| 1 | L1₹10.2 LAccepted-AOC 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹10.2 L Quoted ₹10.5 L | L1 | Accepted-AOC THE LOWEST BIDDER |
| 2 | L2₹13.8 L+₹3.3 L (31.8%)Rejected-Finance 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | ₹13.8 L+₹3.3 L (31.8%) | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹14.7 L+₹4.2 L (40.4%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹14.7 L+₹4.2 L (40.4%) | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹15.4 L+₹5.0 L (47.3%)Rejected-Finance | ₹15.4 L+₹5.0 L (47.3%) | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| 5 | L5₹16.2 L+₹5.7 L (54.8%)Rejected-Finance | ₹16.2 L+₹5.7 L (54.8%) | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | MVV Prasad L1 | DHEERU BUILDERS L4 | SRI SRK ENGINEERS L3 | SRI LAKSHMI GANAPATHI CONSTRUCTIONS L6 | SVG SUPPLIES L2 | VEEKSHITH ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in 11 KV HT cable by giving high voltage surge and to find out exact location of fault complete all as specified and directed .
(Note : The Item includes transportation, charging machine upto detecting fault at a time). | 4 | Each Job | 10,000 ₹40,000 | 40,000 ₹1,60,000 | 37,500 ₹1,50,000 | 40,000 ₹1,60,000 | 5,500 ₹22,000 Lowest | 9,500 ₹38,000 |
| 2.00 | Supply, laying and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 240 sq. mm, 3 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed.
(Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item) | 20 | RM | 1,575 ₹31,500 Lowest | 1,900 ₹38,000 | 1,850 ₹37,000 | 1,899 ₹37,980 | 1,680 ₹33,600 | 3,500 ₹70,000 |
| 3.00 | All as per item No. 2.00 abive but of 185Sqmm 3 core. | 15 | RM | 1,325 ₹19,875 Lowest | 1,700 ₹25,500 | 1,620 ₹24,300 | 1,725 ₹25,875 | 1,389 ₹20,835 | 2,500 ₹37,500 |
| 4.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed. | 5.51 | Cum | 324.06 ₹1,785.57 | 400 ₹2,204 | 300 ₹1,653 | 389 ₹2,143.39 | 225 ₹1,239.75 Lowest | 700 ₹3,857 |
| 5.00 | Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. | 3.24 | Cum | 184 ₹595.47 | 140 ₹453.07 | 100 ₹323.62 Lowest | 256 ₹828.48 | 125 ₹404.53 | 500 ₹1,618.12 |
| 6.00 | Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed. | 2.27 | Cum | 124 ₹281.95 Lowest | 350 ₹795.82 | 200 ₹454.75 | 452 ₹1,027.74 | 150 ₹341.06 | 440 ₹1,000.45 |
| 7.00 | Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed.
Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment. | 1.98 | Cum | 1,000 ₹1,980 | 2,000 ₹3,960 | 1,200 ₹2,376 | 256 ₹506.88 Lowest | 950 ₹1,881 | 1,250 ₹2,475 |
| 8.00 | Supplying and laying, factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed. | 136 | Each | 80 ₹10,880 | 88 ₹11,968 | 80 ₹10,880 | 99 ₹13,464 | 22 ₹2,992 Lowest | 300 ₹40,800 |
| 9.00 | S & F Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination Outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 95 -120 sqmm fixed in repair, including testing after jointing complete all as specified and directed. | 2 | Each | 7,500 ₹15,000 | 11,600 ₹23,200 | 12,000 ₹24,000 | 1,200 ₹2,400 Lowest | 3,127 ₹6,254 | 7,800 ₹15,600 |
| 10.00 | Supply and Fix Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 185-240 sqmm fixed in repair, including testing after jointing complete all as specified and directed. | 2 | Each | 8,500 ₹17,000 | 13,900 ₹27,800 | 13,300 ₹26,600 | 13,800 ₹27,600 | 3,445 ₹6,890 Lowest | 7,500 ₹15,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
12 Jul 2025, 6:00 pmClosed
GE(I)(CG) VIZAG
GE (I) (CG) VIZAG Military Engineer Services, CGWO Building, C/o Fleet Mail Office, Visakhapatnam - 530 014
REPAIR / REPLACEMENT, MAINTENANCE OF 11 KV VCBS , RMU AND CABLES AT ICGS MALKAPURAM, ICGS JETTY VISAKHAPATNAM UNDER GE(I) CG VISAKHAPATNAM
2025_MES_716183_1
GE(I)CG/VIZ/TOKEN 37 OF 2025-26
Open Tender
Miscellaneous Works
Item Rate
270 days
VISAKHAPATNAM
DETAILS AS PER NIT OF THE TENDER
9 documents required · 9 mandatory
₹500
GE(I)(CG) VIZAG
₹30,000
Yes
29 Aug 2025
23 Jun 2025
14 Jul 2025
23 Jun 2025
12 Jul 2025
6 Jul 2025
Amount
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in 11 KV HT cable by giving high voltage surge and to find out exact location of fault complete all as specified and directed . (Note : The Item includes transportation, charging machine upto detecting fault at a time).
Supply, laying and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 240 sq. mm, 3 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed. (Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item)
All as per item No. 2.00 abive but of 185Sqmm 3 core.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
S & F Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination Outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 95 -120 sqmm fixed in repair, including testing after jointing complete all as specified and directed.
Supply and Fix Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 185-240 sqmm fixed in repair, including testing after jointing complete all as specified and directed.
S & F Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for straight through joint Kit Outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 185 - 240 sqmm fixed in repair, including testing after jointing complete all as specified and directed.
S & F Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for straight through joint Kit Outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 95- 120 sqmm fixed in repair, including testing after jointing complete all as specified and directed.
Repair, Maintenance & overhauling of HT (11 KV) VCB of capacity 400 Amps to 630 Amps, indoor type complete after taking out trolley, checking of all fixed and moving parts for smooth operations, cleaning with CTC or CRC 226 and rustlick, air blower, replacement of minor parts, checking and repair to locking system, alignment & closing / triping & charging system including replacement of FRP phase barier and provideing re-insulation to bus bar with HT tape, repair to heaters and making the complete VCB functional with free and operating mechanism, complete all as specified and directed NOTE: (i) Cost of transporation charges for the vehicle, T&P required is deemed to be included in the quoted rate. (ii) contractor will arrange his workmen along with T&P in a manner that nonfunctional HT line is made functional swiftly within 24 hour of receiving of complaint from the MES, during entire contract period.
Supply only of Vacuum bottle suitable for 630 Amp, 11 KV HT VCB, of existing make complete all as specified and directed.
Supply only of tripping coil suitable for 11 KV 400 Amps to 630 Amps HT VCB, complete all as specified and directed.
Supply only Auxiliary switch NO/NC suitable for 11KV HT VCB as per sample, complete all as specified and directed.
Supply only Shunt trip coil 24-30 Volts DC suitable for 11 KV VCB, complete all as specified and directed.
Repair, testing and calibration and making functioning existing IDMT over current and earth default relays of any type for HT VCB 11KV including assembling, complete all as specified and directed.
Supply and fixing in repair Epoxy casted 3 phase PT unit with fuse of HT VCB 11 KV/110V, 50 VA conforming to IS approved as in replacement, including connecting, testing & commissioning, complete all as specified and directed.
Supply and fixing in repair CT unit, 200/5Amps, 15VA burden, accuracy 8.5 as per IS 2705 for metering / protection of HT VCB 11KV, as in replacement, including connecting, testing & commissioning, complete all as specified and directed.
Supply and fixing in repair Volt meter 0-15KV with PT, digital type, suitable for HT VCB 11KV/110V, as in replacement, complete all as specfied and directed.
Supply and fixing in repair Ammeter, digital type, 200/5 Amps & 100/5 Amps, suitable for HT VCB 11KV, as in replacement, complete all as specified and directed.
Dismantling and removing of Compact Sub Station of capacity 1000 KVA and shifting from site to workshop for repair, opening in the presence of Engineer-in-Charge, taking out coil and detaching core & core assembly for estimation of repair and damaged parts, cleaning and removing the dust from all parts including cores, cooling tubes, removal of damaged parts, shifting to site and re-fixing in position after repairs, provision of cork sheets, making connections, including testing and commissioning, complete all as specified and directed. Note : Supply and fixing of new spare parts shall be measured and paid separately.
Supply and fixing in repair HT bushing insulator complete with brass stud washers & nuts etc, for transformers of capacity 1000KVA, complete all as required and directed.
Supply and fixing in repair LT bushing insulator complete with brass studs washer & nuts etc, for transformer of capacity 1000 KVA, complete all as required and directed.
Disconnecting, taking out and removing of RMU, 11KV, 630Amps, 50Hz, indoor type, 01 way VCB and 2 way LBS, with CT/PTs from site for repair, opening in the presence of Engineer-in-charge, checking of old fixed & moving parts, cleaning with CTC or CRC 226 & rustlick, air blower and removal of unserviceable parts of RMU, replacement of minor parts, adjustment of earth switches, checking & adjustment / repair to locking system, setting of alignment, closing & charging system, trip catch assembly and replacement of bushing of bus bar chamber etc and making functional, testing & commissioning, complete all as specified and directed. NOTE: (i) Cost of transporation charges for the vehicle, T&P required is deemed to be included in the quoted rate. (ii) contractor will arrange his workmen along with T&P in a manner that nonfunctional HT line is made functional swiftly within 24 hour of receiving of complaint from the MES, during entire contract period.
Supply only Cable Terminal Protector Boots, suitable for RMU 11KV 630Amps, approved existing make, complete all as specified and directed.
Supply only indicator LED type (R/Y/B), suitable for RMU 11KV 630Amps, complete all as specified and directed.
Supply only trip coil/close coil 24 Volts DC suitable for 11KV RMU , complete all as specified and directed.
Supply only 11KV bus coupling bush suitable for 11 KV ring main unit , complete all as specified and directed.
S&F in repair LED indication lamps, 110 V of various colours complete all as specified and directed.
Supply and fixing in repair Epoxy casted 1 phase PT unit with fuse of HT RMU 11 KV/110V, 50 VA conforming to IS approved as in replacement, including connecting, testing & commissioning, complete all as specified and directed.
Supply and fixing in repair RMU VCB Main Mechanism of HT RMU 11 KV in replacement, including testing & commissioning, complete all as specified and directed.
M&L for complete overhauling / repair of float cum boost charger, cleaning of all parts, checking all wiring , Checking Output Voltage, Checking entire DC Circuit from Charger to the panel Fuse including replacement of minor item required for repair complete all as specified and as directed .
M&L for power pack DC for auxiliary power supply to operate closing & tripping coils, protection relay circuits & other indication lamps for 11 KV HT VCB panel, make as per OEM suitable to operate the control circuit, input supply 110/230 Volts AC + 10% to - 30 %, 50 HZ to give an output supply of 110 V, DC with battery backup including taking down old one complete all as specified and as directed. Note :- Unit rates quoted against this item shall deemed to include cost of suitable stranded copper conductor cable from power pack to HT panel complete
SVG SUPPLIES (BID ID -3356149)
SRI SRK ENGINEERS (BID ID -3356468)
DHEERU BUILDERS (BID ID -3356620)
VEEKSHITH ENTERPRISES (BID ID -3356831)
SRI LAKSHMI GANAPATHI CONSTRUCTIONS (BID ID -3356539)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .