Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹1.6 Cr | L1 | Accepted-AOC Being L1 and reasonable. |
| 2 | L2₹1.6 Cr+₹3.9 L (2.41%)Rejected-Finance 796 AZAD NAGAR ROORKEE DISTT HARIDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | ₹1.6 Cr+₹3.9 L (2.41%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹1.7 Cr+₹5.2 L (3.21%)Rejected-Finance 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | ₹1.7 Cr+₹5.2 L (3.21%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹1.7 Cr+₹7.9 L (4.91%)Rejected-Finance | ₹1.7 Cr+₹7.9 L (4.91%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹1.7 Cr+₹12.9 L (8.01%)Rejected-Finance | ₹1.7 Cr+₹12.9 L (8.01%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
19 Mar 2021, 6:00 pmClosed
Chief Engineer Bareilly Zone
HQ Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
ADDN/ALTN CUM SPECIAL REPAIRS OF OTM ACCN AT DEHRADUN
2021_MES_420197_1
CEBZ/DDN/T-19 OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
DEHRADUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (P) DEHRADUN
₹2.9 L
Yes
15 Apr 2021
9 Feb 2021
24 Mar 2021
9 Feb 2021
19 Mar 2021
6 Mar 2021
10 Feb 2021 - 1 Mar 2021
Amount
SCHEDULE 'A' PART- I (B/R WORK )
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.. complete all as specified and directed.
Dismantling ceiling boards of any thickness and type from aluminium or GI frame work and refixing the same after repair work complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings. complete all as specified and directed.
Dismantling wall and ceiling boards, fibre or pulp, insulation etc. in insulation boards slabs, blankets any thickness incl cover fillets. complete all as specified and directed.
Dismantling timber scantling 40 sqcm & over in section framed work any position complete all as specified and directed.
All as per item No 6 above but as in fillets, rails, posts, rafters, purlins, etc. unframed work under 40 sq. cm in section complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
M&L second class hardwood (Sal) in scantling, timber clean sawn, timber fixed in, complete all as specified and directed.
M&L for preparation surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote. complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. Note : - Profile of ridge should match with profile of sheet.
Supply & fixing false ceiling of Designer ceiling tiles Ivory painted ready to use (made of high-Pressure Steem Cured 4 mm thick as per IS -14862 ) of size 595x595mm and any one of the design (Cascade or electra texture of Everest or equivalent) in true horizontal level, suspended on exposed inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at centre of size 4mm depth and 4.5mm width, all complete at all heights as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thick (below or above ground level) complete all as specified and directed.
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. laid dry or laid dry and pointed, complete all as specified and directed. (Note- each layer to be measured)
M&L for 25 mm thick PCC 1:2:4, type B-0 (12.5 mm graded stone aggregate) as in floors to receive floor finishes complete all as specified and directed.
M&L pre-polished machine cut kota stone slab flooring 20-25 mm thick over and including 20 mm thick cement screed base in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete (mirror polish) complete all as specified and directed
All as per item No 17 but on vertical faces of walls as in skirting and dados including 10 mm thick backing coat in CM 1:4 complete all as specified and directed
M&L for 50 mm thick PCC 1:2:4, type B-1 (using 20 mm graded aggregate) as in floors finished even and smooth without using extra cement complete all as specified and directed
Supply only glass dividing strips, 3 mm thick 48 mm width inserted in position to confirm to design complete all as specified and directed.
M&L for hard core of gauge n.exc 63mm deposited spread & levelled in layers n.exc 15cm thick watered and rammed to true surface with broken stones or boulders complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C-1, (20 mm graded stone aggregate)as plinth protection finishing even and smooth without using extra cement including making joints & filled with mix of bitumen and sand in ratio 1:3 between panels and corners, complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for joint free coloured ceramic tiles 7 to 8mm thick 400 x 400mm in size, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified including 15 mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed
All as per item No 25 above but as in skirting including 10mm thick rendering /screed in cement mortar 1:4 backing coat of tiles complete all as specified and directed
M&L for joint free coloured ceramic tiles 7 to 8mm thick 600 x 600mm in size, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified including 15 mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed
All as per item No 27 above but as in skirting including 10mm thick rendering /screed in cement mortar 1:4 backing coat of tiles complete all as specified and directed
M&L for joint free glazed ceramic coloured tiles of size 450 x300 x 7 mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile on vertical surfaces of wall including 10 mm thick rendering on brick surfaces in cement mortar 1:4 complete all as specified & directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 (40mm graded stone aggregate) as in sub bases for flooring etc., complete all as specified & directed.
M&L for Chequered cement concrete tiles glossy finish of size 300 x 300 x 25 mm thick machine pressed, set with neat cement slurry over 20 mm thick screed bed in cement mortar 1:4 and jointed and pointed with grey cement with pigment to match tiles complete all as specified & directed.
M&L for brick work with sub class 'B' burnt clay bricks built in CM 1:6 straight or curved on plan & exc 6 m mean radius with old size bricks complete all as specified & directed
All as per item No 32 above but except bricks complete all as specified & directed. (Note- Old bricks obtained from demolition shall be reused)
M&L for brick work with sub class 'B' bricks, in half brick thick wall built in CM 1:4 straight or curved on plan to any radius with old size bricks complete all as specified & directed
Taking down cement or cement lime plaster/tile work on brick or stone wall etc. including racking out joints, hacking for key and scrubbing down with water etc. complete all as specified and directed.
Complete removal of existing treatment etc from walls complete all as specified & directed
M&L for raking out joints/ pointing to brick work in wall etc built in cement mortar complete all as specified & directed
M&L for keyed pointing to brick walls in cement mortar 1:4 complete all as specified & directed
M&L for 15mm thick rendering on other than fair faces of brick/ concrete surfaces in cement mortar 1:6 finished surfaces even and fair complete all as specified & directed.
M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified & directed
M&L for applying two or more coats of Cement based Wall Care Putty on old/new plastered surfaces of walls ,including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over a coat of primer complete all as specified & directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of Ist quality exterior emulsion weather coat paint over a coat of alkali resistant priming paint complete all as specified & directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed
Excavation in post holes (or similar holes) n.exc 0.5 Sqm on plan and getting out and removing surplus soil to a distance not exceeding 50m and making good surface all as specified. (soft/ loose soil) complete all as specified and as directed
M&L for cement concrete 1:2:4 type B-2 (40mm graded crushed stone agg) as in foundation, filling and mass concrete complete all as specified and as directed
S&F steel work in tubular trusses including special shaped washer, plates, and tubular purlins etc. complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and as directed
M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) including forming forming holes, confirming to Fe-410-W(GdeE-250) quality complete all as specified and as directed
M&L bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 15 cm but n exc 22.5 cm long and dia of neck 16 to 20 mm complete all as specified and as directed
S&F tie bars with screwed ends, nuts, washers and mild steel plates for walls and straining bolts confirming to Fe-290Gde-E-165 complete all as specified and as directed
S& F in repairs 4 mm dia plain mild steel wire, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc. complete all as specified and as directed
M&L for cement concrete 1:2:4, type B1 as in copings , benching, bedplates etc. including all necessary formwork etc. complete all as specified & directed.
M&L for RCC 1:2:4, type B1 (Nominal Mix) as in shelves etc. including all necessary formwork etc. complete all as specified & directed.
S&F TMT bars 10mm dia and over cut to length bent to shape required incl. cranking bending spirally for hooking and binding with and incl. MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
M&L preparing new steel or iron surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed
Taking down chowkats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm and n exc 4.0 sqm each including taking out of holdfast & making good in CM (1:4) complete all as specified & directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frame) n.exc 1.5 Sqm each including taking out of holdfast & making good in Cement Mortar 1:4, complete all as specified & directed.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125 x 60 mm and thickness of sheet 1.25mm, complete all as specified & directed.
M&L for cement concrete 1:3:6, type C-0 (using 12.5 mm graded stone aggregate) as in bed plates, filling in pressed steel door frames etc. complete all as specified & directed.
M&L second class hardwood (Sal) Plain fillets. square, rectangular or triangular in section, sectional area exc 13 but n exc 25 Sqcm, wrought, fixed with screws complete all as specified and as directed
S&F 40 mm thick factory made flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and as directed
S&F for factory made Second class hard wood, 35mm thick glazed, and skeleton shutters open rebated & prepared to receive, glass, gauge etc. (without sash bars), edge of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkhats complete all as specified and as directed
S&F for factory made Second class hard wood, glazed and skeleton shutters for window/Ventilator , 30mm thick, open rebated and prepared to receive glass, gauze, etc.(without sash bars), and fitted with cut and mitred beads for securing glass, etc.; provided with stiles and rails as specified in SSR Part I, Section 8. clause 8.24 (b); and fitted to chowkats complete all as specified and as directed
All as per item No 64 above but divided in to square with plain, chamfered or rounded, mitred and rebated sash bars any numbers complete all as specified and as directed
S&F Ist class hard wood (shesam) small fittings such as brackets of any type, door stoppers and like including all necessary labours, articles n exc 200 cucm each complete all as specified and as directed
S&F Gate and shutter, hooks and eyes 150 mm of mild steel wire type -I complete all as specified and as directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete, brick surrounds, glazed with putty or fixed with beads , complete all as specified.
Material and labour for 4mm sheet glass, ordinary quality and glazing with oil putty / pins /spring pins and wooden beads in square not exceeding 0.5 Sqm in each pane complete all as specified.
Supply and fixing mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and as directed
Supply only butt hinges size 100 mm, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F butt hinges medium weight cold rolled mild steel, size 75 mm omplete all as specified and as directed
Supply butt hinges size 50 mm, medium weight, cold rolled mild steel complete all as specified and as directed
S&F aluminium handles fabricated type anodised 150 mm size complete all as specified and as directed
S&F aluminium handles fabricated type anodised 100 mm size, complete all as specified and as directed
S&F aluminium anodised barrel tower bolt of extruded section 200 mm length of bolt complete all as specified and as directed
S&F in repairs aluminium anodised barrel tower bolt of extruded section 200 mm length of bolt complete all as specified and as directed
S&F 100 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed
S&F in repairs 100 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed
S&F Stainless steel sliding door bolts, bolt and clip type with bolt of 16mm dia with and including a minimum of 6 bolts and nuts, and fixed complete all as specified and as directed
S&F Stainless steel sliding door bolts, bolt and clip type with bolt of 16mm dia with and including a minimum of 6 bolts and nuts, and fixed in repairs complete all as specified and as directed
S&F floor door stopper of aluminium body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 140 mm and fixed to door shutters complete all as specified and as directed
Resecuring or easing & adjusting without taking down shutters of any description not exc 1 Sqm each complete all as specified and as directed
Resecuring or easing & adjusting without taking down shutters of any description exc 1 and not exc 2 Sqm each complete all as specified and as directed
M&L for preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed
All as per item No 85 above but except primer.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F 20 mm dia stainless steel curtain rod thickness 1.00mm including fancy type brackets fixed to wall and 8 Nos curtain rings per RM (minimum) complete all as specified & directed.
S&F 18 mm thick plywood coated with fibre reinforced plastic (FRP) 3mm laminated on both faces (3mm +12mm+3mm) and edges to be sealed with PVC edges binding tape for foldable writing table complete as per specifications and as directed.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanized, width of flap 30 mm complete all as specified and as directed
M&L for 18 to 20 mm thick Granite (of any type) work in jambs, pillars, cooking platform and like in cm 1:4 and pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed
Rounding to edge of granite stone slab one edge, such as in steps, cooking platform, and other similar situation complete all as specified and as directed
S&F vitreous china wash hand basin table top type fixed on counter including CP waste coupling & waste pipe complete all as specified and directed
S&F 15mm size PVC connection with PTMT nuts length 450mm long complete all as specified and as directed
M&L tube medium grade with fittings and fixed complete to walls and ceiling or laid in floors, bore of pipe 15mm complete all as specified and as directed
S&F stop valves 15mm bore fancy type chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed
S&F 15mm bore brass CP mixture for wash basin with hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed
M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed
M&L for Post construction anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed
SCHEDULE 'A' PART-II (E/M SERVICES)
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, lamp holder, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for point wiring (concealed) complete using approved colour coding as per IS (Red, Black, Green for single phase circuit) with multi-stranded copper conductor 1.5 Sqmm nominal cross section area, single core PVC insulated unsheathed FRLS-H cable 1100 volts grade, IS-694 marked with valid CM/L No. in and including PVC conduit medium grade conduit accessories such as bend, tee, junction boxes elbows etc, ISI marked with valid CM/L No. (IS :9537 -1983 for conduit and IS :9537 -1976 for conduit accessories) including pressed steel terminal sunken boxes 1.6 mm thickness, 65mm deep with earth dolly, duly painted with two coats of black bitumenous paint over a coat of red oxide primer externally, covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with brass screws, cup washers and PVC unsheathed copper conductor 1.5 Sqmm cross sectional area, single core FRLS-H cable as earth continuity wire connected to DBs/sunken boxes/fittings conductor and all other metal parts with earth dolly, including cutting chasses and making good the surfaces in cement mortar 1:3, complete all as specified and directed for the following:- (Note:- Under this item points shall be made against old taking down points under item No.102)
One light point / bell buzzer point controlled by 01 no. one way switch.
One ceiling fan / exhaust fan point controlled by 01 no. one way switch through regulator.
One 3 pin 5 amps socket outlet point on independent board.
One 3 pin 5 amps socket outlet point on same board.
M&L for new point wiring (concealed) complete using approved colour coding as per IS (Red, Black, Green for single phase circuit) with multi-stranded copper conductor 1.5 Sqmm nominal cross section area, single core PVC insulated unsheathed FRLS-H cable 1100 volts grade, IS-694 marked with valid CM/L No. in and including PVC conduit medium grade conduit accessories such as bend, tee, junction boxes elbows etc, ISI marked with valid CM/L No. (IS :9537 -1983 for conduit and IS :9537 -1976 for conduit accessories) including pressed steel terminal sunken boxes 1.6 mm thickness, 65mm deep with earth dolly, duly painted with two coats of black bitumenous paint over a coat of red oxide primer externally, covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with brass screws, cup washers and PVC unsheathed copper conductor 1.5 Sqmm cross sectional area, single core FRLS-H cable as earth continuity wire connected to DBs/sunken boxes/fittings conductor and all other metal parts with earth dolly, including cutting chasses and making good the surfaces in cement mortar 1:3, complete all as specified and directed for the following:- (Note:- Under this item points shall be made against old taking down points under item No.102)
one light point / bell buzzer point controlled by 01 no. one way switch.
One ceiling fan / exhaust fan point controlled by 01 no. one way switch through regulator.
One 3 pin 5 amps socket on same board with other switches.
One 3 pin 5 amps socket on independent board.
All as per item No 103 above, but one 3 pin socket outlet 15 Amp on independent board with cable 2.5 Sqmm size, with earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
All as per item No 108 above, but one 3 pin socket outlet 15 Amp on independent board with cable 2.5 Sqmm size, with earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
S&F switch piano, flush button type, 5 Amp SP 240 V AC complete all as specified and directed.
S&F switch piano, flush button type, 15 Amp SP 240 V AC complete all as specified and directed.
S&F socket outlet multipurpose, 3 pin 5 Amp and 2 pin 5 Amps 240 V AC complete all as specified and directed.
S&F socket outlet two in one, 3 pin, 5 Amp and 15 Amp 2 module 240 volts, flush type complete all as specified and directed.
S&F bell push button type, 5 Amps complete all as specified and directed.
S&F ding dong bell, AC 230 V, Single pole complete all as specified and directed.
S&F lamp holder PVC/polycarbonate type with back plate suitable for batten fittings, 240 V AC complete all as specified and directed.
S & F ceiling rose, 3 phase / PVC / polycarbonate, isolated body, 250 V AC complete all as specified and directed.
M&L in replacement sub main wiring with 2 single core PVC insulated unsheathed FRLS-H cable 1100 volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing in and including 20 mm dia or higher PVC conduit (Concealed), medium grade heavy duty with accessories and fittings and insulated unsheathed FRLS-H cable copper conductor multistranded of size 6 Sqmm as earth wire upto common earth and connected to earth including taking down old sub main wiring duly complete all as specified and directed.
S & F in replacement sheet metal enclosures 240 Volt with 200 Amp rated copper bus bar for double door 8 way IP-43 DBs IK-09 suitable for one MCB SPN as incoming and 6 MCB SP as outgoing mounting flush on wall and making good disturbed surfaces including taking down old DBs complete all as specified and directed. (MCB's shall be measured and paid separately)
S&F in replacement and testing TP&N vertical load line (VTPN) 4 way 415 Volts 50 Hz indoor type double door sheet metal enclosure IP-43 DBs IK-09 flush mounted with 250 Amp copper bus bar for each phase with two neutral bar & two earthbar and cable lies for cable management including provision of MCCB 63 Amps ICs= 100% ICu, 16 KA four pole as incomer including connecting terminal strip complete and SP MCBs as outgoing complete pre-wired with suitable size copper conductor including taking out old unservicable DB and removing from site and making good of disturbed surface complete all as speciifed and directed. Note:-(i) MCCB / MCBs shall be measured and paid seperately. (ii) VTPN DB/MCCBs/MCBs will be of same make)
S&F MCB, double pole, 240 Volt, 10 KA, 40 Amp, 'B' series confirming to ISI marked complete all as specified and directed.
S&F MCB, single pole, 240 Volt, 10 KA, 6 to 32 Amps, 'B' series confirming to ISI marked complete all as specified and directed.
S&F MCCB, 415 Volt, 16 KA, 4 pole, 63 Amp, magnetic trip release and setting as incoming with fixing arrangement complete all as specified and directed.
S&F in replacement wall mounted LED tube light fitting 1 x 20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140 V - 270 V color temp 6500K & lumen input output 95 lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall / roof including taking down old tube light fitting complete all as specified and directed. Make :- Philips cat part No TMC 1001XT LED 13-20 WWH (Tube Batten) and MAS LED 1200mm 18W-865 T-81 (tube) / Wipro Cat Part No WI0921208 (Tube Batten) LL13-181-650(Tube)/Havells Cat Part No. CP REGAL BATTEN 8 UPTO 1X20WSSBSWH (Tube Batten), PHOTON ULTRA E201213T11W LED865SPC.
S&F LED light 1 x 10 Watt bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as speciifed and directed. Make :- PHILIPS CP No.WT140WLED75CW/PSUSIPC /Havells CP No.HEXAFT10WLED857SSYMBOPC/WIPRO CP No.LW07-141-XXY-57XX
S&F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS and CFL direct fit in holder complete all as specified and directed. Make:-PHILIPS model-Stellar Bright High wattage 15000 life Hrs/ Havells CP No.LHEAABPTIL 1W012/C&S CP No.CRONA-RNO 118W
Supply & fix ceiling Fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan and writing MES NO on fan complete all as specified and directed .
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed
M&L earthing complete with using galvanised mild steel earth plate (electrode) 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr depth below ground level with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15cm all round the plates using 4mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch / control board at another end. GI earth lead protected in and including 15mm dia GI medium grade pipe from upper end of earth plate upto equipment with & including 20mm dia bore GI pipe medium grade as water pipe from earth chamber to upper edge of the earth plate. GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B1 (using 20mm graded stone aggreagte) as in pit chamber, 50mm thick pre-cast RCC cover reinforced with 8mm TMT bars @100mm C/C both ways and lifting handles of 10mm dia mild steel round bars etc complete as per electrical plate No-03 of SSR (Part-II): 2010 and testing on completion all as specified and directed. Note:- (i) If the desired earth resistance is not found within permissible limit, item shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 Sqmm and 15mm dia pipe medium grade upto 7.5m is deemed to be included in the rate quoted for this item.
S&F new air ventilation fan, metallic body, 300mm, 900 RPM with louvers, single phase, 230V AC including necessary fittings and M&L for making hole on wall and fixing arrangement with frame holdfastener, bolts, washers etc. including connection with 3 core flexible copper conductor multistranded cable from ceiling rose to connector complete all as specified and directed.
S&F in replacement integral LED street light luminaire comprising of pressure die cast aluminium housing heat resitant toughened glass with frame IP-65 protection road way luminairies with high power LED 45 Watt with efficiency 100 lumen/watt at system level, CCT>5700K with average life class 50,000.00 burning hours including GI brackets made out of 25mm GI pipe medium grade and MS clamps for fixing of light fittings and connected with twin core PVC insulated copper flexible cable with existing point including taking out old unservicable street light complete all as specified and directed. Make:- PHILIPS model No. BRP056LED53CWSLFPSU51 (45W5300 LUMENS STREET LIGHT)/ HAVELLS MODEL No.ENDURAPEARLNEOS145WLED757PASYTOPC/ C&S Model No.LTESS145WLED/LS
Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cables ( heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core, in repairs complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated,screened,PVC bedded,galvanised steel strip or wire armoured electric power cables ( heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core, in repairs complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 316595.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/S AJIT CONSTRUCTION CO
Alankar Traders
RAMAPATI ENGINEERING SERVICES
M/s BK Enterprices
Ms Banco Builders
M/s S.D Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .