | — | ||
| Supply, Erection, Testing & Commissioning o f Low Loss Series Reactor Suitable for 25kV Shunt Capacitor Banks of 2200kVAR at 40 kV-Supply:- | — | — | — | 26,44,449 | |
| — | 3.00 | — | — | ||
| Supply, Erection, Testing & Commissioning o f Low Loss Series Reactor Suitable for 25kV Shunt Capacitor Banks of 2200kVAR at 40 kV-Erection:- | — | — | — | 1,03,503 | |
| — | 4.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of Low Loss Series Reactor Suitable for 25 kV ShuntCapacitor Banks of 3300 kVAR at 40 kV "Supply:- | — | — | — | 37,52,744 | |
| — | 4.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of Low Loss Series Reactor Suitable for 25 kV ShuntCapacitor Banks of 3300 kVAR at 40 kV - "Erection:- | — | — | — | 1,38,004 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of ShuntCapacitor Banks of 8800 kVAR at 40 kV "Supply:- | — | — | — | 14,75,000 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of ShuntCapacitor Banks of 8800 kVAR at 40 kV -Erection :- " | — | — | — | 35,827 | |
| — | 1.00 | — | — | ||
| " S u p p l y , E r e c t io n , Te s t i n g & 5500kVAR"Supply:- | — | — | — | 11,15,196 | |
| — | 1.00 | — | — | ||
| " S u p p l y , E r e c t io n , Te s t i n g & 5500kVAR"Erection:- | — | — | — | 35,827 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning o f LowLoss Series Reactor Suitable for 25kV Shunt Capacitor Banks of 5500kVAR at 40 kV"-Supply:- | — | — | — | 11,77,170 | |
| — | 1.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning o f LowLoss Series Reactor Suitable for 25kV Shunt Capacitor Banks of 5500kVAR at 40 kV"Erection | — | — | — | 34,501 | |
| — | 1.00 | — | — | ||
| Supply and erection of Low loss series reactor suitable for shunt capacitor bank, capacity 4400KVAR at 40KVSupply:- | — | — | — | 11,47,432 | |
| — | 1.00 | — | — | ||
| Supply and erection of Low loss series reactor suitable for shunt capacitor bank, capacity 4400KVAR at 40KVErection:- | — | — | — | 34,501 | |
| — | 1.00 | — | — | ||
| Supply,erection ,testing and commissioning of low loss series reactor with complete assembly to match 6600KVAR Capacitor bank | — | — | — | 13,43,417 | |
| — | 15.00 | — | — | ||
| Supply, erection, testing and commissioning of Shunt Capacitor 220 KVAR, 8 KV, 10.95 Micro Farad, Single Phase 50 Hz as per RDSO Spec. TI/SPC/PSI/FC & SR/0100(01/10) with A & C slip no.1 or latest with all accessories and fittings including support structures | — | — | — | 4,63,386 | |
| — | 6.00 | — | — | ||
| "Supply & Erection of 25 kV Current Transformers(200-100/5A)"Supply:- | — | — | — | 5,27,322 | |
| — | 6.00 | — | — | ||
| "Supply & Erection of 25 kV Current Transformers(200-100/5A)"Erection:- | — | — | — | 21,846 | |
| — | 1.00 | — | — | ||
| "Supply & Erection of 25 kV Current Transformers(400-200/5A)" | — | — | — | 87,887 | |
| — | 1.00 | — | — | ||
| "Supply & Erection of 25 kV Current Transformers(400-200/5A)"Erection:- | — | — | — | 3,641 | |
| — | 7.00 | — | — | ||
| "Supply & Erection of 25 kV Neutral CurrentTransformers."Supply:- | — | — | — | 7,29,512 | |
| — | 7.00 | — | — | ||
| "Supply & Erection of 25 kV Neutral CurrentTransformers."Erection:- | — | — | — | 24,815 | |
| — | 700.00 | — | — | ||
| "Supply and installation of cable for Circuit Breakers & interrupter Control and indication Circuits. (7x2.5 Sq.mm Copper)"Supply:- | — | — | — | 2,27,500 | |
| — | 700.00 | — | — | ||
| "Supply and installation of cable for Circuit Breakers & interrupter Control and indication Circuits. (7x2.5 Sq.mm Copper)"Erection:- | — | — | — | 20,300 | |
| — | 300.00 | — | — | ||
| "Supply and installation o f cable for TransformerAlarm/Trip Circuits & Ta p Changer Control.(10x2.5 Sq. mm Copper)"Supply:- | — | — | — | 1,36,200 | |
| — | 300.00 | — | — | ||
| "Supply and installation o f cable for TransformerAlarm/Trip Circuits & Ta p Changer Control.(10x2.5 Sq. mm Copper)"Erection:- | — | — | — | 9,300 | |
| — | 300.00 | — | — | ||
| "Supply a n d installation o f cable f o r Transformer Bushing CT Circuits & 110V DC Circuits.(4x4 Sq. mmCopper) "Supply:- | — | — | — | 91,800 | |
| — | 300.00 | — | — | ||
| "Supply a n d installation o f cable f o r Transformer Bushing CT Circuits & 110V DC Circuits.(4x4 Sq. mmCopper) "Erection:- | — | — | — | 9,300 | |
| — | 800.00 | — | — | ||
| Supply and installation of cable for Current Transformer Circuits 110V DC & 240V AC Supply Circuits. (2x4 Sq. mm Copper)Supply:- | — | — | — | 1,38,400 | |
| — | 800.00 | — | — | ||
| Supply and installation of cable for Current Transformer Circuits 110V DC & 240V AC Supply Circuits. (2x4 Sq. mm Copper)Erection:- | — | — | — | 24,800 | |
| — | 500.00 | — | — | ||
| Supply and installation of cable for Potential Transformer and 240V AC Supply Circuits (2x2.5 Sq.mm Copper)Supply:- | — | — | — | 60,000 | |
| — | 500.00 | — | — | ||
| Supply and installation of cable for Potential Transformer and 240V AC Supply Circuits (2x2.5 Sq.mm Copper)Erection:- | — | — | — | 12,500 | |
| — | 500.00 | — | — | ||
| " S u p p l y a n d installation o f c a b l e f o r 2 4 0 V Aluminium)"Supply:- | — | — | — | 46,500 | |
| — | 500.00 | — | — | ||
| " S u p p l y a n d installation o f c a b l e f o r 2 4 0 V Aluminium)"Erection:- | — | — | — | 11,500 | |
| — | 5.00 | — | — | ||
| Dismantling of an Isolator. | — | — | — | 11,965 | |
| — | 20.00 | — | — | ||
| Dismantling of a Post/ Pedestal Insulator. | — | — | — | 15,220 | |
| — | 5.00 | — | — | ||
| Dismantling of supporting beams, channels, outriggers, masts, supporting structures from solid core foundation, other SPS with fasteners etc | — | — | — | 23,260 | |
| — | 5.00 | — | — | ||
| Dismantling of 25 KV PT II | — | — | — | 2,935 | |
| — | 5.00 | — | — | ||
| Dismantling of Current Transformer | — | — | — | 2,805 | |
| — | 5.00 | — | — | ||
| Dismantling of Circuit Breakers | — | — | — | 26,640 | |
| — | 5.00 | — | — | ||
| Dismantling of Series Reactor | — | — | — | 3,65,330 | |
| — | 5.00 | — | — | ||
| Dismantling of Shunt Capacitor Bank | — | — | — | 3,02,005 | |
| — | 5.00 | — | — | ||
| Dismantling of Neutral Current Transformers | — | — | — | 15,100 | |
| — | 5.00 | — | — | ||
| Dismantling of Lightening arrestors | — | — | — | 1,080 | |
| — | 50.00 | — | — | ||
| Dismantling of MS flat | — | — | — | 2,700 | |
| — | 80.00 | — | — | ||
| Dismantling of AL tubular Bus bar | — | — | — | 2,960 | |
| — | 40.00 | — | — | ||
| Dismantling of Various connectors ( Al Bus bar T-Connector, Bus Bar Splice, T- Terminals, Tap connector & Control and indication circuit, cables etc.) | — | — | — | 920 | |
| — | 20.00 | — | — | ||
| Dismantling of concrete foundations / Muffings etc. | — | — | — | 99,980 | |
| — | 200.00 | — | — | ||
| Dismantling of various sizes of cables | — | — | — | 1,800 | |
| — | 10.00 | — | — | ||
| retrieval of fencing up rights & masts | — | — | — | 20,360 | |
| — | 6.00 | — | — | ||
| Dismantling and shifting of existing control relay panel and keeping at suitable place /consignee place as directed by the engineer incharge | — | — | — | 30,558 | |
| — | 20.00 | — | — | ||
| Dismantlaing of Fencing pannels and gate with anticlimbing device with fastners | — | — | — | 2,380 | |
| — | 5.00 | — | — | ||
| Supply of Power Meter for Monitoring and Recording the Voltage, Current, Power Factor model PM172EN, | — | — | — | 6,77,790 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ANNEXUREVVA.pdf
ATTACHMENT
ANNEXURE-1.pdf
ATTACHMENT
SCOPEOFWORK.pdf
ATTACHMENT
TenderConditions.pdf
ATTACHMENT
GCC20221.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .