| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹18.1 L+₹21,320 (1.19%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹19.0 L+₹1.1 L (5.94%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹20.0 L+₹2.0 L (11.4%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹21.9 L+₹4.0 L (22.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Mar 2023, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001
REPAIR/REPLACEMENT OF STREET LIGHTS SECURITY LIGHTS WATCH TOWER LIGHTS CABLES AND CONNECTED E/M ITEMS UNDER GE LUDHIANA
2023_MES_579986_1
GE/LDH-74/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
280 days
under GE Ludhiana
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹50,000
Yes
20 Mar 2023
9 Feb 2023
10 Mar 2023
9 Feb 2023
8 Mar 2023
23 Feb 2023
9 Feb 2023 - 22 Feb 2023
Amount
Taking down existing street light fittings of any type/size/capacity fixed in any position i.e. on wall/ pole/ watch tower fixing the fitting in its original position after repairs complete all as specified and directed. (Note:-Spares shall be measured and paid seprately.
S&F in replacement LED street light luminaire of 45 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt. Brand name should be embossed on fixture to ensure Indian brand only.
S&F in replacement LED street light luminaire of 60 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt. Brand name should be embossed on fixture to ensure Indian brand only.
S&F in replacement LED street light luminaire of 90 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt. Brand name should be embossed on fixture to ensure Indian brand only.
S&F for LED flood light fitting of 120 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum with IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed.
S&F for LED flood light fitting of 150 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum with IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed.
S&F for LED flood light fitting of 200 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum with IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed.
S&F for LED post top lantern 40 W e-top with aluminium die cast housing cum heat sink with PMHA diffuser in IP 65 including taking down existing light fittings etc complete all as specified and directed by Engineer-in-Charge. Note for Srl No. 2 to 8 :- (i) All LED fittings shall have supporting LM-79 & LM-80 test certificate from govt approved NABL accredited Lab showing all the parameters duly signed by the local office bearer of manufacturer. (ii) All LED fittings shall have 2 years written Warranty from local office bearer of manufacturer. Make:-Compton/Havells/Bajaj/Wipro/Polycab/Surya
M&L for GI pipe medium grade 40mm dia 1.2 mtr long bend to shape as required and fixing with two nos MS clamp of size 40x6mm for fixing of street light fitting complete all as specified and directed.
S&F for 1100 volt grade heavy duty single core cable PVC insulated PVC sheathed with stranded copper conductor wire FRLS of size 2 x 1.5 Sqmm and 1 x 1.5 sqmm for connection purpose, ISI marked drawing through 20mm dia PVC pipe / conduit complete all as specified and directed by the Engr-in-Charge.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 10 Sqmm 2 core.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 10 Sqmm 4 core.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 16 Sqmm 4 core.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 25 Sqmm 4 core.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 35 Sqmm 4 core.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 70 Sqmm 4 core.
Excavating in trenches in soft/ loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation for pipes, walls, cesspits, manholes, pier holes, cables etc not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out complete all as specified.
Returning, filling in, spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified.
Removal of excavated spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
M&L for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed. Notes: (i) Excavation and earth work to be measured and paid for separately (ii) Thickness of 18 cms after punning shall be considered for payment.
M&L for old size sub class ‘B’ bricks laid flat in trenches over the cable with length of brick perpendicular to the direction of cable, adjacent/ abutting each other, complete all as specified and directed. Note: Excavation and earth work to be measured and paid for separately.
S&F for replacement of driver suitable for any type of street light 20W/45 watt complete all as specified and directed by Engineer- in-Charge.
Supply and fixing in replacement of driver suitable for any type of street light 60watt/90 W,120W,150/200 W complete all as specified and directed by Engineer- in-Charge.
Supply and fixing in replacement of Surge protection device suitable for any type of street light 20watt/45W complete all as specified and directed by Engineer- in-Charge.
Supply and fixing in replacement of Surge protection device suitable for any type of street light 60watt/90W,120/150/200 W, complete all as specified and directed by Engineer- in-Charge.
S&F in repair,installation,commissioning and testing Polycarbonate ASTA CPRI approved OEM made street light junction box Size 300 x 300 x 150mm.The junction box IP 65 & enclousers in accordance IEC 62208 with Test Report.The Manufacturer submitt report & Made of material POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1,clause 10.2.4,anti-acid,anti-corrosive & Fully Transparent Door for vision.Degree of protection against mechanical load should be IKO8 (5 Joule) in accordance with IEC 62262.Junction Box rated insulation voltage 1000V A.C.The manfacturer CPRI TEST REPORT IN POLYCARBONATE OEM,channel partner or sister concerned assembly will not accepted.Polyurethane gasket internally embedded and Enclouseres make Hensel/Clipsal.The Enclouser Self Closeable with hinged on uper side with Protection IP66.The manfacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic in accordance with IEC 60439-1.Each board shall have individual routine test report of the manfacturer.The panel should passed glow wire test 960oC in accordance with 60695-2-11 (flame retardant and self extinguishing).The Junction with 4 Nos Connectors and One Number MCB SP 6A 'C' Curve Provided 2 Nos Suitable Cable Glands with protection IP 66,Mounting Clamp and all Accessories Provided complete all as specified and directed by Engineer- in-Charge.
S&F in repair,installation,commissioning and testing Polycarbonate ASTA CPRI approved OEM made street light junction box Size 217 x 253 x 115mm.The junction box IP 66 & enclousers in accordance IEC 62208 with Test Report.The Manufacturer submitt report & Made of material POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1,clause 10.2.4,anti-acid,anti-corrosive & Fully Transparent Door for vision.Degree of protection against mechanical load should be IKO8 (5 Joule) in accordance with IEC 62262.Junction Box rated insulation voltage 1000V A.C.The manfacturer CPRI TEST REPORT IN POLYCARBONATE OEM,channel partner or sister concerned assembly will not accepted.Polyurethane gasket internally embedded and Enclouseres make Hensel/Clipsal.The Enclouser Self Closeable with hinged on uper side with Protection IP66.The manfacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic in accordance with IEC 60439-1.Each board shall have individual routine test report of the manfacturer.The panel should passed glow wire test 960oC in accordance with 60695-2-11 (flame retardant and self extinguishing).The Junction with 4 Nos Connectors and One Number MCB SP 6A 'C' Curve Provided 2 Nos Suitable Cable Glands with protection IP 66,Mounting Clamp and all Accessories Provided complete all as specified and directed by Engineer- in-Charge. Make Srl item No 27 & 28 :- Hensel/universal switchgear control
M&L for inreplacement MCCB 63 Amps, 4 pole, with adjustable thermal adjustable magnetic release, ICS=ICU=100%, 415 volts, 50 HZ, 25 KA complete all as specified & directed by Engineer-in- charge.
M&L for inreplacement MCCB 100 Amps, 4 pole, with adjustable thermal adjustable magnetic release, ICS=ICU=100%, 415 volts, 50 HZ, 25 KA complete all as specified & directed by Engineer-in- charge.
M & L for inreplacement TPN MCB,4 pole 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 63 Amps complete all as specified & directed by Engineer-in- charge.
M & L for inreplacement MCB SPN , 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 10 to 32 Amps complete all as specified & directed by Engineer-in- charge.
M&L for MCB SP 6 TO 32 Amps, 10 KA, C-curve complete all as specified & directed by Engineer-in- charge. Make Srl Item No.28 to 32 : Polycab/ indoasian / Havells / Hager
S&F for Automatic Street Light Switch using Nature switch for automatic switching of street lights based on LUX level of Natural light. The Infrared Sensor based Nature Switch along of capacity of 5 KW, three phase, with suitable Power Contactor(AC 3) 20-32 Amps and MCBs SP (Input-Output) 32 Amps on each phase at incoming and out going connections fully enclosed in pole/wall mountable enclosure, weather and vermin proof having front hinged shutter, rust proof, termite proof and FR grade SMC junction box having to IP 54 protection, pre-wired complete with suitable wire PVC insulated FRLS type copper conductor with suitable copper thimbles/lugs etc complete all as specified and directed. Make of Nature Switch : Kakatiya Energy Systems Pvt Ltd Hyderabad/ Bajaj/Healer. Make of Contactor : BCH/L&T/Schneider. Make of MCB : Hager/Schneider/L&T/BCH. Make of copper wire : Finolex/Polycab/RR Kable. Make of junction box : Hensel/Schneider/Rittal
M&L for painting of LT Steel tubular pole with junction box,clump and bracket any type of size externally above foundation with two coat of almn paint over a coat of red oxide primer after scraping/cleaning well the existing surface incl painting of bottom with black white or yellow color strip 30cm each upto 1.5 mtr high from top of PCC foundation block and numbring of pole with synthetic enamel paint white in 80mm high letter over 150mmx230mm yellow base complete.
Supply and fixing for galvanised pipe light grade of ISI marked 50 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and directed by Engr-in-charge.
Supply and fixing for galvanised pipe light grade of ISI marked 80 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and directed by Engr-in-charge.
M&L for LT fedder piller box out door type made out of MS sheet CRCA of sheet 3.0 mm thick 90x45x60 cm size with aluminium busbar 4 No's 200 Amp long suitable for 440 volts and mounted on LT protection insulator, Front opening door two leaf braced with continue hinges mounted on 4 Nos angle iron 60 cm long duly included with box and grouted in PCC block of size 30x30x15 cm in concrete 1:3:6 and top of box MS sheet duly in step types with protection of 20mm on all sides weather/vermen proof with high quality rubber bedding on panel door, cable entry arrangements at bottom including earthing terminals 2 No's at both sides, cable gland connecting to busbar and painted with red stove enammeled powder coated paint two coats over red oxide primer complete all as specified & directed by Engineer-in- charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-1 and CI cover with frame, 150 mm,filling of black cotton soil in earth pit up to ground level PCC chamber recessed for including RCC cover including all necessary Exacavation &earth work ,earth wire connected to O/H continous earth wire on pole ,testing the earthing after completion all as shown in MES Schedule (Part-I) including dismantling existing earthing complete. Notes :- (i) Outer edge of earth pit will be 1.50 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slantling position (iv) Earth wire and protection pipe upto 7.50m length is icluded in the unit rate
JASSI TRADERS
CHOUDHARY ENTERPRISES
SUN MANN ENGINEERS
M/s Bansi Lal
Kissan contractor and engg works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .