Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | ₹18.3 L Quoted ₹19.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹21.7 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹21.7 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹22.5 LRejected-Finance | ₹22.5 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹23.6 LRejected-Finance | ₹23.6 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹25.9 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹25.9 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | JAYESH TRADING CORPORATION L2 | JAMNAGAR ELECTRIC AND MACHINERY CO L7 | M/s Jagdish Machinery Stores L10 | Jyoti Refrigeration L4 | M/s.Bhavin Electricals L8 | J J ENTERPRISE L3 | fakhrie apostrical L9 | MADHAV ENTERPRISE L11 | M/s Balaji Enterprise L1 | Hirachand Sunderji and co L6 | BHAVNA IMPERIAL ENTERPRISE L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Notes applicable to all items of BOQ :- (i) The contractor shall check the fittings / fixtures and wiring as per the complaint given by the Engineer-in-Charge / concerned JE. Spares being replaced shall be intimated by JE and the replaced spares shall be measured and paid under respective items of BOQ and no extra payment will be done for the same. (ii) It is the responsibility of the Contractor to ensure that day to day complaints slips are collected every morning before distributing labours from JE from MES service centre and attend & complete the complaints the same day irrespective of any number of complaints and return back the complaint slip duly signed by the User to JE the same evening as a token of complaint rectified as such contractor to make all arrangements including supply of materials required for attending complaints without any delay, the quoted rate against various items shall deemed to be inclusive of above aspects. | ||||||||||||||
| 1.01 | Taking down existing batten type light fitting of any description & fixed in any position and S&F new clear white 20 Watt wall mounted 4 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. | 1,350 | Each | 360 ₹4.9 L | 545 ₹7.4 L | 512 ₹6.9 L | 395 ₹5.3 L | 390 ₹5.3 L | 375 ₹5.1 L | 450 ₹6.1 L | 550 ₹7.4 L | 350 ₹4.7 L | 495 ₹6.7 L | 310 ₹4.2 L |
| 2.00 | Taking down existing batten type light fitting of any description & fixed in any position and S&F new clear white 10 Watt wall mounted 2 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. | 380 | Each | 295 ₹1.1 L | 435 ₹1.7 L | 452 ₹1.7 L | 360 ₹1.4 L | 300 ₹1.1 L | 290 ₹1.1 L | 320 ₹1.2 L | 420 ₹1.6 L | 290 ₹1.1 L | 450 ₹1.7 L | 250 ₹95,000 |
| 3.00 | S&F in repairs 9 Watt LED Bulb (Non-dimmable) warm white fixed at site and testing after completion complete all as specified and as directed. | 20 | Each | 125 ₹2,500 | 94 ₹1,880 | 85 ₹1,700 | 110 ₹2,200 | 88 ₹1,760 | 120 ₹2,400 | 140 ₹2,800 | 130 ₹2,600 | 70 ₹1,400 | 85 ₹1,700 | 60 ₹1,200 |
| 4.00 | Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, fixed over & including mounting bracket made of 32mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed. | 52 | Each | 2,250 ₹1.2 L | 3,025 ₹1.6 L | 2,865 ₹1.5 L | 2,840 ₹1.5 L | 2,400 ₹1.2 L | 2,300 ₹1.2 L | 2,600 ₹1.4 L | 3,100 ₹1.6 L | 2,100 ₹1.1 L | 4,500 ₹2.3 L | 1,720 ₹89,440 |
| 5.00 | Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 45 Watt LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 2ft x 2ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. | 15 | Each | 2,450 ₹36,750 | 2,145 ₹32,175 | 1,865 ₹27,975 | 1,860 ₹27,900 | 2,800 ₹42,000 | 2,550 ₹38,250 | 3,000 ₹45,000 | 2,800 ₹42,000 | 1,900 ₹28,500 | 2,150 ₹32,250 | 2,275 ₹34,125 |
| 6.00 | Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 36/40 Watt LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 2ft x 2ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. | 70 | Each | 2,450 ₹1.7 L | 2,365 ₹1.7 L | 2,654 ₹1.9 L | 2,160 ₹1.5 L | 1,750 ₹1.2 L | 2,100 ₹1.5 L | 2,300 ₹1.6 L | 2,600 ₹1.8 L | 1,878 ₹1.3 L | 2,240 ₹1.6 L | 1,525 ₹1.1 L |
| 7.00 | Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 33/36 Watt Ultra Slim LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 1ft x 4ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, including suspended accessories etc, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. | 20 | Each | 2,450 ₹49,000 | 2,079 ₹41,580 | 1,990 ₹39,800 | 1,980 ₹39,600 | 2,750 ₹55,000 | 2,300 ₹46,000 | 3,000 ₹60,000 | 2,950 ₹59,000 | 1,700 ₹34,000 | 1,925 ₹38,500 | 2,920 ₹58,400 |
| 8.00 | Taking down existing spot/down light fitting of any type & fixed in any position and S&F new 20 Watt wall/ ceiling mounted deep recessed spotlight COB down light with die cast aluminium housing, clear PMMA/polycarbonate/toughened glass diffuser, minimum CCT 6000K, decorative fixture, fixed in any position on wall/ ceiling by Screw/ nut bolt properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed. | 10 | Each | 1,100 ₹11,000 | 1,496 ₹14,960 | 1,440 ₹14,400 | 1,260 ₹12,600 | 1,300 ₹13,000 | 1,000 ₹10,000 | 850 ₹8,500 | 1,600 ₹16,000 | 1,250 ₹12,500 | 1,350 ₹13,500 | 1,325 ₹13,250 |
| 9.00 | Taking down existing light fitting of any type & fixed in any position and S&F new 2 x 6 Watt LED wall mounted UP and DOWN clear/ warm white decorative LED light fixture with die cast aluminium housing transparent tempered glass diffuser, minimum IP 54 protection, minimum CCT 2700K, fixed in any position on wall with Screw/ nut bolt properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed.
Make : Wipro Cat No. GARNET DW11227, Jaquar Cat No. LWWL02R206XW or equivalent in makes mentioned in Appendix 'B' here-in-after. | 15 | Each | 1,850 ₹27,750 | 2,134 ₹32,010 | 2,000 ₹30,000 | 2,160 ₹32,400 | 1,300 ₹19,500 | 1,700 ₹25,500 | 950 ₹14,250 | 2,600 ₹39,000 | 1,800 ₹27,000 | 2,430 ₹36,450 | 2,725 ₹40,875 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 May 2026, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
Repair/ replacement and maintenance services of Internal wiring, fitting fixtures with day to day complaints to certain Md accn and OTM accn of Zone A area and connected items at INS Valsura, Jamnagar
2026_MES_762410_1
8955/VAL/E8
Open Tender
Electrical and Maintenance Works
335 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹60,000
Yes
25 May 2026
27 Apr 2026
18 May 2026
27 Apr 2026
16 May 2026
11 May 2026
Taking down existing batten type light fitting of any description & fixed in any position and S&F new clear white 20 Watt wall mounted 4 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing batten type light fitting of any description & fixed in any position and S&F new clear white 10 Watt wall mounted 2 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
S&F in repairs 9 Watt LED Bulb (Non-dimmable) warm white fixed at site and testing after completion complete all as specified and as directed.
Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, fixed over & including mounting bracket made of 32mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed.
Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 45 Watt LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 2ft x 2ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 36/40 Watt LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 2ft x 2ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing Recess/ Pendent mounted light fitting of any type & fixed in any position and S&F new clear white 33/36 Watt Ultra Slim LED light fitting, decorative, energy efficient, Recess/ Pendent mounted 1ft x 4ft decorative panel with white powder coated CRCA housing and full mounted acrylic diffuser, flicker free driver, minimum CCT 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.90, 230 Volts, 50 Hz, including suspended accessories etc, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down existing spot/down light fitting of any type & fixed in any position and S&F new 20 Watt wall/ ceiling mounted deep recessed spotlight COB down light with die cast aluminium housing, clear PMMA/polycarbonate/toughened glass diffuser, minimum CCT 6000K, decorative fixture, fixed in any position on wall/ ceiling by Screw/ nut bolt properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed.
Taking down existing light fitting of any type & fixed in any position and S&F new 2 x 6 Watt LED wall mounted UP and DOWN clear/ warm white decorative LED light fixture with die cast aluminium housing transparent tempered glass diffuser, minimum IP 54 protection, minimum CCT 2700K, fixed in any position on wall with Screw/ nut bolt properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed. Make : Wipro Cat No. GARNET DW11227, Jaquar Cat No. LWWL02R206XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
S&F in repairs switch piano, flush type, single pole, one way 5/ 6 Amp, complete all as specified and as directed.
S&F in repairs switch socket combination 2 in 1, 3 pin, 6 Amp, flush type, 240 Volt, complete all as specified and as directed.
S&F in repairs switch socket combination 5 in 1, 6 and 16 Amp, flush type, 240 Volt, complete all as specified and as directed.
S&F in repairs bell push, piano flush type, single pole, 6 Amp, complete all as specified and as directed.
S&F in repairs Bell, Ding Dong type, 230 Volt AC supply, Single Pole, complete all as specified and as directed.
S&F in repairs modular bell push, 6A, 1 module with all accessories complete all as specified and as directed. Make: Legrand Cat No 6755 04 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs modular switch, one way, 6 Amp, 1 module with all accessories complete all as specified and as directed. Make: Legrand Cat No. 6755 01 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs modular switch, one way, 16 Amp, 1 module with all accessories complete all as specified and as directed. Make: Legrand Cat No. 6755 11 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs molular Socket, 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as specified and as directed. Make: Legrand Cat No. 6755 51 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs modular Socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as specified and as directed. Make: Legrand Cat No. 6755 55 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair step type fan regulator 100 W, 2 module, AC, 230V, electronic complete all as specified and as directed. Make: Legrand Cat No. 6755 30 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair step type fan regulator, AC, 230V, electronic on the existing phenolic laminated sheet etc complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, IP-54 rating, SPN, 12 way with 100 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, IP-54 rating, SPN, 8 way with 100 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, IP-54 rating, SPN, 4 way with 100 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, IP-54 rating, SPN, 2 way without bus bar, single door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, IP-54 rating, TPN, 4 way with 200 Amps rated bus bar, double door, 415 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one Single Pole MCB 20 Amps, 10 kA, 'C' Curve complete all as specified and as directed.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB SPN 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB SPN 40 to 63 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB TPN 32 Amp, 415 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs MCB TPN 63 Amp, 415 V, 50 Hz, AC supply, 10kA, 'C' Curve, complete all as specified and as directed.
S&F in repairs RCCB Double Pole 25 Amp, 240 V, 50 Hz, AC type, 30 mA, complete all as specified and as directed.
S&F in repairs RCCB Double Pole 40 Amp, 240 V, 50 Hz, AC type, 30 mA, complete all as specified and as directed.
S&F in repairs RCCB Four Pole 63 Amp, 415 V, 50 Hz, AC type, 30 mA, complete all as specified and as directed.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
All as per serial item No. 39 here-in-before but for one 3 pin 5/6 Amp modular switch socket on same board with other switches.
All as per serial item No. 39 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
All as per serial item No. 39 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
All as per serial item No. 43 here-in-before but for one 3 pin 5/6 Amp modular switch socket on same board with other switches.
All as per serial item No. 43 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
All as per serial item No. 43 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
Taking down carefully existing serviceable copper/ aluminium point wiring (light, fan, socket or power) complete, fittings such as switches, ceiling roses, pendants, regulators, socket etc and re-fixing the all item on same or different location including necessary electrical connection and testing after completion, complete all as specified and as directed. Note : Where replacement of any unserviceable accessory is required at site, same shall be measured and paid for separately under relevant item of this Schedule.
Taking down carefully existing serviceable DB/ Meter of any capacity & any type and re-fixing the same after repair work including necessary electrical connection and testing after completion, complete all as specified and as directed. Note : Where replacement of any unserviceable accessory is required at site, same shall be measured and paid for separately under relevant item of this Schedule.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories or heavy duty non-metallic rigid PVC conduit (ISI marked) & conduit fittings/accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Note :- 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories or heavy duty non-metallic rigid PVC conduit (ISI marked) & conduit fittings/accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Note :- 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.
M&L for sub main wiring with 04 runs of 6 sqmm (nominal area) size main cable & 02 runs of 6 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories or heavy duty non-metallic rigid PVC conduit (ISI marked) & conduit fittings/accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Note :- 04 runs of 6 sqmm size main cable, 02 runs of 6 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.
S&F in repairs heavy duty PVC casing and capping, minimum 25 mm wide, double lock type (ISI marked) with accessories for existing wiring of light point, fan point, bell point, PVC boards, with & including necessary screws, bolts, nuts, drilling etc. and making good disturbed surfaces complete all as directed.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
S&F in repair 4mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long fix to aluminium strip, nut, bolts and washers including taking down existing air termination complete all as specified & as directed.
S&F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws, enclosed in suitable PVC box, complete all as specified & as directed.
S&F in repairs PVC square block of size 100 X 100mm and 50mm deep with & including laminated sheet top cover fixed with cadmium plated screws for mounting switches, sockets, fan regulator etc. complete all as directed.
S&F in repairs PVC rectangular block of size 175 X 100mm and 50mm deep with & including laminated sheet top cover fixed with cadmium plated screws for mounting switches, sockets, fan regulator etc. complete all as directed.
S&F in repairs PVC rectangular block of size 200 X 150mm and 50mm deep with & including laminated sheet top cover fixed with cadmium plated screws for mounting switches, sockets, fan regulator etc. complete all as directed.
S&F in repairs PVC square box of size not less than 70 X 70mm fixed with suitable size screws to wall/ceiling etc to fix batten type light fittings over it complete all as directed.
S&F in repairs electronic driver suitable for LED security light fittings of 25 to 45 Watt 240V AC rating complete all as directed. Make: Philips/ Osram/ Jaquar/ C&S/ Bajaj/ GE / existing make as approved by GE.
S&F in repairs electronic driver suitable for LED 2x2 ft Panel light fitting of 36/ 40W 240V AC rating complete all as directed. Make: Philips/ Osram/ Jaquar/ C&S/ Bajaj/ GE / existing make as approved by GE.
S&F in repairs electronic driver suitable for LED 1x4 ft Panel light fitting of 42/ 45 W 240V AC rating complete all as directed. Make: Philips/ Osram/ Jaquar/ C&S/ Bajaj/ GE / existing make as approved by GE.
S&F in repairs suitable size PVC/ Fiber electric meter box with viewing window/ glass for meter reading for equiped existing electric meter single phase including all required mounting arrangement on wall/ panel complete all as directed by Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_854003.xls
BOQ • 0.28 MB
8955TENDER.pdf
Tender Documents • 0.92 MB
Download all tender documents and submit your bid