| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1(Anterior Cervical Plating System Variable Angle Screw System) * A single plate must provide the option of rigid, toggling and hybrid construct. * The cephalad/caudal angulation must be of approx. 28 degrees. With 8degree of. offset * The Lateral/Medial angulation range must be of 14 degrees with 7 degrees of offset. * Locking mechanism of the screw must be one step locking with ELGILOY CLIP Should block the screws from coming out. * The plate must be 1.8 -2.5mm in thickness and 16-17.5 mm in width * The core diameter of the screws must be 3mm with outer diameter being 4.0mm and 4.5mm and self-drilling "* The plates must be available in following sizes: one level plates 22.6-34.6 mm, Two level plates 36.6-54.6mm three level plates 53.6-77.6mm and four level plates" The plate us be available in following sizes | |||||
| 1.01 | a) Cervical Plate Level - 1 | 1 | Nos | - | - |
| 1.02 | b) Cervical Plate Level - 2 | 1 | Nos | - | - |
| 1.03 | c) Cervical Plate Level - 3 | 1 | Nos | - | - |
| 1.04 | d) Cervical Plate Level – 4 | 1 | Nos | - | - |
| 2(Anterior Cervical Interbody Fusion device with screw mechanism (zero profile) | |||||
| 2.01 | * The Implant should act as standalone interbody fusion device for cervical spine with the benefits of an interbody spacer and an anterior cervical spine.
* The implant must be a combination of PEEK/Titanium must automatically align when inserted
"* The implant must have radio opaque marker for posterior and anterior visualization during imaging and teeth on superior and anterior surface for initial
stability"
* Spacer component must be made of PEEK
"* The implant must have on one step locking screw and should form a bone wedge with 40° + 5° cranial/caudal angle with 2.5° medial and lateral angle."
* The screw must come with self-tapping or self-drilling and self-cantering options with titanium alloy material
* The screw must come in 3.0mm to 4.5mm diameter & must be colour coded by screw lengths varying from 12-20mm.
* The implants must come in parallel lordotic and convex implants sets with heights varying from 5mm to 12mm with an increment of 1mm each.
* Should have option for 2-4 screws | 1 | Nos | - | - |
| 3(Anterior Cervical Interbody Fusion device with screw mechanism (zero profile) | |||||
| 3.01 | a) Occipital Plate (t or Y shaped) | 1 | Nos | - | - |
| 3.02 | b) C1 -C2 spacer | 1 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
BOQ_1066459.xls
BOQ • 0.68 MB
neurosurgery.pdf
Tender Documents • 26.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .