| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Electrical Licence not enclosed |
| 4 | Not Admitted-Fee/PreQual/Technical C 51 SUDERSHANPURA INDUSTRIAL AREA BAIS GODAM JAIPUR JAIPUR RAJASTHAN 302006 | JAIPUR | RAJASTHAN | 302006 | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
Refer Docs
EMD Value
₹47,820
Closing Date
24 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CMC North
CMC JMC North
Supply Installation testing and commissioning lighting at Clock tower
2021_DLB_225914_1
RL 498 dated 03.06.2021 (JMC North)
Open Tender
Drilling Works
Item Rate
90 days
JMC Jodhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
MD RISL
₹47,820
Yes
5 Jul 2021
10 Jun 2021
25 Jun 2021
10 Jun 2021
24 Jun 2021
10 Jun 2021
60 days
Amount
Supply, Installation, Testing and commisioning of Color Changing 10W 4 in 1 RGBW LEDs surface mounted Projector luminaire(PAR) suitable for outdoor applications. Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. (Water proof) Luminaire should be Controlled through DMX/Ethernet protocol using DMX Controller . Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66/67. Housing should be made of pressure Die cast Aluminium with safety glass. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements.As per required and direction of engineering incharge (Make- Claypaky/LBT/PR and equiivalent make as per direction of engineering Incharge)
Supply, Installation, Testing and commisioning of Color Changing RGB 3W *36 surface mounted Projector luminaire(PAR) suitable for outdoor applications Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. (Water proof) Luminaire should be Controlled through DMX/Ethernet protocol using DMX Controller . Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66/67. Housing should be made of pressure Die cast Aluminium with safety glass. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. As per required and direction of engineering incharge e (Make- Claypaky/LBT/PR and equiivalent make as per direction of engineering Incharge)
Supply, Installation, Testing and commisioning of Color Changing 1000mm long RGBW surface mounted Narrow/Medium/Elliptical beam luminaire suitable for outdoor applications Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. Luminaire luminous flux range 1600-1900 Lm, Luminaire should be Controlled through DMX Controller Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66. Housing should be made of die casting Aluminium Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. As per required and direction of engineering incharge (Make- Claypaky/LBT/PR and equiivalent make as per direction of engineering Incharge)
Design, Supply, Installation Digital Multiplex (DMX) protocol lighting control with required Software, 240Dimmer control channels, Supplied with PC Application Avolites visualiser, pearl simulation program, 15Playback masters controlling 450 merories in all respect and support Wall Washer, Led par light etc. As per required and direction of engineering incharge (Make- Claypaky/LBT/PR and equiivalent make as per direction of engineering Incharge)
Supply and Fixing of UPS 600VA/360W for DMX controller. Generator Compatible. Wide input Range: 140-300V. With Cold Start Function & AVR which regulates voltage automatically. Heavy Duty 7AH battery, 3 Output Sockets, connect upto 3 devices. With a maximum backup of 45 minutes. Blazing fast transfer time of just 2-4 milliseconds, Fast Charging: 4 Hours for 90% charge. as per required and direction of engineering incharge (Make- Anslem and equiivalent make as per direction of engineering Incharge)
Supply and Fixing of Distributor for connecting of Light as per required and as per direction of engineering incharge
Supply and Fixing of Power Pannel 40KW as per required and direction of engineering incharge Make- Anslem and equiivalent make as per direction of engineering Incharge)
Supply and fixing of Iron Box for Light with required suitable size as per direction of engineering incharge
Supply and Fixing of extra Accessories like Par light Pin, Socket, Messanger wire etc as per required and direction of engineering incharge
Contractor must be depolyed technical qualified, insured staff for comprehansive Operation and maintanane with security of Lighting System at Clock Tower as per direction of engineering incharge and Maintain Log sheet for these Work
Bidder Name
Amount
BHAWANI ENTERPRISES(GSTN-08AHWPK2727R1ZC)
Janki Enterprises(GSTN-08ARMPM8092R1ZL)
BHAWANI ENTERPRISES
BHAWANI ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .