Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹4.5 LAccepted-AOC | l1 | Accepted-AOC LOWEST TENDER QUATED |
Tender Value
₹5.0 L
EMD Value
₹12,393
Closing Date
6 Nov 2024, 3:00 pmClosed
Assistant engineer
Assistant engineer Eloormunicipality
Annual Plan-Eloor Municipality-S0140/24- High Mast Lights on different places-Supply Installation Testing and Commissioning of Mini High Mast Lights in ward 27 near Manjummel Ayurvedha Dispensary and ward 13 Bosco Colony. -General Electrical Work
2024_LSGD_694608_2
140/ET/AE/LSGD/ELR/2024-25
Open Tender
Electrical Works
Item Rate
60 days
Eloor municipality
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,095
₹12,393
2 May 2025
30 Oct 2024
8 Nov 2024
30 Oct 2024
6 Nov 2024
30 Oct 2024
Amount
Supply and providing High Mast Light and Electrification
OD86509/2024-2025:Supply installation testing and commissioning of Mini High Mast using 8 /12 sided Polygonal Pole made single/two sections of hot dip galvanized GI sheet minimum 3mm thickness 100mm top diameter, 240 mm bottom diameter thickness 20mm base plate dimensions of 450x450x20 mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lightning spikes with single phase operation power tool installed inside the base compartment including connector, foundation bolt 4 nos M24 with 750 mm long fixed in existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD86510/2024-2025:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel .
14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD86511/2024-2025:Supply and fixing 60 mm long x 12 mm wide x 1 mm thick Copper earthing clips for 4 sq mm to 16 sq mm. single compression glands
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
15.4.1:Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required1 output per phase and suitable for single phase supply
OD86512/2024-2025:Supply and providing 2 pole power contactor with necessary NO/NC contacts suitable for street light switching arrangements
OD86513/2024-2025:Supply and providing 2 pole (1P+N) Type 2 Surge protection Device 15 kA rated conforms to IEC 61643-11 L and T make Cat. no: AUSP021PN15 or equivalent and giving connections
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7:Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG)
OD86514/2024-2025:Supply and fixing 25x6 mm brass bolt, nut and washer
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD86515/2024-2025:Supply and fixing 63 A 2 way neutral link on SMC or DMC base and giving connections
OD86516/2024-2025:Supply and fixing 63 A Fuse unit with HRC link on existing board using suitable bolt , nut and giving connections
OD86517/2024-2025:Supply and fixing Hot press molded SMC meter box size 450x375x200 mm Sintex make GS-MB- 4537 or equivalent make
OD86518/2024-2025:KSEB Charges for new single phase service connection including application Fee, CD , service connection charge etc. ( Actual amount paid on production of Original Bill/Invoice )
Bidder Name
POWER ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1095453.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .