| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2ND FLOOR PAPPOOTTY COMPLEX VAZHAKULAM MUVATTUPUZHA KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | Admitted-Finance |
| 2 | Admitted-Finance 58 667 SAPTHATHI BUILDING KONTHURUTHY THEVARA ERNAKULAM KERALA 682013 | ERNAKULAM | KERALA | 682013 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹65,000
Closing Date
30 Jan 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGM(Mat)-C
Corporate Materials, PD Administration Building, FACT-Udyogamandal, Kochi, Kerala
Electrification of Quarter Nos. 1 to 42 of B1 Flat in FACT Township Udyogamandal, 2023-24, as per tender documents.
2024_FACT_789419_1
03017/2023-2024/E28775
Open Tender
Electrical Works
Item Rate
240 days
FACT Udyogamandal, Kochi
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹65,000
Yes
20 Apr 2024
9 Jan 2024
31 Jan 2024
9 Jan 2024
30 Jan 2024
9 Jan 2024
Amount
Erection, Termination and connection of the 4 way/6 way, 3ph ,415 V Horizontal/Vertical double door MCB Lighting DB Having 63 A , 4 pole Isolator as incomer and 6 no of 2 pole isolators of rating 40 A for each Quarters and 10 A MCBs for Providing Supply for Stair case and car shed of each quarters. DB shall be mounted either in a concealed way or in suitable frame fabricated by suitable MS angle frame (50 x 50 x 6),epoxy painted(primer + 2 coats) and properly fixed on wall by the contractor , The incomer PVC armoured cable (up to 4 * 50 Sq.mm) outgoing flexible copper cables of 4 Sq.mm, earth cables of size 2.5 Sq.mm for power circuit through 40 A DP to each quarters and out going for staircase and Car shed shall be glanded /terminated and connected using suitable cable lugs /clamps /ties . All Required structural items, DB with DP/MCB s, flexible glands ,suitable PVC Conduits etc, shall be in the scope of the contractor. Existing in-put armoured cable can be used for main supply from Pillar Box . If incomer cable length is not adequate for termination in DB, Cable should be jointed with copper/aluminium flexible cable of size similar to incomer cable by proper lug/ferrules by providing suitable joint box near DB , This also be in the scope of the contractor.All the MCBs,Isolators,RCCBs used in DB should be of Same Brand as of DB Used for this Work. APPROVED MAKE : 1) DB, RCCBs & MCBs : Legrand/Havells/Schneider/L&T
Erection, Termination and connection of the 16/18 way, single phase ,230 v Horizontal/ Vertical MCB lighting DB having 40A,30 mA RCCB, 40A DP isolators as incomers SP MCBs -10 A-8no (in case 16 way) /10 no in case of 18 way and SP MCBs 16 A -4 no(1 spare), single phase out going circuits, LDB shall be mounted properly on the wall by the contractor . Incomer for this DB should Drawn through Conduits Size not less than 20mm from Main DB Fixed in the ground floor by suitable metal saddles spacing not less than 50 cm , 4 sq.mm Phase and Neutral Wire and 2.5 Sq.mm for Earth. All Required items for this Work Shall Be in the scope of the Contractor (Including the cementing and finishing of the wall after fixing of the DB)All the MCBs,Isolators,RCCBs used in DB should be of Same Brand as of DB Used for this Work. APPROVED MAKE : 1) DB, RCCBs & MCBs : Legrand/Havells/Schneider/L&T
Supply of 6A Modular Switches as spares for the work specified in Schedule No -3 (Brand and type of switches should be exactly same as the switches used for the work specified in Schedule No -3)
Supply of 6A Modular Sockets as spares for the work specified in Schedule No- 3 (Brand and type of sockets should be exactly same as the sockets used for the work specified in Schedule No -3)
Supply of Modular step type regulators as spares for the work specified in Schedule No - 3 (Brand and type of Regulators should be exactly same as the Regulators used for the work specified in Schedule No -3)
Open Conduits Point wiring with individual control For 16 A power sockets switches, using Flexible copper cables 2.5 Sq.mm for control and neutral connection Through PVC conduits not less than 20 mm using metal saddles with spacing not exceed 50 cm as per relevant drawings or instructions from FACT Engineer in Charge . The work shall include wiring along roof /beam/column/ceiling using clamps and drawing wires as required Preparation and fixing of modular switch boards, switches, cover plates, dummy plates, Etc. Drawing of 1.5 Sq.mm earth wires of flexible copper wire of green colour for body earthing of metal clad items ,connecting, etc, All the materials for this Work shall be in the Scope of the contractor. For wire length greater than 10 m shall be considered as one and half point. If additional power sockets are provided in same Switch Boards that shall be considered as half point. Colour code for Phase Wire :- Red/Blue/Yellow Neutral :-Black Earth :-Green APPROVED MAKE : 1) WIRE : FR wire of POLYCAB/ RR KABEL/ HAVELLS 2) SWITCH & SOCKETS : LEGRAND- MYRIUS / HAVELS- CORAL/SCHNEIDER-UNICA PURE/ L&T-ENTICE
Supply of 16A Modular Switches as spares for the work specified in Schedule No -7 (Brand and type of switches should be exactly same as the switches used for the work specified in Schedule No -7)
Supply of 16A Modular Sockets as spares for The work specified in Schedule No -7 (Brand and type of sockets should be exactly same as the the sockets used for the work specified in Schedule No -7)
Supply and Installation of 20 W LED tube fittings/bells with required clamps/fasteners. Supply of all materials required for the work such as LED Fittings, Bells, clamps and fasteners etc. are under the scope of the contractor. APPROVED MAKE :- LUKER/HAVELLS/PHILIPS
Supply of LED tube Fittings as spares for the work specified in Schedule No-10 (Brand and type of LEDs should be exactly same as the the LED fittings used for the work specified in Schedule No -10)
Supply and installation of ceiling fans (1200 mm) . Supply of all materials required for the work shall be under the scope of the contractor. The specification of Ceiling Fan is such that its Service Value should be higher Than 5.5 CMM/Watts. (Refer BEE Guide lines for Service Value and Star Ratings ) APPROVED MAKE FOR FAN :- LUKER/CROMPTON/ USHA/ HAVELLS
Supply and installation of Angle Batten Holders for Rooms , Bathrooms, Stores and Work area. All material required for the work including the Angle Batten Shall be supplied by the Contractor.
Erection of earth electrodes ,earth cable laying 2 runs of 1 x 16 Sq.mm Aluminium PVC cable, from earthing pit to corresponding 3 phase DB, clamping ,connection and commissioning of maintenance free copper bonded earthling systems of DB -at suitable locations . Installation of earthing system as per the specified condition mentioned above and supply of All required materials for this work such as maintenance free copper bonded earthing system approved by Kerala State Electrical Inspectorate , compressing of 3 m long, dia not less than 17 mm earth electrode of low carbon steel with 250 micron copper bonding on outer surface with associated items like environment friendly carbon based back fill compound hardware, clamps, binding wires, connection lugs, anticorrosive paint, bitumen , Sand ,cement, Bricks and required length of 1 x 16 Sq.mm flexible Al PVC cable etc as required for this work shall be in the scope of the contractor.
Rerouting of Power Cables up to 4*50 Sq.mm from Existing 3 phase DB to New DB Location as specified by FACT Engineer -in - Charge
Excavation of new cable trench of size 300 mm * 300 mm [width x depth] in ordinary soils for laying cables. The scope of work also includes refilling and consolidating the trench after completion of the cable laying work.
Linsta Services
PEEJESS ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .