Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC Lowest bidder | |
| 2 | l2₹20.8 L+₹1.2 L (6.03%)Rejected-Finance | l2 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹23.3 L
EMD Value
₹46,640
Closing Date
5 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
SPL REPAIRS TO HT OVERHEAD LINES AT SPECIFIC LOCATION UNDER GE(N) TEZPUR
2023_MES_611455_1
CWE/TEZ(N)/T-20 of 23-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (N) Tezpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(N) Tezpur
₹46,640
Yes
16 Oct 2023
1 Aug 2023
7 Sept 2023
1 Aug 2023
5 Sept 2023
22 Aug 2023
Amount
Dismantling Insulators like Pin type, disc type for HT from existing HT Electric Poles of any description and any size, complete all as specified and as directed.
Dismantling and taking down existing unserviceable Gang operated switch complete including dropout fuse set from RCC / Steel tubular (Single / 2Pole / 3Pole / 4 Pole) pole structures complete all as specified and directed.
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc of any size, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed.
Dismantling ACSR with steel wire or Conductors of any size and any span complete all as specified and as directed.
Dismantling Earth Wire, Cradle Guarding, etc., complete all as specified and as directed.
Dismantling the existing external electricfication system 11KV consisting of RCC pole structures (Single / 2Pole) complete all as specified and directed.
Dismantling the existing external electricfication system 11KV consisting of Steel tubular Poles structures (Single/2Pole) complete all as specified and directed.
Supply laying, jointing and testing HT cable XLPE insulated,screened, PVC bedded , galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor conforming to IS:7098 (Part 11), 11 KV earthed grade, cross sectional area 95 sq mm 3 core under trenches/pole etc complete all as specified and directed. NOTE : Earthwork will be measured and paid under appropriate Items.
M&L Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and as directed
M&L Cable End Jointing Kit indoor Termination Cold Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and as directed
M & L for Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted having 12 insulator and fitted on steel frame suitabe for, current rating 200 Amps, mechanically operated mechanism consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including Expulsion Fuse, Single Pole, Channel type/ drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps , complete all as specified and as directed.
Excavation in trenches, in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out of soft / loose soil complete all as specified and directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. Only punned thickness to be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover class HV, type - I, flat, size 300 x 180 x 40 mm all as specified and directed.
Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 100 mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
Supply & fixing GI Pipe light grade 80 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc to be fixed to poles/in trenches complete all as specified and directed.
Supply, install, testing & commissioning of HT busbar chamber CPRI approved of size (0.90x0.90x0.75)m , outdoor type, 7 tank processed factory fabircated CRCA sheet powder coated of 3.15 mm thickness, indoor plates 2mm thick, angle iron of size 50X50X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete comprising of following :- BUS-BAR AND CABLE ENTRY (a)The bus-bars shall be made up of 03 Nos Aluminium 200 A rated not less than 32mmx6 mm, (b)The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going HT cables of size not less than 95 Sqmm x 3 core). Notes:- (i) Danger notice plate of size 25 x 20 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for HT conforming to IS-2551 - 02 Nos. (ii) Design / Drawing / BOM of the HT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. (iii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Materials and Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel strip 32 mm x 6mm by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete as specified and directed. Note: (i) The cost of GI strip of size 32 x 6 mm from top of earth plate up to 7.5 metre above ground level is deemed to be included in the unit rate of above item. (ii) All the joints in GI strip and connection with Earth Plate to be welded and in addition by providing double brass nut bolt and washer. (iii) Cost of welding and nut bolts are deemed to be included in the unit rate.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, for soft loose soil complete all as specified and directed.
Cement concrete 1:3:6 type D2 (using 40 mm graded aggregate) as in foundation filling and mass concerete
Mild Steel angle posts and struts in fencing including cutting tops to shape, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe 290 ( Gde E-165) complete all as specified and directed.
S&F Mild steel screw bolts dia of neck 11 to 15mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and n exc 15cm long complete all as specified and directed.
Supply only Chain Link MS galvanized fencing of mesh size 150mm X 100mm X 3.15 mm dia complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type of standard , rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Preparation of New or previously untreated steel and iron Surfaces of any description, Two coat of Synthetic enamel paint over one coat of Red oxide over 10cm in width or girth,not otherwise described
Preparation of New or previously untreated steel and iron Surfaces of any description, Two coat of BlacK Japan paint over one coat of Red oxide over 10cm in width or girth,not otherwise described
S & F cable route markers made out of PCC (1:3:6) type C1 using 20mm graded stone aggregate size 900 x 300 x 100 mm thick (60 cm buried in ground with "DANGER/11 KV UG CABLE" embossed on marker including excavation and earth work complete all as directed.
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .