Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC 14 15 A CHANDU MASTER ROAD VISHNUPURAM CHERANALLOOR ERNAKULAM KERALA 682034 | ERNAKULAM | KERALA | 682034 | ₹5.9 L | L1 | Accepted-AOC Bidder technically and financially qualified |
| 2 | L2₹6.1 L+₹29,631 (5.06%)Rejected-Finance | ₹6.1 L+₹29,631 (5.06%) | L2 | Rejected-Finance Financially not lowest |
| 3 | L3₹6.6 L+₹73,256 (12.5%)Rejected-Finance | ₹6.6 L+₹73,256 (12.5%) | L3 | Rejected-Finance Financially not lowest |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
Tender Value
Refer Docs
EMD Value
₹13,640
Closing Date
12 Jul 2021, 4:00 pmClosed
SUPERINTENDING ENGINEER
ENGINEERING SECTION, IISER, MARUTHAMALA.P.O,VITHURA, THIRUVANANTHAPURAM
AMC for Fire Fighting, Fire alarm and Public Addressing systems, refilling of fire extinguishers installed in IISER TVM campus
2021_IISRT_636666_1
IISERTVM/EO/EM/101W/05/21-22
Open Tender
Support/Maintenance Service
Works
365 days
IISER
Please refer Tender documents.
4 documents required · 4 mandatory
₹560
IISER,THIRUVANANTHAPURAM
₹13,640
17 Aug 2021
2 Jul 2021
13 Jul 2021
3 Jul 2021
12 Jul 2021
3 Jul 2021
Amount
Periodical Maintenance Services under Annual Maintenance Contract for Fire Fighting, Fire Alarm, Public Address system in various buildings at IISER Thiruvananthapuram as per scope of work complete as required and as directed by the EIC
Servicing and Refilling of stored pressure Dry Chemical Powder type (ABC Stored Pressure Type) fire extinguishers with Mono Ammonium Phosphate based dry chemical powder (MAP min 90%) & Hygroscopicity less than 1.5% confirming to IS: 14609, IS 15683:2006 capable of fighting class A, B, C types of fires with Dry Nitrogen based propellant 15Kg/Cm2 as required. If necessary as per the site condition the fire extinguisher shall be provided with accessories/spares like Pressure Gauge, Safety Pin, Bracket, Valve assembly, Horn & Hose etc. complete for safe operation as per IS standards, Instruction sticker, scratching off rusts and repainting with suitable shade confirming to IS: 2932) and fixing on wall and transportation complete in all aspects as per IS: 2190 as directed by EIC. (The operating temperature range, Net weight, the effective discharge time & throw, Expiry date shall be clearly mentioned in the extinguisher.)
4kg (ABC)
6kg (ABC)
9kg (ABC)
50kg (ABC)
10 kg (ABC) with sprinkler head modular automatic
Servicing and Refilling of stored pressure Dry Chemical Powder type fire extinguishers with Sodium-Bi-Carbonate (SBC) suitable for B and C Class Fire (as per IS:4308 latest revision, IS:15683),with gas cartridge having Propellant of 120 grams CO2 stored as per IS: 4947, having a Minimum Effective Discharge Time of 8seconds. All the extinguisher shall be Hydraulic Pressure Testing as per IS: 2190. If necessary as per the site condition the fire extinguisher shall be provided with accessories/spares like Pressure Gauge, Safety Pin, Bracket, Valve assembly, Horn & Hose etc. complete for safe operation as per IS standards, repainting with suitable shade confirming to IS: 2932, Labour cost, transportation complete as required including all the taxes complete in all aspects as directed by EIC. (The operating temperature range, Net weight, the effective discharge time & throw shall be clearly mentioned in the extinguisher.)
6 kg ( BC Type )
Servicing and Refilling of existing CO2 based Fire Extinguisher of following capacity at various location at IISER Campus with carbon dioxide gas conforming to IS:15222, IS:2190,IS: 2878,IS:15683 if necessary It shall have anti corrosive treatment as per IS 3203. The extinguisher shall be clearly and permanently marked in accordance with IS: 940(latest amendment), repainting with suitable shade confirming to IS: 2932.etc complete in all aspects as directed by EIC. (The operating temperature range, Net weight, the effective discharge time & throw, Expiry date shall be clearly mentioned in the extinguisher.)
Servicing and Refilling of existing stored pressure Fire Extinguisher of Water (3A type fire) /with Gas cartridge having Propellant of 120 grams CO2 stored according to IS 4947, IS: 15683, it shall have a minimum effective discharge Time 13 Seconds and shall be moisture free and 99% pure and shall conform to the requirement of IS 15222. If necessary it shall have an Epoxy powder coating of 50 microns thickness shall be applied on external surface of the body as per IS 3203 . The extinguisher shall be clearly and permanently marked in accordance with IS: 940 (latest amendment).etc. complete in all aspects as directed by EIC. (The operating temperature range, Net weight, the effective discharge time & throw, Expiry date shall be clearly mentioned in the extinguisher.)
9 liter
Servicing and Refilling of Fire Extinguisher of Foam (AFFF-6% for A and B Class Fire), type as per the relevent IS standard. If necessary it shall have an Epoxy powder coating of 50 microns thickness shall be applied on external surface of the body as per IS 3203 . The extinguisher shall be clearly and permanently marked in accordance with IS: 940 (latest amendment).etc. complete in all aspects as directed by EIC. (The operating temperature range, Net weight, the effective discharge time & throw, Expiry date shall be clearly mentioned in the extinguisher.)
9 liter
ESCORTS ENGINEERS PVT LTD
SPARK FIRE SAFETY EQUIPMENTS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .